• Title/Summary/Keyword: vertical testing

Search Result 333, Processing Time 0.022 seconds

Parametric Study of Rectangular Coil for Eddy Current Testing of Lamination

  • Wang, Pengfei;Zeng, Zhiwei
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.2
    • /
    • pp.155-159
    • /
    • 2016
  • Eddy current testing (ECT) is an important nondestructive testing technology for the inspection of flaws in conductive materials. However, this widely used technology is not suitable for inspecting lamination when a conventional pancake coil is used because the eddy current (EC) generated by the pancake coil is parallel to the lamination and will not be perturbed. A new method using a rectangular coil placed vertical to the work piece is proposed for lamination detection. The vertical sections of the rectangular coil induce ECs that are vertical to the lamination and can be perturbed by the lamination. A parametric study of a rectangular coil by finite element analysis was performed in order to examine the capability of generating vertical EC.

Angle Beam Ultrasonic Testing Models and Their Application to Identification and Sizing of Surface Breaking Vertical Cracks

  • Song, Sung-Jin;Kim, Hak-Joon;Jung, Hee-Jun;Kim, Young-H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.6
    • /
    • pp.627-636
    • /
    • 2002
  • Identification and sizing of surface breaking vertical cracks using angle beam ultrasonic testing in practical situation quite often become very difficult tasks due to the presence of non-relevant signals caused by geometric reflectors. The present work introduces effective and systematic approaches to take care of such a difficulty by use oi angle beam ultrasonic testing models that can predict the expected signals from various targets very accurately. Specifically, the model-based TIFD (Technique for Identification of Flaw signals using Deconvolution) is Proposed for the identification of the crack tip signals from the non-relevant geometric reflection signals. In addition, the model-based Size-Amplitude Curve is introduced for the reliable sizing of surface breaking vertical cracks.

An Experiment of Traceability-Driven System Testing

  • Choi, Eun-Man;Seo, Kwang-Ik
    • Journal of Information Processing Systems
    • /
    • v.4 no.1
    • /
    • pp.33-40
    • /
    • 2008
  • Traceability has been held as an important factor in testing activities as well as model-driven development. Vertical traceability affords us opportunities to improve manageability from models and test cases to a code in testing and debugging phase. This paper represents a vertical test method which connects a system test level and an integration test level in testing stage by using UML. An experiment how traceability works to effectively focus on error spots has been included by using concrete examples of tracing from models to the code.

Modal Analysis In The Dynamic Behavior Identification of the fluid-structure coupled Vertical Pump (유체와 구조물이 조합된 대형 수직펌프의 동특성 개선)

  • 배춘희;조철환;김성휘;박영필
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.622-627
    • /
    • 2001
  • The paper presents the possibilities of a wide practical application of the modal analysis methods in dynamic testing of vertical pump. A pneumatic impact of testing vertical pumps submerged under deep water was developed and successfully applied. The problem with the enviroment is the it causes significants changes in modal parameters, compared with those in the airenviroment.

  • PDF

Vertical System Testing Method For Efficient Error Tracing (효과적인 오류 추적을 위한 수직적 시스템 시험 방법)

  • Seo, Kwang-Ik;Choi, Eun-Man
    • Journal of the Korea Society of Computer and Information
    • /
    • v.13 no.2
    • /
    • pp.19-29
    • /
    • 2008
  • In case of unit testing, White-box test can be used to closely check source code and to analyze logic and statement errors. On the other hand, in case of function testing of system level, Black-box test can be mainly used to compare actual and expected results by inputting test data because the scale of function is large. This Black-Box test in system testing level has problem in tracing errors in source code when we find errors. Moreover applying White-box test is not easy for system testing level because the levels of test target are different. Therefore this paper suggests the vertical test method of a practical and integrated system level which can checks up to source code level using White-box test style although it aims to test the highly abstract level like a system function. In addition, the experiment explains how to apply the vertical test by displaying an example which traces from UML specification model to the source code and also shows efficiency of error trace.

