• Title/Summary/Keyword: ventilation system

Search Result 1,339, Processing Time 0.024 seconds

A Development of Coupled Simulation Tool to Evaluate Performance of Ventilation System (환기시스템의 성능평가를 위한 통합 시뮬레이션 Tool의 개발)

  • Cho Wang-Hee;Song Doo-Sam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.2
    • /
    • pp.112-121
    • /
    • 2006
  • To evaluate the performance of ventilation system properly, the correlations among the ventilation rate, indoor air-quality and cooling/heating load should be analysed. In this study, simulation tool to analyze the performance of ventilation system was developed. The simulation tool is based on the TRNSYS and some modules to calculate concentration of pollutants with the operation of ventilation system and to decide the signal of ventilation system were newly developed in this study. And these modules coupled with building load and heating/cooling simulation modules. To verify the validity of developed simulation tool, comparison study between simulation and field study were accomplished. As results, the simulation tool developed in this study can be used to predict the performance of ventilation system with accuracy.

Analysis on Ventilation Performance of Natural Ventilation Systems in Multi-Family Housing Using Blower Door Test (Blower Door Test를 이용한 공동주택 자연환기시스템의 환기성능 분석)

  • Kim, Min Seok;Auh, Jin Sun;Hong, Goopyo;Kim, Byungseon Sean
    • KIEAE Journal
    • /
    • v.16 no.6
    • /
    • pp.129-134
    • /
    • 2016
  • Today, natural ventilation systems are widely applied in multi-family housing. However, studies using the wind data trend line of the blower door test are insufficient. Purpose: Through this study, we will propose a computational method about ventilation performance of natural ventilation systems by conducting blower door test. Method: First, we sealed the gaps between the main systems including the natural ventilation system and conducted the blower door test. Next, the natural ventilation system was opened, the blower door test was conducted, and the difference in air flow rate between when closed and when opened was checked. Blower door test was carried out with a pressure difference of 50 Pa. Result: Therefore, the ventilation performance of the natural ventilation system was checked by drawing a trend line using the data to calculate the air flow rate at 2 Pa of the natural ventilation equipment standard pressure difference.

A NUMERICAL STUDY OF THE VENTILATION AND FIRE SIMULATION IN A ROAD TUNNEL (도로터널 환기/제연 시스템 시뮬레이션)

  • Park, Jong-Tack;Won, Chan-Shik;Hur, Nahm-Keon;Cha, Cheol-Hyun
    • Journal of computational fluids engineering
    • /
    • v.11 no.4 s.35
    • /
    • pp.20-25
    • /
    • 2006
  • In the present study, flow characteristics inside a road tunnel are simulated for the ventilation flows due to jet fan system and flows induces by the traffic. Traffic ventilation is numerically simulated by multiple reference frame. From the results of steady state simulation of tunnel ventilation, it is found that the proper ventilation is achieved by the designed jet fan system along with ventilating flow induced by the traffic. A transient simulation is also performed for the case of vehicle fire in the tunnel reversing the direction of rotation of some fans. The results suggest that the heat and smoke can be controlled by the proper changing of fan operation mode. The present results can be used to design proper ventilation system and effective smoke control system as well.

A Study on the Air Ventilation System in Apartment Houses as a Health Concept - focused on the air ventilation and pilotis - (공동주택에 건강개념인 통기시스템에 관한 연구 - 공기순환과 필로티를 중심으로 -)

  • Cho, Cheul Hee;Lee, Teuk Koo
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.10 no.1
    • /
    • pp.29-38
    • /
    • 2004
  • The purpose of this study is to analyze the air ventilation system in apartment houses focused on the air circulation and pilotis. The air ventilation system is used with the data which were obtained by the environmental health, urban climate, air pollution, ventilation path. The architectural element was pilotis concept connected with piloti ratio, piloti position and piloti type. The summaries of this study were as follows; 1) the well-being apartment concept, 2) the heat island phenomenon, 3) the oxygen density of air, 4) the definition of ventilation path, 5) the pilotis connected with residential environment improvement. In addition, the detailded case study to the air ventilation system in apartment houses be needed.

  • PDF

The Study of Jet Fan Control Logic for Longitudinal Ventilation in Road Tunnel (젯트팬 종류식 터널의 퍼지응용 제어로직에 관한 연구)

  • 유지오;남창호;신현준
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.8
    • /
    • pp.763-770
    • /
    • 2000
  • In tunnel ventilation, the Purpose of ventilation control is to keep the required pollution level with minimum consumption of energy But tunnel ventilation has large disturbances caused by discharge of pollutants, traffic forces especially strong for longitudinal ventilation. Hence in this paper, the tunnel ventilation control logic applying fuzzy control theories is proposed and the simulation program of tunnel ventilation control is developed. The characteristics of longitudinal ventilation with jet fans are estimated and the effect of the proposed tunnel ventilation control is verified by the simulation program.

  • PDF

The Performance Field-Application of Natural Ventilation System (자연환기시스템의 현장 적용성 평가-열환경,에너지부분)

  • Choi, Dong-Hyuk;Choi, Gyoung-Seok;Kang, Jae-Sik;Lee, Seung-Eon
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.689-694
    • /
    • 2009
  • On account of Indoor Air Quality(IAQ) deterioration by reason of high isulation and air tightness for energy saving, absence of energy efficiency ventilation system development that can be domestic existing window system, the cost increase and the energy addition loss by mechanical ventilation for IAQ improvement the ventilation obligation making design standard was prepared by a social and technical background and the necessity. In this study, open module type natural ventilation window system for energy saving included a fixed and continuous quantity ventilation was developed. The purpose that indoor thermal comfort environment evaluate of indoor resident.

