• Title/Summary/Keyword: vital signs

Search Result 553, Processing Time 0.023 seconds

A Case of Moderate Paraquat Intoxication with Pulse Therapy in the Subacute Stage of Pulmonary Fibrosis (파라쿼트로 발생한 폐 섬유화증에서 pulse therapy로 호전된 환자 1례)

  • Hong, Ki-Hun;Jung, Jin-Hee;Eo, Eun-Kyung
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.6 no.2
    • /
    • pp.130-133
    • /
    • 2008
  • In South Korea, attempted suicide by paraquat (PQ) intoxication is fairly common, and is lethal by pulmonary fibrosis and hypoxemia. However, the treatment of PQ poisoning is primarily supportive management. To increase the survival rate associated with PQ intoxication, many treatments have been developed. Here, we treated a case of PQ intoxication with steroid pulse therapy. A 23-year-old man was admitted to the hospital because of PQ intoxication. He drank two mouthfuls of Gramoxon (24% commercial paraquat). His vital signs were stable, but he had a throat infection, and navy blue urine in the sodium dithionite test. Standard treatment, including gastric lavage with activated charcoal was performed, and emergent hemoperfusion with a charcoal filter was initiated 11 h after PQ ingestion. Pharmacotherapy was initiated 18 h after PQ ingestion with the administration of 5 mg dexamethasone. On day 10, chest PA showed pulmonary fibrosis. Therefore, we initiated steroid pulse therapy, with 1g methylprednisolone in 100 mL of D5W administered over 1 h repeated daily for 3 days, and 1 g cyclophosphamide in 100 mL of D5W administered over 1 h daily for 2 days. On day 15, dexamethasone therapy was initiated. On day 30, pulmonary fibrosis was improved. Thus, if pulmonary fibrosis becomes exacerbated after dexamethasone therapy during the subacute stage, pulse therapy with methylprednisolone and cyclophosphamide could be helpful.

  • PDF

Practice Status of Dental Hygiene Assessment in Dental Clinic (치과 임상에서의 치위생사정 수행 실태)

  • Park, Bo-Young;Yoon, Mi-Suk
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.12
    • /
    • pp.139-144
    • /
    • 2021
  • This study was conducted to investigate practice rate of dental hygiene assessment and to understand the performance ratio according to hospital type. A questionnaire survey was conducted on 195 dental hygienists, and the dental hygiene assessment items examined were 6 types of dental history, medical history, vital signs measurement, extraoral examination, intraoral soft tissue examination, andtissue examination. As a result of the study, the item with the highest percentage of performers was 92.8% of dental history, and the lowest item was extraoral examination 57.9%. And, dental clinics were higher than dental hospitals and university hospitals in all dental hygiene assessment categories, and in particular, performance rates of extraoral examination and intraoral soft tissue examination were higher in dental clinics. Considering the overall high rate of dental hygiene assessment through this study, it is necessary to discuss the legal work of dental hygienists and to reflect the insurance fee.

Cow Residual Feed Intake(RFI) monitoring and metabolic abnormality prediction system using wearable device for Milk cow and Beef

  • Chang, Jin-Wook;Kwak, Ho-Young
    • Journal of the Korea Society of Computer and Information
    • /
    • v.26 no.10
    • /
    • pp.139-145
    • /
    • 2021
  • In this paper, by using the cattle feed intake, rumination, and in heat monitoring technology, RFI (Residual Feed Intake) monitoring and wearable devices and PCs for predicting abnormalities in budding target web and smart A monitoring system using a phone application was designed and implemented. With the development of this system, the farmer is expected to increase economic efficiency. By analyzing the feed intake, it is possible to identify the difference between the recommended feed amount based on the cow's weight and the feed amount consumed by the cow, and it is expected that early detection of metabolic disorders (abnormality of metabolism) is possible. Farmers using the results of this thesis can distinguish the cows with the most efficient performance, and the 6-axis motion sensor signals input from the wearable device attached to the cow's skin (neck) and the microphone attached to the wearable device. It is possible to measure the cow's rumination and feed intake through the sound of the cow's throat. In the future, improvements will be made to measure additional vital signs such as heart rate and respiration.

Study on Data Normalization and Representation for Quantitative Analysis of EEG Signals (뇌파 신호의 정량적 분석을 위한 데이터 정규화 및 표현기법 연구)

  • Hwang, Taehun;Kim, Jin Heon
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.9 no.6
    • /
    • pp.729-738
    • /
    • 2019
  • Recently, we aim to improve the quality of virtual reality contents based on quantitative analysis results of emotions through combination of emotional recognition field and virtual reality field. Emotions are analyzed based on the participant's vital signs. Much research has been done in terms of signal analysis, but the methodology for quantifying emotions has not been fully discussed. In this paper, we propose a normalization function design and expression method to quantify the emotion between various bio - signals. Use the Brute force algorithm to find the optimal parameters of the normalization function and improve the confidence score of the parameters found using the true and false scores defined in this paper. As a result, it is possible to automate the parameter determination of the bio-signal normalization function depending on the experience, and the emotion can be analyzed quantitatively based on this.

