• Title/Summary/Keyword: vertical columns

Search Result 256, Processing Time 0.028 seconds

Influence of loading method and stiffening on the behavior of short and long CFST columns

  • Shaker, Fattouh M.F.;Ghanem, Gouda M.;Deifalla, Ahmed F.;Hussein, Ibrahim S.;Fawzy, Mona M.
    • Steel and Composite Structures
    • /
    • v.44 no.3
    • /
    • pp.295-307
    • /
    • 2022
  • The objective of this research is to study experimentally the behavior of stiffened steel tubes (CFSTs). Considered parameters are stiffening methods by through-bolts or shear connectors with different configurations. In addition, the effect of global (ratio between length to diameter) and local (proportion between diameter to thickness) slenderness ratios are investigated. Load application either applied on steel only or both steel and concrete is studied as well. Case of loading on steel only happens when concrete inside the column shrinks. The purpose of the research is to improve the behavior of CFSTs by load transfer between them and different stiffening methods. A parametric experimental study that incorporates thirty-three specimens is carried out to highlight the impact of those parameters. Different outputs are recorded for every specimen such as load capacities, vertical deflections, longitudinal strains, and hoop strains. Two modes of failure occur, yielding and global buckling. Shear connectors and through-bolts improve the ultimate load by up to 5% for sections loaded at steel with different studied global slenderness and local slenderness equal 63.5. Meanwhile, shear connectors or through bolts increase the ultimate load by up to 6% for global slenderness up to 15.75 for sections loaded on composite with local slenderness equals 63.50. Recommendations for future design code development are outlined.

A simplified model proposal for non-linear analysis of buildings

  • Abdul Rahim Halimi;Kanat Burak Bozdogan
    • Earthquakes and Structures
    • /
    • v.24 no.5
    • /
    • pp.353-364
    • /
    • 2023
  • In this study, a method has been proposed for the static and dynamic nonlinear analysis of multi-storey buildings, which takes into account the contribution of axial deformations in vertical load-bearing elements, which are especially important in tall and narrow structures. Shear deformations on the shear walls were also taken into account in the study. The presented method takes into account the effects that are not considered in the fishbone and flexural-shear beam models developed in the literature. In the Fishbone model, only frame systems are modeled. In the flexural shear beam model developed for shear wall systems, shear deformations and axial deformations in the walls are neglected. Unlike the literature, with the model proposed in this study, both shear deformations in the walls and axial deformations in the columns and walls are taken into account. In the proposed model, multi-storey building is represented as a sandwich beam consisting of Timoshenko beams pieced together with a double-hinged beam. At each storey, the total moment capacities of the frame beams and the coupled beams in the coupled shear walls are represented as the equivalent shear capacity. On the other hand, The sums of individual columns and walls moment at the relevant floor level are represented as equivalent moment capacity at that floor level. At the end of the study, examples were solved to show the suitability of the proposed method in this study. The SAP2000 program is employed in analyses. In a conclusion, it is observed that among the solved examples, the proposed sandwich beam model gives good results. As can be seen from these results, it is seen that the presented method, especially in terms of base shear force, gives very close results to the detailed finite element method.

Experimental Study on Compressive Strength of Concrete Column Retrofitted by Carbon FRP Sheet (탄소섬유시트로 보강된 콘크리트 기둥의 압축성능 평가를 위한 실험연구)

  • Yoo, Youn-Jong;Lee, Kyoung-Hun;Kim, Heecheul;Lee, Young-Hak;Hong, Won-Kee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.3
    • /
    • pp.119-126
    • /
    • 2008
  • In 1980 and 1990's most of residential buildings were constructed with relatively low strength concrete of 18 MPa. And, columns were designed considering only vertical loads. In this study, compressive strength tests for low strength RC columns retrofitted by carbon fiber sheets were carried out. Carbon fiber sheet provides constructability and high tensile strength as well as good corrosion resistance characteristics. A pair of carbon sheets were wrapped with ${\pm}60^{\circ}$ angle with respect to longitudinal direction of RC column to increase structural capacity against axial and lateral load simultaneously. Strength and strain patterns and failure modes of specimens were analyzed and prediction equation of increased compressive strength of RC column confined by carbon fiber sheet was proposed based on regression analysis.

