• 제목/요약/키워드: vertical characteristic

검색결과 536건 처리시간 0.024초

Liquid crystal alignment on rubbed self-assembled monolayers with fluorinated alkyl chain

  • Oh, Chan-Woo;Hwang, Seok-Gon;Park, Sang-Geon;Park, Hong-Gyu
    • 한국정보전자통신기술학회논문지
    • /
    • 제11권6호
    • /
    • pp.671-677
    • /
    • 2018
  • In this paper, we investigated the vertical alignment characteristics of liquid crystals (LCs) on fluorinated self-assembled monolayers (FSAMs). For comparison, a commercialized homeotropic polyimide (PI) layer was used as an LC alignment layer. We confirmed the successful deposition of FSAMs and the change of FSAMs before and after rubbing treatment through contact angle measurement and atomic force microscopy. The optical transmittance spectrum of the FSAMs is similar to that of the homeotropic PI layer, which is a superior optical characteristic applicable to LC devices. When FSAMs were applied to the vertically aligned (VA) LC cell, uniform and vertical LC alignments were achieved. In addition, the voltage-transmittance characteristic of VA LC cell with FSAMs was superior to that of VA LC cell with the conventional homeotropic PI layers. These results indicate that the FSAMs are suitable as the homeotropic LC alignment layer for enhanced LC devices.

압축력이 작용하는 유연보를 이용한 수동 제진기의 준영강성 특성 (Quasi-zero-stiffness Characteristic of a Passive Isolator Using Flexures under Compression Force)

  • 김경홍;안형준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 추계학술대회 논문집
    • /
    • pp.321-321
    • /
    • 2009
  • This paper presents quasi-zero-stiffness (QZS) characteristic of a passive isolator using flexures under compression force. The passive isolator consists of a positive stiffness element (a vertical coil spring) and a negative stiffness element (flexures under compression force), and their proper combination of the positive and negative stiffness elements can produce both substantial static and zero dynamic stiffness, so called QZS. Firstly, a nonlinear dimensionless expression of a flexure under compression force is derived. A dynamic model of the passive isolator is developed and numerical simulations of its time and frequency response are performed. Then, undesirable nonlinear vibration is quantified using a period doubling bifurcation diagram and a Poincare's map of the isolator under forced excitation. Finally, experiments are performed to validate the QZS characteristic of the passive isolator.

  • PDF

DEM 모델을 이용한 평판재하시험의 토양 수직응력 해석 (Soil Stress Analysis Using Discrete Element Method for Plate-Sinkage Tests)

  • 장기찬;이수진;이규진
    • 한국CDE학회논문집
    • /
    • 제20권3호
    • /
    • pp.230-237
    • /
    • 2015
  • Soil deformation on the off-load ground is significantly affected by soil conditions, such as soil type, water content, and etc. Thus, the soil characteristics should be estimated for predicting vehicle movements on the off-load conditions. The plate-sinkage test, a widely-used experimental test for predicting the wheel-soil interaction, provides the soil characteristic parameters from the relationship between soil stress and plate sinkage. In this study, soil stress under the plate-sinkage situation is calculated by the DEM (Discrete Element Method) model. We developed a virtual soil bin with DEM to obtain the vertical reaction forces under the plate pressing the soil surface. Also parametric studies to investigate effects of DEM model parameters, such as, particle density, Young's modulus, dynamic friction, rolling friction, and adhesion, on the characteristic soil parameters were performed.

실증실험용 저온 플라즈마 반응기의 유동특성에 관한 연구 (A Study on the Flow Characteristic of Non-Thermal Plasma Reactor for Demonstration)

  • 김유석;최석호;김정일;김태희;유정석;백민수;장길홍
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.508-513
    • /
    • 2000
  • HANJUNG has developed demonstration plant treating combustion flue gas such as dioxide($SO_2$) and nitrogen oxides(NOx). Before operating this system, we tested the inner airflow characteristic of demonstration plant in the front of plasma reactor field 1 and field 2. The experimental results of $25,000Nm^3/hr$ airflow are compared with the computational results using FLUENT code. It is found that the velocity distribution trends are matched the experimental results with the calculation results. To improve the eccentric airflow in the inlet hood, it is necessary to install the vertical guide vane as well as the horizontal guide vane.

