• Title/Summary/Keyword: verification tests

Search Result 795, Processing Time 0.027 seconds

An Improved Quadratic Finite Element with Modified Integration Order (수정된 적분차수를 이용한 평면유한요소의 개선)

  • 김선훈;김주일;이창원;신재철
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2001.04a
    • /
    • pp.42-49
    • /
    • 2001
  • In this paper the efficient finite element for stress analysis of plane stress/strain problems is proposed. This element is achieved by adding the bubble-mode function to 8-node element. The stiffness matrix of the element is calculated by using modified numerical integration order to avoid spurious zero energy mode. In order to demonstrate the performance of this element numerical tests for various verification problems are carried out. The results of numerical tests show accuracy and reliability of the element presented in this paper.

  • PDF

A Verification Test on Safety Standards of Portable Propane Gas Stove for Safe Camping Culture (안전한 캠핑 문화의 정착을 위한 야외용 프로판 연소기 안전기준 실증 연구)

  • Ahn, Hyun-Soo;Choi, Suel-Ki;Lee, Chang-Eon;Kim, Young-Gu
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.293-294
    • /
    • 2014
  • In Korea, only butane gas could be used as fuel gas of the outdoor gas stove. However, butane is not vaporized well at low temperatures. For this reason, in the field, nozzle of the portable butane gas stove is converted illegally to use propane gas. Because vapor pressure of propane gas is higher than that of butane gas at same temperature, gas accidents such as gas leakage could be occurred. To prevent gas accidents and use portable propane gas stoves safely, international standards need to be analyzed and verification tests need to be performed with prototype stove. This study could suggest to revise standard for safety improvement with portable propane gas stoves.

  • PDF

Design and Verification of Electrical System for Unmanned Aerial Vehicle through Electrical Load Power Analysis (전원부하분석을 통한 무인항공기 전기시스템 설계 및 검증)

  • Woo, Heechae
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.21 no.5
    • /
    • pp.675-683
    • /
    • 2018
  • In this paper, we have proposed a design and verification methods of electrical system and power loads for unmaned aeriel vehicles(UAVs) through electrical load analysis. In order to meet a UAV system requirement and electrical system specifications, we have designed an electrical power system for efficient power supply and distribution and have theoretically analyzed the power loads according to the power consumption and power bus design of UAV. Using electrical system rig, the designed electrical power system has been experimentally verified. Also, we have performed several flight tests to verify the UAV electrical system and power loads. It is concluded that the proposed design and verification method of electrical system for UAV system.

The Verification Test of Launch Control System Algorithms Using Automated Verification System (자동화 검증시스템을 이용한 발사관제시스템 알고리즘 검증시험)

  • An, Jae-Chel;Moon, Kyung-Rok;Oh, Il-Seok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.25 no.3
    • /
    • pp.127-137
    • /
    • 2021
  • The launch complex(LC) is composed of various facilities. The launch control system that operates remotely those of LC spends much time and labor for developing and verifying its control algorithms. The verification of algorithms is performed by the software developer entering simulated state values based on the test procedure and checking the output result according to the algorithm flow. These verification processes should be performed repeatedly, thus the human errors are easily occurred. In this paper, an efficient automated verification method with a script test procedure is proposed to minimize human errors and shorten the verification duration. We also present the results of the algorithm verification tests for the cases of the compressed gases supply system and the electro pneumatic panel system of LC.

Dynamic equivalent model of a SMART control rod drive mechanism for a seismic analysis

  • Ahn, Kwanghyun;Lee, Jae-Seon
    • Nuclear Engineering and Technology
    • /
    • v.52 no.8
    • /
    • pp.1834-1846
    • /
    • 2020
  • The SMART (System-integrated Modular Advanced ReacTor) is an integral-type small modular reactor developed by KAERI (Korea Atomic Energy Research Institute). This paper discusses the development of a dynamic equivalent model of the SMART control rod drive mechanism that can be efficiently utilized for complicated analysis during the design of the SMART. A semi-empirical approach is used to develop the equivalent model; that is, the equivalent model is defined analytically and verified empirically. Two types of tests, dynamic characteristics tests and seismic loading tests, are conducted for the development and verification of the dynamic equivalent model, respectively. Acceleration response spectra from the seismic analysis based on the developed equivalent model show good agreement with those from the seismic loading tests.

Experimental verification of shear and frictional characteristics in end milling (엔드밀링시 전단 및 마찰 특성의 실험적 검증)

  • Lee, Y. M.;S. H. Yang;M. Chen;S. I. Jang
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1789-1794
    • /
    • 2003
  • As a new approach to analyze shear behaviors in the shear plane and chip-tool friction behaviors in the chip-tool contact region during an end milling process, this paper introduces a method to transform an end milling process to an equivalent oblique cutting process. In this approach, varying undeformed chip thicknesses and cutting forces in the up-and down-end milling process are replaced with the equivalent ones of oblique cutting. Accordingly, in the current paper, the shear and friction characteristics of end milling operations, up- and down-end milling, have been analyzed based on the equivalent oblique cutting models. Two series of cutting tests, up- and down-end milling tests and the equivalent oblique cutting tests to that, have been carried out to verify the validity of the analyses. And using the results of cutting tests the cutting characteristics of the up- and down-end milling processes have been thoroughly investigated.

