• Title/Summary/Keyword: vertical drop

Search Result 218, Processing Time 0.025 seconds

Experimental study on vibration serviceability of cold-formed thin-walled steel floor

  • Bin Chen;Liang Cao;Faming Lu;Y. Frank Chen
    • Steel and Composite Structures
    • /
    • v.46 no.4
    • /
    • pp.577-589
    • /
    • 2023
  • In this study, on-site testing was carried out to investigate the vibration performance of a cold-formed thin-walled steel floor system. Ambient vibration, walking excitation (single and double persons), and impulsive excitation (heel-drop and jumping) were considered to capture the primary vibration parameters (natural frequencies, damping ratios, and mode shapes) and vertical acceleration response. Meanwhile, to discuss the influence of cement fiberboard on structural vibration, the primary vibration parameters were compared between the systems with and without the installation of cement fiberboard. Based on the experimental analysis, the cold-formed thin-walled steel floor possesses high frequency (> 10 Hz) and damping (> 2%); the installed cement fiberboard mainly increases the mass of floor system without effectively increasing the floor stiffness and may reduce the effects of primary vibration parameters on acceleration response; and the human-structure interaction should be considered when analyzing the vibration serviceability. The comparison of the experimental results with those in the AISC Design Guide indicates that the cold-formed thin-walled steel floor exhibits acceptable vibration serviceability. A crest factor 𝛽rp (ratio of peak to root-mean-square accelerations) is proposed to determine the root-mean-square acceleration for convenience.

Biomechanical Analysis of Lower Extremity Joints According to Landing Types during Maximum Vertical Jump after Jump Landing in Youth Sports Athletes (유소년 스포츠 선수들의 점프착지 후 수직점프 동작 시 착지 유형에 따른 하지관절의 운동역학적 분석)

  • Jiho Park;Joo Nyeon Kim;Sukhoon Yoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.33 no.3
    • /
    • pp.110-117
    • /
    • 2023
  • Objective: The purpose of this study was to find out kinematic and kinetic differences the lower extremity joint according to the landing type during vertical jump movement after jump landing, and to present an efficient landing method to reduce the incidence of injury in youth players. Method: Total of 24 Youth players under Korean Sport and Olympic Committee, who used either heel contact landing (HCG) or toe contact landing (TCG) participated in this study (HCG (12): CG height: 168.7 ± 9.7 cm, weight: 60.9 ± 11.6 kg, age: 14.1 ± 0.9 yrs., career: 4.3 ± 2.9 yrs., TCG height: 174.8 ± 4.9 cm, weight: 66.9 ± 9.9 kg, age 13.9 ± 0.8 yrs., career: 4.7 ± 2.0 yrs.). Participants were asked to perform jump landing consecutively followed by vertical jump. A 3-dimensional motion analysis with 19 infrared cameras and 2 force plates was performed in this study. To find out the significance between two landing styles independent t-test was performed and significance level was set at .05. Results: HCG showed a significantly higher dorsi flexion, extension and flexion angle at ankle, knee and hip joints, respectively compared with those of TCG (p<.05). Also, HCG revealed reduced RoM at ankle joint while it showed increased RoM at knee joint compared to TCG (p<.05). In addition, HGC showed greater peak force, a loading rate, and impulse than those of TCG (p<.05). Finally, greater planta flexion moment was revealed in TCG compared to HCG at ankle joint. For the knee joint HCG showed extension and flexion moment in E1 and E2, respectively, while TCG showed opposite results. Conclusion: Compared to toe contact landing, the heel contact landing is not expected to have an advantage in terms of absorbing and dispersing the impact of contact with the ground to the joint. If these movements continuously used, performance may deteriorate, including injuries, so it is believed that education on safe landing methods is needed for young athletes whose musculoskeletal growth is not fully mature.