Cyclic Loading Test for Composite Beam-Column Joints using Circular CEFT Columns (콘크리트피복 원형충전강관 기둥-강재보 접합부에 대한 반복하중실험)

  • Lee, Ho Jun;Park, Hong Gun;Choi, In Rak
    • Journal of Korean Society of Steel Construction
    • /
    • v.29 no.6
    • /
    • pp.411-422
    • /
    • 2017
  • In this study, to investigate the seismic performance of beam-column joints using concrete-encased and -filled circular steel tube(CEFT) columns, two types of tests were performed: (1) column - flange tension test and (2) beam - column joint cyclic load test. In column - flange tension test, test parameters were concrete encasement and connection details: flange width and strengthening rebar. Five specimens were tested to investigate the load-carrying capacity and the failure mode. Test results showed that increase of flange width from 200mm to 350mm result in increase of connection strength and stiffness by 61% and 56%, respectively. Structural performances were further improved with addition of tensile rebars by 35% and 92%, respectively. In cyclic loading test, three exterior beam-column joints were prepared. Test parameters were strengthening details including additional tensile rebars, thickened steel tube, and vertical plate connection. In all joint specimens, flexural yielding of beam was occurred with limited damages in the connection regions. In particular, flexural capacity of beam-column joint was increased due to additional load transfer through tube - beam web connection. Also, connection details such as increase of tube thickness and using vertical plate connection were effective in improving the resistance of panel zone.

Satellite (SCIAMACHY) Measurements of Tropospheric SO2 and NO2: Seasonal Trends of SO2 and NO2 Levels over Northeast Asia in 2006 (인공위성 (SCIAMACHY) 데이터를 이용한 대류권 SO2, NO2 측정: 2006년 동북아시아 지역의 계절적 SO2, NO2 변화 추세)

  • Lee, Chul-Kyu;Richter, Andreas;Burrows, John P.;Kim, Young-J.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.2
    • /
    • pp.176-188
    • /
    • 2008
  • Anthropogenic emissions of nitrogen oxides and sulfur dioxide in Northeast Asia are of great concern because of their impact on air quality and atmospheric chemistry on regional and intercontinental scales. Satellite remote sensing based on DOAS (Differential Optical Absorption Spectroscopy) technique has been preferred to measure atmospheric trace species and to investigate their emission characteristics on regional and global scales. Absorption spectra obtained by the satellite-born instrument, SCIAMACHY (Scanning Imaging Absorption Spectrometer for Atmospheric Chartography) have been utilized to retrieve the information of $SO_2$ and $NO_2$ over Northeast Asia. $SO_2$ levels over Northeast Asia were in order of East China, Yellow Sea, South Sea and Korean Peninsula with mean vertical columns of $1.78({\pm}1.0){\times}10^{16}$, $1.11({\pm}0.67){\times}10^{16}$, $0.60({\pm}0.63){\times}10^{16}$, $0.71({\pm}0.65){\times}10^{16}\;molecules/cm^2$, respectively. $NO_2$ levels were in order of East China, Yellow Sea, Korean Peninsula, and South Sea with mean vertical columns of $1.2({\pm}0.56){\times}10^{16}$, $0.38({\pm}0.19){\times}10^{16}$, $0.48({\pm}0.28){\times}10^{16}$, $0.26({\pm}0.16){\times}10^{16}\;molecules/cm^2$, respectively. High levels of $SO_2$ and $NO_2$ were observed over East China, in particular in winter by the contribution of heating fuel combustion exhausts. The $SO_2$ and $NO_2$ levels over East China were the highest in January with 34% and 42% higher over the annual means. Low levels of $SO_2$ ranged over Korean peninsula, while $NO_2$ levels were relatively high, in particular in winter. The $SO_2$ and $NO_2$ levels over Yellow Sea were relatively higher compared to those over Korean peninsula and South Sea, which could be mainly attributed to their transport from East China.

