• Title/Summary/Keyword: visual measurement

Search Result 930, Processing Time 0.03 seconds

The Effect of Environmental Factors upon Children's Visual Acuity (어린이 시력과 생활 환경과의 관계에 관한 연구)

  • Kang, H.S.;Seo, Y.W.;Kang, I.S.
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.2 no.1
    • /
    • pp.77-83
    • /
    • 1997
  • This study was carried out to investigate the effect of environmental factors on 380 children's unaided visual acuity and to determine the visual acuity and objective refraction error of these children. The unaided visual acuity and objective refraction error were measured by the TOPCON chart projector and refractometer on 147 kindergarteners and 233 primary school children ranging from age 5 to 12. The measurement on the unaided visual acuity of children were 3% for below the 0.1 visual acuity 9% for 0.1~0.4. 18% for 0.5~0.7. 16% for 0.8~0.9. and 54% for over 1.0 visual acuity respectively. The refractive errors were 9.35% for mixed astigmatism. 14.5% for hyperopia 75.88% for myopia. and 0.27% for emmetropia. respectively. When analyzing the environmental factors. the relationship between the children's visual acuity and the number of hours the children watched TV. the more hours they watched TV. the more the children lost their visual acuity. The visual acuity of children decreased abruptly in the groups that watched TV more than 4 hour a day. When comparing the relationship between the children's visual acuity and proximity to the TV, the further away from the TV they were the higher visual acuity. There is rna relation between the children's visual acuity and the studying hour or reading hour of children. The relationship between the children's visual acuity and their dwelling environment, the visual acuity of children who lived in an independent house were better than the visual acuity of children who dwelled in an apartment.

  • PDF

An Algorithm for Discontinuous Surface Profile Measurement using Wavelength Scanning Interferometer (파장 주사 간섭계를 이용한 불연속면의 표면 형상 측정 알고리즘)

  • 우현구;강철무;조형석
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.7
    • /
    • pp.507-514
    • /
    • 2003
  • Inspection and shape measurement of three-dimensional objects are widely needed in industries for quality monitoring and control. Recently the shape measurement using interferometric principle is found to be a successful methodology among other visual or optical technologies. Especially, the measuring method using wavelength scanning interferometer(WSI) has a great advantage in comparison with other conventional jnterferometric methods in that the absolute distance from the reference surface can be directly obtained from the amount of jnterferometric phase change. However, the measurement methods using WSI proposed by other researchers have low measurement resolution so far because they can't measure fractional phase change. To avoid this shortcoming we propose a new algorithm in this paper, which can obtain a small amount of even fractional phase change by sinusoidal function fitting. To evaluate the effectiveness of the proposed sinusoidal function fitting algorithm, a series of measuring experiments are conducted for discontinuously shaped specimens which have various height. The proposed algorithm shows much more enhanced measurement resolution than other existing conventional algorithms such as zero crossing algorithm and Fourier transform algorithm.

Cathodic Protection Behavior of Coastal Bridge Structure with Sacrificial Anode Cathodic Protection System (희생양극식 음극방식이 적용된 해안 교량 구조물의 방식거동)

  • Ha, Ji-Myung;Jin, Chung-Kuk;Jeong, Jin-A
    • Corrosion Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.242-246
    • /
    • 2012
  • This measurement represents the effectiveness of sacrificial anode cathodic protection (SACP) system in a coastal bridge structure. To verify the cathodic protection (CP) effect, the monitoring sensor (DMS-100) that could measure potential, corrosion rate, current, concrete resistivity, and temperature was embedded. The measurement conducted for three years after CP system was installed. Specifically, due to the fact that fresh water and sea water was repeated in the bridge structure, this bridge structure presented special CP behavior. Measurement factors were CP potential, CP current, concrete resistivity, and depolarization potential. In addition, visual inspection was also carried out. As a result of current and depolarization measurement, CP system was well activated in most piers.

Expectation of Astigmatism by Spherical Equivalent Visual Acuity (등가구면 시력으로부터 난시량의 예측)

  • Kim, Sang-Yoeb;Moon, Byeong-Yeon;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.167-170
    • /
    • 2011
  • Purpose: This study was tried whether expectation of astigmatism from spherical equivalent visual acuity was possible. Methods: For 54 men and women (108 eyes) corrected to emmetropia, average age of 23.3, changes of visual acuity (5m) were measured with an increasing the powers at every ${\pm}$0.25D when the (-) axis of cross cylinder is $180^{\circ}$, $90^{\circ}$, and $45^{\circ}$, respectively. Results: As the power of cross cylinder was increased, visual acuity was decreased. When the powers of cross cylinder were ${\pm}$2.50D ($180^{\circ}$ and $90^{\circ}$) and ${\pm}$2.25D ($45^{\circ}$), visual acuity was 0.05 which is the minimum measurement possible. Conclusions: The diagram on astigmatism dealing with each spherical equivalent visual acuity was able to tabulate.

