• 제목/요약/키워드: vessel size

검색결과 538건 처리시간 0.027초

원자로 용기 외벽냉각을 위한 1차원 이상유동 실험 및 해석 (1-D Two-phase Flow Investigation for External Reactor Vessel Cooling)

  • 김재철;박래준;조영로;김상백;김신;하광순
    • 대한기계학회논문집B
    • /
    • 제31권5호
    • /
    • pp.482-490
    • /
    • 2007
  • When a molten corium is relocated in a lower head of a reactor vessel, the ERVC (External Reactor Vessel Cooling) system is actuated as coolant is supplied into a reactor cavity to remove a decay heat from the molten corium during a severe accident. To achieve this severe accident mitigation strategy, the two-phase natural circulation flow in the annular gap between the external reactor vessel and the insulation should be formed sufficiently by designing the coolant inlet/outlet area and gap size adequately on the insulation device. For this reason, one-dimensional natural circulation flow tests and the simple analysis were conducted to estimate the natural circulation flow under the ERVC condition of APR1400. The experimental facility is one-dimensional and scaled down as the half height and 1/238 channel area of the APR1400 reactor vessel. The calculated circulation flow rate was similar to experimental ones within about ${\pm}$15% error bounds and depended on the form loss due to the inlet/outlet area.

Metastasis via Peritumoral Lymphatic Dilation in Oral Squamous Cell Carcinoma

  • Kim, Han-Seok;Park, Young-Wook
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제36권3호
    • /
    • pp.85-93
    • /
    • 2014
  • Purpose: Nodal metastasis is the main prognostic factor in the patients with oral squamous cell carcinoma (OSCC). We investigated the association between tumor-associated lymphatics and OSCC characteristics. Methods: Thirty-four specimens were used for the immunohistochemical staining with the antibody for vascular endothelial growth factor (VEGF)-C, VEGF-D, VEGF receptor (VEGFR)-3, phosphorylated VEGFR-3, D2-40, and matrix metallproteinases (MMPs). We observed the distribution of the lymphangiogenic factors and quantified the degree of expression. We determined lymphatic vessel density (LVD) and lymphatic vessel dilatation with D2-40 immunostaining. We assessed the association of LVD or lymphatic vessel dilatation with tumor progression or tumor differentiation. Results: OSCC cells expressed lymphangiogenic ligands. Lymphangiogenic receptor, VEGFR-3, was expressed and activated in some tumor cells as well as in tumor-associated endothelial cells. LVD was not associated with tumor size or nodal status, but lymphatic vessel dilatation was higher in tumors with nodal metastasis, and also higher in poorly differentiated tumors. In stromal area of OSCC, MMP-1 and MMP-10 were up-regulated and the basement membrane of tumor-associated endothelial cells was destroyed by these collagenases. Conclusion: In the primary tumors with nodal metastasis, especially in poorly differentiated OSCC, tumor cells invaded the dilated lymphatic vessels via ruptured sites. MMP-1 and MMP-10 are important in the lysis of the glycocalyx inside the tumor-associated lymphatic endothelial cells.

A Brachial Artery Pseudoaneurysm Treated with a Bifurcated Y-Shaped Artificial Vessel Graft

  • Joon seok Oh;Seokchan Eun
    • Archives of Plastic Surgery
    • /
    • 제49권6호
    • /
    • pp.755-759
    • /
    • 2022
  • Brachial artery aneurysms are rare diseases that may be caused by infection or trauma. We report a case of a 71-year-old man who presented with a mass in his right antecubital fossa that increased in size slowly over time. Three years ago, the patient underwent ascending and total-arch replacement with artificial vessel graft to treat aortic root and ascending aorta aneurysm. Preoperative physical examination of right upper extremity showed a nonpulsatile mass with normal pulse of axillary, brachial, and radial arteries. The mass was removed and brachial artery reconstruction was done initially using saphenous vein graft. Two months later, the patient revisited with recurrent pseudoaneurysm, involving the bifurcation point of brachial artery. Aneurysm was totally resected and the brachial artery was reconstructed by interposition graft using a bifurcated GORE-TEX artificial vessel graft. The patient healed without complication and no recurrence was observed. Artificial vessel graft is an available option for reconstruction, and revascularization of vessel defect after excision of brachial artery aneurysm may involve bifurcation point.

Contribution of Microbleeds on Microvascular Magnetic Resonance Imaging Signal

  • Chang Hyun Yoo;Junghwan Goh;Geon-Ho Jahng
    • 한국의학물리학회지:의학물리
    • /
    • 제33권4호
    • /
    • pp.88-100
    • /
    • 2022
  • Purpose: Cerebral microbleeds are more susceptible than surrounding tissues and have been associated with a variety of neurological and neurodegenerative disorders that are indicative of an underlying vascular pathology. We investigated relaxivity changes and microvascular indices in the presence of microbleeds in an imaging voxel by evaluating those before and after contrast agent injection. Methods: Monte Carlo simulations were run with a variety of conditions, including different magnetic field strengths (B0), different echo times, and different contrast agents. ΔR2* and ΔR2 and microvascular indices were calculated with varying microvascular vessel sizes and microbleed loads. Results: As B0 and the concentration of microbleeds increased, 𝜟R2* and 𝜟R2 increased. 𝜟R2* increased, but 𝜟R2 decreased slightly as the vessel radius increased. When the vessel radius was increased, the vessel size index (VSI) and mean vessel diameter (mVD) increased, and all other microvascular indices except mean vessel density (Q) increased when the concentration of microbleeds was increased. Conclusions: Because patients with neurodegenerative diseases often have microbleeds in their brains and VSI and mVD increase with increasing microbleeds, microbleeds can be altered microvascular signals in a voxel in the brain of a neurodegenerative disease at 3T magnetic resonance imaging.

