• Title/Summary/Keyword: vibration type

Search Result 2,510, Processing Time 0.031 seconds

Identification of vibration source and vibration improvement design of forklift truck with trans-axle type power train (Trans-axle형태의 구동계를 갖는 지게차의 진동원 파악 및 저감설계)

  • 박인환;김성재;김낙인
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.855-860
    • /
    • 2001
  • In this study, the improvement work to reduce the steering wheel vibration of a forklift truck is performed. The forklift truck newly developed possesses a trans-axle type power train to achieve a compact and low-price design. The forklift truck is directly subjected to a high-level engine vibration through hard mounted trans-axle housing. The engine vibration shakes the whole system of the forklift truck, and then a high level local vibration of steering wheel could not be avoided. As the results, the vibration source and path mechanisms are experimentally identified and then an improvement design is proposed to minimize the steering wheel vibration.

  • PDF

A Study on Measurement and Assessment of Local Vibration by Walking-type Cultivator (보행형 관리기의 국소진동 측정과 평가에 관한 연구)

  • Noh, Kyoung-Kyu;Park, Peom
    • Journal of the Korea Safety Management & Science
    • /
    • v.11 no.1
    • /
    • pp.67-73
    • /
    • 2009
  • The goal of this study was to assess the level of vibration in an walking-type cultivator, and to provide a basic information to manage the vibration exposure for farmers. The latent periods of vibration-induced white finger (VWF) were assessed through analyzing the vibration levels and frequency characteristics. Also, vibration acceleration levels based on the daily vibration exposure duration was suggested. The latent periods of vibration-induced white finger were assessed by ISO 5349 method. The latent periods were 4.5 and 10.1 years at 10% and 50% of farmer group, respectively. Also, under ACGIH (American Conference of Governmental Industrial Hygienists) standard, daily vibration exposure duration at 6.7 m/s2 of vibration acceleration has to be less than 4 hours. Therefore, education that maximum working hours should be less than 4 continuous hours is necessary for the operators of walking-type cultivators.

Vibration of rotating machinery due to proximity (Proximity에서 유도된 회전기계의 이상 진동)

  • 구재량;황재현;김두영;윤완노;김연환
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.532-535
    • /
    • 2003
  • Vibration of rotating machinery is a factor that is something to do with abnormal machinery. Former days, Perception of vibration at rotating machinery had used Shaft rider type. Shaft rider type was adhered to surface of shaft and detected vibration of rotating machinery. Recently, Perception of vibration at rotating machinery uses to non-contact sensor. Working principle of non-contact sensor is used of eddy current. Vibration at rotating machinery appears to deviation of eddy current. In this paper, We investigate abnormal vibration due to non-contact sensor.

  • PDF

Experimental Behavior Analysis of Double Isolated Anti-Vibration System (2중방진 시스템의 실험적 거동해석)

  • 이홍기;이신언
    • Journal of KSNVE
    • /
    • v.2 no.4
    • /
    • pp.281-292
    • /
    • 1992
  • Two types of vibration problems are encountered in industrial field: active isolation and passive isolation. In a passive type of vibration isolation, a foundation of a delicated machinery such as TEM, SEM, inspection- probe test, photolithograph, etc. is designed to have a vibration amplitude lower than an acceptable limit. In an active type, the isolation is focused on the vibration reduction caused by the machine itself(pump, motor, press, compressor, etc.). The foundation for such a machine should be so designed as to reduce the transmitted vibration below the permissible level prescribed. At any case, a transmissibility and stability must to be considered. Since an active isolation type is aimed for a vibration source, it is useful to isolate the transmitted vibrations energy from a major vibration source at the specific location. In this paper, a designed methodology of double anti-vibration system has been examined in order to have low transmissibility and reliable stability. Also experiment of scale model behavior has been conducted. Finally, the experiment output of the transfer function is compared to the analytical data.

  • PDF

The Rotor Shape Design of IPM Type BLDC Motor for Minimization of Vibration (IPM type BLDC 전동기의 진동저감을 위한 회전자 형상설계)

  • Reu, Jin-Wook;Kang, Gyu-Hong;Hur, Jin
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.895_896
    • /
    • 2009
  • this paper presents a rotor shape optimization of interior type permanent magnet (IPM) motor for vibration minimization. the vibration of permanent magnet motor is generated by cogging torque, radial force and commutation torque ripple which are electromagnetic source of vibration. In order to minimize the vibration, the optimal notches are put on the rotor pole face and the arc type pole face is applied. The variations of cogging torque and radial force of each model vibration frequency are computation by finite element method (FEM) and the validity of the analysis and rotor shape design is confirmed by vibration experiments.