The Effect of Activities of Daily Living(ADL) Training on the Visual Perception Capacity Performance Function of the Stroke (일상생활활동 훈련이 뇌졸중 환자의 시지각 기능에 미치는 효과)

  • Kim, Jiwon;Kim, Miyoung;Hwang, Bosun;Jang, Chel
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.2 no.1
    • /
    • pp.1-14
    • /
    • 2014
  • Purpose : The aim of this study was to investigate Activities of Daily Living(ADL) function recovery of repeated measurement of stroke who received ADL training. Method : Twenty stroke patients were treated by ADL program therapy from May to June. All of in twenty stroke patients, 10 stroke patients take part in Occupational Therapy and 10 stroke patients take part in ADL training for 30 min five times a week during four weeks in M- hospital occupational Therapy treatment room, local in Changwon and Geoje. We used two assessment on is Motor Free Visual Perception Test-Third Edition(MVPT-3) for visual perception the other is Modified Barthel Index(MBI) for ADL. Result : First, Visual Short Term Memory(VSTM) score was changed statistical significance OT intervention group than compare with ADL training group(p<.05). Second, Visaul Closure(VC) score was changed statistical significance OT intervention group than compare with ADL training group(p<.05). Third, Spatial Orientation(SO) score was changed statistical significance OT intervention group than compare with ADL training group(p<.05). The fourth Motor Free Visual Perception Test-Third Edition(MVPT-3) score was changed statistical significance OT intervention group than compare with ADL training group(p<.05). The fifth Modified Barthel Index(MBI total) score was changed statistical significance OT intervention group than compare with ADL training group(p<.05). Conclusion : Therefore, ADL training can be on method the visual perception of stroke patients.

Effects of Postural Control Training Using a Visual Blind Board on Head Control, Trunk Control, and the Sitting Abilities of Children with Moderate to Severe Cerebral Palsy: A Pilot Study (시야 가림막을 활용한 자세 조절 훈련이 중등도-중증 뇌성마비 아동의 머리 조절, 몸통 조절, 앉기 능력에 미치는 효과: 예비연구)

  • Kim, Kun-Woo;Lee, Min-Goo;Hahm, Suk-Chan
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.17 no.3
    • /
    • pp.31-40
    • /
    • 2022
  • PURPOSE: This study was conducted to investigate the effects of postural control training using a visual blind board, on head control, trunk control, and the sitting abilities of children with moderate-to-severe cerebral palsy. METHODS: Ten children with moderate to severe cerebral palsy participated in this study. Postural control training with a visual blind board was given for 40 minutes per session, 3 times a week for 4 weeks (12 sessions). Before and after the intervention, head control, trunk control, and sitting abilities were quantified using the head control scale, Korean version-trunk control measurement scale, and the sitting part of the Korean version-gross motor function measure-88, respectively. RESULTS: Postural control with the visual blind board significantly improved the head control ability of children with moderate to severe cerebral palsy (p = .015). Their trunk control abilities also showed significant improvement after the intervention (p = .016). However, their sitting ability did not show a significant change. CONCLUSION: These results showed that postural control training using a visual blind board is effective in improving the head and trunk control abilities of children with cerebral palsy. Further studies with suitable sample sizes and control groups are needed to reach a conclusion about the use of postural control training with visual blind boards for improvement of postural control of children with moderate to severe cerebral palsy.

The Effect of Motion Recognition Occupational Therapy on the Physical Self-efficacy, and Visual-motor Integration, Interactive Peer Play of Children with Neurodevelopmental Disorders (모션 인식 활용 작업치료가 신경발달장애 아동의 신체적 자기효능감 및 시각-운동통합 능력, 놀이기술에 미치는 영향)

  • Kim, Ko-Un;Oh, Hye-Won
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.10 no.1
    • /
    • pp.119-128
    • /
    • 2022
  • Purpose : The purpose of this study was to examine the effects of applying occupational therapy that uses motion recognition on the physical self-efficacy, visual-motor integration ability, and play skills of children who have neurodevelopmental disorder before and after treatment. Methods : This The study chose 16 children with neurodevelopmental disorder as research subjects who were randomly and evenly allocated into an experimental group and a control group. The experiment followed a pretest-posttest design. As an intervention, the experimental group received motion recognition-based occupational therapy and a separate sensory integration program. The control group only participated in the separate sensory integration program. The eight-week experiment duration included 24 intervention sessions where the a 50-minute session was implemented three times a week for eight weeks. To compare the physical self-efficacy, visual-motor integration ability, and play skills before and after the intervention, measurement tools including the Physical self efficacy, Beery VMI-6, and Penn interactive peer play scale were used. All measured variables were analyzed and expressed as mean, standard deviation and percentage. Results : The motion recognition-based occupational therapy demonstrated a significant effect on improving the physical self-efficacy, visual-motor integration ability, and play skills of the experimental group. The intervention also caused a significant difference between the experimental group and control group in terms of the physical self-efficacy, visual-motor integration ability, and play skills. Conclusion : We confirmed the possibility motion recognition-based occupational therapy could be effective in improving the physical self-efficacy, visual-motor integration ability, and play skills for patients who have neurodevelopmental disorder. Based on the study result, further future studies are expected based on this study result that prove the application effect of the motion recognition-based occupational therapy using disabled and non- disabled children as subjects are expected in the future.

