• 제목/요약/키워드: viscometer

검색결과 247건 처리시간 0.026초

Measurements of Blood Viscosity Using a Pressure-Scanning Slit Viscometer

  • Sehyun Shin;Lee, Sung-Woo;Ku, Yun-Hee
    • Journal of Mechanical Science and Technology
    • /
    • 제18권6호
    • /
    • pp.1036-1041
    • /
    • 2004
  • A newly designed pressure-scanning slit viscometer is developed to combine an optical device without refraction while measuring blood viscosity over a range of shear rates. The capillary tube in a previously designed capillary viscometer was replaced with a transparent slit, which is affordable to mount optical measurement of flowing blood cells. Using a pressure transducer, we measured the change of pressure in a collecting chamber with respect to the time, p(t), from which the viscosity and shear rate were mathematically calculated. For water, standard oil and whole blood, excellent agreement was found between the results from the pressure-scanning slit viscometer and those from a commercially available rotating viscometer. This new viscometer overcomes the drawbacks of the previously designed capillary viscometer in the measuring whole blood viscosity. First, the pressure-scanning slit viscometer can combine an optical instrument such as a microscope. Second, this design is low cost and simple (i.e., ease of operation, no moving parts, and disposable).

Blood Viscosity Measurements Using a Pressure-Scanning Capillary Viscometer

  • Sehyun Shin;Keum, Do-Young;Ku, Yun-Hee
    • Journal of Mechanical Science and Technology
    • /
    • 제16권12호
    • /
    • pp.1719-1724
    • /
    • 2002
  • A previously designed capillary viscometer with measuring differential pressure was modified to measure the viscosity of non-Newtonian fluids including unadulterated blood continuously over numerous shear rates in a single measurement. Because of unavoidable experimental noise and a limited number of data, the previous capillary viscometer experienced an inaccuracy and could not directly determine a viscosity without an iterative calculation. However, in the present measurement there are numerous data available near the point of interest so that the numeric value of the derivative, d(In Q)/d(In Q$\sub$w/), is no longer sensitive to the method of differentiation. In addition, relatively low and wide shear rate viscosity measurements were possible because of the present precision pressure-scanning method with respect to time. For aqueous polymer solutions, excellent agreement was found between the results from the pressure-scanning capillary viscometer and those from a commercially available rotating viscometer. In addition, the pressure-scanning capillary viscometer measured the viscosity of unadulterated whole blood without adding any anticoagulants.

숙성기간에 따른 재래 고추장의 유동성 변화 (Flow Properties of Traditional Kochujang : Effect of Fermentation Time)

  • 유병승;최원석;류영기
    • 한국식품영양과학회지
    • /
    • 제28권3호
    • /
    • pp.554-558
    • /
    • 1999
  • Flow properties of traditional kochujang at various fermentation times(0~12 weeks) were determined with rotational cylindrical(RC) and serrated plate plate(PP) viscometer. Magnitudes of consistency index(K) of power law model and Cassson parameters(yield stress and viscosity) measured by PP viscometer were higher than those using RC viscometer. All kochujang samples during fermentation were much shear thinning with values of flow behavior index(n) as low as 0.2~0.34. K value and Casson yield stress measured by PP viscometer had good correlations(r=0.94; r=0.91) with fermentation time. No significant changes in flow model parameters measured by RC viscometer were observed for kochu jang during fermentation. Magnitudes of flow model parameters measured by PP viscometer more closely correlated with fermantation times of kochujang than did RC viscometer.

  • PDF

Continuous Viscosity Measurement of Non-Newtonian Fluids over a Range of Shear Rates Using a Mass-Detecting Capillary Viscometer

  • Sehyun Shin;Keum, Do-Young
    • Journal of Mechanical Science and Technology
    • /
    • 제16권2호
    • /
    • pp.255-261
    • /
    • 2002
  • A newly designed mass-detecting capillary viscometer uses a novel concept to continuously measure non-Newtonian fluids viscosity over a range of shear rates. A single measurement of liquid-mass variation with time replaces the now rate and pressure drop measurements that are usually required by capillary tube viscometers. Using a load cell and a capillary, we measured change in the mass flow rate through a capillary tube with respect to the time, m(t), from which viscosity and shear rate were mathematically calculated. For aqueous polymer solutions, excellent agreement was found between the results from the mass-detecting capillary viscometer and those from a commercially available rotating viscometer. This new method overcomes the drawbacks of conventional capillary viscometers meassuring non-Newtonian fluid viscosity. First, the mass-detecting capillary viscometer can accurately and consistently measure non -Newtonian viscosity over a wide range of shear rate extending as low as 1 s$\^$-1/. Second, this design provides simplicity (i. e., ease of operation, no moving parts), and low cost.

Extrusion Capillary Viscometer를 이용한 반고체 식품의 점도 측정 방법 (Measurement of the Viscosity of Semi-Soild Foods by Extrusion Capillary Viscometer)

  • 김길환;이부용;김동만
    • 한국식품영양과학회지
    • /
    • 제20권5호
    • /
    • pp.509-512
    • /
    • 1991
  • Rheological property and apparent viscosity(η)of several semi-solid foods were measured with extrusion capillary viscometer. Apparent viscosities of several semi-solid foods ranged from 0.2714 Pa.s to 2.6453 Pa.s Rheological property of spread type semi-solid foods was pseudoplastic (with yield value). Especially, as the moisture content and temperature of Chungkook-jang spread increased, apparent viscosity decreased. On the contrary, as the added soybean oil content of Chungkook-jang spread increased, apparent viscosity also increased.

