• 제목/요약/키워드: ventricular assist

검색결과 133건 처리시간 0.032초

벨로우즈 방식의 폐회로를 가진 공압식 심실 보조장치의 최적 작동을 위한 압력 조절 시스템 (Pressure Regulation System for Optimal Operation of the Pneumatic VAD with Bellows-Type Closed Pneumatic Circuit)

  • 김범수;이정주;남경원;정기석;안치범;선경
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권4호
    • /
    • pp.569-576
    • /
    • 2007
  • Ventricular Assist Device(VAD) has switched its goal from a short-tenn use for bridge-to-transplantation to a long-tenn use for destination therapy, With this goal, the importance of long-tenn reliability gets more interests and importances, H-VAD is an portable extracorporeal biventricular assist device, and adopts an electro-pneumatic driving mechanism. The pneumatic pressure to pump out blood is generated with compression of bellows, and is transmitted in a closed pneumatic circuit through a pneumatic line. The existing pneumatic VAD adopts a air compressor which can generate stable pressures but has defects such as a noise and a size problem. Thus, it is not suitable for being used as a portable device, These problems are covered with adopting a closed pneumatic circuit mechanism with a bellows which has a small size and small noise generation, but it has defects that improper pneumatic setting causes a failure of adequate flow generation. In this study, the pneumatic pressure regulation system is developed to cover these defects of a bellows-type pneumatic VAD. The optimal pneumatic pressure conditions according to various afterload conditions for an optimal flow rate were investigated and the afterload estimation algorithm was developed, The final pneumatic regulation system estimates a current afterload and regulate the pneumatic pressure to the optimal point at a given afterload condition. The afterload estimation algorithm showed a sufficient performance that the standard deviation of error is 8.8 mmHg, The pneumatic pressure regulation system showed a sufficient performance that the flow rate was stably governed to various afterload conditions. In a further study, if a additional sensor such as ultrasonic sensor is developed to monitor the direct movement of diaphragm in a blood pump part, the reliability would be greatly increased. Moreover, if the afterload estimation algorithm gets more accuracy, it would be also helpful to monitor the hemodynamic condition of patients.

생체실험을 통한 좌심실보조기의 평가 (Evaluation of Left Ventricular Assist Device through In Vivo Experiments)

  • 박성근;원용순;정필섭;최진욱;김인영;이규백;민병구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1993년도 추계학술대회
    • /
    • pp.89-92
    • /
    • 1993
  • In this article, we present and analyze the results of the three consecutive in vivo experiments of the LVAD to evaluate the function of the LVAD and the adverse effects on living animals. We applied the LVAD consecutively to three mongrel dogs and the circulation of the blood was assisted under the anesthesia. We used in general both the asynchronous mode and the synchronous mode to drive the LVAD. During the experiments we monitored the dogs with a polygraph to evaluate the function of the LVAD and the additional effects on the natural hearts. We also examined several clinical pathologic tests in order to see the effects of the LVAD to the red blood cells and the other internal organs. The dogs survived for two to there days. The LVAD assisted the circulatory system at the maximum assist flow rate of 3.0 1/min. Although the red blood cells of the dogs had mechanical damages by the LVAD to result in the hemolysis, the degree of the hemolysis was not so high and the damages caused by the hemolysis on the dogs were not serious. The myocardium of the first dog was gradually worsened and eventually failed. The damage of the myocardium was due to the asynchronous driving mode of the LVAD. The other organs did not have serious damages due to the application of the LVAD. The main purpose of this paper is to evaluate the results of the in vivo experiments of the LVAD and to find better ways to the application of the LVAD to human beings.

  • PDF

공압식 심실 보조기의 동물실험 (Animal Experiment of the Pneumatic Ventrivular Assist Device)