Risk Factors of Delirium in ICU Patients with Acute Poisoning (중환자실 급성중독환자에서 섬망의 위험인자)

  • Kim, Hee Yeon;Cha, Kyung Man;So, Byung Hak
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.17 no.1
    • /
    • pp.14-20
    • /
    • 2019
  • Purpose: This study estimated the incidence of delirium and associated risk factors and outcomes in ICU patients with acute poisoning. Methods: Data were collected from ICU patients over 18 years of age that were admitted via the emergency center after presenting with poisoning from 2010 to 2015. Delirium was assessed retrospectively using the Intensive Care Delirium Screening Checklist (ICDSC). Risk factors were evaluated by univariate and multivariate analysis. Results: A total of 199 patients participated in this study and 68 (34.2%) were diagnosed with delirium based on the ICDSC score. The delirium group showed a significantly higher association with prolonged length of stay in the hospital and ICU in comparison with the non-delirium group. The delirium group was associated with greater use of physical restraint. A statistically greater number of patients with pharmaceutical substance poisoning developed delirium over a short period of time than those with non-pharmaceutical substance poisoning. There was no significant difference between the two groups with respect to age, sex, past history, GCS score, vital signs, application of ventilator care and renal replacement therapy. Conclusion: The finding that the delirium group had a greater length of stay in both the hospital and the ICU is consistent with the results of previous worldwide studies of the effects of delirium on the prognosis of patients who were admitted to the ICU, suggesting the possibility for domestic application. Additionally, use of physical restraint was positively related to the incidence of delirium. Thus, interventions for minimizing the use of physical restraints and considering alternatives are needed.

Considerations for dental treatment of Williams syndrome patients (윌리엄스 신드롬 환자의 치과치료를 위한 고려사항)

  • Shin, Jisun;Lee, Joonhaeng
    • Journal of Korean Academy of Oral Health
    • /
    • v.42 no.4
    • /
    • pp.238-241
    • /
    • 2018
  • Williams syndrome is a rare congenital disorder with various physical abnormalities and characterized by facial, oral, and dental features. Individuals with Williams syndrome typically have eating disorders in the early childhood, which lead to prolonged night feeding. Prolonged night feeding is a risk factor for rampant dental caries. Williams syndrome is caused by the microdeletion of chromosome 7, resulting in elastin deficiency. Elastin is integral to cardiovascular health. Many patients with Williams syndrome have complex cardiovascular abnormalities that must be considered a part of dental management. Complications related to cardiovascular diseases may induce adverse effects such as dangerously elevated blood pressure. This may occur in patients during stressful dental treatment. In addition, characteristics of auditory hyperalgesia and anxiety disorders among patients with William syndrome, complicate receiving routine dental management. Therefore, dental treatment under sedation or general anesthesia may be preferable for patients with Williams syndrome; in particular, patients who are very uncooperative and/or needs extensive dental treatment. A thorough evaluation of each patient's physical condition is required before making decisions regarding dental treatment. Careful monitoring and preparation for emergencies are very important during and shortly after dental treatment under general anesthesia or sedation. Monitoring is critical until vital signs have stabilized and return to normal. A 28-month-old man diagnosed as having Williams syndrome, visited the Dental Hospital of ${\bigcirc}{\bigcirc}$ University for the management of rampant dental caries. We reported on the management of this patient who had peripheral pulmonic stenosis, and received dental treatment under general anesthesia. We also reviewed the characteristics of Williams syndrome and discussed considerations for dental treatment under general anesthesia.

Surgically induced degenerative changes in the femorotibial joints by total medial meniscectomy in minipigs closely resemble late-stage osteoarthritis

  • Lee, Won-Jae;Park, Byung-Joon;Lee, Hyeon-Jeong;Jang, Si-Jung;Lee, Sung-Lim;Lee, Jae-Hoon;Rho, Gyu-Jin;Kim, Seung-Joon
    • Korean Journal of Veterinary Research
    • /
    • v.59 no.1
    • /
    • pp.17-24
    • /
    • 2019
  • Animal models of osteoarthritis (OA) have played a key role in understanding the etiology of OA and in the development of new therapeutic strategies. Although pigs have an advantage as an animal disease model due to their similarity to humans, there are few studies on the induction of OA in minipigs. Therefore, this study aimed to characterize disease progression of OA in total medial meniscectomy (TMM)-operated skeletally mature minipigs, up to day 180 postoperatively. There were no significant alterations in vital signs or hematological indices throughout the observation period. However, clinical manifestations of OA in the medial femoral condyles of TMM-operated minipigs were progressive, depending on postoperative duration, with respect to osteophytes formation and roughened surfaces on radiological observation, cartilage erosion under macroscopic examination, and severe cartilage defects including fibrillation, vertical fissures, and cartilage denuding on histopathological observation, with the highest score indicating late-stage OA on day 180 and without indicating apparent variation between subjects. In particular, the lateral femoral condyles were also degenerated, possibly due to localization of weight-bearing from both menisci to the lateral meniscus. Therefore, TMM in minipigs is suitable for reproducible induction of degenerative changes in the femorotibial joints that closely resemble late-stage OA, and is suitable for use in further research.

