• 제목/요약/키워드: voltage harmonic propagation

검색결과 8건 처리시간 0.023초

연료전지 전원을 갖는 Z-소스 능동전력필터에 의한 장거리 배전선로의 전압 THD 저감 (Voltage THD Mitigation of Power Distribution System using Z-Source Active Power Filter with a Fuel Cells Source)

  • 정영국
    • 전기학회논문지
    • /
    • 제57권12호
    • /
    • pp.2161-2166
    • /
    • 2008
  • This paper deals with a Z-source active power filter(Z-AFU) for mitigation voltage THD(total harmonic distortion) due to voltage harmonic propagation(amplification) in 6.6kv power distribution system. Bus voltage harmonic signal is detected by 60Hz butterworth BPF(band pass filter). As an ESS(energy storage system) of the proposed system, PEM fuel cells(Ballard NEXA, 1.2kw) is employed. Test results based on PSIM(power electronics simulation tool) validate the proposed approach.

Modeling of Power Networks by ATP-Draw for Harmonics Propagation Study

  • Ali, Shehab Abdulwadood
    • Transactions on Electrical and Electronic Materials
    • /
    • 제14권6호
    • /
    • pp.283-290
    • /
    • 2013
  • This paper illustrates the possibilities of using the program ATP-Draw (Alternative Transient Program) for the modeling of power networks to study power quality problems with highly detailed analyses. The Program ATP-Draw is one of the most widespread and oldest programs. A unique characteristic of this program is its public domain and the existence of forums and study committees where new application cases and modification are presented and shared publicly. In this paper, to study the propagation of harmonics through a power network, a part of an industrial power network was modeled. The network contains different types of electric components, such as transformers, transmission lines, cables and loads, and there is a source of harmonics that injects $3^{rd}$, $5^{th}$, $7^{th}$, $9^{th}$ and $11^{th}$ harmonic currents into the network, causing a distortion of the wave form of the currents and voltages through the power network.

고압 수용가용 배전반의 intelligent화 연구 (A Study on the Intelligent High Voltage Switchboard for Custormer)

  • 변영복;조기연;구헌회
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.444-446
    • /
    • 1994
  • This paper describes the design of a digital multifunction controller for the intelligent high voltage customer switchboard and proposes a relaying algorithm for high impedance faults using back-propagation neural network. The hardware design uses the three microprocessors and global memory architecture to achive real time operation and control 4 feeders. The controller uses a 64-point radix-4 DIF FFT algorithm to measure the harmonic and relay parameters. Synthesized fault current waveforms are used to train and test the back - propagation network.

  • PDF

GIS 결합부의 음향신호 전달특성 (Propagation characteristics of AE signal in the connection of GIS)

  • 서판석;최남호;구경완;김종석;한상옥
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.311-314
    • /
    • 2001
  • This paper describes the simulation study, conducted on the propagation characteristics of AE signal in the connection of GIS. In the high voltage and large power system, the equipment with SF$\sub$6/ gas insulation which consists of the component part enclosed in the compressed gas has less affected by the environment than with air insulation. When the breakdown in the electric installation occurs, it takes much time to repair them though. Therefore it is very important to diagnose the propagation characteristics of AE signal in the GIS. So, in this investigation, we make a plane model of 362 kV GIS and modal and harmonic analysis to observe the vibro-acoustic property. Through the result of the analysis, we can make a further understanding on the vibro-acoustic characteristics of AE singnal in the connection of GIS.

  • PDF

고조파 성분을 이용한 고저항 지락 사고 검출 기법에 관한 연구 (A Study on High Impedance Fault Detection Method Using Harmonic Components)

  • 유창완;심재철;임화영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.1015-1017
    • /
    • 1997
  • A high impedance fault on the multi-grounded three-phase four-wire distribution system can not be detected by conventional overcurrent sensing devices. In this paper, the neural network is used to detect high impedance faults. The proposed algorithm using back - propagation neural network is demonstrated by simulation with the staged fault test data. The harmonic components of current and the phase of voltage are used as the inputs of neural network. Results of the simulation can be used as a reference for the development of a high impedance fault detector.