A study on the Modification of Fastness Formulae and the Measurement of Staining Fastness by CCM

  • Park, Ju-Young;Hong, Min-Gi;Lee, Nan-Hyeng;Kim, Sam-Soo;Hudson Samuel M.;Park, Sung-Su
    • Textile Coloration and Finishing
    • /
    • v.18 no.5 s.90
    • /
    • pp.80-87
    • /
    • 2006
  • A new fastness formula based on the CIEDE2000 color-difference formula was developed by B. Rigg and his coworkers. It is much simpler to calculate the staining fastness grade than the ISO 105-A04 fastness formula based on the CIELAB color-difference formula. Sample pair sets, which cover a wide color space range were accumulated from the NCS(Natural Color System) color book. for those sample pair sets, a visual measurement experiment and an instrumental measurement experiment of fastness grade were carried out. Each performance of the ISO 105-A43 fastness formula and newly developed fastness formula was compared through degree of agreement for visual measurement results. The newly developed fastness formula indicated improved performance for measuring fastness grade as it was confirmed that the performance of the current ISO fastness formula ISO 105-A04 for assessing staining, was inadequate for measuring fastness grade. Then the fastness formulae were examined more closely according to the particular color spaces and the correlation of hue, lightness and chroma for measuring staining fastness grade was also considered to recommend more improved fastness formula. By modifying the weighting functions of CIEDE2000, which is a basis of new fastness formula developed by B. Rigg, a modified fastness formula is proposed in this study.

Thirteen Weeks Repeated-dose Toxicity Study on Aconitum ciliare Decaisne Pharmacopuncture Solution in Mice (초오 약침액의 13주 반복 시술 독성에 관한 연구)

  • Lim, Sung Chul;Kim, Jae Soo;Lee, Bong Hyo;Lee, Hyun Jong;Lee, Hyun;Lee, Yun Kyu
    • Korean Journal of Acupuncture
    • /
    • v.35 no.3
    • /
    • pp.139-148
    • /
    • 2018
  • Objectives : This study was performed to examine the toxicity on the long term procedure of Aconitum ciliare Decaisne pharmacopuncture(ADP) solution. Methods : To evaluate the long term toxicity of 3 different repeated doses, 60, 150, and 300 mg/kg/day for 13 weeks were injected into BALB/c mice, respectively. The ADP solution was injected into near ST36 of the right leg and normal saline of the same volume was used for the vehicle control group. To evaluate the toxicity of 60, 150, and 300 mg/kg of repeated doses for 13 weeks, toxic symptoms, weight measurement, hematological test, blood biochemical test, visual examination and weight measurement of major organs, and histopathological test were conducted. Results : No significant changes in toxic symptoms, weight measurement, hematological test, blood biochemical test, visual examination and weight measurement of major organs, and histopathological test were observed in different doses of ADP solution treated groups compared to vehicle control group. Conclusions : As a result, repeated dose at a concentration of 300 mg/kg or less is considered to be not harmful for clinical treatment.

A Study on Applicability Evaluation of digital Photogrammetry for Settlement Measurement of Soil Contaminated with Heavy Metals (중금속으로 오염된 지반의 침하계측을 위한 수치사진측량의 적용성 평가)

  • Han, Jung-Geun;Park, Jeong-Jun;You, Seung-Kyong;Yun, Jung-Mann;Hong, Gigwon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.19 no.4
    • /
    • pp.85-93
    • /
    • 2020
  • This study describes the results of laboratory model test on settlement of soil contaminated with heavy metals, in order to evaluate the applicability of VMS to the measurement of gound settlements generated during the purification of contaminated soil. The measurement results for settlement of contaminated soil were compared using a 3D-Visual Monitoring System (VMS) based on digital photogrammetry and a total station. The test result showed that the settlement of the soil contaminated with heavy metals occurred a lot in the experimental condition in which the hydrophilic filter was applied. The minimum and maximum error ranges of VMS were calculated as ±0.36mm and ±0.87mm, respectively, and the error of VMS was satisfied in all experimental conditions. The average error rate of VMS was lower in the hydrophilic filter condition than in the hydrophobic filter condition. Therefore, it was evaluated that VMS can be applied to measure the settlement of contaminated soil.