• 제목/요약/키워드: voltage drop

검색결과 746건 처리시간 0.026초

PV 모듈 내 바이패스 다이오드 손상에 의한 열적 전기적 특성 변화 분석 (Analysis on thermal & electrical characteristics variation of PV module with damaged bypass diodes)

  • 신우균;정태희;고석환;주영철;장효식;강기환
    • 한국태양에너지학회 논문집
    • /
    • 제35권4호
    • /
    • pp.67-75
    • /
    • 2015
  • PV module is conventionally connected in series with some solar cell to adjust the output of module. Some bypass diodes in module are installed to prevent module from hot spot and mismatch power loss. However, bypass diode in module exposed outdoor is easily damaged by surge voltage. In this paper, we study the thermal and electrical characteristics change of module with damaged bypass diode to easily find module with damaged bypass diode in photovoltaic system consisting of many modules. Firstly, the temperature change of bypass diode is measured according to forward and reverse bias current flowing through bypass diode. The maximum surface temperature of damaged bypass diode applied reverse bias is higher than that of normal bypass diode despite flowing equal current. Also, the output change of module with and without damaged bypass diode is observed. The output of module with damaged bypass diode is proportionally reduced by the total number of connected solar cells per one bypass diode. Lastly, the distribution temperature of module with damaged bypass diode is confirmed by IR camera. Temperature of all solar cells connected with damaged bypass diode rises and even hot spot of some solar cells is observed. We confirm that damaged bypass diodes in module lead to power drop of module, temperature rise of module and temperature rise of bypass diode. Those results are used to find module with a damaged bypass diode in system.

저전력 무선통신 기반 다중 프로토콜 게이트웨이 시스템 설계 (Design of a Multi-Protocol Gateway System Based on Low Power Wireless Communications)

  • 홍성일;인치호
    • 한국통신학회논문지
    • /
    • 제40권10호
    • /
    • pp.2006-2013
    • /
    • 2015
  • 본 논문에서는 저전력 무선통신 기반 다중 프로토콜 게이트웨이 시스템 설계를 제안한다. 제안 된 멀티 프로토콜 게이트웨이 시스템은 가로등 전력 제어 및 환경 모니터링을 위한 정보를 수집하여 무선 네트워크와 유선 네트워크를 통해 현장 상황을 실시간으로 모니터링 및 제어 할 수 있도록 설계하였다. 코드분할 다중접속 및 이더넷, 위성 항법장치, 저전력 무선통신 등의 유선 또는 무선통신을 선택적으로 사용한 복합처리와 함께 다중 센서를 이용하여 수집 된 데이터를 저전력 무선통신을 통해 서버로 전송하는 중개 역할을 하도록 설계하였다. 그리고 유지보수 비용 및 하드웨어 교체 용이성을 위해 CPU 및 베이스 보드로 분리하여 설계하였다. 본 논문에서 제안된 다중 프로토콜 게이트웨이 시스템의 전원, 충격, 연속동작 신뢰성 검증결과, 95% 이상의 정상동작 성공률 및 정상적인 연속동작 결과를 얻을 수 있었다. 그리고 전압 강하 및 순간 내성시험, 전도성 RF 전자기장 내성시험에서 평균 A등급의 평가결과를 얻을 수 있었다.

유도형과 저항형 초전도한류기의 파라메타를 고려한 전력계통도입효과의 분석 및 성능평가에 관한 연구 (On the Current Limiting Characteristics and Parameters of Superconducting Fault Current Limiter Introduced to 345kV Electric Power System due to Resistive-Type, Reactive-Type and Their Performance Comparison)

  • 홍원표;김용학
    • 조명전기설비학회논문지
    • /
    • 제16권3호
    • /
    • pp.74-83
    • /
    • 2002
  • 본 논문은 전력설비에 조기적용이 예상되는 초전도한류기의 파라메타를 정의하고 앞으로 개발방향을 제시하기 위하여 한류기의 동작원리, 특성 및 계통조기적용가능성들을 근거로 파라메타의 특성을 비교 ·평가하였다. 또한 한류기의 계통적용효과를 분석하기 위하여 SFCL이 기간 특고압 모델계통에 도입한 경우를 상정하여 3선지락 고장에서 저항형과 유도형 SFCL의 도입 효과에 대하여 RTDS (Real Time Digital Simulation)/EMTDC(Electromagnetic Transient DC)로 시뮬레이션하였다. 특히 저항형과 유도형의 한류효과의 비교 평가, 모선전압의 저하 억제 및 계통과 한류기의 파라메타와의 관련성에 대하여 검토하였다.