  • PDF

디지털 록인 앰프를 이용한 새로운 하이브리드 방식의 단독운전 검출법 (A Novel Hybrid Islanding Detection Method Using Digital Lock-In Amplifier)

  • Ashraf, Muhammad Noman;Choi, Woojin
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2019년도 전력전자학술대회
    • /
    • pp.77-79
    • /
    • 2019
  • Islanding detection is one of the most important issues for the distributed generation (DG) systems connected to the power grid. The conventional passive islanding detection methods inherently have a non-detection zone (NDZ), and active islanding detection methods may deteriorate the power quality of a power system. This paper proposes a novel hybrid islanding detection method based on Digital Lock-In Amplifier with no NDZ by monitoring the harmonics present in the grid. Proposed method detects islanding by passively monitoring the grid voltage harmonics and verify it by injecting small perturbation for only three-line cycles. Unlike FFT for the harmonic extraction, DLA HC have lower computational burden, moreover, DLA can monitor harmonic in real time, whereas, FFT has certain propagation delay. The simulation results are presented to highlight the effectiveness of the proposed technique. In order to prove the performance of the proposed method it is compared with several passive islanding detection methods. The experimental results confirm that the proposed method exhibits outstanding performance as compared to the conventional methods.

  • PDF

Slender piezoelectric beams with resistive-inductive electrodes - modeling and axial wave propagation

  • Schoeftner, Juergen;Buchberger, Gerda;Benjeddou, Ayech
    • Smart Structures and Systems
    • /
    • 제18권2호
    • /
    • pp.335-354
    • /
    • 2016
  • This contribution presents an extended one-dimensional theory for piezoelectric beam-type structures with non-ideal electrodes. For these types of electrodes the equipotential area condition is not satisfied. The main motivation of our research is originated from passive vibration control: when an elastic structure is covered by several piezoelectric patches that are linked via resistances and inductances, vibrational energy is efficiently dissipated if the electric network is properly designed. Assuming infinitely small piezoelectric patches that are connected by an infinite number of electrical, in particular resistive and inductive elements, one obtains the Telegrapher's equation for the voltage across the piezoelectric transducer. Embedding this outcome into the framework of Bernoulli-Euler, the final equations are coupled to the wave equations for the longitudinal motion of a bar and to the partial differential equations for the lateral motion of the beam. We present results for the wave propagation of a longitudinal bar for several types of electrode properties. The frequency spectra are computed (phase angle, wave number, wave speed), which point out the effect of resistive and inductive electrodes on wave characteristics. Our results show that electrical damping due to the resistivity of the electrodes is different from internal (=strain velocity dependent) or external (=velocity dependent) mechanical damping. Finally, results are presented, when the structure is excited by a harmonic single force, yielding that resistive-inductive electrodes are suitable candidates for passive vibration control that might be of great interest for practical applications in the future.

단상 PVPCS 출력 전류의 리플 개선을 위한 노치 필터 및 피드 포워드 제어기 설계 (The Feed-forward Controller and Notch Filter Design of Single-Phase Photovoltaic Power Conditioning System for Current Ripple Mitigation)

  • 김승민;양승대;최주엽;최익;이영권
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.325-330
    • /
    • 2012
  • A single-phase PVPCS(photovoltaic power conditioning system) that contains a single phase dc-ac inverter tends to draw an ac ripple current at twice the out frequency. Such a ripple current may shorten passive elements life span and worsen output current THD. As a result, it may reduce the efficiency of the whole PVPCS system. In this paper, the ripple current propagation is analyzed, and two methods to reduce the ripple current are proposed. Firslyt, this paper presents notch filter with IP voltage controller to reject specific current ripple in single-phase PVPCS. The notch filter can be designed that suppress just only specific frequency component and no phase delay. The proposed notch filter can suppress output command signal in the ripple bandwidth for reducing output current THD. Secondly, for reducing specific current ripple, the other method is feed-forward compensation to incorporate a current control loop in the dc-dc converter. The proposed notch filter and feed-forward compensation method have been verified with computer simulation and simulation results obtained demonstrate the validity of the proposed control scheme.

  • PDF