• 제목/요약/키워드: veterinary radiation workers

검색결과 6건 처리시간 0.021초

동물병원 방사선 안전관리체계에 대한 연구 (Study of Radiation Safety Management of Veterinary Hospital in Korea)

  • 채수영;최호정;이영원
    • 한국임상수의학회지
    • /
    • 제37권1호
    • /
    • pp.15-22
    • /
    • 2020
  • This study investigated the effectiveness of radiation safety rules in animal hospital and the awareness and behavior of veterinary radiation workers. With the questionnaires, the data was collected from randomly selected veterinarians in animal hospitals and animal medical imaging centers. Collected data were about radiation device, shielding device, regulations, safety management, education, knowledge, behavior and awareness. Frequency, correlation and multiple regression analysis were performed. The medical devices related with radiation in animal hospital were X-ray (59%), CT (15%), fluoroscopy (12%), mobile X-ray (12%) and others (2%). The number of people using radiation shielding device is high. The answers were low on knowing radiation related regulation and receiving radiation protection education. The group with higher knowledge and awareness shows positive correlation with safety behavior. The increase of use of the radiation related medical devices in veterinary hospital causes the increase of radiation exposure risk. This study suggests that radiation safety management system and policies need to be developed to protect radiation workers and give them correct information and consciousness.

국내 동물병원의 진단용 방사선 발생장치 및 방사선 관계종사자 안전관리에 관한 융복합적 분석 (Convergence analysis of safety management for radiation workers and diagnostic radiation-generator devices of animal hospital in Korea)

  • 강경묵;서태영;김용상;윤선종
    • 한국융합학회논문지
    • /
    • 제11권4호
    • /
    • pp.55-61
    • /
    • 2020
  • 다양한 종류의 방사선 발생장치가 동물병원에서 사용되면서 방사선 관계종사자들의 안전이 중요해지고 있으나 방사선 발생장치 및 방사선 관계종사자들에 대한 안전관리 정보가 없는 실정이다. 이에 본 연구에서는 방사선 검사기관 및 측정기관, 시·군·구에서 조사되어진 방사선 발생장치 및 관계종사자, 피폭선량 등을 조사, 분석하였다. 최근 6년간 동물병원에서의 방사선 발생장치와 관계종사자 수는 각각 2,138대에서 2,972대, 2,644명에서 5,733명으로 증가하였다. 2019년 방사선 발생장치의 수는 일반 X-ray, CT, C-arm, 이동형 X-ray, 치과용 X-ray는 각각 2,204대, 58대, 67대, 770대, 14대인 것으로 조사되었다. 2019년 방사선 관계종사자 수는 수의사 4,236명, 수의간호사 1,080명, 업무보조원 404명, 기타 13명인 것으로 조사되었다. 2018년 방사선 관계종사자 연간평균피폭선량은 표층선량 0.21mSv, 심부선량 0.18mSv인 것으로 나타났다. 본 연구는 동물병원에서 사용하고 있는 방사선 발생장치 및 방사선 관계종사자의 안전관리에 대한 기초 자료가 될 것으로 기대한다.

A New Radiation-Shielding Device for Restraining Veterinary Patients

  • Songyi Kim;Minju Lee;Miju Oh;Yooyoung Lee;Jiyoung Ban;Jiwoon Park;Sojin Kim;Uhjin Kim;Jaepung Han;Dongwoo Chang
    • 한국임상수의학회지
    • /
    • 제40권6호
    • /
    • pp.429-437
    • /
    • 2023
  • In veterinary medicine, most radiographic images are obtained by restraining patients, inevitably exposing the restrainer to secondary scattered radiation. Radiation exposure can result in stochastic reactions such as cancer and genetic effects, as well as deterministic reactions such as skin burns, cataracts, and bone marrow suppression. Radiation-shielding equipment, including aprons, thyroid shields, eyewear, and gloves, can reduce radiation exposure. However, the risk of radiation exposure to the upper arms, face, and back remains, and lead aprons and thyroid shields are heavy, restricting movement. We designed a new radiation-shielding system and compared its shielding ability with those of conventional radiation-shielding systems. We hypothesized that the new shielding system would have a wider radiation-shielding range and similar shielding ability. The radiation exposure dose differed significantly between the conventional and new shielding systems in the forehead, chin, and bilateral upper arm areas (p < 0.001). When both systems were used together, the radiation-shielding ability was better than when only one system was used at all anatomical locations (p < 0.01). This study suggests that the new radiation-shielding system is essential and convenient for veterinary radiation workers because it is a step closer to radiation safety in veterinary radiography.

