• Title/Summary/Keyword: viscous resistance

Search Result 112, Processing Time 0.026 seconds

Unsteady RANS Analysis of the Hydrodynamic Response for a Ship with Forward Speed in Regular Wave (규칙파중 전진하는 선박의 유체역학적 응답에 대한 비정상 수치해석)

  • Park, Il-Ryong;Kim, Kwang-Soo;Kim, Jin;Van, Suak-Ho
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.45 no.1
    • /
    • pp.29-41
    • /
    • 2008
  • The present paper provides a CFD analysis of diffraction problem for a ship with forward speed using an unsteady RANS simulation method, a WAVIS code. The WAVIS viscous solver adopting a finite volume method has second order accuracy in time and field discretizaions for the RANS equations. A two phase level-set method and a realizable ${\kappa}-{\varepsilon}$ turbulence model are adopted to compute the free surface and to meet the turbulence closure, respectively. To validate the capability of the present numerical methods for the simulation of an unsteady progressive regular wave, computations are performed for three grid sets with refinement ratio of ${\sqrt{2}}$. The main simulation is performed for a DTMB5512 model with a forward speed in a regular head sea condition. Validation of the present numerical method is carried out by comparing the present CFD results with available unsteady experimental data published in the 2005 Tokyo CFD Workshop: resistance, heave force, pitch moment, unsteady free surface elevations and velocity fields.

Cyclic testing of chevron braced steel frames with IPE shear panels

  • Zahrai, Seyed Mehdi
    • Steel and Composite Structures
    • /
    • v.19 no.5
    • /
    • pp.1167-1184
    • /
    • 2015
  • Despite considerable life casualty and financial loss resulting from past earthquakes, many existing steel buildings are still seismically vulnerable as they have no lateral resistance or at least need some sort of retrofitting. Passive control methods with decreasing seismic demand and increasing ductility reduce rate of vulnerability of structures against earthquakes. One of the most effective and practical passive control methods is to use a shear panel system working as a ductile fuse in the structure. The shear Panel System, SPS, is located vertically between apex of two chevron braces and the flange of the floor beam. Seismic energy is highly dissipated through shear yielding of shear panel web while other elements of the structure remain almost elastic. In this paper, lateral behavior and related benefits of this system with narrow-flange link beams is experimentally investigated in chevron braced simple steel frames. For this purpose, five specimens with IPE (narrow-flange I section) shear panels were examined. All of the specimens showed high ductility and dissipated almost all input energy imposed to the structure. For example, maximum SPS shear distortion of 0.128-0.156 rad, overall ductility of 5.3-7.2, response modification factor of 7.1-11.2, and finally maximum equivalent viscous damping ratio of 35.5-40.2% in the last loading cycle corresponding to an average damping ratio of 26.7-30.6% were obtained. It was also shown that the beam, columns and braces remained elastic as expected. Considering this fact, by just changing the probably damaged shear panel pieces after earthquake, the structure can still be continuously used as another benefit of this proposed retrofitting system without the need to change the floor beam.

Wake Comparison between Model and Full Scale Ships Using CFD (CFD를 이용한 모형선과 실선 스케일의 반류 비교)

  • Yang, Hae-Uk;Kim, Byoung-Nam;Yoo, Jae-Hoon;Kim, Wu-Joan
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.47 no.2
    • /
    • pp.150-162
    • /
    • 2010
  • Assessment of hydrodynamic performance of a ship hull has been focused on a model ship rather than a full-scale ship. In order to design the propeller of a ship, model-scale wake is often extended to full-scale based upon an empirical method or designer's experience, since wake measurement data for a full-scale ship is very rare. Recently modern CFD tools made some success in reproducing wake field of a model ship, which implicates that there are some possibilities of the accurate prediction of full-scale wakes. In this paper firstly the evaluation of model-scale wake obtained by Fluent package was performed. It was found that CFD calculation with the Reynolds-stress model (RSM) provided much better agreement with wake measurement in the towing tank than with the realizable k-$\varepsilon$ model (RKE). In the next full-scale wake was calculated using the same package to find out the difference between model and full-scale wakes. Three hull forms of KLNG, KCS, KVLCC2 having measurement data open for the public, were chosen for the comparison of resistance, form factor, and propeller plane wake between model ships and full-scale ships.