Water droplet generation technique for 3D water drop sculptures (3차원 물방울 조각 생성장치의 구현을 위한 물방울 생성기법)

  • Lin, Long-Chun;Park, Yeon-yong;Jung, Moon Ryul
    • Journal of the Korea Computer Graphics Society
    • /
    • v.25 no.3
    • /
    • pp.143-152
    • /
    • 2019
  • This paper presents two new techniques for solving the two problems of the water curtain: 'shape distortion' caused by gravity and 'resolution degradation' caused by fine satellite droplets around the shape. In the first method, when the user converts a three-dimensional model to a vertical sequence of slices, the slices are evenly spaced. The method is to adjust the time points at which the equi-distance slices are created by the nozzle array. In this method, even if the velocity of a water drop increases with time by gravity, the water drop slices maintain the equal interval at the moment of forming the whole shape, thereby preventing distortion. The second method is called the minimum time interval technique. The minimum time interval is the time between the open command of a nozzle and the next open command of the nozzle, so that consecutive water drops are clearly created without satellite drops. When the user converts a three-dimensional model to a sequence of slices, the slices are defined as close as possible, not evenly spaced, considering the minimum time interval of consecutive drops. The slices are arranged in short intervals in the top area of the shape, and the slices are arranged in long intervals in the bottom area of the shape. The minimum time interval is pre-determined by an experiment, and consists of the time from the open command of the nozzle to the time at which the nozzle is fully open, and the time in which the fully open state is maintained, and the time from the close command to the time at which the nozzle is fully closed. The second method produces water drop sculptures with higher resolution than does the first method.

CPFD Simulation of Bubble Flow in a Bubbling Fluidized Bed with Shroud Nozzle Distributor and Vertical Internal (CPFD 시뮬레이션을 통한 Shroud 노즐 및 수직 구조물이 설치된 기포 유동층 반응기 내에서의 기포 흐름 해석)

  • Lim, Jong Hun;Bae, Keon;Shin, Jea Ho;Lee, Dong Ho;Han, Joo Hee;Lee, Dong Hyun
    • Korean Chemical Engineering Research
    • /
    • v.54 no.5
    • /
    • pp.678-686
    • /
    • 2016
  • The effect of internal and shroud nozzle distributor to bubbling fluidized beds which has the size of $0.3m-ID{\times}2.4m-high$ column was modeled by CPFD (Computational Particle-Fluid Dynamics). Metal-grade silicon particles (MG-Si) were used as bed materials which have $d_p=149{\mu}m$, ${\rho}_p=2,325kg/m^3$ and $U_{mf}=0.02m/s$. Total bed inventory and static bed height were 75 kg and 0.8 m, respectively. Effect of vertical internal on the bubble rising velocity was investigated. Bubbles were split by internal when the axial position of the internal from the distributor, z = 0.45 m. Bed pressure drop and axial solid holdup were not affected by internal. However, in the case that axial distance of internal from distributor was too close to jet penetration length, bubbles were not separated and bypassed internal, and faster than without internal or z = 0.45 m.

Modification of Balancing Piston for Trimming of Impeller Diameter for Maintaining Axial-Thrust Balance in Low-Specific-Speed Multistage Centrifugal Pumps (저비속도 원심 회전차 외경가공에 따른 축추력 불균형을 감쇄시키기 위한 평형 피스톤 수정방안에 관한 고찰)

  • Yoo, Il-Su;Park, Moo-Ryong;Yoon, Eui-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.9
    • /
    • pp.875-882
    • /
    • 2011
  • In the present study, the imbalance in the axial-thrust and variation in the volumetric efficiency that occurred during the trimming of impeller diameter were investigated. The present study was focused on low-specific-speed multistage centrifugal pumps with a balancing piston as the balancing mechanism. The effects of impeller trimming on the axial-thrust balance in multistage pumps with horizontal and vertical axes were compared. The results showed that impeller trimming resulted in an additional axial-thrust acting in direction of pump inlet. The axial-thrust imbalance due to impeller trimming was more severe in the vertical-axis pumps than in the horizontal-axis pumps. The rate of increase in the diameter of the balancing piston, which was proportional to the rate of impeller trimming, was evaluated to maintain the axial-thrust balance. Furthermore, a simultaneous increase in the piston length and piston diameter was more effective for reducing the axial-thrust imbalance along with the volumetric efficiency drop.

