• Title/Summary/Keyword: vertical columns

Search Result 255, Processing Time 0.031 seconds

Study on the Heat Transfer Characteristics of Immerged and Falling Flows on Helical Tubes (헬리컬관외 침전 및 적하 열전달 특성에 관한 연구)

  • 황승기;윤상국;김동혁;이승갑
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.4
    • /
    • pp.225-232
    • /
    • 2001
  • An experimental study is carried out to investigate the characteristics of heat transfer of outside helical tubes. The main heat exchanger consists of twelve curved columns with each 300mm diameter and the total length of 1.2m copper tube having an outer diameter of 19.05mm with 1.5mm thickness. Water flows down the outside of helical tube, where flow patterns are the vertical film falling flow, immerged flow, and mixed-flow which is the combination of film falling flow and immerged flow. Refrigerant 11 flow the inside of the tube countercurrently. The experimental range of inside flow rate is 1.7~3.2$\ell$/min and outside flow rate is 21-33$\ell$/min. The results are presented as Nusselt number with corresponding Reynolds number for variety of outside and inside flow rates. The heat transfer rates of the mixed flow are 8 to 56% higher than those of film falling flow or immerged flow only. Interpretation of the results is given on the basis of physical reasoning and the correlation equations.

  • PDF

Studies on Variable Liquid-Column Oscillator for High Efficiency Floating Wave Energy Conversion System (가변 수주진동장치를 이용한 고효율 파력발전에 관한 연구)

  • Yang, Dong-Soon;Cho, Byung-Hak
    • Journal of Ocean Engineering and Technology
    • /
    • v.23 no.5
    • /
    • pp.15-24
    • /
    • 2009
  • The results of a simulation study of variable liquid column oscillations in U-tanks with a novel control scheme are presented. The configuration under investigation is analogous to that of the tuned liquid-column damper used to suppress oscillatory motion in large structures like tall buildings and cargo ships. However, by virtue of an adequate controller, the response of amplitude of the U-tanks becomes larger in a desired frequency range. The motion of wave energy conversion system equipped with a variable liquid column oscillator is described by a series of nonlinear differential equations. The equations describe the motion of body under ocean wave excitation, and the motion of liquid with an air-spring effect caused by the compression and expansion of air in vertical liquid columns and air chambers. It is shown that the effect of the air-spring has a vital role to maintain the natural frequency of oscillation in the system to synchronize with the frequency of the ocean wave, thus the system provides the most effective mode for energy extraction from the ocean.

Study on Fire Resistance of Beams filled with Concrete at Web Through Temperature Analysis and Load-bearing Fire Tests (온도해석과 재하가열시험에 의한 콘크리트 충전 보부재의 내화성능평가에 관한 연구)

  • Kwon, In-Kyu
    • Fire Science and Engineering
    • /
    • v.24 no.6
    • /
    • pp.82-88
    • /
    • 2010
  • Major structural elements such as columns and beams are designed to withstand the vertical and horizontal loads. Futhermore, when the structural elements were engulfed with fire the structural stability should be stand without failure. The beams have been developed in aspects of structural stability but an evaluation of fire performance was not done. So the data of fire resistance performance of beams filled with concrete at web on H-section is not known. The purpose of this paper is to analyse the correlation between temperature analysis and fire test with the beams and to show the fire resistance performance with two methods.

Efficient Analysis of Shear Wall Strustures with Pilotis considering the in-plane stiffness of the floor slabs (바닥슬래브의 면내강성을 고려한 필로티 구조물의 효율적인 거동분석)

  • Kim Hyun-Su;Kim Hye-Sook;Kim Hyun-Jung;Lee Dong-Guen
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.865-872
    • /
    • 2006
  • Recently, many apartment buildings in the shear wall system often has pilotis in the lower story to meet the architectural needs. If the lateral force resisting system consists of shear walls supported by columns and beams. the discontinuity at the lowest level with pilotis results in the vertical irregularity with strength and stiffness. So, there are needs to be considered tile analysis and design about column and beam bellow shear walls and the behavior and stress condition of structure by stiffness change being generated at shear walls. The purpose of this paper is to investigate the behavior of shear wall structures with pilotis using the floors modeled as rigid diaphragm or semi rigid diaphragm. Through analyses, after estimating values of the story drift, natural period, stress condition of shear walls and the forces of column, we inferred how the behavior of shear wall structures with pilotis was influenced by the floor stiffness.

