• Title/Summary/Keyword: ventricular assist

Search Result 134, Processing Time 0.031 seconds

Implementation of a Circuit for the Enhancement of Signal to Noise Ratios of Current Signal in a Artificial Heart (인공심장 전류 신호의 신호대 잡음비 개선을 위한 회로 구현)

  • Choi, J.H.;Lee, J.H.;Choi, W.W.;Ahn, J.M.;Kim, W.E.;Lee, J.J.;Om, K.S.;Choi, J.S.;Park, S.K.;Cho, Y.H.;Kim, H.C.;Min, B.G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.277-280
    • /
    • 1996
  • We have developed a ground-isolation circuit in order to reduce the noise of the internal controller system for the total artificial heart(TAH) and ventricular assist device(VAD). Using the ground-isolation technique, we could transmit the analog target signal to other pheriperal device including IBM PC via RS232C and polygraph, with no noise. Experimental results of VAD showed that there was less impulsive noise in current signal which caused in our previous conventional system. Therefore it could be proved that implementation of isolation technique is very effective to improve the signal to noise ratios of analog signal transmission for TAH or VAD.

  • PDF

Predictors of 30-Day Mortality and 90-Day Functional Recovery after Primary Intracerebral Hemorrhage : Hospital Based Multivariate Analysis in 585 Patients

  • Kim, Kyu-Hong
    • Journal of Korean Neurosurgical Society
    • /
    • v.45 no.6
    • /
    • pp.341-349
    • /
    • 2009
  • Objective : The purpose of this study was to identify independent predictors of mortality and functional recovery in patients with primary intracerebral hemorrhage (PICH) and to improve functional outcome in these patients. Methods : Data were collected retrospectively on 585 patients with supratentorial PICH admitted to the Stroke Unit at our hospital between 1st January 2004 and the 31st July 2008. Using multivariate logistic regression analysis, the associations between all selected variables and 30-day mortality and 90-day functional recoveries after PICH was evaluated. Results : Ninety-day functional recovery was achieved in 29.1% of the 585 patients and 30-day mortality in 15.9%. Age (OR=7.384, p=0.000), limb weakness (OR=6.927, p=0.000), and hematoma volume (OR=5.293, p=0.000) were found to be powerful predictors of 90-day functional recovery. Furthermore, initial consciousness (OR=3.013, p=0.014) hematoma location (lobar, OR=2.653, p=0.003), ventricular extension of blood (OR=2.077, p=0.013), leukocytosis (OR=2.048, p=0.008), alcohol intake (drinker, OR=1.927, p=0.023), and increased serum aminotransferase (OR=1.892, p=0.035) were found to be independent predictors of 90-day functional recovery after PICH. On the other hand, a pupillary abnormality (OR=4.532, p=0.000) and initial unconsciousness (OR=3.362, p=0.000) were found to be independent predictors of 30-day mortality after PICH. Conclusion : The predictors of mortality and functional recovery after PICH identified during this analysis may assist during clinical decision-making, when advising patients or family members about the prognosis of PICH and when planning intervention trials.

Early Outcomes of COVID-19 Lung Transplantation Recipients in Korea: A Single-Center Study

  • Shi A Kim;Jae Kwang Yun;Geun Dong Lee;Dong Kwan Kim;Sehoon Choi
    • Journal of Chest Surgery
    • /
    • v.56 no.1
    • /
    • pp.6-13
    • /
    • 2023
  • Background: Coronavirus disease 2019 (COVID-19) has been found to cause life-threatening respiratory failure, which can progress to irreversible lung damage. Lung transplantation can be a life-saving treatment in patients with terminal lung disease (e.g., acute respiratory distress syndrome caused by infection). This study aimed to present the clinical course and results after initial lung transplantation in patients with severe COVID-19 who did not recover even with optimal medical care. Methods: From August 2019 to February 2022, this study enrolled 10 patients with COVID-19 (5 men; median age, 55.7 years) who underwent lung transplantation at a single center in Korea. All patients' characteristics, clinical pathway, overall survival, complications, and operative data were collected and analyzed. Results: Veno-venous extracorporeal membrane oxygenation or an oxygenator in a right ventricular assist device circuit was applied to 90% of the patients, and the median length of extracorporeal life support before operation was 48.5 days. There were no cases of mortality after a median follow-up of 372.8 days (interquartile range, 262.25-489 days). The major complications included the requirement for postoperative extracorporeal membrane oxygenation support in 2 cases (20%), re-transplantation in 1 case (10%), and re-exploration due to bleeding in 2 cases (20%). During the follow-up period, 3 out of 10 patients died. Conclusion: Excellent early outcomes were observed for patients who underwent lung transplantation. Thus, lung transplantation can be an effective and feasible treatment for patients with end-stage lung disease caused by COVID-19.

