• Title/Summary/Keyword: vibration acceleration magnitude

Search Result 75, Processing Time 0.022 seconds

Measurement of Absolute Magnitude and Position of HDD Unbalance based on Mobility (모빌리티 측정을 통한 하드디스크의 Unbalance 검출 및 보정방법)

  • Choi, Hyun;Kim, In-Woong;Lee, Jae-Won;Jeong, Yong-Koo;Choi, Jung-Hun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.358-362
    • /
    • 2002
  • The HDD unbalance, with higher rotational speed, is directly influenced by the mechanical assembly allowance between clamping disk and platter disk. The low frequency structural vibration induced by the unbalance force finally gives rise to the structure borne noise of the personal computer. To meet the noise and vibration requirements, the absolute unbalance mass of HDD needs to be measured and adjusted in the disk assembling stage. This study introduces the measurement methods of the absolute magnitude and position of the unbalance mass of HDD based on the mobility and acceleration orbit. The absolute unbalance mass can be obtained by the acceleration responses and the mobility of the mechanical part, while the position of the unbalance mass ran be obtained by the rotation acceleration orbit.

  • PDF

Vibration Damping Characteristics of the Powered Hand Tools on Hand-Arm System (손-팔 시스템에 전달되는 전동수공구의 진동감쇠 특성)

  • 장규표;김길주;이동춘
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.22 no.52
    • /
    • pp.43-52
    • /
    • 1999
  • In this study, the vibration damping characteristics of the powered hand tools transmitted in hand-arm system were examined and compared. The types of powered tools for the experiment are general typed drill, impact drill, grinder, and wire brush. To analyze the characteristics of vibration damping, the magnitude of acceleration of vibration on X, Y, and Z direction at tool, hand, wrist, and the joint between forearm and upper arm were measured respectively. The results indicated that impact drill generated the highest value of acceleration of vibration among the four types of tools used in the experiments. The highest value of the amount of acceleration of vibration was found in the direction of Y. And the amount of acceleration of vibration was significantly affected by the type of tool, type of work, and pushing forces. As become the more distant from the tool, the smaller the amount of acceleration of vibration. Also, the bigger the pushing force at the tool, the higher the acceleration of vibration.

  • PDF

Human Comfort Criterium for Horizontal Vibration of High-Rise Buildings (초고층 건축물의 수평진동 사용성 평가기준)

  • Cho, Kang-Pyo;Hong, Sung-Il;Jeong, Seung-Hwan;Jo, Su-Yeon
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.105-108
    • /
    • 2006
  • should be in This paper presents review on human comfort criteria in major codes and standards for tall buildings. In general, human comfort criteria of tall buildings have been used by magnitude of wind-induced acceleration response. Two different indexes in determination of the magnitude have been used: the peak value which occurs during a period of time and the rms value averaged over this same period. These distinctive acceleration indexes are discussed in detail and each criterium was reviewed and compared. The distinctions arisen because of the different wave forms, or acceleration signatures were addressed. It is described that which index of acceleration should be adopted in establishment of Korean human comfort criteria. In addition, some arguments from a technical standpoint that favor the use of each index are presented.

  • PDF

Performance Evaluation of Vertical Vibration of Precast Concrete Slabs (프리캐스트 콘크리트 바닥판의 수직진동 허용치 평가)

  • Heo, Seok-Jae;Lee, Sang-Hyun;Cho, Seung-Ho;Chung, Lan;Kim, Sung-Bae;Park, Sung-Soon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.662-667
    • /
    • 2009
  • In this study, the serviceability of Waffle shaped(WAS) and Double-Tee(DT) precast concrete slabs was evaluated and compared based on the vertical acceleration magnitude induced by walking and heel drop loads. Tests were conducted for practical building structures (a shopping mall in Hanam) of which floor systems used WAS and DT slabs. Natural frequencies of the slabs were similar to those obtained by using analytical models. The measured acceleration level was evaluated by vertical floor acceleration criteria presented by ISO-2631, AIJ(1991, Japan), and a previous study regarding floor vibration limit. Test results showed that both WAS and DT slabs satisfied all the criteria and the maximum acceleration level of WAS slabs was lower than that of DT slabs.