단상 유도전동기의 무부하손실을 고려한 등가회로 정수의 결정 (Determination of Parameters of Equivalent Circuit Taking No-Load Losses Into Account for Single-Phase Induction Motors)

  • 좌종근;김도진
    • 전기학회논문지P
    • /
    • 제59권4호
    • /
    • pp.358-363
    • /
    • 2010
  • This paper proposes a step-by-step method of determining the parameters of equivalent circuit which is considered the no load losses for the single phase induction motor which has the starting winding. This method is comprised of three steps, and the stator resistance which is measured by the method of voltage drop is treated as constant and the stator and the rotor leakage reactances are assumed to be the same in every step. The test results of no load and locked rotor test are used in the 1st and 2nd step, and the ratings of name plate of the motor are needed in the 3rd step. In the 1st step, the traditional equivalent circuit parameters are directly calculated by no load and locked rotor conditions. In the next step, five nonlinear simultaneous equations for five unknown parameters can be set up by no load and locked rotor equivalent circuits. These equations are solved by using the initial parameters obtained by the 1st step parameters. In the final step, three nonlinear simultaneous equations for rotor winding resistance, leakage reactance and no load losses component resistance can be set up by equivalent circuit under the rated operation. Three parameters are solved by using the 2nd step parameters. Thus, equivalent circuit parameters are gradually refined step by step. The validity of the proposed method is evaluated by comparing the computed values obtained by the equivalent circuit parameters with the experimental values of the load test.

협대역 고출력 전자기파로 인한 CMOS IC에서의 오동작 특성 연구 (A Study on Malfunction Mode of CMOS IC Under Narrow-Band High-Power Electromagnetic Wave)

  • 박진욱;허창수;서창수;이성우
    • 한국전기전자재료학회논문지
    • /
    • 제29권9호
    • /
    • pp.559-564
    • /
    • 2016
  • This study examined the malfunction mode of the HCMOS IC under narrow-band high-power electromagnetic wave. Magnetron is used to a narrow-band electromagnetic source. MFR (malfunction failure rate) was measured to investigate the HCMOS IC. In addition, we measured the resistance between specific pins of ICs, which are exposed and not exposed to the electromagnetic wave, respectively. As a test result of measurement, malfunction mode is shown in three steps. Flicker mode causing a flicker in LED connected to output pin of IC is dominant in more than 7.96 kV/m electric field. Self-reset mode causing a voltage drop to the input and output of IC during electromagnetic wave radiation is dominant in more than 9.1 kV/m electric field. Power-reset mode making a IC remained malfunction after electromagnetic radiation is dominant in more than 20.89 kV/m. As a measurement result of pin-to-pin resistance of IC, the differences between IC exposed to electromagnetic wave and normal IC were minor. However, the five in two hundred IC show a relatively low resistance. This is considered to be the result of the breakdown of pn junction when latch-up in CMOS occurred. Based on the results, the susceptibility of HCMOS IC can be applied to a basic database to IC protection and impact analysis of narrow-band high-power electromagnetic waves.

Consolidation of marine clay using electrical vertical drains

  • Shang, J.Q.;Tang, Q.H.;Xu, Y.Q.
    • Geomechanics and Engineering
    • /
    • 제1권4호
    • /
    • pp.275-289
    • /
    • 2009
  • Electroosmosis (EO) is the movement of water in a porous medium under the influence of a direct current (dc). In past decades, electro-osmosis has been successfully employed in many soil improvement and other geotechnical engineering projects. Metal electrodes, such as steel, copper and aluminum have been used traditionally to conduct current. The shortcoming of these electrodes is that they corrode easily during an EO treatment, which results in reduced effectiveness and environmental concerns. More recently, conductive polymers are developed to replace metal electrodes in EO treatment. Electrical vertical drainages (EVDs) are one of these products under trial. The goal of this study is to assess the performance of EVDs for soil improvement and to further understand the scientific principle of the EO process, including the voltage drop at the soil-EVD interface, electrical current density, polarity reversal, and changes in soil physico-chemical properties generated by electroosmosis. It is found from the study that after 19 days of EO treatment with a constant applied dc electric field intensity of 133 V/m, the soil's moisture content decreased by 28%, the shear strength and pre-consolidation pressure increased more than 400%. It is also found that the current density required triggering the water flow in the soil tested, the Korean Yulchon marine clay, is 0.7 $A/m^2$. The project demonstrates that EVDs can serve as both electrodes and drains for soil improvement in short term. However, the EVDs, as tested, are not suitable for polarity reversal in EO treatment and their service life is limited to only 15 days.

Dead ended 모드에서 수소 재순환이 고분자전해질연료전지의 성능에 미치는 영향 (Effect of Hydrogen Recirculation on the Performance of Polymer Electrolyte Membrane Fuel Cell with Dead Ended Mode)