  • 박성식;김삼현;서필원;최창휴;이상훈;이혁수;황승옥;안혁
    • Journal of Chest Surgery
    • /
    • 제32권12호
    • /
    • pp.1065-1077
    • /
    • 1999
  • Background : Ventricular assist devices(VADs) are being used for patients in postcvardiotomy cardiogenic shock status bridge to cardiac transplant settings and in post-myocardial infarction cardiogenic shock. The VAD which was developed at the Deparment of medical engineering in Dankook University College of Medicine was a pneumatically driven device and can maintain pulsatile flow. The goal of this study is to develop animal experimental models using the VAD and to clarify the reliability and hemodynamic property adequacy of end organ perfusion durability and severity of thrombotic-hemolytic tendency of the device. Material and Method : The pneumatic VAD was applied to 8 adult female lambs, We examined some hemodynamic parameters such as arterial blood pressure pulmonary capillary wedge pressure(pcwp) pulmonary artery pressure(PAP) left atrial pressure hour urine output cardiac index VAD flow EKG to determine the reliability of the VAD and hemodynamic compatibility of the experimental animals within 24 hours of experiment. We also observed the end organ perfusion durability of the VAD and thrombotic-hemolytic property of the VAD after 24 hours of VAD insertion. Result: We could monitor all hemodynamic parameters including pcwp PAP cardiac index EKG, adn hour urine as true clinical settings. We observed that the reliability of the VAD was excellent and the hemodynamic property of the experimental animal and end organ perfusion were adequate within 24 hours of experiment. In four lambs surviving 24 hours after insertion the reliability of the VAD and end organ perfusion were excellent and no thrombotic-hemolytic tendency was noted. However after 15 days of experiment the diaphragm of the VAD was torn and it was recommende that the durability of the VAD should be extended. Conclusion : e conclude that the pneumatic VAD developed at Dankook University Biomedical Engineering has good hemodynamic property and low thromboembolic tendency and presents adequate end organ perfusion but we noted that the durability of the device should be expanded further. It will be possible to do more reliable experiment in the future according to the animal experimental method developed in this study especially with the heart failure models.

  • PDF

혈액 펌프의 기계적 성능과 생체 역학적 성능에 대한 연구 (INVESTIGATION ON MECHANICAL AND BIO-MECHANICAL PERFORMANCE OF A CENTRIFUGAL BLOOD PUMP)

  • 장민욱;;허남건;강성원;김원정;강신형
    • 한국전산유체공학회지
    • /
    • 제20권2호
    • /
    • pp.88-95
    • /
    • 2015
  • Blood pump analysis process includes both mechanical and bio-mechanical aspects. Since a blood pump is a mechanical device, it has to be mechanically efficient. On the other hand, blood pumps function is sensitively related to the blood recirculation; hence, bio-factors such as hemolysis and thrombosis become important. This paper numerically investigates the mechanical and bio-mechanical performances of the Rotaflow in the extracorporeal membrane oxygenation(ECMO), Ventricular Assist Device(VAD), and full-load conditions. The operational conditions are defined as(400[mmHg], 5[L/min.]), (100[mmHg], 3[L/min.]), and (600[mmHg], 10[L/min.]) for ECMO, VAD, and full-load conditions, respectively. The results are presented and analyzed from the mechanical aspect via performance curves, and from bio-mechanical aspect via focusing on hemolytic characteristics. Regions of top and bottom cavities show recirculation in both ECMO and VAD condtions. In addition, Eulerian-based calculation of modified index of hemolysis(MIH) has been investigated. The results demonstrate that the VAD condition has the least risk of hemolysis among the others, while the full-load condition has the highest risk.

Influence of Blade Outlet Angle and Blade Thickness on Performance and Internal Flow Conditions of Mini Centrifugal Pump

  • Shigemitsu, Toru;Fukutomi, Junichiro;Kaji, Kensuke
    • International Journal of Fluid Machinery and Systems
    • /
    • 제4권3호
    • /
    • pp.317-323
    • /
    • 2011
  • Mini centrifugal pumps having a diameter smaller than 100mm are employed in many fields; automobile radiator pump, ventricular assist pump, cooling pump for electric devices and so on. Further, the needs for mini centrifugal pumps would become larger with the increase of the application of it for electrical machines. It is desirable that the mini centrifugal pump design be as simple as possible as precise manufacturing is required. But the design method for the mini centrifugal pump is not established because the internal flow condition for these small-sized fluid machines is not clarified and conventional theory is not suitable for small-sized pumps. Therefore, we started research on the mini centrifugal pump for the purpose of development of high performance mini centrifugal pumps with simple structure. Three types of rotors with different outlet angles are prepared for an experiment. The performance tests are conducted with these rotors in order to investigate the effect of the outlet angle on performance and internal flow condition of mini centrifugal pumps. In addition to that, the blade thickness is changed because blockage effect in the mini centrifugal pump becomes relatively larger than that of conventional pumps. On the other hand, a three dimensional steady numerical flow analysis is conducted with the commercial code (ANSYS-Fluent) to investigate the internal flow condition. It is clarified from the experimental results that head of the mini centrifugal pump increases according to the increase of the blade outlet angle and the decrease of the blade thickness. In the present paper, the performance of the mini centrifugal pump is shown and the internal flow condition is clarified with the results of the experiment and the numerical flow analysis. Furthermore, the effects of the blade outlet angle and the blade thickness on the performance are investigated and the internal flow of each type of rotor is clarified by the numerical analysis results.