동물병원의 진단용 방사선 발생장치 및 방사선종사자 안전관리 실태 조사 (Radiation safety management for diagnostic radiation generators and employees in animal hospitals in Korea)

  • 안효진;김충현;권영진;김돈환;위성환;문진산
    • 대한수의학회지
    • /
    • 제54권3호
    • /
    • pp.151-157
    • /
    • 2014
  • A nationwide survey on radiation safety management in Korean animal hospitals was conducted. By 2013, 53 radiation generators were registered as veterinary medical devices (41 X-ray generators and 12 computed tomography scanners). Additionally there were six approved laboratories for radiation equipment and protection facility, and five approved laboratories for radiation exposure of employees, respectively. By March 2013, 2,030 out of 3,829 animal hospitals operated radiation-generating devices. Among these devices, 389 (19.2%) out of 2,030 were not labeled with the model name and 746 (36.7%) were not labeled with production dates. Thus, most veterinary X-ray generators were outdated (42.6%) and needed replacements. When periodic inspections of 2,018 animal hospitals were performed after revision of the Veterinarians Act in 2011, the hospitals were found to be equipped with appropriate radiation generators and protection facilities. Among 2,545 employees exposed to radiation at the hospitals, 93.9% were veterinarians, 4.3% were animal nurse technicians, and 18% held other positions. Among 169 employees supervised by administrators, none of those had a weekly maximum operating load that exceeded $10mA{\cdot}min$. This study suggests that the radiation safety management system of animal hospitals was general good.

Radioiodine의 체내오염(體內汚染)에 대(對)한 긴급처치연구(緊急處置硏究) (Studies on the internal decontamination of radioiodine)

  • 정인용;김태환;정현우;진수일;윤택구
    • 대한수의학회지
    • /
    • 제28권2호
    • /
    • pp.391-396
    • /
    • 1988
  • Appreciable radiation exposures certainly occur in the workers who handle radioiodine in biochemical research, nuclear medicine diagnostics with the development of nuclear industries. But in the case of occurring the nuclear accidents, the early medical treatment of radiation injury should be necessary but little was reported in korea till now. Accordingly, to achieve of the basic data for protective roles and medical treatment of radiation injury, the present studies were carried out to evaluate the decontamination of radioiodine by the administration of the antithyroid drugs. The results observed are summarized as follows: 1. The administration of sodium iodide and potassium iodide results in rapid excretion of radioiodine and reduction of the whole body retention than the saline-only group. 2. Reguarding to thyroid protective effects, sodium iodide, potassium iodide and saline were effected significant in order. 3. In the control(saline) group, if administered with enough fluids, the whole body retention of radioiodine is reduced temporary shifts. But as far as radioprotective effects is concerned, saline was not more in the protective effects than the other groups. In conclusion, in case of nuclear accidents, if being administered sodium iodide and saline as quickly as possible, the radioprotective effects against the radiation hazard might be markedly increased in the internal contamination of radioiodine.

  • PDF

The Japan Health Physics Society Guideline on Dose Monitoring for the Lens of the Eye

  • Yokoyama, Sumi;Tsujimura, Norio;Hashimoto, Makoto;Yoshitomi, Hiroshi;Kato, Masahiro;Kurosawa, Tadahiro;Tatsuzaki, Hideo;Sekiguchi, Hiroshi;Koguchi, Yasuhiro;Ono, Koji;Akiyoshi, Masahumi;Kunugita, Naoki;Natsuhori, Masahiro;Natsume, Yoshinori;Nabatame, Kuniaki;Kawashima, Tsunenori;Takagi, Shunji;Ohno, Kazuko;Iwai, Satoshi
    • Journal of Radiation Protection and Research
    • /
    • 제47권1호
    • /
    • pp.1-7
    • /
    • 2022
  • Background: In Japan, new regulations that revise the dose limit for the lens of the eye (hereafter the lens), operational quantities, and measurement positions for the lens dose were enforced in April 2021. Based on the international safety standards, national guidelines, the results of the Radiation Safety Research Promotion Fund of the Nuclear Regulation Authority, and other studies, the Working Group of Radiation Protection Standardization Committee, the Japan Health Physics Society (JHPS) developed a guideline for radiation dose monitoring for the lens. Materials and Methods: The Working Group of the JHPS discussed the criteria of non-uniform exposure and the management criteria set not to exceed the dose limit for the lens. Results and Discussion: In July 2020, the JHPS guideline was published. The guideline consists of three parts: main text, explanations, and 26 examples. In the questions, the corresponding answers were prepared, and specific examples were provided to enable similar cases to be addressed. Conclusion: With the development of the guideline on radiation dose monitoring of the lens, radiation managers and workers will be able to smoothly comply with revised regulations and optimize radiation protection.