• 제목/요약/키워드: vibration performance

Search Result 3,969, Processing Time 0.029 seconds

Performance Enhancement of Pneumatic Vibration Isolator in Low Frequency by Time Delay Control (시간지연 제어기법을 이용한 공압 제진대의 저주파 영역에서의 진동 절연 성능 향상)

  • Oh, Ki-Yong;Shin, Yun-Ho;Lee, Jeung-Hoon;Kim, Kwang-Joon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.11 s.116
    • /
    • pp.1100-1107
    • /
    • 2006
  • As environmental vibration requirements on precision equipment become more stringent, use of pneumatic isolators has become more popular and their performance is subsequently required to be further improved. Performance of passive pneumatic isolators is related to various design parameters in a complicated manner and, hence, is very limited especially in low frequency range by chamber volume. In this study, transmissibility behavior of the pneumatic isolators depending on frequency and dynamic amplitude are presented. Then, an active control technique, time delay control, which is adequate for a low frequency nonlinear system, is applied. A procedure of applying the time delay control law to a pneumatic isolator is presented and it's effectiveness in the transmissibility performance is shown. Comparison between passive and active pneumatic isolators is made based on simulation.

Evaluation of high performance isolation spring mount by attached masses (부가질량 효과에 따른 고효율 방진마운트의 진동저감 성능평가)

  • Ho, Kyoung-Chan;Lee, Byoung-Chul;Lee, Yong-Hyun;Lee, Young-Je;Kim, Min-Bae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1247-1252
    • /
    • 2007
  • The machine equipment of the building inside occurs the vibration. In order to reduce this vibration spring, rubber pad is used. But efficiency of this classical mount is restricted at specific frequency. Also maximum efficiency design is complicated. This paper proposes and examines a attached mass isolation system that is used to reduce transmitted vibrations from machines onto their floor support. With attached mass the low frequency performance is improved overall. The performance is showed in 2 degree of freedom model test. And the proposed isolator has been validated by dynamic test and good agreement between theoretical and experimental results has been obtained.

  • PDF

Qualitative Noise Characteristics of Rotating Polygonal Disk Applied to Digital Printer Systems (디지털 프린터에 적용되는 회전 다각형 디스크의 소음특성)

  • Jo, Jun-Hyeon;Kim, Hyeong-Chae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1425-1429
    • /
    • 2007
  • Consumer's product selection measures are being shifted from the units' operational performance to overall performance. Low noise, low vibration, and low power consumption rate, etc. which used to be additional quality indices, now become vital performance factors. Especially, noise and vibration characteristics are being considered as equivalent to/or even more critical than operational performance in certain products such as office machines and home entertainment systems, which share the same space with human being's daily life. Therefore, noise reduction and sound quality improvement technology becomes an inevitable design issue for those applications. Qualitative noise characteristics of rotating polygonal disk applied to digital printer systems are presented. Overall sound pressure level change and tonal noise variation with respect to the geometrical properties of polygonal disk, operational speed, and others are briefly discussed based on experimental results.

  • PDF

Robust Vibration Control for a Building with Parameter Uncertainty (파라미터 불확실성을 고려한 건물의 견실 진동 제어)

  • 최재원;김신종;이만형
    • Journal of KSNVE
    • /
    • v.10 no.4
    • /
    • pp.575-583
    • /
    • 2000
  • In this paper, we design a vibration control system that includes a 3-D.O.F. mass-spring-damper structure for the analytical model of a building that is excited at the base of this structure by an external dynamic force, and one Active Mass Damper(AMD) on the top of this structure to generate control forces fro attenuation of the structural response. Two robust controllers based on $\mu$-synthesis and H$\infty$ optimal control are designed for the structural system to show that the performance of a control system can be degraded by some parameter uncertainties such as mass, stiffness coefficients, and/or damping coefficients. The performance of the two controllers are compared in terms of nominal performance, robust stability and robust performance by simulations.

  • PDF

Qualitative Noise Characteristics of Rotating Polygonal Disk Applied to Digital Printer Systems (디지털 프린터에 적용되는 회전 다각형 디스크의 소음특성)

  • Jo, Jun-Hyeon;Kim, Hyeong-Chae
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.6
    • /
    • pp.606-611
    • /
    • 2008
  • Consumer's product selection measures are being shifted from the units' operational performance to overall performance. Low noise, low vibration, and low power consumption rate, etc. which used to be additional quality indices, now become vital performance factors. Especially, noise and vibration characteristics are being considered as equivalent to/or even more critical than operational performance in certain products such as office machines and home entertainment systems, which share the same space with human being's daily life. Therefore, noise reduction and sound quality improvement technology becomes an inevitable design issue for those applications. Qualitative noise characteristics of rotating polygonal disk applied to digital printer systems are presented. Overall sound pressure level change and tonal noise variation with respect to the geometrical properties of polygonal disk, operational speed, and others are briefly discussed based on experimental results.