The Installation Effect and Optimal Pipe Sizes of an Anti-Wind Net by Computational Analysis (전산 해석에 의한 파풍망의 설치 효과와 최적 파이프 규격)

  • Yum, Sung-Hyun;Kwon, Ki-Jeong;Sung, Si-Heung;Choi, Young-Don
    • Journal of Biosystems Engineering
    • /
    • v.32 no.6
    • /
    • pp.430-439
    • /
    • 2007
  • This study was carried out to(1) visualize the installation effect of an anti-wind net; (2) evaluate structural stability of typical anti-wind nets in Jeju; and (3) present the optimal specification of pipes in an anti-wind net for maximum instant wind velocities of 40 m/s and 45 m/s. The analyses were done for anti-wind nets with a mesh of 4 mm and a height of 3 m by using CFX and ANSYS. The results showed that the wind went down due to flow resistance when passing through an. anti-wind net. The anti-wind net with the supporting pipe being installed every two main columns was certainly unstable because the main column not sustained by the supporting pipe became cantilever. With regard to the position of a fixing point of the supporting pipe, von Mises stress on pipes was certainly increased as vertical positions of the supporting pipe were changed to be too lower or higher than an adequate position but there was little difference according to horizontal positions. The adequate vertical position was $2{\sim}2.5\;m$ high from the ground. For a maximum instant wind velocity of 40 m/s, the optimal specification of pipes was a main column of ${\varphi}48.1{\times}2.1$ t@2,000, cross beams(bottom and top) of ${\varphi}26.7{\times}1.9\;t$, cross beams(center) of ${\varphi}33.5{\times}2.1$ t/2ea and a supporting pipe of ${\varphi}31.8{\times}1.5$ t@2,000. In case of a maximum instant wind velocity of 45 m/s, the optimal specification of pipes with structural stability was a main column of ${\varphi}48.6{\times}3.25$ t@2,000, cross beams(bottom and top) of ${\varphi}26.7{\times}1.9\;t$, cross beams(center) of ${\varphi}48.1{\times}2.1$ t/2ea and a supporting pipe of ${\varphi}31.8{\times}1.5$ t@2,000.

A Suggestion for the Size-designation for Obese Middle-aged Women's Swimsuits (중년 비만여성을 위한 수영복 치수규격 제안)

  • Lim, Ji-Yung
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.36 no.4
    • /
    • pp.391-399
    • /
    • 2012
  • This study helps out-size consumers purchase swimsuits and improves fitness by classifying the torso of middle-aged obese women; in addition, it creates a size system based on each size interval for obese types. The criteria for subjects in this study were over 25kg/$m^2$ of the BMI, over 85cm of waist, and over 95cm of bust; 199 females were surveyed. Three torso types were categorized by a cluster analysis into X type (the vertical size of hip girth was the biggest of the three and the waist was slender), H-O type (larger than other groups in bust girth with more fat above the circumstance of the abdomen), and Y type (the upper half of body development type and lower body fatness were between those of type X and those of type H-O). As a consequence of size system establishment according to obesity types, the basic body sizes and reference body sizes were different according to types even in commonly-appeared size names at sections of respective types. The research findings show the necessity to understand obesity types according to bust girth and hip girth sizes that represent basic sizes as well as to design patterns in consideration of the characteristics of obese body shapes when swimsuits are designed for obese groups. The findings can be used as basic data to decide the desirable output of production according to respective body types.

Characterization and Comparison of Doping Concentration in Field Ring Area for Commercial Vertical MOSFET on 8" Si Wafer (8인치 Si Power MOSFET Field Ring 영역의 도핑농도 변화에 따른 전기적 특성 비교에 관한 연구)

  • Kim, Gwon Je;Kang, Ye Hwan;Kwon, Young-Soo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.4
    • /
    • pp.271-274
    • /
    • 2013
  • Power Metal Oxide Semiconductor Field Effect Transistor's (MOSFETs) are well known for superior switching speed, and they require very little gate drive power because of the insulated gate. In these respects, power MOSFETs approach the characteristics of an "ideal switch". The main drawback is on-resistance RDS(on) and its strong positive temperature coefficient. While this process has been driven by market place competition with operating parameters determined by products, manufacturing technology innovations that have not necessarily followed such a consistent path have enabled it. This treatise briefly examines metal oxide semiconductor (MOS) device characteristics and elucidates important future issues which semiconductor technologists face as they attempt to continue the rate of progress to the identified terminus of the technology shrink path in about 2020. We could find at the electrical property as variation p base dose. Ultimately, its ON state voltage drop was enhanced also shrink chip size. To obtain an optimized parameter and design, we have simulated over 500 V Field ring using 8 Field rings. Field ring width was $3{\mu}m$ and P base dose was $1e15cm^2$. Also the numerical multiple $2.52cm^2$ was obtained which indicates the doping limit of the original device. We have simulated diffusion condition was split from $1,150^{\circ}C$ to $1,200^{\circ}C$. And then $1,150^{\circ}C$ diffusion time was best condition for break down voltage.