Analysis of the Causes of and Risk Factors for Mortality in the Surgical Repair of Interrupted Aortic Arch (대동맥궁 단절증 수술 사망 원인과 위험인자 분석)

  • Kwak Jae Gun;Ban Ji Eun;Kim Woong-Han;Jin Sung Hoon;Kim Yong Jin;Rho Joon Ryang;Bae Eun Jung;Noh Chung Il;Yun Yong Soo;Lee Jeong Ryul
    • Journal of Chest Surgery
    • /
    • v.39 no.2 s.259
    • /
    • pp.99-105
    • /
    • 2006
  • Background: Interrupted aortic arch is a rare congenital heart anomaly which still shows high surgical mortality. In this study, we investigated the causes of and the risk factors for mortality to improve the surgical outcomes for this difficult disease entity. Material and Method: From 1984 to 2004, 42 patients diagnosed as IAA were reviewed retrospectively. Age, body weight at operation, preoperative diagnosis, preoperative PGE1 requirement, type of interrupted aortic arch, degree of left ventricular outflow stenosis, CPB time, and ACC time were the possible risk factors for mortality. Result: There were .14 hospital deaths. Preoperative use of PGE1, need for circulartory assist and aortic cross clamp time proved to be positive risk factors for mortality on univariate analysis. Preoperative left ventricular outflow stenosis was considered a risk factor for mortality but it did not show statistical significance (p-value=0.61). Causes of death included hypoxia due to pulmonary banding, left ventricular outtract stenosis, infection, mitral valve regurgitation, long cardiopulmonary bypass time and failure of coronary transfer failure in TGA patients. Conclusion: In this study, we demonstrated that surgical mortality is still high due to the risk factors including preoperative status and long operative time. However preoperative subaortic dimension was not related statistically to operative death statistically. Adequate preoperative management and short operation time are mandatory for better survival outcome.

The Usefulness of a Percutaneous Cardiopulmonary Support Device for the Treatment of Fulminant Myocarditis (전격성 심근염의 치료에 있어 경피적 순환 보조 장치의 유용성)

  • Lim, Juyoug;Jung, Sung Ho;Je, Hyoung-Gon;Lee, Taek Yeon;Choo, Suk Jung;Lee, Jae Won;Chung, Cheol Hyun
    • Journal of Chest Surgery
    • /
    • v.43 no.1
    • /
    • pp.20-24
    • /
    • 2010
  • Background: Fulminant myocarditis is a rare, but life threatening condition. Its prognosis is related with proper management in the acute phase. A cardiopulmonary support device can be very useful in this phase. We report on our experiences with managing acute fulminant myocarditis with a cardiopulmonary support (CPS) device. Material and Method: We reviewed retrospectively 9 patients who had a CPS device used for their fulminant myocarditis between September, 2006 and October, 2008. A Capiox emergency bypass system (Terumo Inc, Tokyo, Japan) was percutaneously inserted in all the patients. Upon implantation, all the patients were in cardiogenic shock because of ventricular arrhythmia or severe left ventricular dysfunction. The mean left ventricular ejection fraction (EF) was $20{\pm}6%$ according to transthoracic echocardiography. Result: 3 patients died despite CPS. The CPS was bridged to a transplanted heart in one patient. The rest were successfully explanted after a mean time of $107{\pm}70$ hours of running. The mean EF after discharge was $56{\pm}7%$ without dilated cardiomyopathy. Conclusion: Fulminant myocarditis can be fatal, but its prognosis is excellent if these patients receive proper, timely treatment. A cardiopulmonary support device can be very useful in this acute period. However, the implantation and management protocol of cardiopulmonary support are not yet settled. Further study is necessary to lower the complications of cardiopulmonary support for patients with fulminant myocarditis.

