• 제목/요약/키워드: vertical shear force

검색결과 181건 처리시간 0.022초

Full-scale tests and analytical model of the Teflon-based lead rubber isolation bearings

  • Wang, Lu;Oua, Jin;Liu, Weiqing;Wang, Shuguang
    • Structural Engineering and Mechanics
    • /
    • 제48권6호
    • /
    • pp.809-822
    • /
    • 2013
  • Base isolation is widely used in seismic resisting buildings due to its low construction cost, high reliability, mature theory and convenient usage. However, it is difficult to design the isolation layer in high-rise buildings using the available bearings because high-rise buildings are characterized with long period, low horizontal stiffness, and complex re-distribution of the internal forces under earthquake loads etc. In this paper, a simple and innovative isolation bearing, named Teflon-based lead rubber isolation bearing, is developed to address the mentioned problems. The Teflon-based lead rubber isolation bearing consists of friction material and lead rubber isolation bearing. Hence, it integrates advantages of friction bearings and lead rubber isolation bearings so that improves the stability of base isolation system. An experimental study was conducted to validate the effectiveness of this new bearing. The effects of vertical loading, displacement amplitude and loading frequency on the force-displacement relationship and energy dissipation capacity of the Teflon-based lead rubber isolation bearing were studied. An analytical model was also proposed to predict the force-displacement relationship of the new bearing. Comparison of analytical and experimental results showed that the analytical model can accurately predict the force-displacement relationship and elastic shear deflection of the Teflon-based lead rubber isolation bearings.

합성형 교량에서 전단연결재에 대한 정적실험 및 강도식의 제안 (Static Test and Suggestion of Shear Strength Equation on Shear Studs in Composite Bridge)

  • 이성태
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권2호
    • /
    • pp.43-50
    • /
    • 2018
  • 본 연구에서는 강주형과 바닥판의 합성에 사용되는 전단연결재에 대한 연구를 위해 세계 각국에서 사용되는 설계기준과 연구사례를 분석하고 교량 바닥판에 작용하는 각종 수직하중으로 인해 강주형과 콘크리트 슬래브의 접촉면에 발생하는 수평방향의 전단력을 전달하는 이 연결재를 설치한 밀어내기 시험체에 대하여 전단실험을 수행하였으며, 이 시험을 통하여 철근 대신 FRP 철근이 배치된 Steel strap 바닥판의 전단열재 평가식을 제안하였다. 본 연구에서의 제안식은 도로교설계기준의 전단연결재 허용강도 대비 약 3배의 안전율을 가지고 있으며, 기존의 DIN 기준과 Viest 평가식과 비교하면 5%정도의 오차로 유사한 결과를 보여주었다.

A simplified model proposal for non-linear analysis of buildings

  • Abdul Rahim Halimi;Kanat Burak Bozdogan
    • Earthquakes and Structures
    • /
    • 제24권5호
    • /
    • pp.353-364
    • /
    • 2023
  • In this study, a method has been proposed for the static and dynamic nonlinear analysis of multi-storey buildings, which takes into account the contribution of axial deformations in vertical load-bearing elements, which are especially important in tall and narrow structures. Shear deformations on the shear walls were also taken into account in the study. The presented method takes into account the effects that are not considered in the fishbone and flexural-shear beam models developed in the literature. In the Fishbone model, only frame systems are modeled. In the flexural shear beam model developed for shear wall systems, shear deformations and axial deformations in the walls are neglected. Unlike the literature, with the model proposed in this study, both shear deformations in the walls and axial deformations in the columns and walls are taken into account. In the proposed model, multi-storey building is represented as a sandwich beam consisting of Timoshenko beams pieced together with a double-hinged beam. At each storey, the total moment capacities of the frame beams and the coupled beams in the coupled shear walls are represented as the equivalent shear capacity. On the other hand, The sums of individual columns and walls moment at the relevant floor level are represented as equivalent moment capacity at that floor level. At the end of the study, examples were solved to show the suitability of the proposed method in this study. The SAP2000 program is employed in analyses. In a conclusion, it is observed that among the solved examples, the proposed sandwich beam model gives good results. As can be seen from these results, it is seen that the presented method, especially in terms of base shear force, gives very close results to the detailed finite element method.

