• Title/Summary/Keyword: vertical size

Search Result 1,198, Processing Time 0.026 seconds

Vertical Aerosol Distribution and Flux Measurement in the Planetary Boundary Layer Using Drone (드론을 이용한 안면도 상공 대기경계층내의 미세먼지 연직분포 및 Flux 측정)

  • Kim, Heesang;Park, Yonghe;Kim, Wooyoung;Eun, Heeram;Ahn, Kang-Ho
    • Particle and aerosol research
    • /
    • v.14 no.2
    • /
    • pp.35-40
    • /
    • 2018
  • Vertical particle size distribution, total particle concentration, wind velocity, temperature and humidity measurement was performed with a drone. The drone was equipped with a wind sensor, house-made optical particle count(Hy-OPC), condensation particle counter(Hy-CPC), GPS, Temperature, Relative Humidity, Pressure and communication system. Base on the wind velocity and the particle size vertical distribution measurement with drone, the particle mass flux was calculated. The vertical particle distribution showed that the particle number concentration was very strongly correlated with the relative humidity.

The Effects of Size and Array of N-GaN Contacts on Operation Voltage of Padless Vertical Light Emitting Diode (N-GaN 접촉 전극의 크기 및 배열 변화에 따른 패드리스 수직형 발광다이오드의 구동전압의 변화에 관한 연구)

  • Rho, Hokyun;Ha, Jun-Seok
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.21 no.1
    • /
    • pp.19-23
    • /
    • 2014
  • For the application of light-emitting diodes (LEDs) for general illumination, the development of high power LEDs chips became more essential. For these reasons, recently, modified vertical LEDs have been developed to meet various requirements such as better heat dissipation, higher light extraction and less cost of production. In this research, we investigate the effect of Size and Array of N-GaN contact on operation voltage with new structured padless vertical LED. We changed the size and array of N-electrodes and investigated how they affect the operation voltage of LEDs. We simulated the current crowding and expected operation voltage for different N-contact structures with commercial LED simulator. Also, we fabricated the padless vertical LED chips and measured the electrical property. From the simulation, we could know that the larger size and denser array of n-electrodes could make operation voltage decrease. These results are well in accordance with those measured values of real padless vertical LED chips.

Factors Affecting on Organizational Commitment of Hospital Employees (병원조직 구성원의 직장애착에 영향을 미치는 요인)

  • 이상곤;감신;박재용;한창현;김건엽;이원기;차병준
    • Health Policy and Management
    • /
    • v.9 no.1
    • /
    • pp.201-233
    • /
    • 1999
  • This study was carried out to find out the factors affecting on organizational commitment of hospital employees. For the purpose, the questionnaire-based research was done with 1280 hospital employees who were working in 2 university hospitals and 4 general hospitals located in Taegu City and Kyungpook Province from November 20, 1997 to December 22, 1997. The results of the study were summarized as follows. There were significant correlations among environmental variables, psychological variables, structural variables, vertical conflict, horizontal conflict, job satisfaction, and organizational commitment. By path analysis, variables such as pay, work involvement, work definiteness, met expectations, positive affectivity, distributive justice, job security, expectations before entering a hospital had significant positive effect on job satisfaction in order of size, while, vertical conflict, job opportunity, and horizontal conflict had significant positive effect on job satisfaction in order of size, while, vertical conflict, job opportunity, and horizontal conflict had signifecant negative effect in order of size. Variables such as job satisfaction, job security, work involvement, pay, vertical conflict, met expectations, distributive justice, positive affectivity, work unit control, job autonomy, and job routinization had significant positive direct effect on organizational commitment in order of size, while, job opportunity, job hazards and resource inadequacy had significant negative direct effects in order of size. It was found that the following variables, listed in order of size, had significant total effects on organizational commitment : job satisfaction, job security, job opportunity, work involvement, pay, met expectations, distributive justice, positive affectivity, job hazards, and work unit control. In considering abovc findings, it is recommended that programs for job satisfaction promotion, job security, decrease of intent to leave, work involvement promotion, adequate pay, met expectations, distributive justice, positive affectivity promotion, job hazards decrease, and work unit control grant should be implemented to increase organizational commitment.

