• 제목/요약/키워드: ventricular assist

검색결과 133건 처리시간 0.029초

공압식 심실보조장치의 개발 및 평가 (Development and Evaluation of Pneumatic Ventricular Assist Device)

  • 이상훈;박이태;김삼현;한동선;이학중
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 춘계학술대회
    • /
    • pp.247-250
    • /
    • 1995
  • The purpose of this paper is to develop diaphragm-type pneumatic ventricular assist device(VAD) for clinical application and to evaluate its performance through the mock circulation system. The blood housing and diaphragm are made by coating pellethane on the metallic mold and the back plate is made by machining process. The relations of cardiac output(CO) vs. beat rate and CO vs. systolic-to-diastolic rate was estimated through the mock test and hemodynamic waves are recorded for the evaluation of VAD. As a result, the volume of blood pump is 70 ml, maximum CO is 5 L/min and CO has a close relation to the input resistance of blood pump. The hemodynamic data and waves showed this system can be applicable to the animal experiment.

  • PDF

퍼지로직을 이용한 전기유압식 좌심실 보조장치의 유입혈류량 조절 알고리즘의 개발 (Development of an Algorithm for Regulation of Inlet Blood Flow in Electrohydraulic Left Ventricular Assist Device Using Fuzzy Logic)

  • 최재순;최원우;조영호;박성근;민병구
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 1995년도 추계학술대회 학술발표 논문집
    • /
    • pp.387-392
    • /
    • 1995
  • 전기 유압식 좌심실 보조장치에서 모터 전류 파형을 정보로 하여 작동기의 이완기 속도를 조절함으로써 좌심방으로부터 유입되는 혈류량을 조절하는 알고리즘을 개발하였다. 좌심실 보조장치(Left Ventricular Assist Device, LVAD)는 허혈성 심장질환 등으로 좌심실 의 혈액 박출 기능이 저하된 환자에게 시술하여 정상 상태의 심박출량을 유지할 수 있도록 하는 보조 혈액 박출 기능이이다. 전기 유압식 좌심실 보조장치에서는 혈액의 유입이 능동 적으로 이루어지므로, 좌심방 함몰로 인한 심근 손상 및 외부 공기 유입으로 인한 색전증을 방지하기 위해 유입혈류량을 현재 좌심방내의 상태에 따라 적절히 조절해 주어야 한다. 좌 심방 내의 혈액량 정도는 혈액을 유입해 내는 작동기의 이완기 동작 시에 소모되는 에너지 크기에 반영되고, 작동기를 구동하는 모터에 들어가는 전류의 크기는 작동기에 공급되는 에 너지에 비례하므로, 이전류 파형의 정보들을 통해 좌심방내의 상태를 추정해 볼 수 있다. 본 논문에서는 퍼지로직을 적용하여 모터 전류 파형의 정보들을 통해 좌심방 내의 상태를 추정 해 볼 수 있다. 본 논문에서는 퍼지로직을 적용하여 모터 전류 파형의 이상 유무를 판단한 뒤 에에 따라 작동기의 이완기 속도를 조절하는 알고리즘을 개발하여 모의순환장치 실험을 통해 그 실효성을 검증한 결과를 정리하였다.

  • PDF

좌심실보조장치의 혈액주머니용 코팅재료로서 PU-PEO-SO3의 in vivo 혈액적합성에 관한 연구 (In Vivo Blood Compatibility of PU-PEO-SO3 as Coating Material for Blood Sac of Left Ventricular Assist Device ( LVAD))

  • 한동근;김종원
    • 대한의용생체공학회:의공학회지
    • /
    • 제15권1호
    • /
    • pp.19-26
    • /
    • 1994
  • Sulfonated poly (ethyleneoxide)-grafted polyurethane (PU-PEO-$SO_3$) prepared by bulk modification was coated on a blood sac for electrohydraulic left ventricular assist device (ELVAD) implanted in dogs and its in vivo blood compatibility on shear stress was studied as compared with untreated Po. The effect of the wall shear stress on the protein adsorption unlike platelet adhesion is dependent on the surface characteristics of the material, although less proteins seem to be adsorbed in the region of the high shear stress. The thickness of total proteins adsorbed on PU-PEO-SOJ (400 ${\AA}$) by trans¬mission electron microscopy(TEM) was considerably lower than that of untreated PU(l,000~1,600 ${\AA}$), but PU-PEO-$SO_3$ showed high albumin adsorption, low fibrinogen and IgG adsorption, and low platelet adhesion as compared with untreated PU, suggesting that PU-PEO-$SO_3$ is more in vivo blood compatible. Therefore, it appears that such a blood compatible PU-PEO-$SO_3$ is useful for blood contacting biomaterials including artificial organs.