Maintaining High Standard Flag State Administrations for Combating Vessel-Source Marine Pollution

  • Lee, Dr. Sang-jib
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 1995년도 춘계학술발표회 논문집
    • /
    • pp.59-64
    • /
    • 1995
  • The impediment in enhancing the ship safety and combating vessel-source marine pollution depends on the combination of the immediate and mediate factors. The former is mainly caused by human errors and failure in compliance with the international convention standards in operation of compliance with the international convention standards in operation of vessel. The latter by the attitudes and activities of some of the flay states taking little responsibilities with appropriate seriousness in policing their fleets due to the lack of implementing capability of adminstrations. So long as there exists a large size of variation in implementing capability of administration between flag states a globally remarked progress cannot expect to be made in assuring the ship safety and preventing the vessel-source pollution Therefore a new regulatory regime is suggested to be adopted by IMO to maintain high standard flag state adminstrations by recommending standard paradigm to member states so that the development of a implementing culture is encouraged and supported.

  • PDF

강재 충돌방호공의 선박충돌력산정 (A bridge-vessel collision force of steel fender system)

  • 이계희;고재용;유원진
    • 해양환경안전학회:학술대회논문집
    • /
    • 해양환경안전학회 2003년도 추계학술발표회
    • /
    • pp.127-133
    • /
    • 2003
  • In this study, the impact analysis for the steel fender system that designed for protection of collision between vessel and bridge was performed The size of objective collision vessel assumed as 3000 dead weight tonnage(DWT). The impact forces and the impact energies were estimated by formulas of several design codes, and the steel fender system was designed based on the estimated forces and energy. The bow of objective vessel was modeled as rigid body, and bridge substructure was modeled as fixed support. Since, the impact analysis have the dynamic nonlinear features, such as, material nonlinear, large deformation and contact, explicit structural analysis program was used The analysis results presented that the impact forces formulas in codes have the sufficient conservativeness.

  • PDF

영광 원자력 발전소 원자로 소재의 가동전 재료 물성 특성 (Evaluation of the Preirradiation Baseline Material Characteristics for Yonggwang Nuclear Reactor Pressure Vessel)

  • 김국철;김정태;석진익;권희경;성운학
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집A
    • /
    • pp.153-158
    • /
    • 2000
  • Nuclear reactor pressure vessel should be safety even in the case that hypothetical defects with allowable size are in vessel. Therefore, the materials should have excellent fracture resistance characteristics. The purpose of this study is to analyze the results of preirradiation baseline test of nuclear pressure vessel for Yonggwang Unit 5/6. In experiments, drop weight tests and impact tests are carried out to obtain nil-ductility transition reference temperature, $RT_{NDT}$ and static and dynamic fracture toughness tests are performed to compare with $K_{IR}$ curve in accordance with ASME Sec.III. The test results show that the materials had sufficiently fracture resistance characteristics for 40 years of design life.

  • PDF

냉연신 공법을 이용한 압력용기의 제조에 관한 연구 (A Study on Pressure Vessel using Cold Stretch Method)

  • 한규택
    • 한국기계가공학회지
    • /
    • 제17권1호
    • /
    • pp.153-160
    • /
    • 2018
  • A pressure vessel consists of an inner tank and the outer tank; the material of the inner tank is austenite stainless steel, and the outer tank is general carbon steel. As the storage amount increase, the size of the inner tank for LNG also increases, which eventually increases the weight of the LNG storage tank. The Cold Stretch method can transport and store the LNG in a larger amount than the conventional pressure container, and the weight of the pressure vessel can also be reduced at 50 70% due to the reduction of the thickness, which is excellent from an economic and energy consumption perspective. Although the Cold Stretch method has these advantages, the domestic situation has not developed any related legislation. In this study, the actual production of pressure vessels using the Cold Stretch method will be processed and the volume expansion after the Cold Stretch will be checked and compared with the mechanical properties.

강재 충돌방호공의 선박충돌해석 (A bridge-vessel collision analysis of steel fender system)

  • 이계희;홍현석;백종균
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.71-78
    • /
    • 2003
  • In this study, the impact analysis for the steel fender system that designed for protection of collision between vessel and bridge was peformed. The size of objective collision vessel assumed as 3000 dead weight tonnage(DWT). The impact forces and the impact energies were estimated by formulas of several design codes, and the steel fender system was designed based on the estimated forces and energy. The bow of objective vessel was modeled as rigid body, and bridge substructure was modeled as fixed support. Since, the impact analysis have the dynamic nonlinear features, such as, material nonlinear, large deformation and contact, explicit structural analysis program was used. The analysis results presented that the impact forces formulas in codes have the sufficient conservativeness.

  • PDF

물오리나무와 사방오리나무에 있어서 도관요소 및 섬유의 칫수 변이 (Dimensional Variation of Vessel Element and Fiber in Alnus hirsuta and A. firma)

  • 소웅영;한경식
    • Journal of Plant Biology
    • /
    • 제28권1호
    • /
    • pp.9-20
    • /
    • 1985
  • 물오리나무와 사방오리나무의 뿌리 줄기 및 가지에 있어서 목부요소의 크기의 변이에 관해서 연구하였다. 도관요소의 직경은 뿌리에서 가장 넓고 그 다음은 줄기이며 가지에서 가장 좁다. 그런데 도관요소의 길이는 줄기에서 가장 길고 다음은 뿌리이며 가지에서 가장 짧은 것으로 밝혀졌다. 섬유의 직경 및 길이는 뿌리에서 가장 넓고 길며 그 다음은 줄기 가지의 순이다. 각 기관의 일정위치에서 중심부로부터 연륜이 증가함에 따라 목부요소의 크기는 뚜렷하게 증가되었다.

  • PDF