웹 기반 인공심장 모니터링 시스템의 설계와 구현 (Design and Implementation of the Web-based Monitoring System for an Artificial Heart)

  • 정진한;최재순;이지훈;민병구
    • 대한의용생체공학회:의공학회지
    • /
    • 제23권2호
    • /
    • pp.131-137
    • /
    • 2002
  • 이동 작동기형 인공 심장의 원격 모니터링을 위한 시스템을 설계, 구현하였다 동물 실험이나 환자에의 임상 실험 후 인공 심장 동작 상황에 대한 원격 모니터링은 필수적이다. 본 논문에서는 담당자가 환자로부터 멀리 떨어진 곳에 있을 때에도 인터넷을 통해 간편하게 인공 심장의 동작 상황과 혈류역학 정보를 확인할 수 있는 시스템을 제안하여 그 성능을 확인하였다. 기존의 시스템과 쉽게 연결하여 사용할 수 있도록. 또 쉬운 관리와 기능 향상을 위하여 COM(Component Object Model) 기술 기반의 콤포넌트 모듈로 데이터 전송 부분을 구현하였고. 범용의 브라우저를 이용하여 인터넷에 연결, 확인토록 자바 애플릿을 이용하여 실행되도록 하였다. 또한 정해진 룰에 따라 판단하여 인공 심장의 이상 동작시 관리자에게 알려주도록 하였다. 구현된 시스템을 1개월 이상 생존하는 동물에 적용하여 본 결과 아무런 문제없이 정상 동작함을 확인하였다.

캐뉼라를 이용한 전기유압식 좌심실 보조기의 개발에 관한 연구 (Development of Cannula type Electrohydraulic Left Ventricular Assist Device)

  • 최진욱;이규백;고영환;김화룡;정대영;김철생;박재형;민병구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1991년도 추계학술대회
    • /
    • pp.70-74
    • /
    • 1991
  • 좌심실보조기의 임상응용범위를 넓히기 위해서 개심술을 하지 않고 좌심실보조기를 적용할 수 있도록 캐뉼라형 좌심실보조기를 이용한 보조순환 실험을 하였다. 좌심실 보조기는 모터의 회전력이 PVC 벨로우즈를 수측, 팽창시키는 전기유압식으로 구동되며 환자는 양쪽 대퇴동맥을 통하여 보조순환을 받도록 되어 있다. 두차례의 동물실험을 통하여 대퇴동맥을 통한 보조 순환방식의 가능성 및 그 효과에 대해서 관찰하였다. 첫 실험은 12kg 개를 이용하여 셀딩거 방법으로 뮬린형 카테터를 디퇴동맥으로 삽입히여, 캐뉼라형 보조순환방법의 가능성을 확인하였고, 두번째 동물실험에서는 내경 4.8 mm의 PVC 카테터를 이용하여 좌심방에 유입카테터를 연결하고 대동맥에 유출카테터를 연결하여 보조순환에 의한 대동맥압의 변화와 혈류량의 변화를 관찰하였다. 보조순환동안 개의 동맥압을 100mmHg로 유지할 수 있었으며, 좌심실내압이 감소하는 것을 관찰할 수 있었다.

  • PDF

좌심방압 변화가 좌심실보조기 박출량에 미치는 영향에 대한 연구 (Effect of Low Left Atrial Pressure on the Pump Output of Left Ventricular Assist Device)