Elastic Wave Propagation in Monoclinic System Due to Transient Line Load

  • Kim, Yong-Yun
    • The Journal of the Acoustical Society of Korea
    • /
    • 제17권2E호
    • /
    • pp.53-58
    • /
    • 1998
  • In this paper, we study the response of several anisotropic systems to buried transient line loads. The problem is mathematically formulated based on the equations of motion in the constitutive relations. The load is in form of a normal stress acting with arbitrary axis on the plane of monoclinic symmetry. Plane wave equation is coupled with vertical shear wave, longitudinal wave and horizontal shear wave. We first considered the equation of motion in reference coordinate system, where the line load is coincident with symmetry axis of the orthotrioic material. Then the equation of motion is transformed with respect to general coordiante system with azimuthal angle by using transformation tensor. The load is first described as a body force in the equations of the motion for the infinite media and then it is mathematically characterized. Subsequently the results for semi-infinite spaces is also obtained by using superposition of the infinite medium solution together with a scattered solution from the free surface. Consequently explicit solutions for the displacements are obtained by using Cargniard-DeHoop contour. Numerical results which are drawn from concrete examples of orthotropic material belonging to monoclinic symmetry are demonstrated.

  • PDF

초듀랄류민(A2024-T3)의 절삭거동에 관한 연구 (The Study on the Cutting Behavior of Super Duralumin(A2024-T3))

  • 전태옥;박흥식;예규현
    • 한국정밀공학회지
    • /
    • 제9권4호
    • /
    • pp.147-153
    • /
    • 1992
  • This study was undertaken to investigate the cutting behaviour of super duralumin (A2024-T3) with sintered carbide tool(P20). The cutting test was carried out under different conditions such as cutting speed, cutting depth and rake angle, etc. The specific cutting force Kc and Kt of vertical and radial forces decreases as cutting speed increases, especially the decrease rate of Kt becomes larger than of Kc as cutting speed increases. Kc and Kt in small cutting depth are much affected by work-hardening of surface layer. The chip width and shear angle become layer as cutting depth increases, especially chip width at feed of 0.1mm almost approaches cutting width. Relation between the friction coefficient of chip side and tool rake angle side can make the modelization studying the built-up edge size. The shear angle model equation of super duralumin generally agree with theory of Ernst-Merchant.

  • PDF

Experimental study of a modeled building frame supported by pile groups embedded in cohesionless soil

  • Ravi Kumar Reddy, C.;Gunneswara Rao, T.D.
    • Interaction and multiscale mechanics
    • /
    • 제4권4호
    • /
    • pp.321-336
    • /
    • 2011
  • This paper presents the results of static vertical load tests carried out on a model building frame supported by pile groups embedded in cohesionless soil (sand). The effect of soil interaction on displacements and rotation at the column base and also the shears and bending moments in the columns of the building frame were investigated. The experimental results have been compared with those obtained from the finite element analysis and conventional method of analysis. Soil nonlinearity in the lateral direction is characterized by the p-y curves and in the axial direction by nonlinear vertical springs along the length of the piles (${\tau}-z$ curves) at their tips (Q-z curves). The results reveal that the conventional method gives the shear force in the column by about 40-60%, the bending moment at the column top about 20-30% and at the column base about 75-100% more than those from the experimental results. The response of the frame from the experimental results is in good agreement with that obtained by the nonlinear finite element analysis.

전단철근이 배치된 프리캐스트 프리스트레스트 중공슬래브의 구조성능 평가 (Evaluation of Structural Performance of Precast Prestressed Hollow-Core Slabs with Shear Reinforcement)

  • 김상윤;김선훈;이득행;한선진;김길희
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제27권1호
    • /
    • pp.71-77
    • /
    • 2023
  • 이 연구에서는 높이가 400 mm인 중공슬래브(Hollow-Core Slab, 이하 HCS)의 구조성능을 평가하기 위한 실대형 실험을 수행하였으며, 기존의 압출성형방식이 아닌 단일몰드방식을 적용하여 총 4개의 HCS를 제작하였다. 실험의 주요 변수는 토핑콘크리트의 유무, 전단보강근의 배치 유무 및 위치로 설정하였으며, 실험체들의 균열패턴 및 하중-변위 응답을 상세히 분석하였다. 실험결과 전단철근이 배치된 HCS 실험체들은 휨강도를 달성하였고, 이후에 최종적인 파괴는 사인장균열에 의하여 지배되었으며, HCS 유닛 웨브 내에 전단철근이 배치되지 않은 실험체들의 경우 설계기준을 통해 산정된 공칭휨강도를 발현하지 못하였다. 전단철근을 HCS 유닛에 배근 할 경우에는 전단강도가 약 8~23% 증가하는 것으로 나타났으며, HCS의 중공을 철근콘크리트로 보강하는 방법보다 전단성능 향상에 더 효과적인 것으로 나타났다.