Ankle Taping and Vertical Drop Landing (발목관절의 테이핑과 수직 착지동작)

  • Yi, Chung-Hwi
    • Physical Therapy Korea
    • /
    • v.8 no.4
    • /
    • pp.17-29
    • /
    • 2001
  • 발목에 대한 유착성 테이핑의 적용은 물리치료 분야와 운동 트레이닝 분야에서의 일반적인 치료 접근 방법이라 할 수 있다. 즉 발목 염좌 같은 손상을 예방하기 위한 방법과 재활의 부가적인 치료 형태로 이용될 수 있는 것이다. 본 연구는 발목의 테이핑과 트레드밀에서의 30분간 보행이 수직 착지 동작 동안 하지의 운동 역학적 요소들에 어떠한 영향을 주는지 알아보기 위해 시행되었다. 14명의 신체 건강한 대상자들 (남:10, 여:4)이 본 연구에 참여하였다. 한발로 서있는 동안 40 cm의 높이로 뛰게 하였다. 가자미근, 전경골근, 안쪽넓은근, 넙다리 두갈래근에 근전도 전극이 부착되었다. 테이핑된 신체 부위로 착지하는 동안 근전도와 힘판(force plate) 자료가 500 Hz의 주파수로 수집되었다. 대상자들의 우세쪽 하지 발목에 테이핑을 하였고, 대상자는 한발로 뛰어 내리는 동작을 반복하였다. 트레드밀에서 30분 동안 발목에 테이핑을 한 채로 보행하였고 이후 한발로 뛰어 내리는 동작을 반복하여 수행하였다. 테이핑을 적용한 상태와 테이핑한 채로 30분 동안 트레드밀에서 걷기 운동을 한 조건에서 수직 지면 반발력의 통계학적으로 유의미한 증가가 있었다. 착지 동안에 네 가지 상황에서의 최대 내측 가속도의 유의한 차이가 있었고, 그 차이는 테이핑 전과 테이핑을 한 채로의 운동 조건에서 유의한 차이가 있었다. 테이핑한 상태에서 가자미근은 접촉되는 착지 순간부터 최대 수직 지면 반발력이 나타나는 동안의 평균 근전도의 수치에 있어서 유의한 감소가 있었다. 반면에 다른 근육들에서는 아무런 변화를 보이지 않았다. 비록 발목 테이핑이 발목 손상의 위험을 줄이는데 효과적이라고 일반적으로 인식되고 있으나 이번 실험의 결과는 30분 동안의 트레드밀에서의 보행 후 테이핑은 발목의 움직임을 제한하는 효과는 있지만 한편으로는 가자미근의 활동을 감소시키는 것을 보여주었다. 따라서 이 연구의 결과는 테이핑을 하면 점프와 착지로 이어지는 동작 중에 발목관절 손상 위험을 증가시킬 가능성이 있음을 보여주었다.

  • PDF

A Performance Analysis and Experiments on Plastic Film/Paper Humidifying Elements Consisting of Horizontal Air Channels and Vertical Water Channels (수평 공기 채널과 수직 물 채널로 구성된 플라스틱 필름/종이 가습 소자의 성능)

  • Kim, Nae-Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.1
    • /
    • pp.55-63
    • /
    • 2016
  • New materials and shapes for a humidifying element were developed which outperformed the widely used crisscross glass wool Glasdek media design. The new material consists of 50% cellulose and 50% PET. The parallel channel configuration was devised to reduce excessive pressure loss caused by the reduced height (from 7.0 mm to 5.0 mm) of the crisscross configuration. For the same crisscross configuration, the humidification efficiency of the cellulose/PET element was 26% higher than that of the glass wool element. For the same cellulose/PET material, humidification efficiency of the parallel channel configuration was 14% higher than that of the crisscross configuration. As for the pressure drops, the cellulose/PET element was 2-52% higher than those of the glass wool element. For the same cellulose/PET material, the pressure drop of the parallel channel configuration was 14% higher than that of the crisscross configuration. Data were compared against the predictions from existing correlations and those by the proposed model.