  • PDF

시뮬레이션을 이용한 화재 시 고층건축물의 압력분포 특성에 관한 연구 (A Sutdy on the Pressure Distribution Characteristic of High-rise Buildings in Fire Using Computer Simulation)

  • 김혜원;이병흔;진승현;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.49-50
    • /
    • 2019
  • In the case of High-rise buildings, it has a problem by stack effect that rise of vertical height. Especially in case of fire, it need to the consideration of stack effect that it has bigger than general. Therefore in this study, we used to the Contamw and FDS simulation for analysis of stack effect and pressure distribution characteristic in fire. As a result the Contamw simulation shows the pressure distribution by stack effect in general high-rise buildings. However, in case of fire, the height of the neutral plane is lowered and stack effect is larger. Therefore, it is necessary to multiply analyze the temperature distribution and the stack effect in fire.

  • PDF

스퍼터링으로 경사증착한 $SiO_x$ 박막을 이용한 VA-LCD의 전기광학특성 (Electro-Optical Characteristic for VA-LCD on the $SiO_x$ Thin Film Layer Oblique Deposited by Sputtering Method)

  • 최성호;황정연;김성연;오병윤;명재민;서대식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.451-452
    • /
    • 2006
  • We studied the electro-optical characteristic of vertical alignment liquid crystal display(VA-LCD) on the $SiO_x$ thin film deposited $45^{\circ}$ oblique by rf magnetic sputtering system. LC alignment characteristic showed homeotropic alignment, and pretilt angle was about $90^{\circ}$. A uniform liquid crystal alignment effect on the $SiO_x$ thin film was achieved and the electro-optical characteristic of the $SiO_x$ thin film deposited $45^{\circ}$ oblique by rf magnetic sputtering system was excellent.

  • PDF

광전계 센서를 이용한 구형 Loop Antenna의 근접전계 특성 (Characteristic for the Near Field of Rectangle Loop Antenna using Optical Electric-Field Sensor)

  • 이주현;도쿠다마사미추;하덕호
    • 한국전자파학회논문지
    • /
    • 제14권3호
    • /
    • pp.217-225
    • /
    • 2003
  • 본 논문에서는 전파암실(8.5 m x 7 m x 7 m)에서 광전계센서를 이용한 Loop Antenna의 근접전계 분포특성을 파악하기 위해 시간 및 주파수 영역에 대하여 측정한 후 시뮬레이션 결과와 비교 분석하였다. 시뮬레이션은 MoM와 FDTD을 이용하여 각각 주파수 및 시간영역에 대하여 시뮬레이션 하였다. 그 결과 측정 과 시뮬레이션이 상당히 일치하였으며, 측정에 이용한 광전계 센서의 유효성을 확인하였다. 또한, 주파수 영역에 있어서 Loop Antenna의 수직 엘리멘트 근접에 광전계 센서를 각각 수직 과 수평편파로 한 경우 약 15 ㏈ 정도의 차이를 보였고 Loop Antenna의 수평 엘리멘트 보다 높은 곳에서는 신호레 벨의 별다른 차이가 없었다. 그리고, 시간영역에 있어서는 Loop Antenna의 수평 엘리멘트 보다 높은 곳에서 광전계센서를 수직편파로 한 경우의 수신펄스 모양은 부(-)의 방향으로 됨을 알 수 있었다.