  • PDF

낙구식 점도계를 이용한 점탄성유체의 유동에 관한 연구 (A Study on the Flow Behavior of the Viscoelastic Fluids in the Falling Ball Viscometer)

  • 전찬열
    • 한국안전학회지
    • /
    • 제3권1호
    • /
    • pp.15-19
    • /
    • 1988
  • The falling ball viscometer has been widely used for measuring the viscosity of the Newtonian fluids because of its simple theory and low cost. The use of the falling ball viscometer for measuring the non-Newtonian viscosity has been of interest to rheologists for some years. The analysis of the experimental results in a falling ball viscometer rest on Stokes law which yields the terminal velocity for a sphere moving through an infinite medium of fluids. An attempt to use the falling ball viscometer to measure the non-Newtonian viscosity in the intermediate shear rate ranEe was sucessfully accomplished by combining the direct experimental obserbations with a simple analytical model for the average shear-stress and shear rate at, the surface of a sphere. In the experiments with highly viscoelastic polyacrylamide solutions the terminal velocity was observed to be dependent on the time interval between the dropping of successive balls. The time-dependent phenomenon was used to determine characteristic diffusion times of the concentrated solutions of polyacrylamide.

  • PDF

낙구식 점도계를 이용한 점탄성 유체의 특성시간에 관한 실험적 연구 (An experimental study on the characteristic times of viscoelastic fluids by falling ball viscometer)

  • 전찬열;유상신
    • 대한기계학회논문집
    • /
    • 제14권1호
    • /
    • pp.241-250
    • /
    • 1990
  • 본 연구에서는 낙구식 점도계를 이용하여 낮은 농도의 용액을 실험할 때 종말 속도측정의 어려움을 해결하기 위하여 레이저와 특수 타이머를 설치하였으며 정확한 특성시간을 결정하기 위하여 실린더 내부의 시험유체를 교란시키지 않고, 떨어뜨린 구 를 회수하는 장치를 제작하였다. 또한 주로 rheogoniometer에 의존하던 영 전단률 점성계수를 측정하기 위하여 속이 빈 알루미늄 구(hollow aluminium ball)의 밀도를 시험 유체와 거의 같은 정도까지 변화시켜가며 종말 속도를 측정하였으며 점탄성 유체 로써 Separan AP-273의 낮은 농도인 300에서 2000wppm까지의 저농도 용액에 대한 특성 시간을 여러모델에 의하여 실험적으로 결정하고 저농도 폴리머 용액에서 퇴화로 인한 점탄성유체의 특성 변화를 분석하였다.

ER유체의 겉보기 점도특성 평가에 관한 연구 (Evaluation of Apparent Viscosity Properties for Electro-Rheological Fluid)

  • 안영공;;양보석
    • Tribology and Lubricants
    • /
    • 제14권2호
    • /
    • pp.42-48
    • /
    • 1998
  • Electro-Rheological (ER) fluid is a class of functional fluid whose apparent viscosity can be varied by the applied electric field strength. The ER fluid is classified into two types; one is a dispersive fluid and the other is a homogeneous. Dispersive ER fluid is a colloidal suspension of fine semiconducting particles in a dielectric liquid and liquid crystal (LC) is classed as homogeneous type ER fluid. LC has been originally developed for some electronic display devices. Various mechanical components applying ER fluid have been developed, and the their performance typically depends on the characteristics of ER fluid which have generally been evaluated by a rotational viscometer. However, the ER fluid introduced into various mechanical components undergoes not only simple shear flow but press flow or oscillating flow. For the evaluation of ER fluid, the authors developed an reciprocating type viscometer. The amplitude is controlled on 5 mm at the frequency from 50 to 1000 Hz. In the present paper, the performance of several types of ER fluid is evaluated by the reciprocating type viscometer and compared with those evaluated by a rotational viscometer.

A Novel Viscosity Measurement Technique Using a Falling Ball Viscometer with a High-speed Camera

  • Jo, Won-Jin;Pak, Bock-Choon;Lee, Dong-Hwan
    • KSTLE International Journal
    • /
    • 제8권1호
    • /
    • pp.16-20
    • /
    • 2007
  • This study introduces a new approach to a falling ball viscometer by using a high speed motion camera to measure the viscosity of both Newtonian and non-Newtonian fluids from the velocity-time data. This method involves capturing continuous photographs of the entire falling motion of the ball as the ball accelerates from the rest to the terminal velocity state. The velocity of a falling ball was determined from the distance traversed by the ball by examining video tape frame by frame using the marked graduations on the surface of the cylinder. Each frame was pre-set at 0.01. Glycerin 74% was used for Newtonian solution, while aqueous solutions of Polyacrylamide and Carboxymethyl Cellulose were for non-Newtonian solutions. The experimental viscosity data were in good agreements with the results obtained from a rotating Brookfield viscometer.

비정상유동장에서 모세관점도계의 점도측정 (Viscosity Measurement in the Capillary Tube Viscometer under Unsteady Flow)

  • 박흥준;유상신;서상호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.825-828
    • /
    • 2000
  • The objective of the present study is to develop a new device that the viscous characteristics of fluids are determined by applying the unsteady flow concept to the traditional capillary tube viscometer. The capillary tube viscometer consists of a small cylindrical reservoir, capillary tube, a load celt system oat measures the mass flow rate, interfacers, and computer. Due to the small size of the reservoir the height of liquid in the reservoir decreases as soon as the liquid in the reservoir drains out through the capillary and the mass flow rate in the capillary decreases as the hydrostatic pressure in the reservoir decreases resulting in a decrease of the shear rate in the capillary tube. The instantaneous shear rate and. driving force in the capillary tube are determined by measuring the mass flow rate through the capillary, and the fluid viscosity is determined from the measured flow rate and the driving force.

  • PDF