The Characteristics of Longitudinal Permeability and Hydraulic Resistance in Stem of Acer mono (고로쇠나무 줄기의 통수성(通水性)과 통수저항(通水抵抗)의 특성(特性))

  • Kim, Sun-Hee;Han, Sang-Sup
    • Journal of Korean Society of Forest Science
    • /
    • v.89 no.4
    • /
    • pp.488-496
    • /
    • 2000
  • This study was carried out to investigate the characteristics of longitudinal permeability and hydraulic resistance, and to compare the longitudinal permeability ($K_E$) calculated by the Hagen-Poiseuille's law (Siau, 1971) and the longitudinal permeability (K) measured in sapwood of Acer mono stem. The volume flow rate (Q) in a vessel was $0.80{\times}10^{-4}cm^3/sec$ and the hydraulic resistance ($R_S$) to viscous flow through a vessel was, on average, $1.37{\times}10^{10}dyn{\cdot}sec{\cdot}cm^{-3}{\cdot}cm^{-2}$. The average value of volume flow rate ($Q_N$) through the cross section of sapwood was $0.32cm^3{\cdot}sec^{-1}{\cdot}cm^{-2}$, and the average resistance ($R_{SN}$) was $3.59{\times}10^6dyn{\cdot}sec{\cdot}cm^{-3}{\cdot}cm^{-2}$. The values of K decreased as the diameter of stem increases, which was attributable to variations in the number of vessel per unit area rather than in vessel diameter, and to different resistances in the conducting tissues of each part of the stem. The average value of K measured at breast height was 31% of average value of $K_E$. The $K/K_E$ ratios were 100% in 4 to 6 year-old stems and more than 90% in 7 to 27 year-old stems. The $K/K_E$ ratio decreased as the age of stems increases, and was not more than 20% in near-ground parts of stem.

  • PDF

A Preliminary Study for the Prediction of Leaking-Oil Amount from a Ruptured Tank (파손된 기름 탱크로부터의 유출양 산정을 위한 기초 연구)

  • Kim Wu-Joan;Lee Young-Yeon
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.4 no.4
    • /
    • pp.21-31
    • /
    • 2001
  • When an oil-spilling accident occurs at sea, it is of the primary importance to predict the amount of oil leakage for the swift response and decision-making. The simplest method of oil-leakage estimation is based on the hydrostatic pressure balance between oil inside the tank and seawater outside of leakage hole, that is the so-called Torricelli equilibrium relation. However, there exists discrepancy between the reality and the Torricelli relation, since the latter is obtained from the quasi-steady treatment of Bernoulli equation ignoring viscous friction. A preliminary experiment has been performed to find out the oil-leaking speed and shape. Soy-bean oil inside the inner tank was ejected into water of the outer tank through four different leakage holes to record the amount of oil leakage. Furthermore, a CFD (Computational Fluid Dynamics) method was utilized to simulate the experimental situation. The Wavier-Stokes equations were solved for two-density flow of oil and water. VOF method was employed to capture the shape of their interface. It is found that the oil-leaking speed varies due to the frictional resistance of the leakage hole passage dependent on its aspect ratio. The Torricelli factor relating the speed predicted by using the hydrostatic balance and the real leakage speed is assessed. For the present experimental setup, Torricelli factors were in the range of 35%~55% depending on the aspect ratio of leakage holes. On the other hand, CFD results predicted that Torricelli factor could be 52% regardless of the aspect ratio of the leakage holes, when the frictional resistance of leakage hole passage was neglected.