  • PDF

Field Studies on the Improvement of Indoor Air Quality by Ventilator in Apartment Houses (공동주택용 환기장치의 실내공기질 개선효과에 대한 현장실험연구)

  • Sung, Ki-Chul;Chang, Hyun-Jae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.2
    • /
    • pp.202-211
    • /
    • 2007
  • Ventilation system is being recommended as an effective tool to improve indoor air quality (IAQ) in apartment houses. Recently, in Korea, apartment house suppliers must establish ventilation system in apartment houses in law. In this study, improvement of IAQ by establishing mechanical ventilation system at apartment house was investigated by mockup test. Seven apartment houses were arranged for the test and improvement of IAQ was examined under the various conditions of ventilation rates, ventilator type and duct works. The results of this study show that IAQ in the test houses which were established mechanical ventilation system was improved about from 30% to 40% compared with IAQ in the apartment house which was not established ventilation system. However, there were no apparent concentration differences between the cases of changing ventilation rates, ventilator types and ductworks.

Design of a Local Ventilation System in the Non-Standard Air Condition using the Spreadsheet Model (스프레드시트 모델을 이용한 비표준 공기상태에서의 국소환기시스템의 설계)

  • 조석호
    • Journal of Environmental Science International
    • /
    • v.6 no.6
    • /
    • pp.645-658
    • /
    • 1997
  • A study on ventilation design using the spreadsheet model is carried out to propose means of available design. A sample of complex ventilation system In the non-standard condition Is used to illustrate thins spreadsheet model. In developing the spreadsheet model, this study has attempted to it general by using computional equations and design parameters that can be readily applied to any spreadsheet software. Also, most design data is contained in the spreadsheet template. This template provides the same design information as the ACGIH worksheet, and operates Quickly and emclenuy, and is fiexible enough to use under different conditions. This spreadsheet model allows the ventilation engineer to design quickly and accurately the ventilation system, without spending too much effort In the design process. By storing on computer and diskette, the design data computed finally can be used as a permanent record of specific ventilation system, and because of finally to be able to design over and over again while making only slight changes to the Input data, the spreadsheet model is used availably to accomplish the design optimazation by redesign and troubleshooting by review from field measurements. Also, the spreadsheet model is available for designing ventilation system under different condition or evaluating existing system or design drawing, because changes In the layout or formulae can be readily made to fit the needs of the designer.

  • PDF

Application of Solar Chimney System for Natural Ventilation in Underground Space (지하공간의 자연환기를 위한 태양 굴뚝 시스템의 응용)

  • Jang, Hyang-In;Suh, Seung-Jik
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.2
    • /
    • pp.87-95
    • /
    • 2010
  • This study analyzed the performance of solar chimney system for natural ventilation in underground space. A mathematical model of the solar chimney was proposed in order to predict its performance under varying parameters and Korea climatic condition. Steady state heat transfer equations were set up using a energy balanced equations and solved using a inverse matrix method. Numerical simulation program to analyze system was developed by using MATLAB. As the results, the ventilation performance of the solar chimney was determined by the temperature difference of air channel and inlet, and the temperature difference was influenced by insolation, stack height and distance of air gab. Also the solar chimney system can provide $262.9m^3/h$ of annual average ventilation rate. Because seasonal differences of ventilation rate was calculated within 25%, the solar chimney system can be used for every season in Korea climatic condition. Through this study, performance of solar chimney system for natural ventilation was verified by numerical method. Consequently, the solar chimney system is proved to be effective device for natural ventilation utilizing at all times, and the additional studies should be made through the experimental method for imagineering and commercialization.

The Use of Demand Controlled Ventilation in Multi-Purposed Facility (수요기반 환기량 조절법 (DCV)의 다중이용시설 적용방안)

  • Jeong, Jae-Weon;No, Sang-Tae
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.111-116
    • /
    • 2008
  • The objective of this paper was to show the possibility of demand-controlled ventilation (DCV) using the current Korean ventilation standard for multi-purposed facilites. Two attractive DCV approaches; $CO_2$-DCV and RFID-DCV were applied to DCV simulations for a theoretical public assembly space served by a dedicated outdoor air system (DOAS) with enthalpy recovery device. A numerical model for predicting realtime occupant number, ventilation rate, and $CO_2$ concentration under given conditions was developed using a commercial equation solver program. It was found that the current ventilation standard causes unstable ventilation system control in DCV applications, especially under $CO_2$-DCV. It is because the ventilation rate (per person) used in Korea is the sum of the outdoor air required to remove or dilute air contaminants generated by both occupant and building itself, and not a pure function of occupant numbers. Finally, it makes DCV control unstable when ventilation flow is regulated only by the number of occupants. In order for solving this problem, current Korean ventilation standard was modified as a form of ASHRAE Standard 62.1-2007 showing good applicability to various DCV approaches. It was found that this modification enhances applicability of the current ventilation standard to DCV significantly.

  • PDF