  • PDF

Evaluation of vierendeel peripheral frame as supporting structural element for prevention of progressive collapse

  • Khaloo, Alireza;Omidi, Hossein
    • Steel and Composite Structures
    • /
    • v.26 no.5
    • /
    • pp.549-556
    • /
    • 2018
  • Progressive building collapse occurs when failure of a structural component leads to the failure and collapse of surrounding members, possibly promoting additional failure. Global system collapse will occur if the damaged system is unable to reach a new static equilibrium configuration. The most common type of primary failure which led to the progressive collapse phenomenon, is the sudden removal of a column by various factors. In this study, a method is proposed to prevent progressive collapse phenomena in structures subjected to removal of a single column. A vierendeel peripheral frame at roof level is used to redistribute the removed column's load on other columns of the structure. For analysis, quasi-static approach is used which considers various load combinations. This method, while economically affordable is easily applicable (also for new structures as well as for existing structures and without causing damage to their architectural requirements). Special emphasis is focused on the evolution of vertical displacements of column removal point. Even though additional stresses and displacements are experienced by removal of a structural load bearing column, the proposed method considerably reduces the displacement at the mentioned point and prevents the collapse of the structural frame.

Aerosol Optical Thickness of the Yellow Sand from Direct Solar Radiation at Anmyon Island during the Spring of 1998 (안면도에서1998년 봄철에 관측된 황사의 광학적 특징)

  • Shin, Do-Shick;Kim, San;Kim, Jeong-Sik;Cha, Ju-Wan
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.6
    • /
    • pp.739-746
    • /
    • 1999
  • The spectral aerosol optical thickness of vertical air columns were measured by a ground-based multi-channel sunphotometer at the BAPMoN station(36$^{\circ}$31'N, 126$^{\circ}$19'E) in Anmyon Island, Korea, from 1 March 1998 to 31 May 1998. We used the data of three yellow sand and two clear sky days in order to analyze the temporal variations in aerosol optical thickness at the station. The basic aerosol optical thickness generally represented smaller than 0.3 in a clear sky and the range 0.5 to 1.1 in yellow sand. Especially the aerosol optical thickness represented larger than 0.9 in a heavy yellow sand. It was found that the aerosol optical thickness of yellow sand was highly increased in comparison with the case of a clear sky andparticles larger than 0.5$mu extrm{m}$ were also increased in the spectral distribution of aerosol volume during yellow sand. Consequently the spectral variations in tropospheric aerosol caused by yellow sand were determined by the number concentration of particles larger than 0.5${\mu}{\textrm}{m}$ and the magnitude of yellow sand.

  • PDF

Dynamic Stability of a Cantilevered Vertical Column Subjected to a Subtangential Force and Having a Tip Mass (끝단질량을 갖고 아접선력을 받는 외팔 수직기둥의 동적 안정성)

  • Park, Young-Pil;Ryu, Bong-Jo;Lee, Gyu-Seop;Kim, In-Sung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.2
    • /
    • pp.245-251
    • /
    • 1997
  • The dynamic behavior of elastic columns under the action of the subtangential force is studied in this paper. The subtangential force is the combination of the tip mass dead load and pure follower thrust. In this study, the tip mass is assumed to be a rigid body rather than a point mass. The equations of motion are derived based on the extended Hamilton's principle and the finite element method. Then the equations of motion are trasformed into a dimensionless form, and several parameters are identified. It is found that the critical subtangential force can be changed subtangentially by considering the parameters related to tip mass. It is also shown that the nonconservativeness of the applied force has a significant effect on the type of instability. The influence of the self-weight of the column on the variation of the critical force is also investigated.