  • PDF

Centrifugal biomedicus pump의 임상 응용 (Clinical use of Centrifugal Biomedicus Pump)

  • 강면식
    • Journal of Chest Surgery
    • /
    • 제25권12호
    • /
    • pp.1550-1555
    • /
    • 1992
  • From June 1989 to July 1992, we used centrifugal Biomedicus pump[CBP] in 20 patients In 9 cases, CBP was used as ventricular assistance after heart surgery for those who could not be weaned off bypass even with intra-aortic balloon counter-pulsation and with maximal inotropic support In 8 patients, CBP was used as partial left heart bypass during repair of aortic aneurysms or congenital aortic anomalies. And in 3 patients, CBP was used as vena caval bypass during resection of renal cell carcinoma with tumor extension into the inferior vena cava. In 2 of 9 patients with ventricular assistance, they were weaned off the device successfully after 16 hours and 7 days respectively. But the patients died of intracranial hemorrhage and sepsis, 7 and 29 days after weaning from cardiac support, respectively. In all the patients who underwent aortic of vena caval surgery using CBP as shunt, there were no complications such as postoperative bleeding necessitating reoperation, renal failure or neurologic sequelae. In conclusion, the centrifugal type of ventricular assistance may be potentially life saving treatment modality in patients with severe postoperative low cardiac output syndrome. The CBP can be safely employed for resection of renal cell carcinoma with vena caval tumor extension and for repair of aortic aneurysms.

  • PDF

승모판 치환술후 발생한 좌심실 후벽 파열 (Posterior Left Ventricular Wall Rupture After Mitral Valve Replacement)

  • 강면식
    • Journal of Chest Surgery
    • /
    • 제25권11호
    • /
    • pp.1254-1260
    • /
    • 1992
  • Rupture of the posterior left ventricular wall following mitral valve replacement is a rare but fatal complication. Over a 10 year period from August 25 1980 to November 27 1990, we have experienced 6 such patients among 884 cases of mitral valve replacement with 4 deaths and 2 survivors. One patient had a type I rupture and another a type II rapture with the remaining four patients having suffered type III ruptures. All of the ruptures were dis covered intraoperatively enabling prompt reinstitution of the cardiopulmonary bypass and subsequent cardioplegic arrest prior to repair. Overzealous removal of calcified valve leaflets seemed to be responsible for the single type I rupture, and untethering of the so called ventricular loop appeared to be the main mechanism responsible for the type III ruptures. The single type II rupture that had occurred seemed to have been caused by inadvertent laceration of the papillary muscle with resultant rupture of the posterior LV wall at the base of the papillary muscle. Among the type III ruptures, 2 patients required intraaortic balloon pump[IABP] support only for mechanical assistance and 1 patient required both the IABP and the Biomedicus LV assist device for successfull weaning following repair of the LV rupture Another patient with a type II rupture also required the circulatory assistance of both the IABP and the bio-medicus LV assist device for weaning from the bypass. Attention to meticulous technical considerations such as avoiding over aggressive removal of heavily calcified valvular tissue, preservation of as much mural leaflet tissue and chordal stuctures as possible seemed helpful in preventing this catastrophic complication from occurring. Fusion and fibrous stricture of the chordal structures appeared particularly conducive to the type II ruptures as a result of the increased susceptibility to papillary injury during operation.

  • PDF

퍼지 subtractive 클러스터링 기법을 이용한 좌심실보조장치 모델링 및 흡입현상 검출 (Modeling of Left Ventricular Assist Device and Suction Detection Using Fuzzy Subtractive Clustering Method)

  • 박승규;최성진
    • 한국지능시스템학회논문지
    • /
    • 제22권4호
    • /
    • pp.500-506
    • /
    • 2012
  • 좌심실보조장치의 모델과 안전한 장치 구동을 위한 흡입현상 검출을 위한 방법을 제안한다. 좌심실보조장치인 축류혈액펌프는 심장에 문제가 있는 환자를 보조하기 위하여 사용되어 왔다. 축류혈액펌프는 비맥동성 펌프이며, 맥동성 펌프에 비하여 작은 크기와 효율성과 같은 장점이 있으나, 안전한 펌프 운전 조건을 결정하는 데 어려움이 있다. 축류혈액펌프는 정상상태와 흡입상태와 같은 상이한 펌프 동작 상태를 가지며, 이는 좌심실에서 흡입현상 발생여부에 좌우된다. 퍼지 subtractive 클러스터링 기법을 이용하여, 이와 같은 동작 특성을 가지는 축류혈액펌프 모델을 개발하며, 개발한 펌프 모델을 이용하여 흡입현상 발생 전후의 펌프 혈류량을 추정한다. 또한 퍼지 subtractive 클러스터링 기법을 이용하여 좌심실에서 흡입현상 발생여부를 감지할 수 있는 흡입현상 검출 모델을 개발한다.

