• Title/Summary/Keyword: voltage margin

검색결과 294건 처리시간 0.028초

Fabrication of MFISFET Compatible with CMOS Process Using $SrBi_2Ta_2O_9$(SBT) Materials

  • You, In-Kyu;Lee, Won-Jae;Yang, Il-Suk;Yu, Byoung-Gon;Cho, Kyoung-Ik
    • Transactions on Electrical and Electronic Materials
    • /
    • 제1권1호
    • /
    • pp.40-44
    • /
    • 2000
  • Metal-ferroelectric-insulator-semoiconductor field effect transistor (MFISFETs) were fabricated using CMOS processes. The Pt/SBT/NO combined layers were etched for forming a conformal gate by using Ti/Cr metal masks and a two step etching method, By the method, we were able to fabricate a small-sized gate with the dimension of $16/4{\mu}textrm{m}$ in the width/length of gate. It has been chosen the non-self aligned source and drain implantation process, We have deposited inter-layer dielectrics(ILD) by low pressure chemical vapor deposition(LPCVD) at $380^{circ}C$ after etching the gate structure and the threshold voltage of p-channel MFISFETs were about 1.0 and -2.1V, respectively. It was also observed that the current difference between the $I_{ON}$(on current) and $I_{OFF}$(off current) that is very important in sensing margin, is more that 100 times in $I_{D}-V_{G}$ hysteresis curve.

  • PDF

대형캐비테이션터널(LCT) 실물 구동펌프 성능시운전 (Performance Trial-Test of the Full-Scale Driving Pump for the Large Cavitation Tunnel(LCT))

  • 안종우;김건도;김기섭;박영하
    • 대한조선학회논문집
    • /
    • 제52권6호
    • /
    • pp.428-434
    • /
    • 2015
  • The objective of the present study is to analyze the results of the trial-test for the full-scale driving pump, which is arranged in the LCT (Large Cavitation Tunnel). Firstly, the reasons of selecting the final design pump are introduced in terms of the performance analysis in model tests. The trial-test items for the full-scale driving pump are measurements of output current/voltage at the inverter of the main motor and the flow velocity in the LCT test section. The test results show the increase in flow rate of about 10.7% and the decrease in pump head of about 26%, compared with those of final design-pump specification. The motor power has the margin of about 22%. The performance analysis for the full-scale pump is conducted using the commercial code (CFX-10). The delivered power calculated with CFX-10 shows good agreement with that extracted from the full-scale pump test. It is found that CFX-10 is useful to analyze a full-scale pump.

전압안정도 제약을 고려한 조상설비 최적투입계획 (Optimal Var sizing and Allocation Considering Voltage Stability Margin)

  • 성웅;김태균;이병준;송화창;김태균;신정훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.95-96
    • /
    • 2008
  • 사회가 발전함에 따라 전력 수요는 기하급수적으로 증가한다. 늘어나는 전력 수요는 전압안정도 마진을 감소시키고 이는 대정전의 원인이 될 수도 있기 때문에 전력계통에서 전압유지 및 전압안정도 여유확보는 중요한 이슈가 된다. 무효전력은 전압과 큰 관련이 있기 때문에 전압유지 및 전압안정도 여유확보 방안으로써 가장 최우선적으로 고려되는 사항이 조상설비를 추가하는 것이다. 하지만 조상설비를 추가하기 위한 용지확보, 비용, 환경문제 등의 영향으로 인한 전원의 원격화, 편재화 그리고 부하의 수요집중화에 의한 송전설비의 장거리화와 대용량화가 진행되고 있으며 이와 같은 장거리 송전에 따라 계통손실의 증가와 수요지의 저전압문제가 발생하고 있다. 그러므로 전압안정도 마진을 고려하면서 조상설비를 적절하게 투입하는 것은 중요한 고려사항이다. 본 논문은 2007년 8월 EMS Peak 데이터를 시뮬레이션 해 조상설비를 투입함에 있어 최적의 위치와 용량을 산정하는 위한 방안을 제시한다. 이러한 조상설비 추가를 최소로 하는 경제적인 측면 뿐 아니라 전압 안정성 측면도 고려하기 위한 부하 scaling 기법을 적용해 전압안정도 여유를 확보하기 위한 방안을 추가한다. 또한 여러 가지 상정사고를 가정한 후 heuristic method를 적용해 조상설비 최적화를 수행하고 한전데이터를 근거로 추가할 조상설비의 가장 적절한 투입위치 및 용량을 산정해 제시한다.