Torso shape study of older women considering the senior shift (시니어 시프트를 고려한 고령 여성의 체간부 체형 연구)

  • Kim, A-Young;Uh, Mi-Kyung
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.21 no.4
    • /
    • pp.115-126
    • /
    • 2019
  • The purpose of this study is to analyze the characteristics of older women's torso shapes. The data was collected from the 7th Size Korea, which featured 453 women between the ages of 70-85. A factor analysis was performed of 31 indices, including seventeen based on height and length measurements, eight based on circumference measurements, and six based on torso flattening. The torso shape was determined from seven factors: torso flatness ratio, shape of the side upper torso, vertical size of upper torso, silhouette of the torso, silhouette of the bust and abdomen, shape of the hip, and the vertical size of the back of upper torso. The torso shapes of older women were classified into three types based on the results of the factor analysis. Type 1 is called the large rectangle type. They have the lowest degree of forward bend in the torso, the largest vertical and horizontal size, a round body shape, and the upper torso is gently curved. Type 2 is called the inverted triangle type. They also have a round body shape, but the abdominal size is relatively small compared to the size of the bust, and also have an open and drooping bust, and the biggest degree of forward bend in the torso. Type 3 is called the square type. They are characterized by drooping hips, the smallest vertical and horizontal sizes, and the gentlest curve of the torso.

The Experimental Investigations of the Big Size Holographic Screen in the Autostereoscopic Displays

  • Son, J. Y.;Choi, Y. J.;Bahn, J. E.;Bobrinev, V.-I.
    • Journal of the Optical Society of Korea
    • /
    • v.5 no.2
    • /
    • pp.55-59
    • /
    • 2001
  • Results of an experimental study of possible ways to extend the capabilities of a big size transmission type holographic screen are presented. Different approaches to the problem of making a big size screen have been considered and tested experimentally. Up to 60$\times$80 $\textrm{cm}^2$ screens have been recorded on a single photographic plate VRP-M. By attaching a mirror behind the screen, the reflection mode of operation has been obtained. In this arrangement some additional peculiarities appear in the screen, which can be used to extend the screen capabilities. The first possibility is to increase the screen size by mosaicking the subscreens in the reflection mode of operation. Screens of 120$\times$80 $\textrm{cm}^2$ and 180$\times$40 $\textrm{cm}^2$ have been obtained by proper alignment of 60$\times$40 $\textrm{cm}^2$ subscreens. The second possibility is to move the viewing Bone by rotation of the screen together with the mirror and thereby realize by the eye-tracking capability. Methods of increasing vertical size of the viewing zone have been considered. Along with the multi-exposure method, which was considered in previous papers, addition of the vertical diffuser with the optimized scattering angle has been tested experimentally. The vertical size of the viewing zone has been increased by up to 10-15 cm. Another method consists of usage of a diffraction grating with vertical dispersion to solve the same problem.

A Study on the Scale and Dimensions of member of Sectional structure for Five-Purlin Houses from Joseon Era (조선시대 민가 오량가(五樑架) 종단구성의 규모와 부재치수에 관한 연구)

  • Kim, Jae-Ung
    • Journal of architectural history
    • /
    • v.28 no.1
    • /
    • pp.7-16
    • /
    • 2019
  • As a part of the research on existing structures of private homes from Joseon Era. Focusing on one hundred twenty five-purlin houses, the current study investigated the features and characteristics of the house structure from style, size, proportion and roof pitch, and measurements of key parts, and developed the following conclusions. Most are single-houses (89, 83%), and among them, there are 47 single front-terrace houses (39%), which is the highest number. The sizes of lower house structure do not differ greatly depending on the vertical structure, and single rear terrace house and double-house have relatively larger side sizes. The size of upper structure is larger in double-houses compared to other vertical structures, indicating a relatively higher roof. The cross-section measurement of major parts show that double-houses are larger than single-houses by 3cm in pillar, 3-4.5cm in crossbeam length, and 4.5cm in crossbeam width. However, Janghyeo width was consistent at 7.5 to 10.5cm, maintaining uniformity regardless of vertical structure of the houses. In addition, the cross-section measurements decreased from sixteenth to nineteenth century, with the size of pillar size decreasing the most. The result that the Janghyeo width is not related to the house structure house confirmed that the Janghyeo width was kept consistent regardless of the size of the house structure.

