• 제목/요약/키워드: void filling

검색결과 84건 처리시간 0.019초

성견의 치주질환 이환 발치와에 이식된 활택치근과 탈회냉동건조골이 치조골재생에 미치는 영향 (EFFECT OF DECALCIFIED FREEZE-DRIED BONE ALLOGRAFTS AND ROOT PLANING PROCEDURE ON THE HEALING OF TRANSPLANTED ROOTS INTO THE PERIODONTALLY DISEASED EXTRACTION SOCKETS OF DOGS)

  • 김종관;채중규;조규성;문익상;김진;최상묵;한수부
    • Journal of Periodontal and Implant Science
    • /
    • 제25권3호
    • /
    • pp.557-567
    • /
    • 1995
  • The purpose of this study was to investigated the effect of root planing and decalcified freeze dried allografts on the resorption of transplanted roots and the healing of preveously diseased recipient extraction sockets. The experimental chronic periodontitis was induced by elastic ligatures on the 2nd and 3rd mandibular premolars of 4 adult dogs, and after 8 weeks, crowns were removed and the teeth extracted. The extracted roots were split in half along the long-axis, and the extednt of plaque exposure was morked on the root surfaces with burs. The roots were either root-planed(Test group), or left uninstrumented(Control group), and transplanted in the extraction sockets with decalcified freeze-dried allografts filling the void. The flaps were sutured to cover the sockets completely. The animals were sacrificed after 12 weeks of healing, and the specimens were examined histologically. The results were as follows : 1. No signs of inflammation or disease activity were observed in either groups. 2. Replacement root resorption was observed in both groups. 3. More connective tissue attachments and less ankylosis were observed in the test groups compared to the control. 4. The unresorbed remains of DFDB particles were observed in both groups. 5. DFDB particles in the apical portion of the alveolar sockets were encased in newly-formed bone, while those in the coronal areas were seen encapsulated with connective tissue. 6. No significant difference was found between root-planed and uninstrumented roots relative to the healing and the bone fromation in the recipient extraction sockdets. From the present study, there seemed to be no significant benefits in root planing the transplanted roots or grafting the sockets with DFDB in order to curve the replacement resorption, although the root-planed roots showed more connective tissue attachments. There was also no significant benefits in root transplantation and DFDB for and enhanced healing and bone formation in alveolar extraction sockets.

  • PDF

Formation and Characteristics of the Fluorocarbonated SiOF Film by $O_2$/FTES-Helicon Plasma CVD Method

  • Kyoung-Suk Oh;Min-Sung Kang;Chi-Kyu Choi;Seok-Min Yun
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 1998년도 제14회 학술발표회 논문개요집
    • /
    • pp.77-77
    • /
    • 1998
  • Present silicon dioxide (SiOz) 떠m as intennetal dielectridIMD) layers will result in high parasitic c capacitance and crosstalk interference in 비gh density devices. Low dielectric materials such as f f1uorina뼈 silicon oxide(SiOF) and f1uoropolymer IMD layers have been tried to s이ve this problem. I In the SiOF ftlm, as fluorine concentration increases the dielectric constant of t뼈 film decreases but i it becomes unstable and wa않r absorptivity increases. The dielectric constant above 3.0 is obtain어 i in these ftlms. Fluoropolymers such as polyte$\sigma$따luoroethylene(PTFE) are known as low dielectric c constant (>2.0) materials. However, their $\alpha$)Or thermal stability and low adhesive fa$\pi$e have h hindered 야1리ru뚱 as IMD ma따"ials. 1 The concept of a plasma processing a찌Jaratus with 비gh density plasma at low pressure has r received much attention for deposition because films made in these plasma reactors have many a advantages such as go여 film quality and gap filling profile. High ion flux with low ion energy in m the high density plasma make the low contamination and go어 $\sigma$'Oss피lked ftlm. Especially the h helicon plasma reactor have attractive features for ftlm deposition 야~au똥 of i앙 high density plasma p production compared with other conventional type plasma soun:es. I In this pa야Jr, we present the results on the low dielectric constant fluorocarbonated-SiOF film d밑JOsited on p-Si(loo) 5 inch silicon substrates with 00% of 0dFTES gas mixture and 20% of Ar g gas in a helicon plasma reactor. High density 띠asma is generated in the conventional helicon p plasma soun:e with Nagoya type ill antenna, 5-15 MHz and 1 kW RF power, 700 Gauss of m magnetic field, and 1.5 mTorr of pressure. The electron density and temperature of the 0dFTES d discharge are measUI벼 by Langmuir probe. The relative density of radicals are measured by optic허 e emission spe따'Oscopy(OES). Chemical bonding structure 3I피 atomic concentration 따'C characterized u using fourier transform infrared(FTIR) s야3띠"Oscopy and X -ray photonelectron spl:’따'Oscopy (XPS). D Dielectric constant is measured using a metal insulator semiconductor (MIS;AVO.4 $\mu$ m thick f fIlmlp-SD s$\sigma$ucture. A chemical stoichiome$\sigma$y of 야Ie fluorocarbina$textsc{k}$영-SiOF film 따~si야영 at room temperature, which t the flow rate of Oz and FTES gas is Isccm and 6sccm, res야~tvely, is form려 야Ie SiouFo.36Co.14. A d dielec$\sigma$ic constant of this fIlm is 2.8, but the s$\alpha$'!Cimen at annealed 5OOt: is obtain려 3.24, and the s stepcoverage in the 0.4 $\mu$ m and 0.5 $\mu$ m pattern 킹'C above 92% and 91% without void, res야~tively. res야~tively.

