• Title/Summary/Keyword: vierendeel truss

Search Result 12, Processing Time 0.015 seconds

Analysis on the Building System Integration Methods of the Salk Institute for Biological Studies (솔크 생물학 연구소에 적용된 건물시스템 통합기법 분석에 관한 연구)

  • Choi, Joon Sung
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.7
    • /
    • pp.59-68
    • /
    • 2018
  • Salk Institute for Biological studies is widely considered as architectural masterpiece of Louis Kahn's. Its iconic plaza with symmetrical concrete structures, overlooking the Pacific ocean in La Jolla, has been acclaimed as a facade to the sky. Little has been written on Kahn's achievements in the building system integration in order to bridge the gap between technology and design. This paper explores the technical issues, the design intents, and the major building systems to identify the Kahn's integration methods between building systems. The project is analysed into four major systems; structure, mechanical, envelope, and interior system. The integration methods of building systems are investigated in physical, visual, and functional aspects. The most distinguished cases of building system integration are the introduction of the interstitial floors between the laboratories and the creation of the smooth and warm materiality of exposed concrete walls. Kahn proposed open floor plans for the laboratories which are capable of easily adapting to changing needs. He also introduced the interstitial floors which are framed of the vierendeel truss systems and deliberately overlapped the structure systems with the mechanical systems such as ducts, water pipes, and electric conduits. The exposed concrete walls mixed with pozzolan ashes look very much like granite or limestone as the result of the physical and visual integration between structure, envelope, and interior systems.

Evaluation of Shear Performance of Rectangular NRC Beam (직사각형 NRC 보의 전단성능 평가)

  • Lee, Ha-Seung;Lee, Sang-Yun;Kim, Seung-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.1
    • /
    • pp.81-88
    • /
    • 2022
  • In the NRC (New paradigm Reinforced Concrete) beam, steel forms, main angles used as main reinforcements, and shear angles used as basic shear reinforcements are welded and assembled in the form of vierendeel truss structures in a steel factory. After the NRC truss frame is installed at the site, additional main reinforcement and shear reinforcement are distributed. In this study, the shear performance evaluation of the NRC beam was conducted through shear tests in accordance with the type of shear reinforcement of the NRC beam (shear angle, inclined shear reinforcing bar, and U-type cover bar). As a result of the test, the initial stiffness was similar before the initial cracking of each specimen, and all specimens were shear fractured.The shear reinforcements of the specimens exhibited a yielding behavior at the time of the maximum sheat force, and the shear strengths of the specimens increased as the amount of reinforcement of the shear reinforcement increased. These results show that NRC shear reinforcements exhibit shear performance corresponding to their shear strength contribution. As a result of calculating the nominal shear strengths according to KDS 14 20 22, the experimental shear strengths of the NRC beam specimens with shear reinforcement was 37~146% larger than the nominal shear strengths, so It was evaluated as a safety side.