Short-term Mechanical Circulatory Support with Centrifugal Pump in Cardiac Arrest or Cardiogenic Shock - Report of 5 cases- (심정지 혹은 심인성 쇼크에서 원심성 펌프를 이용한 단기목표의 기계적 순환 보조)

  • 양희철;성기익;뱍계현;전태국;박표원;양지혁;이영탁
    • Journal of Chest Surgery
    • /
    • v.37 no.12
    • /
    • pp.1003-1009
    • /
    • 2004
  • Mechanical circulatory support (MCS) has been used for myocardium failure, but moreover, it may be essential for the life support in cardiac arrest or cardiogenic shock. Many commercial devices can be used effectively for the long-term support. However, there are some limitations in the aspects of the cost and technical support by production company. Short-term support with centrifugal type has been reported numerously with the purpose of bridging to heart transplantation or recovery. We successfully treated 5 patitents who were in the status of cardiogenic shock (n=3) or arrest (n=2) with the technique of extracorporeal life support system (ECLS) or left ventricular assist device (LVAD) using the centrifugal type pump. The MCS were performed emergently (n=2) under cardiac arrest caused by ischemic heart disease, and urgently (n=3) under cardiogenic shock with ischemic heart disease (n=1) or acute fulminant viral myocarditis (n=2). All patients were weaned from MCS. Complications related to the use of MCS were bleeding and acute renal failure, but there were no major complications related to femoral cannulations. Mechanical circulatory support may be essential for the life support and rescue in cardiac arrest or cardiogenic shock.

A Study of Electromagnetic Actuator for Electro-pneumatic Driven Ventricular Assist Device

  • Jung Min Woo;Hwang Chang Mo;Jeong Gi Seok;Kang Jung Soo;Ahn Chi Bum;Kim Kyung Hyun;Lee Jung Joo;Park Yong Doo;Sun Kyung
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.6
    • /
    • pp.393-398
    • /
    • 2005
  • An electromechanical type is the most useful mechanism in the various pumping mechanisms. It, however, requires a movement converting system including a ball screw, a helical cam, or a solenoid-beam spring, which makes the device complex and may lessen reliability. Thus, the authors have hypothesized that an electromagnetic actuator mechanism can eliminate the movement converting system and that thereby enhance the mechanical reliability and operative simplicity of an electro­pneumatic pump. The purpose of this study was to show a novel application of electromagnetic actuator mechanism in pulsatile pump and to provide preliminary data for further evaluations. The electromagnetic actuator consists of stators with a single winding excitation coil and movers with a high energy density neodymium-iron-boron permanent magnet. A 0.5mm diameter wire was used for the excitation coil, and 1000 turns were wound onto the stators core with parallel. A prototype of extracorporeal electro-pneumatic pump was constructed, and the pump performance tests were performed using a mock system to evaluate the efficiency of the electromagnetic actuator mechanism. When forward and backward electric currents were supplied to the excitation coil, the mover effectively moved back and forth. The nominal stroke length of the actuator was 10mm. The actuator dimension was 120mm in diameter and 65mm in height with a mass of 1.4kg. The prototype pump unit was 150mm in diameter, 150mm in thickness and 4.5kg in weight. The maximum force output was 70N at input current of 4.5A and the maximum pump rate was 150 beats per minute. The maximum output was 2.0 L/minute at a rate of 80bpm when the afterload was 100mmHg. The electromagnetic actuator mechanism was successfully applied to construct the prototype of extracorporeal electro­pneumatic pump. The authors provide the above results as a preliminary data for further studies.

In-Vitro Thrombosis Detection of Mechanical Valve using Artificial Neural Network (인공신경망을 이용한 기계식 판막의 생체외 모의 혈전현상 검출)

  • 이혁수;이상훈
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.4
    • /
    • pp.429-438
    • /
    • 1997
  • Mechanical valve is one of the most widely used implantable artificial organs of which the reliability is so important that its failure means the death of patient. Therefore early noninvasive detection is essentially required, though mechanical valve failure with thrombosis is the most common. The objective of this paper is to detect the thrombosis formation by spectral analysis and neural network. Using microphone and amplifier, we measured the sound from the mechanical valve which is attached to the pneumatic ventricular assist device. The sound was sampled by A/D converter(DaqBook 100) and the periodogram is the main algorithm for obtaining spectrum. We made the thrombosis models using pellethane and silicon and they are thrombosis model on the valvular disk, around the sewing ring and fibrous tissue growth across the orifice of valve. The performance of the measurment system was tested firstly using 1 KHz sinusoidal wave. The measurement system detected well 1KHz spectrum as expected. The spectrum of normal and 5 kinds of thrombotic valve were obtained and primary and secondary peak appeared in each spectrum waveform. We find that the secondary peak changes according to the thrombosis model. So to distinguish the secondary peak of normal and thrombotic valve quantatively, 3 layer back propagation neural network, which contains 7, 000 input node, 20 hidden layer and 1 output was employed The trained neural network can distinguish normal and valve with more than 90% probability. As a conclusion, the noninvasive monitoring of implanted mechanical valve is possible by analysing the acoustical spectrum using neural network algorithm and this method will be applied to the performance evaluation of other implantable artificial organs.