The clinical characteristics and prognosis of subgaleal hemorrhage in newborn

  • Lee, Sun Jin;Kim, Jin Kyu;Kim, Sun Jun
    • Clinical and Experimental Pediatrics
    • /
    • v.61 no.12
    • /
    • pp.387-391
    • /
    • 2018
  • Purpose: Subgaleal hemorrhage (SGH) is a rare but potentially fatal condition in newborns; however, few studies have reported on this condition. We aimed to identify the clinical characteristics and prognostic factors of SGH. Methods: We retrospectively reviewed the medical records of 20 neonates diagnosed with SGH between January 2000 and June 2017. Enrolled neonates were clinically diagnosed when they had tender fluctuant scalp swelling that crossed the suture lines. Results: Among 20 neonates with SGH, 12 were boys and 7 were girls; median hospitalization duration was $9.7{\pm}6.9days$. Fourteen neonates (70%) were born via vacuum-assisted vaginal delivery, and 4 via vacuum-assisted cesarean section. Of the neonates enrolled, half of them initially showed unstable vital signs, including apnea, desaturation, and cyanosis. Ten neonates had acidosis and 3 had asphyxia (pH<7.0). Intracranial lesions associated with SGH were observed in 15 neonates (75%), including subdural hemorrhage (50%), subarachnoid hemorrhage (15%), intraventricular hemorrhage (5%), cerebral infarct (15%), skull fracture (30%), and cephalohematoma (20%). Twelve neonates (60%) required transfusion, 5 (25%) had seizures, and 3 (15%) died. Eight neonates (40%) had hyperbilirubinemia (mean total bilirubin, $13.1{\pm}7.4$). The mean follow-up period was $8.4{\pm}7.5months$. At follow-up, 10 neonates (58.8%) were healthy with normal development, whereas 7 (41.2%) had neurological deficits. Conclusion: The morbidity rate was 41.2% due to severe metabolic acidosis. Anemia, hyperbilirubinemia, low Apgar scores, and subdural hemorrhage did not affect the prognosis. The long-term outcomes of neonates with SGH are generally good. Only arterial blood pH was significantly associated with death.

Clinical effects of veno-venous extra-corporeal membrane oxygenation for acute myocardial infarction (급성심근경색 환자에게 적용된 정맥-정맥 체외막산화기의 임상 효과)

  • Kim, Su Wan;Seong, Gil Myeong;Lee, Jae-Geun
    • Journal of Medicine and Life Science
    • /
    • v.15 no.2
    • /
    • pp.108-111
    • /
    • 2018
  • Extra-corporeal membrane oxygenation (ECMO) has the potential to rescue patients in cardiac arrest or respiratory failure. ECMO has two systems such as veno-arterial and veno-venous circulation. In cardiac arrest resulting from acute myocardial infarction, veno-arterial ECMO is mandatory for systemic circulation and oxygenation. A 75-year old female patient underwent primary coronary intervention for acute myocardial infarction. Despite successful revascularization, recurrent ventricular tachycardia and heart failure were progressing. We performed a veno-arterial ECMO through the femoral artery and vein, then the patient seemed to be stable clinically. However, laboratory studies, echocardiography, and vital signs indicated multi-organ failure and decreasing cardiac function. We found out an error that we performed veno-venous ECMO instead of veno-arterial ECMO. We added a femoral artery cannula and exchange the circuit system to veno-arterial ECMO. While the systemic circulation seemed to be recovered, the left ventricular function was decreased persistently. A hypovolemia resulting from pulmonary hemorrhage was occurred, which lead to ECMO failure. The patient died of cardiac arrest and multi-organ failure 23 hours after ECMO. Because the color of arterial and venous circuits represent the position and efficacy of ECMO, if unexpected or abnormal circuit colors are detected, prompt and aggressive evaluation for ECMO function is mandatory.

Development of PVDF sensor and system to detect breathing sounds during deep sedation (진정 마취 시 호흡음 검출을 위한 PVDF 센서 및 시스템 개발)

  • Lee, Seung-Hwan;Li, Xiong;Im, Jae-Joong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.1
    • /
    • pp.153-159
    • /
    • 2019
  • Respiration is one of the important vital signs to determine the condition of the patient. Especially during deep sedation, since the patient's apnea and hypopnea are difficult to detect without continuous monitoring, there is a need for a continuous respiration monitoring method that can accurately and simply determine the patient's respiratory condition. Currently, respiration monitoring methods using various devices have been developed, but these methods have not only late response time but also low reliability at the clinical stage. In this study, attachable sensor using PVDF(polyvinylidene fluoride) film and a monitoring device which could detect abnormal symptoms of breathing in early stage during deep sedation. The results of this study can be used in various medical fields including not only in the area of remote monitoring for respiration related sleep monitoring but also in routine monitoring during deep sedation.