  • PDF

Designing an Emotional Intelligent Controller for IPFC to Improve the Transient Stability Based on Energy Function

  • Jafari, Ehsan;Marjanian, Ali;Solaymani, Soodabeh;Shahgholian, Ghazanfar
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권3호
    • /
    • pp.478-489
    • /
    • 2013
  • The controllability and stability of power systems can be increased by Flexible AC Transmission Devices (FACTs). One of the FACTs devices is Interline Power-Flow Controller (IPFC) by which the voltage stability, dynamic stability and transient stability of power systems can be improved. In the present paper, the convenient operation and control of IPFC for transient stability improvement are considered. Considering that the system's Lyapunov energy function is a relevant tool to study the stability affair. IPFC energy function optimization has been used in order to access the maximum of transient stability margin. In order to control IPFC, a Brain Emotional Learning Based Intelligent Controller (BELBIC) and PI controller have been used. The utilization of the new controller is based on the emotion-processing mechanism in the brain and is essentially an action selection, which is based on sensory inputs and emotional cues. This intelligent control is based on the limbic system of the mammalian brain. Simulation confirms the ability of BELBIC controller compared with conventional PI controller. The designing results have been studied by the simulation of a single-machine system with infinite bus (SMIB) and another standard 9-buses system (Anderson and Fouad, 1977).

전류 및 전위 측정선간 상호유도가 접지임피던스에 미치는 영향 (The Effect of Mutual Coupling between Current and Potential Test Leads on Ground Impedance)

  • 엄주홍;조성철;이태형
    • 전기학회논문지
    • /
    • 제57권7호
    • /
    • pp.1223-1228
    • /
    • 2008
  • While a high frequency source is used for measuring the ground impedance, there are several factors having an effect on the measured value. A primary factor of the measurement error is the ac mutual coupling between current and potential test leads. The mutual coupling causes the test current to induce a voltage into the potential test lead that adds to the actual ground potential rise and produces a significant measurement error as the length of the test leads paralleled is prolonged. In order to avoid the mutual coupling, it is recommended that the ground impedance be measured by angled arrangement of test leads. The mutual impedance due to the inductive coupling with an angle of $90^{\circ}$ was calculated at $0^{\circ}$ by Campbell/Foster Method. With an angle of $180^{\circ}$, the mutual impedance was calculated large value enough to introduce a fairly large margin of error, however, the measured value of ground impedance was close to the value at $90^{\circ}$.

볼로미터형 적외선 센서의 신호처리회로 설계 및 특성 (Design and analysis of a signal readout integrated circuit for the bolometer type infrared detect sensors)

  • 김진수;박민영;노호섭;이승훈;이제원;문성욱;송한정
    • 센서학회지
    • /
    • 제16권6호
    • /
    • pp.475-483
    • /
    • 2007
  • This paper proposes a readout integrated circuit (ROIC) for $32{\times}32$ infrared focal plane array (IRFPA) detector, which consist of reference resistor, detector resistor, reset switch, integrated capacitor and operational amplifier. Proposed ROIC is designed using $0.35{\;}{\mu}m$ 2P-4M (double poly four metal) n-well CMOS process parameters. Low noise folded cascode operational amplifier which is a key element in the ROIC showed 12.8 MHz unity-gain bandwidth and open-gain 89 dB, phase margin $67^{\circ}$, SNR 82 dB. From proposed circuit, we gained output voltage variation ${\Delta}17{\};mV/^{\circ}C$ when the detector resistor varied according to the temperature.