스트립형 섬유 보강 탄성받침의 실험에 의한 기계적 특성해석 (Mechanical Characteristic Analysis of Fiber Reinforced Strip Form Elastomeric Bearing by Experiment)

  • 강경주;문병영;강범수;김계수;박진삼
    • 한국지진공학회논문집
    • /
    • 제6권6호
    • /
    • pp.1-6
    • /
    • 2002
  • 기존의 면진 기술을 일반건물에 적용하기 위해서는 낮은 가격과 낮은 무게로 면진 탄성받침 이 제작 및 공급되어야 할 필요가 있다. 이에 본 논문에서는 일반건물에 면진 기술을 적용하기 위한 방법으로 기존의 적층고무 면진 탄성받침에 철판을 대체하여 섬유로 보강하고, 고무와 섬유의 층으로 구성된 스트립형의 면진 탄성받침을 제안하였다. 또한 제안한 섬유보강 면진 탄성받침을 설계 및 제작하여 수직실험과 수평실험을 수행하여 그 성능을 검증하였다. 따라서, 스트립형의 면진 탄성받침이 제작가능하며, 필요한 크기로 절단이 가능함을 보였다. 또한 수평 실험 수직 실험을 통하여 기존의 적층고무 면진 탄성받침을 대체하여 사용할 수 있음을 보였다. 이 연구결과로 인해 스트립형의 섬유보강 면진 탄성받침이 저가건물에 널리 사용될 수 있을 것으로 기대된다.

수직 지질구조에 의해서 지배되는 암반지하수 유동의 수리적 성질과 그 예 (Hydraulic Eroperty of Groundwater Flow Controlled by Vertical Geologic Structure and its field Example)

  • 함세영;김형찬;임정웅
    • 대한지하수환경학회지
    • /
    • 제5권2호
    • /
    • pp.101-109
    • /
    • 1998
  • 암반대수층의 수리적 특성은 지하수의 통로가 되는 지질구조에 의해서 크게 좌우된다. 본 연구에서는 수직 지질구조와 관련된 일차원 흐름의 이론들에 대해서 논하였다. 그리고, 경북 영일군 대송면 옥명리에서 행한 두 번의 양수시험(양수시험 1과 양수시험 2)에 대해서, 프락탈 모델을 적용하여 이 지역 수리 특성을 분석하였다. 양수시험분석에 의하면, 양수시험 1(양수정 : D9호공, 관측정 : C3호공과 D7호공)의 시험공 주변은 무한한 길이의 그리고 무한소의 폭을 가지는 수직 지질구조에 의해서 지배되는 일차원 흐름으로 대표되나, 양수시험2의 양수정(D10호공) 주변은 이차원에 가까운 흐름(1.9∼2차원)을 보인다. 이와 같이, 균열암반대수층의 특징은 공간적으로 또는 시간적으로 유동 차원이 달라지는 경우가 많다.

  • PDF

실내모형시험을 통한 연직배수재의 통수능력 및 스미어존 영향 평가 (A Assessment of Discharge Capacity of Vertical Drains and Smear Zone Effect from Model Test)

  • 천병식;김의석;도종남;국길근
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.1136-1143
    • /
    • 2008
  • The Vertical Drains(Sand Drains, Pack Drain, PBD) is used for Vertical Drains Method in domestic. Each of the drains is selected after it consider a field condition and efficiency of drain. A discharge capacity is very important factor, which to estimate a efficiency. And the smear Zone where disturbance area of in-suit by installation of Vertical Drains is important factor to select a drains. In this study, the complex discharge capacity test was operated for discharge capacity comparison of the Wing Drain and PBD. And a model test was operated to apprehend smear zone of the Wing Drain and PBD. From these tests, it was apprehended an engineering characteristic of vertical drain. The results of the complex discharge capacity test, a discharge capacity fell below $20cm^3/sec$ to $1cm^3/sec$ in more than overburden load $2.5kg/cm^2$. The Wing Drain maintained a over $40cm^3/sec$ in more than overburden load $2.5kg/cm^2$ and minimum discharge capacity $8cm^3/sec$. The results of the smear zone test, a influence bounds of smear zone was more larger in case of the Wing Drain(rectangle) than the PBD. But when a discharge capacity of Wing Drain is considered, it was concluded which smear zone bounds difference was effected in comparison with PBD. I think that it minimized a mandrel section to minimize a smear zone effect range

  • PDF