  • PDF

Experimental Study of Pressure Drop in Compressible Fluid through Porous Media (다공성재를 통과하는 압축성 유체의 압력강하에 관한 실험적 연구)

  • Seo, Min Kyo;Kim, Do Hun;Seo, Chan Woo;Lee, Seoung Youn;Jang, Seok Pil;Koo, Jaye
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.8
    • /
    • pp.759-765
    • /
    • 2013
  • This study proposes the characteristics of the pressure drop in a compressible fluid through porous media for application to a porous injector in a liquid rocket engine in order to improve the uniformity of the drop size distribution and the mixing performance of shear coaxial injectors. The fluid through the porous media is a Non-Darcy flow that shows a Nonlinear relation between the pressure drop and the velocity at high speed and high mass flow rate. The pressure drop of the Non-Darcy flow can be derived using the Forchheimer equation that includes the losses of viscous and inertia resistance. The permeability and Ergun coefficient represented as a function of the pressure drop and pore size can be applied to the porous injector, where the fluid through the porous media is compressible. A generalized correlation between the pressure drop in relation to the pore size was derived.

A 3D "In Vitro" Model to Study Hyaluronan Effect in Nasal Epithelial Cell Line Exposed to Double-Stranded RNA Poly(I:C)

  • Albano, Giusy Daniela;Bonanno, Anna;Giacomazza, Daniela;Cavalieri, Luca;Sammarco, Martina;Ingrassia, Eleonora;Gagliardo, Rosalia;Riccobono, Loredana;Moscato, Monica;Anzalone, Giulia;Montalbano, Angela Marina;Profita, Mirella
    • Biomolecules & Therapeutics
    • /
    • v.28 no.3
    • /
    • pp.272-281
    • /
    • 2020
  • Environmental agents, including viral and bacterial infectious agents, are involved in the alteration of physicochemical and biological parameters in the nasal epithelium. Hyaluronan (HA) has an important role in the regulation of tissue healing properties. High molecular weight HA (HMW-HA) shows greater anti-inflammatory responses than medium molecular weight HA (MMW-HA) and low molecular weight HA (LMW-HA). We investigated the effect of HMW-HA, MMW-HA and LMW-HA on the regulation of physicochemical and biological parameters in an "in vitro" model that might mimic viral infections of the nasal epithelium. Human nasal epithelial cell line RPMI2650 was stimulated with double-stranded RNA (dsRNA) Poly(I:C) for 5 days in air-liquid-interface (ALI) culture (3D model of airway tissue). dsRNA Poly(I:C) treatment significantly decreased transepithelial electrical resistance (TEER) in the stratified nasal epithelium of RPMI2650 and increased pH values, rheological parameters (elastic G' and viscous G''), and Muc5AC and Muc5B production in the apical wash of ALI culture of RPMI2650 in comparison to untreated cells. RPMI2650 treated with dsRNA Poly(I:C) in the presence of HMW-HA showed lower pH values, Muc5AC and Muc5B production, and rheological parameters, as well as increased TEER values in ALI culture, compared to cells treated with Poly(I:C) alone or pretreated with LMW-HA and MMW-HA. Our 3D "in vitro" model of epithelium suggests that HMW-HA might be a coadjuvant in the pharmacological treatment of viral infections, allowing for the control of some physicochemical and biological properties affecting the epithelial barrier of the nose during infection.

Model on the Contact Lens Movement from Eye-lid Blinking (순목 작용에 의한 콘택트 렌즈의 운동 모델)

  • Kim, Daesoo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.145-159
    • /
    • 2004
  • A mathematical model and its computer solution program were proposed to analyze the motion of contact lenses which are being subject to lid-blinking. The equation was derived by incorporating an acceleration induced lid's force exerting on the contact lens, the viscous damping resistance in the tear layer beneath the lens and the sliding frictional force between the lid and the contact lens surface into the formulation of differential equation describing the vibration. The model predicts the time-dependent displacement from the equilibrium postion during/after the blinking. During the blinking, as the time for the completion of one cycle of blinking decreases the off-the-equilibrium displacement of contact lens increases while the decrease of diameter in the contact cause the opposite effect. It is found that lid pressure exerting on the lens cause an insignificant lens displacement from the equilibrium position. After blinking the frequency of damped oscillation of contact lens decreases as the diameter of lens increases, due to the incresed surface while the reduced blinking time does not cause a significant frequency change. This is because that driving force for the contact lens movement posterior to blinking is the capillary-induced force not the lid force.