  • PDF

VCUG 보조기구의 임상적 유용성에 관한 고찰 (VCUG Studies on the Clinical Usefulness of Aids)

  • 최대연;김동현
    • 한국방사선학회논문지
    • /
    • 제9권7호
    • /
    • pp.529-533
    • /
    • 2015
  • VCUG 검사는 검사 중 배뇨를 해야 하기 때문에 하의를 벗은 상태에서 실시해야 해서 환자의 민망함과 불안감이 매우 큰 투시검사 중 하나이다. VCUG 검사는 배뇨 중 방광요관역류(VUR:Vesico Urthral Reflex)를 진단하기 위해서는 검사자와 의사가 배뇨의 전 과정을 지켜봐야 하고 환자가 직접 소변통을 들고 배뇨를 하면서 검사를 해야 하기 때문에 VCUG 검사 자체가 상당히 불편하다. 따라서 이러한 VCUG 검사는 환자의 인격을 고려한다면 향후 지양해야 할 검사이기도 하다. 그러나 이러한 VCUG 검사는 의료 비뇨기학적 진단에서 상당한 가치가 있고 아직까지 VCUG를 대체할 만한 검사법이 개발되지 않고 있다. 이에 VCUG 검사를 시행할 때 환자의 인격을 존중하고 환자의 민망함과 불안감을 감소시킬 수 있는 방안으로 VCUG 검사 팬티를 자체 제작하였고 VCUG 검사팬티를 사용한 실험군과 사용하지 않은 대조군들을 두 분류로 나누어 VCUG 검사 시간, 검사에 따른 환자가 받는 피폭 선량 그리고 환자 만족도를 비교 분석해 보았다. VCUG 검사 시간은 VCUG 팬티를 사용한 실험군이 27.8분, 대조군이 35.3분으로 실험군이 대조군에 비해 검사시간이 7.5분 단축되었다. 환자 피폭선량은 VCUG 검사 팬티를 사용한 실험군이 $3411.9{\mu}Gym^2$, 대조군이 $4566.6{\mu}Gym^2$으로 실험군이 피폭선량을 평균 $1154.7{\mu}Gym^2$를 감소시킬 수 있었다. 실험군과 대조군의 검사만족도 평가에서는 대조군 1.86에 비해 실험군 3.05로 실험군의 만족도가 매우 높았고 검사 중 수치심의 정도는 대조군 4.02에 비해 실험군 3.08로 수치심이 감소하는 것을 확인 할 수 있었다. 검사 중 불안감을 느끼는 정도는 대조군 3.45에 비해 실험군 2.51로 불안감을 적게 느끼는 것으로 나타났으며 배뇨가 잘 되는 정도는 대조군 1.90에 비해 실험군 2.84로 나타나 VCUG 검사 팬티를 사용함으로써 배뇨가 더 잘되는 것으로 나타났다. 따라서 VCUG 검사 팬티를 사용함으로써 검사시간과 환자의 피폭 선량이 단축되었으며 환자의 만족도 또한 향상되었다.

다짐말뚝 재료로서 쇄석과 저회의 적정 혼합비 도출을 위한 실험적 연구 (Experimental Study for the Development of the Mixing Ratio as a Compaction Pile)

  • 임한수;김선곤;이주호;천병식
    • 한국지반환경공학회 논문집
    • /
    • 제13권9호
    • /
    • pp.5-16
    • /
    • 2012
  • 원지반을 절토하여 생성된 토질재료를 입도조절 없이 곧바로 성토재료로 사용하는 경우, 성토의 설계나 밀도관리를 위해 필요한 다짐특성이나 재료정수는 실내시험을 통해 구하는 것이 바람직하며, 이에 대한 연구가 수행되어 왔다. 그러나 선행된 연구는 주로 자연상태에 존재하는 입경이 상이한 혼합재료에 관련된 것으로, 최근 건설재료로 활발히 연구되고 있는 화력발전소 부산물인 석탄회를 활용한 연구는 전무한 실정이다. 따라서 본 연구에서는 쇄석과 화력발전소에서 부산되는 저회를 혼합한 재료의 다짐에 의한 입자파쇄가 재료의 압축특성에 미치는 영향을 규명하기 위하여 다짐시험을 실시하여 기본적인 공학적 성질을 파악하였고, 일차원압축시험을 실시하여 다짐특성과 재료특성에 미치는 각 재료 혼합량의 영향을 파악하였다. 다짐시험 결과, 저회의 최적함수 비는 약 23%로 나타났고, 동일한 다짐에너지 및 함수비로 저회와 쇄석의 혼합비에 따른 다짐시험 결과 저회의 혼합율이 30%를 넘어서면 건조단위중량은 감소되는 경향을 나타내었고, 혼합율이 30%일 때 건조단위중량이 약 $1.81gf/cm^3$로 나타났다. 쇄석과 저회 의 혼합비에 따른 일차원압축시험 결과, 저회 100%의 경우 입자파쇄에 의한 간극비 변화가 가장 크게 나타났고, 쇄석 100%의 경우 가장 작게 나타났다. 쇄석과 저회 혼합재료의 경우, 저회 30%에서 압축지수가 가장 작게 나타나 혼합재료로서 공학적으로 가장 안정한 혼합비로 예상되었다.