  • PDF

Vibration-based Structural Health Monitoring of Caisson-type Breakwaters Damaged on Rubble Mound (사석마운드가 손상된 케이슨식 방파제의 진동기반 구조건전성 모니터링)

  • Lee, So-Young;Kim, Jeong-Tae;Kim, Heon-Tae
    • Journal of Ocean Engineering and Technology
    • /
    • v.24 no.1
    • /
    • pp.90-98
    • /
    • 2010
  • In this paper, vibration-based structural health monitoring methods that are suitable for caisson-type structures are examined by an experimental evaluation. To achieve the objective, four approaches are implemented. First, vibration-based structural health monitoring methods are selected to monitor the structural condition of caisson-type breakwaters. Second, a lab-scaled caisson structure is constructed to verify the selected monitoring methods. Third, the vibration characteristics are numerically analyzed using an FE model due to the change in the rubble mound condition. Finally, experimental vibration tests of the lab-scaled caisson structure are performed to monitor the vibration responses due to changes in rubble mound conditions and the performances of the selected methods are examined from the monitoring results.

Nonlinearity of Biodynamic Response to Shock-Type Vertical Whole-Body Vibration (쇼크타입 수직방향 전신진동에 대한 생체동역학적 반응의 비선형성)

  • Ahn Se-Jin;Griffin Michael J.;Yoo Wan-Suk;Jeong, Weui-Bong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.2 s.257
    • /
    • pp.145-151
    • /
    • 2007
  • Impulsive excitation on vehicle produces shock-type vibration on the seat, which has major frequencies and damping ratios dependent on the characteristics of the suspension, the tire, the seat cushion and so on. The response of single degree of freedom model to a half-sine force input was considered as simple shock-type vibration signal. Quasi-apparent-mass for fifteen subjects was measured with the shock-type vibration generated on a rigid seat mounted on the simulator, so its nonlinearity was apparently found over 6.3 Hz according to the difference of magnitude of the shock.

Preload Effects on the Metal Temperature and Shaft Vibration in a Guide Bearing for Hydraulic Pump-Turbines (펌프-터빈에서 안내 베어링의 예압이 온도 및 축 진동에 미치는 영향)

  • 하현천;양승헌;최성필;김호종
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1997.10a
    • /
    • pp.123-128
    • /
    • 1997
  • In-situ bearing metal temperature and shaft vibration are measured for an unload type and a preload type, m=0.87, of vertical guide bearing for hydraulic pump-turbines. Guide bearing is a tiltingpad type journal bearing consisting of eight pads whose diameter is 1,450 mm. Rotational speed is 450 rpm. Both the bearing metal temperature and the shaft vibration are very high in the unload type but are slight in the preload type, comparatively. The bearing metal temperature is decreased due to the increase of cooling effect by the increase of preload and the shaft vibration is decreased due to the increase of bearing stiffness. It is concluded that the preload effect of a guide bearing for hydraulic pump-turbines has a large influence on the bearing metal temperature and the shaft vibration.

  • PDF

A Study of Improvement on the Torsional Vibration of Input Shaft and Structural Vibration of Vehicle Using Tunable Dual Stiffness Type Clutch in Auto-transmission (자동변속기에서 2중 동조 강성형 클러치를 이용한 입력축의 비틀림 진동 및 차체 진동의 개선에 관한 연구)

  • Jung, Byung-Hwan;Hwang, Seon-Yang;Kang, Koo-Tae
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.10
    • /
    • pp.883-890
    • /
    • 2010
  • According to torsional vibration characteristic of a tunable dual stiffness type clutch(TDSTC) in auto-transmission, the input shaft system have occurred breakdown for the duration cycle and over-vibration happened on vehicle at specific condition. This paper introduces the improvement of the torsional vibration of input shaft and the vehicle vibration by tuning of the TDSTC.

Finite Element Analysis of Step-down Piezoelectric Transformer with Various Shape (형태의 변화에 따른 강압용 압전변압기의 유한요소해석)

  • Chong, Hyon-Ho;Park, Tae-Gone;Kwon, Oh-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.697-700
    • /
    • 2003
  • This paper presents design and analysis of step-down piezoelectric transformer for application to AC-adapters. These transformers are consist of rectangular type and disk type multilayered piezoelectric ceramic plate. This piezoelectric transformer operated in third thickness resonance vibration mode. Finite element methode(FEM) was used for analysing transformer. Vibration mode and electric field of piezoelectric transformer were simulated at resonance frequency. As results, rectangular type transformer's output voltage was higher than the disk type. But disk type transformer's current was lagger than rectangular type. These results are assumed that disk type transformer's mixed vibration mode influence transformer's output characteristics. From these results, we expect that disk type piezoelectric transformer is more adoptable than rectangular plate type piezoelectric transformer for AC adapters.

  • PDF