  • 최진욱;이상우;정찬일;김화룡;이연길;이계한;김철생;민병구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 추계학술대회
    • /
    • pp.141-145
    • /
    • 1992
  • 심부전 환자의 심근회복을 도울 수 있는 장비인 전기유압방식 좌심실보조기를 개발하였다. 좌심실보조기는 혈액펌프, 압력펌프, 제어기로 구성되어 있으며, 혈액펌프에 내장된 혈액주머니는 동물실험을 위하여 50 ml의 크기로 제작하였다. 좌심실보조기의 성능평가를 위하여 최대 박출량을 측정하고 있으나 실험실에서 측정된 간은 동물 실험에서 관찰되는 것보다 일반적으로 증가된 박출량을 보이게 된다. 이는 생체에서는 좌심방의 체적이 박동 주기에 따라 변하여 좌심실보조기가 받아들일 수 있는 유효 혈액량이 변하는 반면, 모의순환장치에서는 좌심방을 단순 저장고로 사용하기 때문에 좌심방의 박동주기에 따른 체적변화를 감안하지 못하여 생기는 것이다. 본 실험에서는 모의순환 장치에 체적변화 가능한 100ml 크기의 좌심방을 연결하여 좌심방으로 들어오는 혈류량이 제한된 동물실험 상황을 모방하였다. 좌심실보조기의 제어방식중 수측기 이완기 비율(SD 비율)변화에 따른 좌심방 음압발생효과를 관찰한 결과 SD 비율을 40 %로 유지하면 행정거리가 클때도 좌심실의 음압발생을 줄일 수 있는 것을 관찰하였다.

  • PDF

소아에서 개심술후 정중흉골절개의 지연흉골폐쇄에 의한 심장압박 방지효과 (Cardiac Decompressing Effect by Delayed Sternal Closure Following Open Heart Surgery in Children)

  • 김경환;서경필
    • Journal of Chest Surgery
    • /
    • 제30권12호
    • /
    • pp.1167-1174
    • /
    • 1997
  • 저자들은 1991년부터 1996년까지 5년간 지연 흉골 폐쇄를 시행한 20명의 환자를 분석하고 추적 조사 하였다. 남녀비는 11:9였고 평균연령은 6.4개월(범위 7일-5년)이었다. 적응증으로는 개심술후 심근부종에 기인한장치한 불안정한 혈역학적 상태로 인한 것이 15례로 가장 많았고, 심폐기 이탈 불가로 심실 보조 장치를 경우에서가 3례, 폐동맥 밴딩술 후 저산소증으로 인한 것이 2례 등이었다. 흉골 봉합은 술후 평균 102시간(범위 4-213시간)에 이루어졌으며 시행 후 중심 정맥압의 유의한 상승이 관찰되었다. 종격 동염, 환부 감염 등은 없었으며 2례에서 패혈증이 관찰되었다. 5명이 사망하였고 생존환자 15명중 2명 이 술후 추적관찰 기간 중 사망하였다. 누적 생존률은 1년과 2년에서 각각 65.0%였다. 지연 흉골 봉합 은 혈역학적으로 불안정한 심장을 감압하는 좋은 방법이며 성공적인 결과를 얻기 위해서는 적응증에 대한 신중한 고려가 선행되어야 한다고 생각된다.

  • PDF

A preliminary simulation for the development of an implantable pulsatile blood pump

  • Di Paolo, Jose;Insfran, Jordan F.;Fries, Exequiel R.;Campana, Diego M.;Berli, Marcelo E.;Ubal, Sebastian
    • Advances in biomechanics and applications
    • /
    • 제1권2호
    • /
    • pp.127-141
    • /
    • 2014
  • A preliminary study of a new pulsatile pump that will work to a frequency greater than 1 Hz, is presented. The fluid-structure interaction between a Newtonian blood flow and a piston drive that moves with periodic speed is simulated. The mechanism is of double effect and has four valves, two at the input flow and two at the output flow; the valves are simulated with specified velocity of closing and reopening. The simulation is made with finite elements software named COMSOL Multiphysics 3.3 to resolve the flow in a preliminary planar configuration. The geometry is 2D to determine areas of high speeds and high shear stresses that can cause hemolysis and platelet aggregation. The opening and closing valves are modelled by solid structure interacting with flow, the rhythmic opening and closing are synchronized with the piston harmonic movement. The boundary conditions at the input and output areas are only normal traction with reference pressure. On the other hand, the fluid structure interactions are manifested due to the non-slip boundary conditions over the piston moving surfaces, moving valve contours and fix pump walls. The non-physiologic frequency pulsatile pump, from the viewpoint of fluid flow analysis, is predicted feasible and with characteristic of low hemolysis and low thrombogenesis, because the stress tension and resident time are smaller than the limit and the vortices are destroyed for the periodic flow.