  • PDF

Development of Vibration Absorption Device for the Transportation-Trailer System (IV) - Connecting Hitch, Leaf Spring and Shock Absorber Suspension - (수송 트레일러의 충격흡수장치 개발 (IV) - 동력경운기 적재함의 연결히치, 판스프링, 쇽업쇼바 -)

  • Hong, Jong Ho;Wu, Yong Gen
    • Journal of Biosystems Engineering
    • /
    • v.37 no.6
    • /
    • pp.359-364
    • /
    • 2012
  • Purpose: This study was conducted to analyze the vibration absorption effect for the agricultural product transportation-trailer equipped with vibration absorbable connecting hitch, leaf spring suspension, and shock absorber simultaneously (HLS), comparing with the trailer equipped with vibration absorbable connecting hitch only(H), trailer equipped with connecting hitch and leaf spring suspension (HL), and existing trailer with no vibration absorption device (E). Methods: Vertical accelerations were measured at driver seat and front, middle, rear parts of trailer bottom with no load for 4 types of transportation-trailer, and analyzed using FFT analyzer. Results: The magnitude of average vibration accelerations occurred up to 20 Hz, at this low frequencies the severe damage for agricultural products could be represented, was lower (maximum 6 times) for HLS trailer compared with H trailer. And vibration absorption effect for HLS trailer was also higher up to 40-80 Hz and 80-100 Hz, but the difference was less. At driver seat, the vibration absorption effect was high severely for HL and HLS trailer, and the magnitude of vibration acceleration was showed less difference in comparing at trailer bottom. Conclusions: From the test results, it could be recommended that the agricultural products transportation trailer should be equipped with vibration absorption device of HLS.

Measurement Method of HDD Absolute Unbalance Magnitude and Position by measuring the Mobility (모빌리티 측정을 통한 하드디스크의 Unbalance 검출 및 보정방법)

  • Choe Hyeon;Kim In Ung;Lee Jae Won;Jeong Yong Gu;Choe Jeong Heon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.340.1-340
    • /
    • 2002
  • The unbalance exciting force induced by HDD of lately getting higher speed is directly influenced by the rotational speed and the mechanical assembly allowance between disk and spindle motor, and which gives rise to the structure borne noise of the personal computer. The absolute unbalance mass of HDD needs to be measured and adjusted by the counter mass to control the unbalance exciting force effectively in the stage of assembling the disk and spindle motor. This study introduces the measurement methods of the magnitude of the absolute unbalance mass and the position of HDD by 2 accelerometers. The absolute unbalance mass can be obtained by the acceleration responses and the mobility of the mechanical part, while the position of the unbalance mass can e obtained by the rotation acceleration orbit.

  • PDF

Acceleration Optimization of a High-speed LCD Transfer Crane Using Finite Jerk (고속 LCD 이송 시스템의 진동감소를 위한 Finite Jerk 적용 가속도 최적화)

  • Song Tae-Jin;Hong Dae-Sun;Kim Ho-Jong;Bang Duck-Je;Chung Won-Jee
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.3 s.180
    • /
    • pp.110-117
    • /
    • 2006
  • This paper presents the acceleration optimization of a high-speed LCD (Liquid Crystal Display) transfer system for the minimization of vibration. To reduce vibration is one of key requirements for the dynamic control of a high-speed LCD transfer system. In this paper, the concept of finite jerk (the first derivative of acceleration) has been introduced for realizing input acceleration. The profile of finite jerk has been optimized using a genetic algorithm so that vibration effect can be minimized. In order to incorporate a genetic algorithm, the dynamic model of a LCD transfer system which is realized by using the ADAMS software has been linked to the simulation system constructed by the MATLAB. The simulation results illustrated that the duration of finite jerk can be optimized so as to minimize the magnitude of vibration. It has been also shown that the acceleration optimization with finite jerk can make the high-speed motion of a LCD transfer system result in low vibration, compared with the conventional motion control with trapezoidal velocity profile.

