Effect of Test Zone Selection for Evaluating Bending Strength of Lumber

  • Pang, Sung-Jun;Lee, Jun-Jae;Oh, Jung-Kwon
    • Journal of the Korean Wood Science and Technology
    • /
    • 제41권5호
    • /
    • pp.392-398
    • /
    • 2013
  • This study investigated the effect of test zone selection for evaluating bending strength of visually graded lumber. This will contribute to the understanding of two different methods under different standards. In method I, the major defect was randomly placed in the test specimen. In method II, the major defect was randomly placed in the maximum moment zone (MMZ). The results showed that the method II is more accurate for reflecting the effect of defects governing the grade of lumber. Unless the maximum strength-reducing defect (MSRD) is placed in MMZ, the evaluated value would be higher than that of MSRD. For evaluating the modulus of rupture (MOR) of visually graded lumber in test set-up of Method I, the Eq. (5) needs to be considered.

국산 침엽수구조재의 허용응력설정에 관하여 - 1종 구조재를 중심으로 - (Assignment of the Allowable Design Values for Domestic Softwood Structural Lumber - Structural I-grade -)

  • 오세창
    • Journal of the Korean Wood Science and Technology
    • /
    • 제24권1호
    • /
    • pp.11-16
    • /
    • 1996
  • The purpose of this paper is to present a summary of assignment design values according to domestic softwood structural lumber grading rules. Allowable stresses for visually graded lumber were determined from basic data on small. clear specimens. The data corrected for variability such as natural defects and other factors. The procedure adopted by Japan was used for assigning allowable design values. Strength ratios in relation to each defect were taken from ASTM D 245-81. Korean pine(Pinus koraiensis S. et Z.), Korean red pine(Pinus densiflora S. et Z.), Japanese larch(Larix leptolepis Gordon) and Needle fir(Abies holophylla Max) were applied to this study. The calculated allowable stresses were same in Korean pine and Korean red pine. These values were highest in Japanese larch lowest in Needle fir. So, it is desirable for these species to be classified into different catagories Species Group. However, accurate comparison in design values on lumber grading rules among U.S., Japan and Korea was somewhat difficult. And full scale testing will be necessary for accurate determination of the correction factors to setting up design values.

  • PDF

4점 휨 시험에서 지간 거리에 따른 2×4 낙엽송 제재목의 휨 성능 변화 (Change of Bending Properties of 2×4 Larch Lumber According to Span Length in the Four Point Bending Test)

  • Kim, Chul-Ki;Kim, Kwang-Mo;Lee, Sang-Joon;Park, Moon-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • 제46권5호
    • /
    • pp.486-496
    • /
    • 2018
  • 4점 휨 시험에서 지간 길이에 따른 낙엽송 제재목의 휨 성능 변화를 알아보기 위하여 연구를 진행하였다. 연구에 사용된 시험편의 크기는 38(너비) ${\times}$ 89(깊이) ${\times}$ 3,600(길이) $mm^3$이며, 평균 기건 밀도와 함수율은 각각 $543.5kg/m^3$, 10.5%이었다. 낙엽송 육안 등급 1등급 248본을 두 그룹으로 나눠, 지간 거리 1,650 mm와 3,000 mm에서 휨 실험을 진행하여 휨 강도와 휨 탄성계수를 도출하였다. 휨 탄성계수는 유의 수준 5%에서 지간 거리에 따라 차이가 없다고 판단된 반면 휨 강도는 차이가 있었으며, 지간에 반비례하였다. 지간 거리 1,650와 3,000 mm에서 휨 강도의 5% 하한치는 각각 28.65와 25.70 MPa로 확인되었다. 지간 거리에 따른 휨 강도 차이는 백분위 수가 증가함에 따라 커지는 것으로 확인되었으며, 이는 와이블 최약 링크 파손 이론에 의한 치수 효과 때문으로 사료된다. 따라서 지간 대 깊이 비가 15 이상으로만 제한되어 있는 목구조용 실대재 휨 시험법(KS F 2150)에 치수 효과를 고려할 수 있는 방법이 포함되어야 할 것으로 판단된다. 이를 통해 다양한 치수의 제재목에서 얻어지는 강도를 설계 값에 반영할 수 있을 것으로 기대된다.