분배계통에 따른 지하주차장 환기설비 성능의 예측

  • 김경환;이재헌;오명도;김종필
    • 설비공학논문집
    • /
    • 제13권10호
    • /
    • pp.982-992
    • /
    • 2001
  • In this paper, the performance of ventilation equipments in enclosed parking garages were investigated for several air distribution systems by numerical method. Air change effectiveness of the non-mixing system was 0.42. It meant that more supply air as much as the design supply air was needed to maintain good indoor air quality. In the high speed nozzle ventilating system which is most expensive one, air change effectiveness was 0.54. Therefore this system satisfied to ventilation design. In the jet fan ventilating systems, air change effectiveness for jet fan ventilating system-A with 18 jet fans and jet fan ventilating system-B with 6 jet fans in circulation mixing arrangement were 0.565 and 0.42 respectively. Jet fan ventilating system-C with 6 jet fans in transport mixing arrangement was 0.535. Jet fan ventilating system-A and jet fan ventilating system-C met the ventilation design. But velocity in jet fan ventilating system-A was over 2.0m/s which is inappropriate in human comfort. Therefore this system is not proper to ventilation. Jet fan ventilating system-C was the optimum one for enclosed parking garages among 5 systems examined in this paper.

  • PDF

지하 수처리시설 유지관리층 환기설비의 성능평가 (Evaluation of the Ventilation Efficiency in an Underground Sewage Disposal Plant)

  • 강한기;이재헌
    • 설비공학논문집
    • /
    • 제19권10호
    • /
    • pp.695-702
    • /
    • 2007
  • In this paper, the ventilation efficiencies of an underground sewage disposal plant were investigated for ventilating system without fan, ventilating system with eleven cross flow fans and ventilating system with sixteen cross flow fans by numerical method. It has been found that the air change effectiveness of the system without fan was predicted 0.44. It means that an additional ventilating equipment is needed to maintain good indoor air quality. For the ventilating system with sixteen cross flow fans, the air change effectiveness was predicted 0.55. The air change effectiveness of the ventilating system with eleven cross flow fans was predicted 0.51. It is known that the air change effectiveness above 0.5 is enough to eliminate pollutant and bad smell in the indoor. Therefore, it is recommended to select the ventilating system with eleven cross flow fans for the underground sewage disposal plant in an economic point of view.

T-103 훈련기의 환기와 난방 시스템 개선에 관한 연구 (A Design and Application of the Ventilating and Heating System of T-103 Trainer Aircraft for Improvement)

  • 정대한
    • 한국군사과학기술학회지
    • /
    • 제16권3호
    • /
    • pp.277-284
    • /
    • 2013
  • In this paper, the ventilating and heating system of T-103 trainer aircraft were investigated and redesigned to improve its poor performance. The ventilation system of the trainer was designed to increase the mass flow rate of fresh air by using air intake valves. The flow-in air through the air intake valve is supplied to the cabin by the ram effect of aircraft and the propeller. And the additional heating system was installed to improve the temperature of the cabin inside. The wasted heat from the exhaust gas of the engines was used as heat source of the additional heating system by installing an heat exchanger around the exhaust nozzle. The additional fresh air and the heated air enter the cabin via two ducts mounted under the instrument panel and behind the pedal in the cabin. The additional ventilating and heating system can be controlled by the first pilot and the secondary pilot individually using the control knob equipped separately. After mounting the additional ventilating and heating system, evaluations such as inspection of parts and component, ground run-up test, in-flight test, user test, etc. were conducted. The result of the tests was sufficient to meet the requirements of the manuals, and the pilots were satisfied with the additionally mounted systems.

미세 다공판을 이용한 환기팬 시스템의 소음저감 (Noise Reduction of a Ventilating Fan System using Micro-Perforated Panel)

  • 이종석;송화영;이동훈;권혁정;김동윤
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1209-1211
    • /
    • 2006
  • This paper introduces an experimental study for the noise reduction of a ventilating fan system. For the purpose of noise reduction, conventionally an absorptive duct silencer filled with a glass fiber has been utilized. However, a glass fiber has some disadvantages like hygiene and secondary pollution problems. In order to overcome these problems, in this paper, a perforated duct silencer has been applied to the ventilating fan system. For the designing of a perforated duct silencer, the transmission losses for various perforated panel systems are measured and compared with its noise reduction performance.

  • PDF

환기팬 시스템의 소음특성과 저감에 관한 실험적 연구 (An Experimental Study on the Noise Characteristics and Reduction of a Ventilating Fan System)

  • 김덕한;이동훈;권혁정;김동윤;이종석
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.500-505
    • /
    • 2005
  • This paper introduces an experimental study for the noise characteristics and reduction of a ventilating fan system. For the purpose of noise reduction of it, an absorptive duct silencer filled with a glass fiber has been conventionally utilized. However, a glass fiber has some disadvantages like hygiene and secondary pollution problems. In order to overcome these problems, in this paper, a perforated duct silencer has been applied to the ventilating fan system. For the designing of a perforated duct silencer, the transmission losses for various perforated panel systems are measured and compared with their sound absorption performances.