A Study on Balanced-Type Oscillating Mole Drainer (II) (Model Test For Vibration) (평형식진동탄환암거천공기의 연구(II) -모수실험 : 진동에 대하여-)

  • 김용환
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.17 no.4
    • /
    • pp.3962-3969
    • /
    • 1975
  • 1. When the frame of the experimental apparatus was directly fixed on the platform, result from the spectrum density analysis showed that the generated vibration frequecy of the system was nearly-same as the system's own characteristic vibration frequency, 80Hz, in the case of the forcing vibration frequency was 7.5 to 22.5Hz. The reduction ratio of acceleration by balanced type model compare to non-balanced type one was 26.66 percent. 2. When the frame of experimental apparatus was fixed on the platform with putting a shock absorbing rubber between the frame and the platform, the generated vibration frequency of the system was same as forcing vibration frequency. When either frequency or the amplitude of the forcing vibration was increased, the acceleration ratio was increased too. The average reduction ratio was resulted 44.77 per cent. It was concluded that this method of acceleration measurement(the method using a shock absorbing rubber) was a reaonable method, because actual machine will work under such condition. As the vibration frequency and aptitude were increased, the absolute magnitude of acceleration was increased. 3. unbalanced rotating parts, and unbalanced moment of inertia of links were supposed to be causing factors of residual vibration in spite of using the balanced type oscillating mole drainer. This fact suggested that the attachment of the counter weight on the rotating parts which satisfy the condition mw$.$rw=m0e, was necessary. And also, it was expected that the shock absorbing effect could be improved by putting the shock absorbing materials between the moving parts and their supports.

  • PDF

Active Control of Structural Vibration Using An Instantaneous Control Algorithm including Acceleration Feedback (가속도가 포함된 순간최적제어 알고리듬을 이용한 구조물 진동의 능동제어)

  • 문석준;정태영
    • Journal of KSNVE
    • /
    • v.6 no.2
    • /
    • pp.215-224
    • /
    • 1996
  • Active vibration control is generally used to reduce vibration level by the actuators based on measured signal. Dynamic properties of a structure can be easily modified by the active vibration control, so that the vibration level may be effectively reduced to the magnitude below the allowable limit over a wide frequency rangs. In this paper, an instantaneous optimal control algorithm including acceleration feedback is presented for the active vibration control of large structures considering facts that the acceleration response can be easily measured, but the displacement and velocity response are obtained by numerically integrating the measured acceleration response with some errors. The adverse effect of the time delay is overcomed by taking into account the dynamic characteristics of an actuator and filters in the design of controller. Performance test is carried out using a hydraulic active mass driver on a test structure$(L{\times}W{\times}H;=;1200mm{\times}800mm{\times}1600mm, about;500kg)$ supported by four columns under base excitations. It is confirmed that the vibration level of the test structure are reduced to about 1/6 near resonance.

  • PDF

Review on Human Comfort Criteria in Tall Buildings (초고층건축물의 수평진동사용성 평가 기준의 재고)

  • Cho, Kang-Pyo;Jeong, Seung-Hwan;Cho, Gi-Sung;Km, Mu-Hwan
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2008.04a
    • /
    • pp.410-415
    • /
    • 2008
  • This paper presents review on human comfort criteria in major codes and standards for tall buildings. In general, human comfort criteria of tall buildings have been used by magnitude of wind-induced acceleration response. Two different indexes in determination of the magnitude have been used: the peak value which occurs during a period of time and the rms value averaged over this same period. These distinctive acceleration indexes are discussed in detail and each criterion is reviewed and compared. The distinctions arisen because of the different wave forms, or acceleration signatures are addressed. It is described that which index of acceleration should be adopted in establishment of Korean human comfort criteria. In addition, some arguments from a technical standpoint that favor the use of each index are presented.

  • PDF