Performance Enhancement of Pneumatic Vibration Isolator in Low Frequency by Time Delay Control (시간지연 제어기법을 이용한 공압 제진대의 저주파 영역에서의 진동 절연 성능 향상)

  • Oh, Ki-Yong;Shin, Yun-Ho;Lee, Jeung-Hoon;Kim, Kwang-Joon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.837-843
    • /
    • 2006
  • As environmental vibration requirements on precision equipment become more stringent, use of pneumatic isolators has become more popular and their performance is subsequently required to be further improved. Performance of passive pneumatic isolators is related to various design parameters in a complicated manner and, hence, is very limited especially in low frequency range by chamber volume. In this study, transmissibility behavior of the pneumatic isolators depending on frequency and dynamic amplitude are presented. Then, an active control technique, time delay control, which is adequate for a low frequency nonlinear system, is applied. A procedure of applying the time delay control law to a pneumatic isolator is presented and it's effectiveness in the transmissibility performance is shown. Comparison between passive and active pneumatic isolators is made based on simulation.

  • PDF

Vibration Performance test and static load test of body flat freight car (평판화차의 차체 정하중시험 및 진동성능시험)

  • Hong Jai-Sung;Ham Young-Sam;Kim Gil-Dong;Han Suk-Youn;Cha Ji-Bum
    • Proceedings of the KSR Conference
    • /
    • 2003.05a
    • /
    • pp.700-705
    • /
    • 2003
  • The object of this study is to ensure the stability of flat freight cars using vibration performance test and static load test of body structures. We examined the flat car though static load test and dynamic characteristics analysis related traveling stability and vibration performance. In the results of static load test of body structures for flat car, all structures satisfied allowable stress of materials. The vibration performance test was satisfied with allowable standards. Although flat car exceed speed a little at some speed interval, it was estimated that the cause was not cars but rail.

  • PDF

A study about an old age car performance characteristic (노후차량 성능 특성에 관한 연구)

  • Hong Yong-Ki;Kwon Sung-Tae
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.332-337
    • /
    • 2005
  • In order to investigate performance changes, the acceleration, vibration, and braking performance tests were carried out on the electric multiple units (EMUs) with over 20 years operation. According to the testing results, in vibration and braking performance, the similar performance results were obtained as compared with newly manufactured EMUs. However, in terms of acceleration performance, below reference value (3.0 km/h/s) has been obtained. This is mainly due to performance deterioration including traction motor. The precision diagnosis evaluation of deteriorated EMUs will be provided through the overall evaluation of corrosion testing and structural performance of car body.

  • PDF

A study on response analysis of 6-DOF pneumatic vibration isolation table loaded by transient movements of carriage on it (상판 위 질량의 순간적인 움직임에 의해 가진되는 6-자유도 공압제진대의 진동 응답에 대한 연구)

  • Sun, Jong-Oh;Shin, Yun-Ho;Kim, Kwang-Joon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.97-102
    • /
    • 2007
  • As environmental vibration requirements on precision equipments get more stringent, use of pneumatic vibration isolators becomes more crucial and, hence, their dynamic performance needs to be further improved. Dynamic behavior of those pneumatic vibration isolation tables is very important to both manufacturer and customer as performance specifications. Together with conventional transmissibility, transient response characteristics are another critical performance index especially when movements of components, e.g., x-y tables, of the precision equipments are very dynamic. In this paper, analysis on transient response of a pneumatic vibration isolation table loaded by a mass moving on it is presented. This is a conventional dynamics problem on a rigid body with 6 degree of freedom and a mass with another degree of freedom. How to obtain transient responses of the isolation table is described when the movements of the mass are prescribed relative to the table.

  • PDF

Vibration Performance Monitoring of a 1kW Small Wind Turbine Generator (1kW 소형 풍력발전기의 진동 성능 모니터링)

  • Kim, Seok-Hyun;Nam, Yoon-Soo;Yoo, Neung-Soo;Park, Mu-Yeol;Kim, Tae-Hyoung;Park, Hae-Gyun
    • Journal of Industrial Technology
    • /
    • v.26 no.A
    • /
    • pp.75-80
    • /
    • 2006
  • A vibration monitoring is performed on a 1kW class stand alone wind turbine(W/T). When a W/T model is developed, general performance under various wind condition should be verified to introduce the product in the market. Especially, vibration characteristics within operating speed range are very important in the aspect of structural stability as well as generator's electrical efficiency. This paper examines the vibration performance of a home made 1kW W/T. Various data of the W/T model are acquired in real time using a remote vibration monitoring system installed in Daekwanryung test site. Vibration stability of the W/T structure is diagnosed based upon the data and the result is used to estimate the applicability of the W/T model.

  • PDF