Effect of Shoe Size on Foot Pressure, Ground Reaction Force, and Fatigue During Walking and Running (보행과 달리기 시 신발의 크기가 족저압과 지면반발력, 하지의 근피로에 미치는 영향)

  • Kim, Tack-Hoon
    • Physical Therapy Korea
    • /
    • v.15 no.1
    • /
    • pp.1-11
    • /
    • 2008
  • The purpose of this study was to assess the influence of two shoe size conditions on foot pressure, ground reaction force (GRF), and lower extremity muscle fatigue. Seven healthy men participated. They randomly performed walking and running in two different conditions: proper shoe size and 10 mm greater than proper shoe size. Peak foot pressure, and vertical, anterior and mediolateral force components were recorded with the Parotec system and Kisler force platform. To assess fatigue, the participants performed treadmill running for twenty-five minutes twice, each time wearing a different shoe size. Surface electromyography was used to confirm localized muscle fatigue using power spectral analysis of four muscles (tibialis anterior, gastrocnemius medialis, rectus femoris, and biceps femoris). The results were as follows: 1) In walking conditions, there was a significantly higher peak pressure in the 10 mm greater than proper shoe size insole sensor 1, 2, 14, and 18 (p<.05). 2) In running conditions, there was a significantly higher peak pressure in the 10 mm greater than proper shoe size insole sensor 5, 14, and 15 (p<.05). 3) In walking conditions, there was a significantly higher first maximal vertical GRF in the 10 mm greater than proper shoe size (p<.05). 4) In running conditions, no GRF components were significantly different between each shoe size condition (p>.05). 5) Muscle fatigue indexes of the tibialis anterior and rectus femoris were significantly increased in the 10 mm greater than proper shoe size condition. These results indicate that wearing shoes that are too large could further exacerbate the problems of increased foot pressure, vertical GRF, and muscle fatigue.

  • PDF

Development of Tethered-Balloon Package System for Vertical Distribution Measurement of Atmospheric Aerosols (Tethered-Balloon Package System 개발 및 대기 에어로졸의 연직 분포 측정)

  • Eun, Hee Ram;Lee, Hong Ku;Lee, Yang Woo;Ahn, Kang-Ho
    • Particle and aerosol research
    • /
    • v.9 no.4
    • /
    • pp.253-260
    • /
    • 2013
  • For a vertical atmospheric aerosol distribution measurement, a very compact and light particle sampling package is developed. This package includes a compact optical particle counter (Hy-OPC), a light and small condensation particle counter (Hy-CPC), sensors (GPS, wind velocity, temperature, humidity), and a communication and system control board. This package is attached to He balloon and the altitude is controlled by a winch. Using this system the vertical particle size distribution was measured. The test results showed that the ground base atmospheric particle measurement result may be a lot different from that high above the ground.

Analysis for the Grounding Impedance of Vertical Grounding Electrodes using the Distributed Parameter Circuit Model (분포정수회로모델을 이용한 수직 접지전극의 접지임피던스의 분석)

  • Lee, Bok-Hee;Kim, Jong-Ho;Choi, Jong-Hyuk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.6
    • /
    • pp.1103-1108
    • /
    • 2010
  • A grounding electrode has the transient grounding impedance characteristics against lightning surges. So the performance of grounding electrodes should be evaluated as a grounding impedance as well as the ground resistance. The frequency-dependent grounding impedance is varied with the shape and size of grounding electrode and is divided into both inductive and capacitive behaviors. This paper presents a theoretical analysis for the grounding impedance determined by the size of grounding electrode using the distributed parameter circuit model. EMTP and Matlab programs were used in calculating the frequency-dependent grounding impedances of vertical grounding electrodes. It was found that the frequency-dependent grounding characteristics of vertical grounding electrodes are characterized by the distributed parameters which are changed in the dimension of grounding electrodes.

An Experiment on Thermosyphon Boiling in Uniformly Heated Vertical Tube and Asymmetrically Heated Vertical Channel

  • Kwak, Ho-Young;Jeon, Jin-Seok;Na, Jung-Hee;Park, Hong-Chul
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.98-107
    • /
    • 2001
  • Continuing efforts to achieve increased circuit performance in electronic package have resulted in higher power density at chip and module level. As a result, the thermal management of electronic package has been important in maintaining or improving the reliability of the component. An experimental investigation of thermosyphonic boiling in vertical tube and channel made by two parallel rectangular plates was carried out in this study for possible application of the direct immersion cooling. Fluorinert FC-72 as a working fluid was used in this experiment. Asymmetric heated channel of open periphery with gap size of 1, 2, 4 and 26mm and uniformly heated vertical tubes with diameter of 9, 15 and 20mm were boiled at saturated condition. The boiling curves from tested surfaces exhibited the boiling hysteresis. It was also found that the gap size is not a significant parameter for the thermosyphonic boiling heat transfer with this Fluorinert. Rather pool boiling characteristics appeared for larger gap size and tube diameter. The heat transfer coefficients measured were also compared with the calculation results by Chens correlation.

  • PDF