Effect of Salinity-stratified Waters on Upward Migration and Ratio of Extracted DNA/RNA in Cochlodinium polykrikoides Margalef Based on the Ratio of Absorbance at 260 and 280nm (염분 구배가 Cochlodinium polykrikoides Margalef의 수직이동 및 DNA/RNA 비율에 미치는 영향)

  • Cho Eun Seob;Lee Young Sik
    • Journal of Life Science
    • /
    • v.15 no.3 s.70
    • /
    • pp.468-473
    • /
    • 2005
  • The coastal regions of Yeosu, the South Sea of Korea, has occurred annually the red tide which is caused by potentially ichthyotoxic dinoflagellate C. polykrikoides, with a wide avenue for exchange with oceanic waters and freshwater runoff from Sumjin river. We attempted to examine the variability in response to vertical migration and concentration of extracted DNA/RNA of C. polykrikoides exposed to salinity-stratified waters. The experimental aquarium of the 60 liter was employed to culture C. polykrikoides. One aquarium was supplied with only sea water, the other was consisted of sea water and freshwater. Experiment was conducted for 5 days. In experimental column (mixture of freshwater and sea water), salinity was maintained to 20 at upper and approximately 30 at bottom during the period of this study. The fluctuation with related to dissolved oxygen and pH was similar pattern to both columns. Chlorophyll a was significantly higher value at upper than bottom. During 24h, chlorphyll a on experimental column was extremely high on the top as soon as lighting, compared with control. With elapsed time, the gap between experimental and control columns was a little. In darkness, chlorophyll a was not significantly different between upper and bottom, most cells appeared to randomly distribute on column regardless of water layer. Fluctuation with related to concentration of extracted DNA and RNA based on ratio of absorbance of 260 and 280 nm in experimental column was higher at final day or diel migration than control. These results implied that a large volume of freshwater could be associated with influence of concentration of DNA and RNA, in particular, rapid upward movement caused massive fish kills as soon as sunset.

The Strengthening Effects of Concrete Columns Confined with Carbon Fiber Sheets along the Fiber Direction (탄소섬유쉬트 올방향에 따른 콘크리트 기둥 보강성능)

  • Kim, Yang-Jung;Hong, Gap-Pyo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.4
    • /
    • pp.326-332
    • /
    • 2011
  • Carbon, Aramid, Boron and Glass fibers are used as fibrous materials to promote structural bearing strength. Of these fiber types, carbon fiber is the most commonly used material, and is characterized by having a one-way direction, which is strengthened by tensile strength due to the attached direction only, while other types of fibers are two-way. Therefore, when applied in the field, the attachment direction of fiber is a very important factor. However, when fiber direction is not mentioned in the design drawing, there sometimes is no improvement in structural strength, as the fiber is being installed by a site engineer or workers who lack structural knowledge. The purpose of this study was to propose an optimal direction of carbon fiber through a comparison & analysis of reinforcing efficiency with reinforced experimental columns that used carbon fibers in each of the inclined, horizontal and vertical directions. According to the results, horizontal direction in the reinforced column was improved by 153.43%, but vertical direction was 104.61% only, and it was understood this was due to increased tensile strength along the fiber direction. For this reason, it is necessary to include information regarding fiber direction in design and site management.

Capillary Characteristics of Water and Cations in Multi-layered Reclaimed Soil with Macroporous Subsurface Layer Utilizing Coal Bottom Ash