Experimental and numerical study on innovative seismic T-Resisting Frame (TRF)

  • Ashtari, Payam;Sedigh, Helia Barzegar;Hamedi, Farzaneh
    • Structural Engineering and Mechanics
    • /
    • v.60 no.2
    • /
    • pp.251-269
    • /
    • 2016
  • In common structural systems, there are some limitations to provide adequate lateral stiffness, high ductility, and architectural openings simultaneously. Consequently, the concept of T-Resisting Frame (TRF) has been introduced to improve the performance of structures. In this study, Configuration of TRF is a Vertical I-shaped Plate Girder (V.P.G) which is placed in the middle of the span and connected to side columns by two Horizontal Plate Girders (H.P.Gs) at each story level. System performance is improved by utilizing rigid connections in link beams (H.P.Gs). Plastic deformation leads to tension field action in H.P.Gs and causes energy dissipation in TRF; therefore, V.P.G. High plastic deformation in web of TRF's members affects the ductility of system. Moreover, in order to prevent shear buckling in web of TRF's members and improve overall performance of the system, appropriate criteria for placement of web stiffeners are presented in this study. In addition, an experimental study is conducted by applying cyclic loading and using finite element models. As a result, hysteresis curves indicate adequate lateral stiffness, stable hysteretic behavior, and high ductility factor of 6.73.

Experimental investigation of flow characteristics around four square-cylinder arrays at subcritical Reynolds numbers

  • Liu, Mingyue;Xiao, Longfei;Yang, Lijun
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.7 no.5
    • /
    • pp.906-919
    • /
    • 2015
  • The Deep Draft Semi-Submersible (DDS) concepts are known for their favourable vertical motion performance. However, the DDS may experience critical Vortex-Induced Motion (VIM) stemming from the fluctuating forces on the columns. In order to investigate the current-induced excitation forces of VIM, an experimental study of flow characteristics around four square-section cylinders in a square configuration is presented. A number of column spacing ratios and array attack angles were considered to investigate the parametric influences. The results comprise flow patterns, drag and lift forces, as well as Strouhal numbers. It is shown that both the drag and lift forces acting on the cylinders are slightly different between the various L/D values, and the fluctuating forces peak at L/D = 4.14. The lift force of downstream cylinders reaches its maximum at around ${\alpha}=15^{\circ}$. Furthermore, the flow around circular-section-cylinder arrays is also discussed in comparison with that of square cylinders.

Raffles City in Hangzhou China -The Engineering of a 'Vertical City' of Vibrant Waves-

  • Wang, Aaron J.
    • International Journal of High-Rise Buildings
    • /
    • v.6 no.1
    • /
    • pp.33-47
    • /
    • 2017
  • This mixed-use Raffles City (RCH) development is located near the Qiantang River in Hangzhou, the capital of Zhejiang province, located southwest of Shanghai, China. The project incorporates retail, offices, housing, and hotel facilities and marks the site of a cultural landscape within the Quianjiang New Town Area. The project is composed of two 250-meter-tall twisting towers with a form of vibrant waves, along with a commercial podium and three stories of basement car parking. It reaches a height of 60 stories, presenting views both to and from the Qiantang River and West Lake areas, with a total floor area of almost 400,000 square meters. A composite moment frame plus concrete core structural system was adopted for the tower structures. Concrete filled steel tubular (CFT) columns together with steel reinforced concrete (SRC) beams form the outer moment frame of the towers' structure. The internal slabs and floor beams are of reinforced concrete. This paper presents the engineering design and construction of this highly complex project. Through comprehensive discussion and careful elaboration, some conclusions are reached, which serve as a reference guide for the design and construction of similar free-form, hybrid, mix-use buildings.