  • PDF

MANAGEMENT OF ORAL MUCOSITIS OWING TO CHEMICAL BURN BY INTOXICATION OF AGRICULTURAL CHEMICALS(GRAMOXON) : REPORT OF CASES (농약(Gramoxon)중독에 의한 화상으로 발생된 구강점막염 치험)

  • Yoo, Jae-Ha;Kang, Sang-Hoon;Kim, Hyun-Sil;Baek, Sang-Hum;You, Tae-Min;Lee, Ji-Woong;Chung, Won-Gyun;Kim, Jong-Bae
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.2
    • /
    • pp.123-127
    • /
    • 2003
  • Chemical burns onto oral mucosa which are infrequent, may result from contact with a wide variety of chemical agents. The degree of injury depends on the chemical, its concentration, duration of contact, and the natural penetrability and resistance of the tissues involved. Chemicals do not usually "burn" in that they do not cause destruction by hyperthermic activity. Rather, they damage tissue by causing coagulation of protein by one of several processes, reduction, oxidation, desiccation, corrosion, or vesication. Paraquat(Gramoxon) is the most frequently agricultural chemicals that induce the severe toxic reactions onto the organs of human body in Korea. The toxic reaction are composed of pulmonary edema and fibrosis, formation of hyaline membrane, inflammatory reaction and bleeding tendency, owing to the cell damage by the production of superoxide radicals. The contents of essential treatment in paraquat intoxication are commonly airway and breathing maintenance, gastric lavage, much hydration and diuresis, hemoperfusion and medications for the removal of the chemicals and the prevention of various complications. The sedative oral dressings, such as, orabase ointment application, warm saline gargling, lidocaine viscous gargling and oral gargling by the mixed solutions(tetracycline, prednisolone and 10% dextrose water) are important for the improvement of chemical oral mucositis and the comfortable feeding of diet. The authors managed properly two cases of oral chemical mucositis that were occurred by the incorrect use of agricultural chemicals(paraquat) and report the cases with the review of literatures about care of the chemical intoxication and oral mucositis.

Underfill Flow Characteristics for Flip-Chip Packaging (플립칩 패키징 언더필 유동특성에 관한 연구)

  • Song, Yong;Lee, Sun-Beung;Jeon, Sung-Ho;Yim, Byung-Seung;Chung, Hyun-Seok;Kim, Jong-Min
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.16 no.3
    • /
    • pp.39-43
    • /
    • 2009
  • In this paper, the flow characteristics of underfill material driven by capillary action between flip-chip and substrate were investigated. Also, the effects of viscosity level and dispensing point of underfill on flow characteristics were investigated. Flip chip package size was $5mm{\times}5mm{\times}0.65^tmm$, the diameter of solder bump was 100 ${\mu}m$, and the pitch was 150 ${\mu}m$. It was full grid area-array type with 1024 I/Os. The glass substrate was used and the gap between the chip and substrate was 50 ${\mu}m$. For the experimental study, three different underfills with different viscous properties($2000{\sim}3700$ cps), and two different types of dispensing methods(center dot and edge dot) were used. The flow characteristics and filling time of underfill were investigated by using CCD camera. The results show that the edge flow was faster than center flow due to the edge effect, which was caused by the resistance of solder bumps. In case of edge dot dispensing type, the filling time was faster due to the large edge effect, compared to center dot dispensing type. Also, it was found that the underfill flow was faster and the filling time decreased as the viscosity level of underfill was decreased.

  • PDF