• Title/Summary/Keyword: ventilation threshold

Search Result 34, Processing Time 0.021 seconds

VOC/HAPs Emission Characteristics & Adsorption Evaluation for Paint Products in Busan Area (부산지역 페인트제조시설의 VOC/HAPs 배출특성 및 흡착능 평가)

  • Song, Bok-Joo;Lee, Seung-Min;Cho, Gab-Je;Cho, Jeong-Gu;You, Pyung-Jong;Kim, Gi-Gon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.5
    • /
    • pp.316-325
    • /
    • 2012
  • In this study, we suggested adequate control technology by analyzing emission process and main chemical of VOC/HAPs generated from four paint factories in Busan area. And we estimated whether Kapok fiber, which is a natural material, can be commercially used for an absorbent by testing adsorption ability. As a result of this sturdy, above 60% of VOC/HAPs was volatilized and dispersed inside the working place without conducting control system of facilities during manufacturing paints. Concentration profile of VOC/HAPs, which is volatile naturally outside the factories, is surveyed above 70% at Toluene, Ethylbenzene, and Xylene. And a result of evaluation of odor attribution level about the component whose Odor Threshold is known, it is estimated that major cause material of A, B, C factories is Toluene and that of D factory is m/p-Xylene. And that result presented design arguments such as facilities specifications, activated carbon filling volume, and replace cycle of activated carbon as control technology. Also, that result presented emission process improvement such as adsorption of central-controlled ventilation device, installation of inlet flenge, and potable cleaning process. The rate of pollutant adsorption of Kapok fiber, which is natural material, is indicated about 91.9%, 66.7%. That result validated the possibility as replacement of activated carbon.

A study on the management of harmful working environments for Increase of Labor productivity. (노동생산성 향상을 위한 유해작업환경관리에 관한 연구)

  • 조태웅;유익현;박성애
    • Journal of Environmental Health Sciences
    • /
    • v.3 no.1
    • /
    • pp.27-44
    • /
    • 1976
  • This study was carried out to evaluate the harmful factors in working environments and to investigate the labor productivity after improvement of environments, surveying 93 industrial establishments of 10 industries located in Youngdeungpo industrial area in Seoul. The results obtained were as follows: 1) The highest noise level of 125dB(A) was indicated at the rolling process of transport equipment manufacturing industry. 2) The best illumination level was shown in precise machinery industry and the worst was indicated in rubber products, metallic products and transport equipment manufacturing industries. 3) Thermal conditions were above threshold limit value (TLV) at more than two processes of all industries except printing industry. 4) The highest dust concentration was determined in textile and wearing manufacturing industry. 5) Organic solvents were detected at 52 processes in 93 industrial establishments and 33 processes of them showed higher than TLV. The results about harmful chemicals were as follows: a) sulfur dioxide ($SO_2$)was determined higher than TLV on welding process of metallic product manufacturing industry and heat treatment process of transport equipment manufacturing industry. b) Carbon monoxide (CO) concentration was 700ppm at heat treatment process of transport equipment manufacturing industry, indicating 14 times of TLV. c) vinylchloride concentration in the air of PVC raw material mixing process and PVC preparation process of chemical product manufacturing industry was determined higher than TLV. d) Hydrochloride (HCl) concentration in the air of wire expanding process of transport equipment manufacturing industry was determined higher than TLV. 7) Higher values of lead concentration than TLV were determined at lead welding metallic product manufacturing industry and type planting process of process of printing industry, $1.8mg/m^3$ and $0.3mg/m^3$ respectively. 9) 22, 968 of 52, 855 workers (i.e. 43.5%) in 93 industries were exposed to various harmful agents. 10) It was found that the improvement of illumination in electric apparatus manufacturing industry (from 20~40 lux to 420 lux) resulted in an increase in productivity of 6.5% per capita and a decrease in faulty products of 19%. 11) Improvement of environments using local exhaust ventilation system resulted in a decrease of harmful substances lower than TLV and an increase in productivity of 11.4%. 12) Improvement of shovelling tools based on ergonomics resulted in a reduction in energy expenditure of 25.3% and an increase in productivity of 32.2% per capita.