  • PDF

Rigorous System Testing by Supporting Vertical Traceability (수직 추적가능성을 제공하는 엄격한 시스템 테스트)

  • Seo, Kwang-Ik;Choi, Eun-Man
    • The KIPS Transactions:PartD
    • /
    • v.14D no.7
    • /
    • pp.753-762
    • /
    • 2007
  • Traceability has been held as an important factor in testing activities as well as model driven development. Vertical traceability affords us opportunities to improve manageability from models and test cases to code in testing and debugging phase. Traceability also makes overcome to difficulties of going up-and-down abstraction level to find out error spot of faults discovered by testing This paper represents a vertical test method which connects a system test level and an integration test level in a test stage by using UML. Experiment of how traceability works and how effective focus on error spots has been included using concrete examples of tracing from models to the code.

Influence of Stacking Sequence Conditions the Absorbed Energy Characteristics of Composite Tubes (경량화용 복합재 튜브의 적층구성이 흡수에너지 특성에 미치는 영향)

  • Kim, Yeong-Nam;Kim, Ji-Hun;Yang, In-Yeong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.11
    • /
    • pp.34-41
    • /
    • 2001
  • This study is to investigate the energy absorption characteristics of CFRP(Carbon-Fiber Reinforced Plastics) tubes on static and dynamic tests. Axial static compression tests have been carried out using the static testing machine(Shin-gang buckling testing machine) and dynamic compression tests have been utilized using an vertical crushing testing machine. When such tubes are subjected to crushing loads, the response is complex and depends on the interaction between the different mechanisms that could control the crushing process. The collapse characteristics and energy absorption have been examined for various tubes. Energy absorption of the tubes are increased as changes in the lay-up which may increase the modulus of tubes. The results have been varied significantly as a function of ply orientation and interlaminar number.

  • PDF

Flaw Detection in Ceramics using Hough transform and Least squares

  • Hong, Dong-Jin;Cha, Eui-Young
    • Journal of the Korea Society of Computer and Information
    • /
    • v.20 no.10
    • /
    • pp.23-29
    • /
    • 2015
  • In this paper, we suggest a method of detecting defects by applying Hough transform and least squares on ceramic images obtained from non-destructive testing. In the ceramic images obtained from non-destructive testing, the background area, where the defect does not exist, commonly show gradual change of luminosity in vertical direction. In order to extract the background area which is going to be used in the detection of defects, Hough transform is performed to rotate the ceramic image in a way that the direction of overall luminosity change lies in the vertical direction as much as possible. Least squares are then applied on the rotated image to approximate the contrast value of the background area. The extracted background area is used for extracting defects from the ceramic images. In this paper we applied this method on ceramic images acquired from non-destructive testing. It was confirmed that extracted background area could be effectively applied for searching the section where the defect exists and detecting the defect.

A Study on the Integrity Evaluation of the Windings in Cast Resin Transformers Using Vertical Thermal Distribution Analysis (수직온도분포 분석을 이용한 몰드변압기 권선의 건전성 평가 연구)

  • Lim, Young-Bae
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.315-319
    • /
    • 2004
  • This paper presents the integrity evaluation method of the windings in cast resin transformers using vertical thermal distribution analysis. The method is to compare the temperature distribution in a sound condition specimen with that in the failure condition specimen layer-shorted by accelerated testing. The temperature distribution was acquisited by a infrared thermography system, and the Arrhenius equation was adopted to the accelerated testing. The proposed method may be available to detect the failures in cast resin transformers.

  • PDF

Theoretical Consideration of Nondestructive Testing by use of Vertical Magnetization and Magneto-Optical Sensor

  • Lee, Jinyi;Tetsuo Shoji;Dowon Seo
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.640-648
    • /
    • 2004
  • This paper describes a new magnetization method for non-destructive testing with magneto-optical sensor (denoted as MO sensor) which have the following characteristic : high observation sensitivity, independence of the crack orientation, and precise imaging of a complex crack geometry such as multiple cracks. When a magnetic field is applied normally to the surface of a specimen which is significantly larger than its defects, approximately the same magnetic charge per unit area occurs on the surface of the specimen. If there is a crack in the specimen, magnetic charge per unit area has the same value at the bottom of the crack. The distribution of the vertical component of the magnetic flux density, B$\_$Z/, is almost uniform over the no-crack area (denoted as B$\_$Z,BASE/), while the magnetic flux density is smaller in the surroundings of the crack(denoted as B$\_$Z,CRACK/) If B$\_$Z, BASE/ is a bit larger than the saturated magnetic flux density of the MO sensor (B$\_$s/) , then small magnetic domains occur over the crack area and a large domain over the non-crack area because B$\_$Z,CRACK/ is smaller than B$\_$s/.