가전용 커패시터의 소손원인 규명 및 발열 메커니즘 해석 (Examination of the Cause of Damage to Capacitors for Home Appliances and Analysis of the Heat Generation Mechanism)

  • 박형기;최충석
    • 한국안전학회지
    • /
    • 제26권6호
    • /
    • pp.13-19
    • /
    • 2011
  • The purpose of this study is to examine the cause of damage to electrolytic capacitors and to present the heat generation mechanism in order to prevent the occurrence of similar problems. From the analysis results of electrolytic capacitors collected from accident sites, the fire causing area can be limited to the primary power supply for the initial accident. From the tests performed by applying overvoltage, surge, etc., it is thought that the fuse, varistor, etc., are not directly related to the accidents that occurred. The analysis of the characteristics using a switching regulator showed that the charge and discharge characteristics fell short of standard values. In addition, it is thought that heated electrolytic capacitors caused thermal stress to nearby resistances, elements, etc. It can be seen that the heat generation is governed by the over-ripple current, application of AC overvoltage, surge input, internal temperature increase, defective airtightness, etc. Therefore, when designing an electrolytic capacitor, it is necessary to comprehensively consider the correct polarity arrangement, appropriate voltage application, correct connection of equivalent series resistance(ESR) and equivalent series inductance(SEL), rapid charge and discharge control, sufficient margin of dielectric tangent, etc.

무효전력 흐름 추적을 이용한 무효전력 취약지역 판단 (Reactive Power Traceable System based Vulnerable Areas Detection for Reactive Power)

  • 최윤혁;배문성;이병준
    • 전기학회논문지
    • /
    • 제64권8호
    • /
    • pp.1145-1153
    • /
    • 2015
  • The paper analyzes reactive power flow characteristic in power system by reactive power tracing. In addition, virtual buses are inserted in the algorithm to consider losses of transmission lines, and shunt capacitor treated as a reactive power generator. The results of simulation are analyzed by two points of view. The one is load’s point of view and another is generator’s point of view. Classic purpose of the reactive power tracing consists in the reactive power pricing. However, it is significantly used to select vulnerable area about line outage in this paper. To find the vulnerable area, reactive power tracing variations between pre-contingency and post-contingency are calculated at all load buses. In heavily load area, buses which has highest variation become the most vulnerable bus. This method is applied to the IEEE 39-bus system. It is compared with voltage variation result and VQ-margin to verify its effect.

양방향성 PWM컨버터를 이용한 가정용 태양광 에어컨 시스템에 관한 연구 (A study of residential solar airconditioning system using bidirectional PWM converter)

  • 유권종;송진수;황인호;김홍성;고재석;최규하;김한성
    • 대한전기학회논문지
    • /
    • 제45권3호
    • /
    • pp.358-364
    • /
    • 1996
  • Recently, much power demand from domestic power consumer is weakening the allowable power reserve margin in summer, especially at midday for one day due to a steep increase of air cooling loads such as air conditioner. Therefore solar airconditioning system can'be considered as one of the best remedies to meet the increase of peak power. Generally in solar air conditioning system, the diode rectifier is used to build up DC link voltage from AC source. The diode rectifier is simple and cheap but it brings out the problems of low power factor and plentiful harmonics at the AC source. Also It can derate the utilization rate of solar energy because the reverse of power flow cannot be made. Hence, in this paper to overcome the peak power problem in summer and to endure good AC input characteristics, solar air conditioning system using the PWM converter is proposed. As results, obtained are the characteristics of the PWM converter such as low distorted current waveform, high power factor and bidirectional power control. And also the stability of proposed system is verified by examining the dynamics of step load change and power reversal testing. (author). refs., figs., tabs.

  • PDF

비선형 주.쌍대내점법을 이용한 부하공급능력의 산정에 기반한 전력수송능력의 평가 (Evaluation of Transfer Capability based on Load Supplying Capability Calculation using Nonlinear Primal-Dual Interior Point Method)

  • 정민화;이병준;송길영
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권4호
    • /
    • pp.161-167
    • /
    • 2000
  • This paper presents a new methodology that can evaluate transfer capability of composite power systems from the adequacy point of view in power system planning stages. First of all, to evaluate practical load supplying capability, nonlinear optimization problems of maximum load supplying capability(MLSC) and economic load supplying capability(ELSC) are formulated and solved by nonlinear primal-dual interior point method. Here, physical constraints considered in the optimization problems are the limits of bus voltage, line overloading, and real & reactive power generation. Also, an evaluation method of transfer capability is presented based on margins calculated by the MLSC and ELSC. Especially, to evaluate transfer capability flexibly, simple indices such as expected MLSC, transfer capability margin, and power not supplied are respectively proposed by considering (N-1) line outage probability. Numerical results on IEEE RTS 24, IEEE 118, and IEEE 300 bus system show that the proposed algorithm is effective and useful for power system planning stages.

  • PDF