  • Ryu, Jin-Hee;Chung, Doug-Young;Ha, Sang-Keon;Lee, Sang-Bok;Kim, Si-Ju;Kim, Min-Tae;Park, Ki-Do;Kang, Hang-Won
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.47 no.6
    • /
    • pp.406-411
    • /
    • 2014
  • Serious problems in reclaimed land agriculture are high soil salinity and poor vertical drainage, so desalinization in these soils is very difficult. Also, although desalinization is accomplished in reclaimed top soils, before long, soils are resalinized according to capillary rise of salts from the subsurface soils. To resolve these problems, multi-layered soil columns with subsurface layer of macroporous medium utilizing coal bottom ash (CBA) were constructed and the effects of blocked resalinization of these soils were investigated. In this experiment soil samples were collected from Munpo series (coarse-loamy, nonacid, mixed, mesic, typic Fluvaquents). The soil texture was silt loam and the EC was $33.9dS\;m^{-1}$. As for groundwater seawater was used and groundwater level of 1 cm from the bottom was maintained. The overall rate of capillary rise was $2.38cm\;hr^{-1}$ in soil 60 cm column, $0.25cm\;hr^{-1}$ in topsoil (30 cm) + CBA (5 cm) + subsurface soil (10 cm) column and $0.08cm\;hr^{-1}$ in topsoil (30 cm) + CBA (10 cm) + subsurface soil (10 cm) column. In multi-layered soil columns with CBA 20, 30 cm layer, wetting front due to capillary rise could not be seen in top soil layer. After 70 days capillary rise experiment water soluble Na+ accumulated in top soil of soil columns with CBA 20, 30 cm was diminished by 92.8, 96.5% respectively in comparison with Na+ accumulated in top soil of soil 60 cm column because CBA layer cut off capillary rise of salts from the subsurface soil. From these results we could conclude that the macroporous layer utilizing CBA placed at subsurface layer cut off capillary rise of solutes from subsurface soil, resulting in lowered level of salinity in top soil and this method can be more effective in newly reclaimed saline soil.

The Strain of Transverse Steel and Concrete Shear Resistance Degradation after Yielding of Reinforced Concrete Circular Pier (철근콘크리트 원형 교각의 횡방향철근 변형률과 항복이후 콘크리트 전단저항 저감)

  • Ko, Seong Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.1
    • /
    • pp.147-157
    • /
    • 2018
  • The basis of capacity design has been explicitly or implicitly regulated in most bridge design specifications. It is to guarantee ductile failure of entire bridge system by preventing brittle failure of pier members and any other structural members until the columns provides fully enough plastic rotation capacity. Brittle shear is regarded as a mode of failure that should be avoided in reinforced concrete bridge pier design. To provide ductility behavior of column, the one of important factors is that flexural hinge of column must be detailed to ensure adequate and dependable shear strength and deformation capacity. Eight small scale circular reinforced concrete columns were tested under cyclic lateral load with 4.5 aspect ratio. The test variables are longitudinal steel ratio, transverse steel ratio, and axial load ratio. Eight flexurally dominated columns were tested. In all specimens, initial flexural-shear cracks occurred at 1.5% drift ratio. The multiple flexural-shear crack width and length gradually increased until the final stage. The angles of the major inclined cracks measured from the vertical column axis ranged between 42 and 48 degrees. In particular, this study focused on assessing transverse reinforcement contribution to the column shear strength. Transverse reinforcement contribution measured during test. Each three components of transverse reinforcement contribution, axial force contribution and concrete contribution were investigated and compared. It was assessed that the concrete stresses of all specimen were larger than stress limit of Korea Bridge Design Specifications.

A Study on the Displacement and Stress Analysis of Hollow Rollers for a Wire Saw Machine (와이어 소 머신용 중공롤러의 변위량과 응력해석에 관한 연구)

  • Kim, Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.2
    • /
    • pp.10-15
    • /
    • 2014
  • In this paper, the displacement and stress strength safeties have been presented for cylindrical hollow rollers of a wire saw machine. Using the finite element method, the hollow roller with Y-shaped shift and vertical columns between three tubes has been developed to analyze the displacement behavior and stress strength safeties. For the same diameter and length of hollow roller models with a different weight, the displacement behavior safety of Y-shaped shift column and vertical column models is heavily depending on the total length of a hollow roller, which is closely related to the bending moment of a hollow roller structure. But, the stress strength of a hollow roller is more influenced by the cross sectional area of a hollow roller for the similar weight. Thus, this paper recommends Y-shaped hollow roller for increasing the roller strength safety and decreasing a total roller weight.