  • PDF

Impact of a Multidisciplinary Team Approach on Extracorporeal Circulatory Life Support-Bridged Heart Transplantation

  • Lee, Jae Jun;Kim, Young Su;Chung, Suryeun;Jeong, Dong Seop;Yang, Ji-Hyuk;Sung, Kiick;Kim, Wook Sung;Jun, Tae-Gook;Cho, Yang Hyun
    • Journal of Chest Surgery
    • /
    • v.54 no.2
    • /
    • pp.99-105
    • /
    • 2021
  • Background: The number of heart transplantations (HTx) is increasing annually. Due to advances in medical and surgical support, the outcomes of HTx are also improving. Extracorporeal circulatory life support (ECLS) provides patients with decompensated heart failure a chance to undergo HTx. A medical approach involving collaboration among experienced experts in different fields should improve the outcomes and prognosis of ECLS-bridged HTx. Methods: From December 2003 to December 2018, 1,465 patients received ECLS at Samsung Medical Center. We excluded patients who had not undergone HTx or underwent repeated transplantations. Patients younger than 18 years were excluded. We also excluded patients who received an implantable durable left ventricular assist device before HTx. In total, 91 patients were included in this study. A multidisciplinary team approach began in March 2013 at our hospital. We divided the patients into 2 groups depending on whether they were treated before or after implementation of the team approach. Results: The 30-day mortality rate was significantly higher in the pre-ECLS team group than in the post-ECLS team group (n=5, 18.5% vs. n=2, 3.1%; p=0.023). The 1-year survival rate was better in the post-ECLS team group than in the pre-ECLS team group (n=57, 89.1% vs. n=19, 70.4%; p=0.023). Conclusion: We found that implementing a multidisciplinary team approach improved the outcomes of ECLS-bridged HTx. Team-based care should be adapted at HTx centers that perform high-risk HTx.

Role and Clinical Importance of Progressive Changes in Echocardiographic Parameters in Predicting Outcomes in Patients With Hypertrophic Cardiomyopathy

  • Kyehwan Kim;Seung Do Lee;Hyo Jin Lee;Hangyul Kim;Hye Ree Kim;Yun Ho Cho;Jeong Yoon Jang;Min Gyu Kang;Jin-Sin Koh;Seok-Jae Hwang;Jin-Yong Hwang;Jeong Rang Park
    • Journal of Cardiovascular Imaging
    • /
    • v.31 no.2
    • /
    • pp.85-95
    • /
    • 2023
  • BACKGROUND: The prognostic utility of follow-up transthoracic echocardiography (FU-TTE) in patients with hypertrophic cardiomyopathy (HCM) is unclear, specifically in terms of whether changes in echocardiographic parameters in routine FU-TTE parameters are associated with cardiovascular outcomes. METHODS: From 2010 to 2017, 162 patients with HCM were retrospectively enrolled in this study. Using echocardiography, HCM was diagnosed based on morphological criteria. Patients with other diseases that cause cardiac hypertrophy were excluded. TTE parameters at baseline and FU were analyzed. FU-TTE was designated as the last recorded value in patients who did not develop any cardiovascular event or the latest exam before event development. Clinical outcomes were acute heart failure, cardiac death, arrhythmia, ischemic stroke, and cardiogenic syncope. RESULTS: Median interval between the baseline TTE and FU-TTE was 3.3 years. Median clinical FU duration was 4.7 years. Septal trans-mitral velocity/mitral annular tissue Doppler velocity (E/e'), tricuspid regurgitation velocity, left ventricular ejection fraction (LVEF), and left atrial volume index (LAVI) at baseline were recorded. LVEF, LAVI, and E/e' values were associated with poor outcomes. However, no delta values predicted HCM-related cardiovascular outcomes. Logistic regression models incorporating changes in TTE parameters had no significant findings. Baseline LAVI was the best predictor of a poor prognosis. In survival analysis, an already enlarged or increased size LAVI was associated with poorer clinical outcomes. CONCLUSIONS: Changes in echocardiographic parameters extracted from TTE did not assist in predicting clinical outcomes. Cross-sectionally evaluated TTE parameters were superior to changes in TTE parameters between baseline and FU at predicting cardiovascular events.