  • PDF

신뢰성 향상 기반의 송풍전자장치 자동검사 시스템 구현 (Implementation for Automatic Inspection System on Ventilating Electronic Device Based on Reliability Improvement)

  • 도남수;류광렬
    • 한국정보통신학회논문지
    • /
    • 제21권6호
    • /
    • pp.1155-1160
    • /
    • 2017
  • 본 연구는 신뢰성 향상 기반의 송풍전자장치 자동검사 시스템을 구현하기 위한 연구이다. 신뢰성향상을 위해 수동검사 시스템에서 자동검사 시스템은 전자제품 검사의 오류를 최소화한다. 송풍전자장치 자동화 검사 시스템은 제어시스템과 모니터링시스템으로 구성되어 되어 실시간으로 검사결과를 공유한다. 검사시스템의 신뢰성은 Gage R&R 분석기법을 적용하여 평가한다, 평가결과는 수동검사에 비해 풍압센서를 기반으로 검사속도 2배 이상, 측정오차 ${\pm}0.02V$, 판정 능력의 유효성 15%, 누락확률 17%, 허위경보확률 12% 등으로 향상되었다. 따라서 전자제품 자동검사 시스템은 제품 바코드와 연동시켜 데이터베이스화하면 효율적인 신뢰성 향상의 품질관리시스템으로 발전시킬 수 있다.

터널주행 고속전철의 환기시스템 제어 방법에 관한 연구 (A Study on the Control Method of Ventilating System for High Speed Train in a Tunnel)

  • 최영석
    • 설비공학논문집
    • /
    • 제13권3호
    • /
    • pp.184-193
    • /
    • 2001
  • The present study develops programs simulating the internal pressure change of cars due to the change of external pressure when trains run into or passing each other in a tunnel. A new continuous ventilating system control method has been developed in order to alleviate the aural discomfort of passengers riding a high speed train. This method is based on the change of the charged and discharged flow rate by detecting the air pressures generated outside and inside of the train. When the outside and inside pressure are detected, the speed of the charge or exhaust fans and also the valve opening ratios are changed. The elementary performance of the system is checked using dta of the TGV-K high speed train at a speed of 300km/h. Moreover, applicability of the system to the Koran high speed train at a speed of 350 km/h is ascertained by simulation and its effectiveness as a means to alleviate the ear pains is confirmed. This application of the system to the Korean high speed vehicles running in the speed range of 350km/h is considered to have good prospect.

  • PDF

도로터널에서의 화재환기 설계에 관한 연구 (A Study on Fire ventilation design of road tunnel)

  • 김명배;최병일;최준석;한용식
    • 한국터널지하공간학회 논문집
    • /
    • 제6권2호
    • /
    • pp.129-139
    • /
    • 2004
  • 터널의 환기설계에 관련하여 종류식과 횡류식의 환기용량의 산정을 위해서 필요한 제반 가정들을 검토하였고, 종류식 설계에서의 최종 값인 임계유속 산정을 위한 몇 가지의 공식을 분석하였다. 이를 토대로 특정 공식을 개선하기 위한 방안을 실험결과를 토대로 제시하였다. 횡류식 설계에서 국제적으로 사용되고 있는 용량산정에 관한 지침은 화재공학적 의미가 전혀 없으며 관행적으로 적용되어 온 것임을 알 수 있었다. 뿐만 아니라 기존의 횡류식 환기설계에는 설계개념조차 명확하지 않음을 입증하였다. 즉 횡류식 시스템에서는 종류식에서의 "연기의 역류 방지를 위한 최소 유속의 유지"라는 개념조차 없이 환기용량이 결정되어 왔으며, 이것은 터널의 화재환기가 오염물질의 환기로부터 시작되어 정확한 화재공학적 분석이 결여되었기 때문이다. 이러한 문제를 해결하기 위한 시도로 횡류식 환기의 설계개념으로서 연기전파거리와 연기축적을 제안하였다. 축소모델 터널을 이용하여 연기전파거리에 관한 실험결과를 제시하였고, 이를 이용하여 기존의 관행대로 설계된 유럽의 터널들에 적용하였을 때 안전성에 문제가 있음을 보였다.

  • PDF

환기용 덕트내의 전달소음 특성에 관한 연구 (A Study on the Transmitted Noise Characteristics through the Ventilating Duct)

  • 최한림;김경환;최호선;오세기;정백영
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.376-380
    • /
    • 2009
  • The transmission noise characteristics through the ventilating duct was conducted numerically using SYSNOISE. A ventilating system is usually composed of mufflers for preventing noise transmission from the ventilator into indoors through the ducts and distributors for transferring air to or from each room. The transmitted noise characteristics of distributors which have different branch angles and of mufflers having different shapes were analyzed numerically. New duct element combining a muffler and a T-shaped distributor was developed for better noise reduction in this paper. New element's performance was shown numerically.

  • PDF

냉난방 시스템의 이중선형 시스템에 관한 제어기 설계 (A Controller Design of the Bilinear System for HVAC(Heating, Ventilating and Air-conditioning) System)

  • 이정석;강민수;김명호;이기서
    • 한국철도학회논문집
    • /
    • 제3권4호
    • /
    • pp.177-184
    • /
    • 2000
  • In this paper, a HVAC controller which has a bilinear system is designed to control the air temperature in building room and a saving of energy on the HVAC system. For modeling of the HVAC bilinear system, AHU(Air Handling Unit) is modeled on the control of inside-outside air flow using three dampers in a duct. A heat exchanger and the single room are also modeled by the energy conservation law. Under the modeling of the HVAC bilinear system, the control's law of the bilinear HVAC system is derived by Lyapunov's non-linear theory and Deress's the linear feedback laws for bilinear system. In this paper it was proved that the controller of the HVAC bilinear system is able to control the air temperature with a disturbance in order to get a target of temperature in the building room by the computer simulation when the control inputs regulate the air flow rate and a capacity of the heat exchanger.

  • PDF