대동맥 축착증 및 심한 대동맥 협착을 가진 저체중 신생아(2.4 kg)의 수술 전후 발생한 심실 기능 부전의 치료에 대한 양심실 보조 장치 적용 치험 예 (The Application of a Bi-ventricular Assist Device for a Low Weight (2.4 kg) Neonate with Coarctation of the Aorta and Critical Aortic Stenosis)

  • 곽재건;박천수;이창하;이철
    • Journal of Chest Surgery
    • /
    • 제43권3호
    • /
    • pp.304-307
    • /
    • 2010
  • 대동맥 축착증 및 심한 대동맥 협착을 가진 생후 5일의 환자가 대동맥 협착을 해결하려는 중재적 시술 도중 유도 카테터에 의한 우측 경동맥 손상으로 인한 출혈 및 심낭 내 탐폰으로 인한 심정지가 발생하여 심폐소생술 후 체외막성산화기 보조를 받았다. 환자의 체중은 2.4 kg이었다. 1일 후 수술적 완전 교정술을 시행하였으나, 수술 직후 심한 심기능 저하로 인하여 양심실 보조 장치로 순환 보조를 하였고, 3일 후 양심실 보조 장치 이탈에 성공하였다. 이후 환자는 일반적인 치료 후 특별한 문제없이 퇴원하였다.

소아환자에서 양심실 순환보조를 중개로 한 후 발생한 급성신부전 환자에서의 심장 이식수술 치험 1예 (A Case Report of Heart Transplantation Bridged by Bi-ventricular Assist Device in a Pediatric Patient of Prerenal Type ARF)

  • 나용준;곽재건;김진현;오세진;이재항;김웅한
    • Journal of Chest Surgery
    • /
    • 제39권11호
    • /
    • pp.854-857
    • /
    • 2006
  • 환자는 8세 여자 환자로 확장성 심근병증을 진단 받은 환자이다. 환자는 심부전으로 인하여 양심실 순환보조를 15일간 시행하였다. 15일 중 후반기 7일은 급성 신부전증이 발생하여 지속적 정맥-정맥간 혈액투석을 시행하였다. 이후 뇌사상태의 A형 혈액형을 가진 심장 공여자에게서 심장을 이식받아 심장이식술을 시행하였다. 면역 억제제는 급성 신부전증을 고려하여 사용하였다. 신부전 상해는 2주간 지속되었고, 심장 이식술 후 약 14일 후 배뇨가 시작되었다. 환자는 수술 후 12일째에 시행한 우심실 조직검사에서 특별한 거부반응의 증거가 없었으며, 면역요법 후 수술 후 52일째에 특별한 문제 없이 퇴원하였다. 환자는 술 후 약 14개월간 조직검사에서 면역 거부반응 없이 외래 경과관찰 중이다.

좌심실 보조장치를 이용한 전격성 심근염의 치료 - 1례 보고 - (Management of Acute Fulminant Myocarditis Using a Left Ventricular Assist Device - A case report -)

  • 강신광;박상순;나명훈;유재현;임승평;이영;성인환
    • Journal of Chest Surgery
    • /
    • 제34권6호
    • /
    • pp.490-493
    • /
    • 2001
  • 17세 여자 고등학교 학생이 전흉부 동통을 주소로 입원하였다. 약물 치료와 대동맥내 풍선 펌프에도 불구하고 폐부종과 순환 허탈이 악화되었다. 급성 전격성 심근염 추정 진단 하에 좌심실 보조장치를 설치하였다. 유입구 도관은 유방하 좌전개흉술로 좌심이를 통하여 좌심방에 삽입하였고, 좌심이의 일부를 조직검사를 위해 떼어냈다. 유출구 도관은 좌측 대퇴 동맥에 PTFE도관을 간치시켜 삽입하였다. 체외순환 158시간 후 심초음파에서 좌심실의 운동성이 거의 정상으로 회복되었고, 좌심실 보조장치를 성공적으로 이탈할 수 있었다. 면역화학 검사와 중화 항체 검사에서 콕사키바이러스가 확인되었다. 환자는 입원 23일 째 아무런 심부전 증상없이 퇴원하였다.

  • PDF

좌심실보조장치 수술 환자의 드레싱 방법에 따른 드라이브라인 감염 실태 (Driveline Infections Incidence According to Dressing Methods for Patients with Left Ventricular Assist Device Implantation)

  • 최남경;최수정;최지연;박선희
    • 임상간호연구
    • /
    • 제28권2호
    • /
    • pp.167-176
    • /
    • 2022
  • Purpose: Driveline infection (DLI) is one of the major adverse events of Left Ventricular Assist Device (LVAD). The purpose of this study was to explore the incidence of DLI according to the driveline dressing methods. Methods: This study was a retrospective cohort study that investigated the medical records of 75 patients who implanted LVAD from January 2015 to December 2020 at a hospital in Seoul, Korea. Traditionally, sandwich dressing method was applied until October 2019, after which newly winded dressing method was adopted for driveline dressing to LVAD patients. The outcome variables were compared between sandwich dressing method applied group (n=41) and winded dressing method applied group (n=34). The follow-up period for DLI was 1 year. Results: When compared participants' characteristics, there was no difference between the two groups, except the type of LVAD device. The incidence of DLI was 17.1% in sandwich dressing group, while no infection was found in winded dressing group (p=.011). Conclusion: Although there were difference in the LVAD devices, it is considered that winded dressing contributed to the reduction of DLI. Further research on standardized dressing methods was required for DLI prevention in Korea.