  • PDF

The Effects of High-intensity Interval Exercise and Moderate-intensity Continuous Exercise on Emotional Response and Neurotransmitters in Low-active Women (비활동성 여성의 고강도 인터벌 운동과, 중강도 지속적 운동이 감정적 반응과 신경전달물질에 미치는 영향)

  • Choi, Jaeil
    • 한국체육학회지인문사회과학편
    • /
    • v.58 no.4
    • /
    • pp.447-459
    • /
    • 2019
  • This study was conducted to investigate the differences between emotional responses and neurotransmitters in moderate-intensity continuous exercise (MICE) and high-intensity interval exercise (HIIE) in 30 low-active women. Both groups performed a designed acute treadmill exercise and repeated the same exercise three times at intervals of one week. MICE performed a 25-minute continuous exercise at 90% VT(ventilation threshold) after a 5-minute warm-up session at 50% VT and then cooled down for 5 minutes at 50% VT level. The HIIE was repeated 6 times for 2 minutes at 115% VT level, and the intermediate active recovery was repeated 4 times for 2 minutes at 85% VT level. The results of the statistical analysis are as follows. MICE was showed positive effect for feeling scale and PACES after exercise in the first experiment, but negative effect in the third experiment. Conversely, HIIE was showed negative effect for feeling scale and PACES after exercise in the first experiment, but positive effect in the third experiment. Neurotransmitters were significantly increased in all three groups after 10 minutes of exercise compared to before exercise. In summary, HIIE exercise may be a strategy to increase exercise compliance for low-active women.

Implication of Quantitative Culture of Bronchoalveolar Lavage Fluid in the Diagnosis of Ventilator Associated Pneumonia in Patients with Antimicrobial Therapy (항생제 사용 중 발생한 기계 호흡기 관련 폐렴에서 기관지 세포 세척술의 진단적 의미)

  • Chang, Yoon-Soo;Ahn, Chul-Min;Chung, Byung-Chun;Kim, Hyung-Jung;Kim, Seong-Kyu;Lee, Won-Yong;Shin, Jeung-Su
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.1
    • /
    • pp.72-81
    • /
    • 2000
  • Backgrounds : Authors evaluated the quantitative culture of bronchoalveolar lavage fluid(BALF) in patients who were being treated with antimicrobial agents and the characteristics of isolated microorganism. Method : A prospective study was done with 25 patients under mechanical ventilation and antimicrobial treatment in ICU and NCU of Yongdong Severance Hospital from Apr. to Sep. 1999. Patients were classified into two groups: control group (n=5) and patients with VAP (n=20). The threshold of quantitative culture of BAL fluid in the diagnosis of VAP was $10^4$ cfu/ml. Results : 1) In gram staining of BALF, one patient in the control group and four in the VAP group showed positive results. Quantitative culture of BALF showed no organisms in the patients in the control group and in 9 VAP patients. Therefore the overall sensitivity was 43.8%. 2) Frequency of isolated organisms cultured above diagnostic threshold was in the following order: E. cloaclae, S. aureus, K. pneumoniae, and A. baumani. S. aureus and Staphylococcus coagulase(-) were a11 resistant to oxacillin. Seven out of 10 isolated G (-) organisms were suspected to be organisms producing extended spectrum $\beta$-lactamase (ESBL). 3) The concurrence between gram staining of sputum aspiration and that of BALF was only in 1 case. And the concurrence of culture results was observed in 3 cases. Conclusion : The sensitivity of gram staining and quantitative culture of BALF from patients under antibiotic therapy and the concordance rate between conventional tracheal aspiration and BAL were low, facts which were important in interpretation the data. Since the frequency of drug resistance organisms was not different from that of foreign data, antibiotics must be prudently selected and used.

  • PDF