Analysis of Dynamic Response Characteristics for 5 MW Jacket-type Fixed Offshore Wind Turbine

  • Kim, Jaewook;Heo, Sanghwan;Koo, WeonCheol
    • 한국해양공학회지
    • /
    • 제35권5호
    • /
    • pp.347-359
    • /
    • 2021
  • This study aims to evaluate the dynamic responses of the jacket-type offshore wind turbine using FAST software (Fatigue, Aerodynamics, Structures, and Turbulence). A systematic series of simulation cases of a 5 MW jacket-type offshore wind turbine, including wind-only, wave-only, wind & wave load cases are conducted. The dynamic responses of the wind turbine structure are obtained, including the structure displacement, rotor speed, thrust force, nacelle acceleration, bending moment at the tower bottom, and shear force on the jacket leg. The calculated time-domain results are transformed to frequency domain results using FFT and the environmental load with more impact on each dynamic response is identified. It is confirmed that the dynamic displacements of the wind turbine are dominant in the wave frequency under the incident wave alone condition, and the rotor thrust, nacelle acceleration, and bending moment at the bottom of the tower exhibit high responses in the natural frequency band of the wind turbine. In the wind only condition, all responses except the vertical displacement of the wind turbine are dominant at three times the rotor rotation frequency (considering the number of blades) generated by the wind. In a combined external force with wind and waves, it was observed that the horizontal displacement is dominant by the wind load. Additionally, the bending moment on the tower base is highly affected by the wind. The shear force of the jacket leg is basically influenced by the wave loads, but it can be affected by both the wind and wave loads especially under the turbulent wind and irregular wave conditions.

Static behaviour of lying multi-stud connectors in cable-pylon anchorage zone

  • Lin, Zhaofei;Liu, Yuqing;He, Jun
    • Steel and Composite Structures
    • /
    • 제18권6호
    • /
    • pp.1369-1389
    • /
    • 2015
  • In order to investigate the behaviour of lying multi-stud connectors in cable-pylon anchorage zone, twenty-four push-out tests are carried out with different stud numbers and diameters. The effect of concrete block width and tensile force on shear strength is investigated using the developed and verified finite element model. The results show that the shear strength of the lying multi-stud connectors is reduced in comparison with the lying single-stud connector. The reduction increases with the increasing of the number of studs in the vertical direction. The influence of the stud number on the strength reduction of the lying multi-stud connectors is decreased under combined shear and tension loads compared with under pure shear. Yet, due to multi-stud effect, they still can't be ignored. The concrete block width has a non-negligible effect on the shear strength of the lying multi-stud connectors and therefore should be chosen properly when designing push-out specimens. No obvious difference is observed between the strength reductions of the studs with 22 mm and 25 mm diameters. The shear strengths obtained from the tests are compared with those predicted by AASHTO LRFD and Eurocode 4. Eurocode 4 generally gives conservative predictions of the shear strength, while AASHTO LRFD overestimates the shear strength. In addition, the lying multi-stud connectors with the diameters of 22 m and 25 mm both exhibit adequate ductility according to Eurocode 4. An expression of load-slip curve is proposed for the lying multi-stud connectors and shows good agreement with the test results.

트러스 이론을 이용한 철근 콘크리트 전단벽의 비선형 거동해석 (Nonlinear Behavior Analysis of RC Shear Wall Using Truss Theory)

  • 서수연;김정식;최윤철;이리형
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제9권3호
    • /
    • pp.213-220
    • /
    • 2005
  • 최근 전단벽의 변형성능을 증명하기 위한 관심이 성능 설계법을 위한 적당한 자료들을 얻기 위해서 증대되고 있다. 본 연구에서는 전단벽의 변형 성능을 평가할수 있는 방법을 제시하고자 한다. 전단벽의 변위는 전단과 휨 변형의 조합된 형태로 표현될 수 있다. 수정 변환각 트러스 모델과 휨이론을 이용하여 전단과 휨변형을 산정하였으며, 또한 축력과 많은 수직 및 수평보강근의 영향을 고려할 수 있는 트러스 모델을 구축하였다. 본 연구에서 제안한 방법의 정확성을 평가하기 위하여 기 수행된 7개의 실험결과를 해석하고 실험결과와 해석결과를 비교하였다. 비교결과, 본 연구에서 제안한 방법을 사용함으로써 전단벽의 변형성능을 적절히 예측할 수 있는 것으로 나타났다. 그러나 플랜지벽이 있는 경우에는 강도와 강성의 측면에서 플랜지벽의 영향을 과대평가하며 변위성능의 측면에서는 과소평가하는 것으로 나타났다.