  • PDF

Verification Methods for the Implementation of Non-functional Requirements in Web-based Learning Systems (웹 기반 학습 시스템의 비기능 요구에 대한 구현 검증 기법 연구)

  • Seo, Dongsu;Lee, Heyli
    • The Journal of Korean Association of Computer Education
    • /
    • v.9 no.4
    • /
    • pp.43-54
    • /
    • 2006
  • In general, user requirements in web-based learning systems are divided into functional and non-functional requirements. Developers are responsible for the verification of quality related requirements, which is known to be difficult to perform. This paper suggests a verification method that can be applied in the area where the conformance of implementation for non-functional requirements is required. The paper performs tests for non-functional requirements by using the information extracted from quality related features that have imposed constraints on design activities.

  • PDF

Air Similarity Test and Analysis of Steam Turbine Labyrinth Seal for Leakage Verification (스팀터빈용 래비린스 실의 누설량 규명을 위한 공기상사 실험 및 해석)

  • Ahn, Sang-Kyu;Kim, Seung-Jong;Lee, Yong-Bok;Kim, Chang-Ho;Ha, Tae-Wong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1149-1149
    • /
    • 2006
  • The leakage characteristic is an important factor in power plant. However, most of power plant have efficiency problem which is occurred leaking between high pressure steam turbine axle and stator. The labyrinth seal which is used between the main turbine axle and stator in the power plant. Because it is able to be non-contact seal and it is minimize clearance to decrease the leakage. But its actual system is too huge to experiment. Therefore, most steam turbine seal performance tests were conducted by air similarity test. This paper described a test facility and program for air similarity test of high pressure steam turbine seal. A test facility has been designed and built to evaluate leakage verification of labyrinth seal. The test facility consist of air compressor, anti-swirl labyrinth seal for 1/3 air similarity model, pressure transducer, air flow measure system, instrumentation and auxiliary system. For evaluation of steam turbine seal performance, the air similarity test of labyrinth seal leakage verification was conducted and we compared experiment data and analysis result.

  • PDF

KOMPSAT-2 Payload Downlink System Verification (아리랑 위성 2호 탑재체 하향링크 시스템 검증)

  • Lee, Jin-Ho;Kim, Hui-Seop;Cheon, Yong-Sik
    • Aerospace Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.108-113
    • /
    • 2006
  • This paper includes the test results of KOMPSAT-2 payload downlink system which were measured for the purpose of performance verification. The antenna beam patterns which indicates the status of the interface & antenna itself, were measured as well as the antenna VSWR. The checkout of the transponder & its spectrum was followed and this made sure that there was no spurious output distinguished. Finally a test for BER verification was conducted between satellite and receiving system for their compatibility through the antenna-to-antenna connection using an antenna hat. Verification tests for an RF system should be performed after relocation, integration and test for environments in order to make sure that no degradation happens.

  • PDF

Accuracy of Combined Visual Inspection with Acetic Acid and Cervical Cytology Testing as a Primary Screening Tool for Cervical Cancer: a Systematic Review and Meta-Analysis

  • Chanthavilay, Phetsavanh;Mayxay, Mayfong;Phongsavan, Keokedthong;Marsden, Donald E;White, Lisa J;Moore, Lynne;Reinharz, Daniel
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.14
    • /
    • pp.5889-5897
    • /
    • 2015
  • Background: The performance of combined testing visual inspection with acetic acid (VIA) and cervical cytology tests might differ from one setting to another. The average estimate of the testing accuracy across studies is informative, but no meta-analysis has been carried out to assess this combined method. Objective: The objective of this study was to estimate the average sensitivity and specificity of the combined VIA and cervical cytology tests for the detection of cervical precancerous lesions. Materials and Methods: We conducted a systematic review and a meta-analysis, according to the Cochrane Handbook for Systematic Review of Diagnostic Test Accuracy. We considered two cases. In the either-positive result case, a positive result implies positivity in at least one of the tests. A negative result implies negativity in both tests. In the both-positive case, a positive result implies having both tests positive. Eligible studies were identified using Pubmed, Embase, Website of Science, CINHAL and COCRANE databases. True positive, false positive, false negative and true negative values were extracted. Estimates of sensitivity and specificity, positive and negative likelihood (LR) and diagnostic odds ratios (DOR) were pooled using a hierarchical random effect model. Hierarchical summary receiver operating characteristics (HSROC) were generated and heterogeneity was verified through covariates potentially influencing the diagnostic odds ratio. Findings: Nine studies fulfilled inclusion criteria and were included in the analysis. Pooled estimates of the sensitivities of the combined tests in either-positive and both-positive cases were 0.87 (95% CI: 0.83-0.90) and 0.38 (95% CI: 0.29-0.48), respectively. Corresponding specificities were 0.79 (95% CI: 0.63-0.89) and 0.98 (95% CI: 0.96-0.99) respectively. The DORs of the combined tests in either-positive or both-positive result cases were 27.7 (95% CI: 12.5-61.5) and 52 (95% CI: 22.1-122.2), respectively. When including only articles without partial verification bias and also a high-grade cervical intraepithelial neoplasia as a threshold of the disease, DOR of combined test in both-positive result cases remained the highest. However, DORs decreased to 12.1 (95% CI: 6.05-24.1) and 13.8 (95% CI: 7.92-23.9) in studies without partial verification bias for the combined tests in the either-positive and both-positive result cases, respectively. The screener, the place of study and the size of the population significantly influenced the DOR of combined tests in the both-positive result case in restriction analyses that considered only articles with CIN2+ as disease threshold. Conclusions: The combined test in the either-positive result case has a high sensitivity, but a low specificity. These results suggest that the combined test should be considered in developing countries as a primary screening test if facilities exist to confirm, through colposcopy and biopsy, a positive result.