  • 김준섭;김준범
    • Korean Chemical Engineering Research
    • /
    • 제57권4호
    • /
    • pp.531-538
    • /
    • 2019
  • 고분자전해질 연료전지(PEMFC)의 성능이 개선됨에 따라 생성물인 물과 열의 발생이 증가하고 이를 처리하기 위한 관리기법이 중요해지고 있다. 본 연구에서는 물 관리 기법으로 수소 재순환을 적용하였고, 수소 재순환 유량(flow rate)과 퍼지 간격(purge interval) 및 지속 시간(duration)이 연료전지의 성능에 미치는 영향에 대한 실험을 수행하였다. Purge 조건의 영향을 해석하기 위하여 수소극의 압력, 연료의 습도, 운전 간의 연료 이용 효율과 물 배출 양을 측정하였다. 수소 재순환 유량이 증가할수록 수소극 출구의 압력 저하로 인하여 스택 성능이 낮아졌다. Purge 조건에 따라서 물을 효과적으로 배출하지 못해 순간적인 전압 강하가 발생하거나 혹은 잦은 purge로 인해 수소극의 습도를 유지하지 못하여 성능이 점차적으로 감소하는 것을 확인하였다. Purge 조건 실험을 통하여 수소극의 습도를 유지하고 응축된 물을 충분히 배출할 수 있는 purge interval과 duration을 선정하였고, 이를 통하여 스택의 성능과 연료 이용 효율을 향상시킬 수 있었다.

네트워크 배전계통용 백업 보호협조에 관한 연구 (Research on Backup Protective Coordination for Distribution Network)

  • 김우현;채우규;황성욱;김주용
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제8권1호
    • /
    • pp.15-19
    • /
    • 2022
  • The radial distribution systems (RDS) commonly used around the world has the following disadvantages. First, when the DL is operated on a radial system, the line utilization rate is usually kept low. Second, if a fault occurs in the radial DL, a power outage of 3 to 5 minutes is occurring depending on the operator's proficiency and fault situation until the fault section is separated and the normal section is replaced. To solve this problem, Various methods have been proposed at domestic and foreign to solve this problem, and in Korea, research is underway on the advanced system of operating multiple linked DL always. A system that is electrically linked always, and that is built to enable high-speed communication during the protection coordination is named networked distribution system (NDS). Because the load shares the DL, the line utilization rate can be improved, and even if the line faults, the normal section does not need to be cut off, so the normal section does not experience a power outage. However, since it is impossible to predict in which direction the fault current will flow when a failure occurs in the NDS, a communication-based protection coordination is used, but there is no backup protection coordination method in case of communication failure. Therefore, in this paper, we propose a protective cooperation method to apply as a backup method when communication fails in NDS. The new method is to change TCC by location of CB using voltage drop in case of fault.

네트워크 배전계통용 통신기반 보호협조에 관한 연구 (A study of communication-based protection coordination for networked distribution system)

  • 김우현;채우규;황성욱;이학주
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제8권1호
    • /
    • pp.43-48
    • /
    • 2022
  • Although the distribution system has been structured as complicated as a mesh in the past, the connection points for each line are always kept open, so that it is operated as a radial distribution system (RDS). For RDS, the line utilization rate is determined according to the maximum load on the line, and the utilization rate is usually kept low. In addition, when a fault occurs in the RDS, a power outage of about 3 to 5 minutes occurs until the fault section is separated, and the healthy section is transferred to another line. To improve the disadvantages of the RDS, research on the construction of a networked distribution system (NDS) that linking multiple lines is in progress. Compared to the RDS, the NDS has advantages such as increased facility utilization, load leveling, self-healing, increased capacity connected to distributed generator, and resolution of terminal voltage drop. However, when a fault occurs in the network distribution system, fault current can flow in from all connected lines, and the direction of fault current varies depending on the fault point, so a high-precision fault current direction determination method and high-speed communication are required. Therefore, in this paper, we propose an accurate fault current direction determination method by comparing the peak value polarity of the fault current in the event of a fault, and a communication-based protection coordination method using this method.

MQTT 브로커 서버를 이용한 AC 22.9 kV 차단기/피뢰기의 4-채널 다중 접촉저항 측정 시스템 (The 4-channel Multiple Contact Resistance Measurement Systems using MQTT Broker Server for AC 22.9 kV COS/Lightning Arrester)

  • 부라윤;최정훈;이명의
    • 한국항행학회논문지
    • /
    • 제27권2호
    • /
    • pp.203-208
    • /
    • 2023
  • 본 연구에서는 정전류 회로와 전압 강하법을 이용한 접촉 저항 측정 회로의 정밀도를 개선하는 방법을 제안하고, MQTT 브로커 서버를 통해 접촉 저항 측정 시스템의 측정값을 모니터링할 수 있는 대시보드를 구현한다. 접촉 저항 측정 시스템은 저항값을 측정하고 무선통신을 이용해 MQTT 브로커 서버로 측정값을 전달하고, 대시보드는 Node-RED와 Node-RED-Dashboard을 이용하여 최대 4개의 접촉저항 측정 시스템의 저항값을 받아 이를 사용자 화면에 출력하여 보여준다. 사용자는 하나의 대시보드를 이용해 복수의 측정 데이터를 관리할 수 있고, MQTT 브로커 서버를 통해 다른 장치와 쉽게 인터페이스 가능하게 한다. 실제 데이터 측정을 통해 정밀도 상대표준편차가 평균적으로 40.37%, 그리고 최대 64.73% 각각 감소하여 정밀도의 개선 효과가 있다.