• Title/Summary/Keyword: venous

Search Result 1,300, Processing Time 0.04 seconds

Dorsalis Pedis Tendocutaneous Delayed Arterialized Venous Flap in Hand Reconstruction (지연처치후 동맥화된 족배 정맥 건피판을 이용한 수부의 재건)

  • Cho, Byung-Chae;Lee, Dong-Hoon
    • Archives of Reconstructive Microsurgery
    • /
    • v.8 no.1
    • /
    • pp.56-63
    • /
    • 1999
  • We report two patients whose acute soft tissue and tendon defects in the hand were treated by the dorsalis pedis tendocutaneous delayed arterialized venous flap between 1994 and 1997. The surviving surface area was 100% in both patients. The flap size was $10{\times}10cm\;and\;6{\times}6cm$. At two weeks postoperatively, active flextion and passive extension commenced, and progressive resistance exercises were performed for an additional 5 weeks. Flaps showed a similar color match and skin texture compared with the normal skin of the hand. Advantages of the tendocutaneous delayed arterialized venous flap are developing a larger flap than can be obtained with pure venous flap or arterialized venous flap, increasing survival rate of the arterialized venous flap which permits using a composite flap, preservation of main artery of the donor site, taking thin non-bulky tissue and easy elevation without deep dissection. The disadvantages are the requirement of a two stage operation, donor site scarring and weak extension of the toe.

  • PDF

Cardiac Performance of Turtle Heart in Various pH of Perfusate (자라에서 본 관류액(灌流液) pH와 심장박출량(心臟搏出量))

  • Yang, Il-Suk
    • The Korean Journal of Physiology
    • /
    • v.9 no.1
    • /
    • pp.69-76
    • /
    • 1975
  • Cardiac performances were analyzed in intact turtle heart(Amyda japonica), perfusing with turtle Ringer-Locke's solution containing various hydrogen ion concentration, at several levels of arterial and venous pressure. 1. Ventricular work increased when venous pressure, or venous filling pressure increased, and also increased when arterial pressure increased. 2. The higher the arterial pressure, the lower the cardiac to output, for arterial pressure is the resistance to the ventricular blood flow. On the other hand, in specific arterial pressure, cardiac output was proportional to the venous filling pressure. 3. Heart rates did not change significantly during the perfusion with Ringel· solution of various pH. 4. In the heart Perfused with Ringer solution of various pH, ventricular work was the highest at PH 7.6 (at 6 $cmH_2O$ arterial pressure and 8 $cmH_2O$ venous pressure, the ventricular work was 63.09m$\cdot$cm). However, within the range of pH $7.1{\sim}7.6$, there were no significant changes in cardiac output and ventricular work. Below the level of pH 7.0, ventricular work decreased to less than 56% of maximium value (at $6cmH_2O$ arterial pressure and $8cmH_2O$ venous Pressure, ventricular work was 36.0$gm{\cdot}$ at pH 7.0). At pH 7.7 ventricular work decreased to less than 48% of maximum value (ventricular work: 30.0 $gm{\cdot}$). The nature of the cardiac performance at the various arterial and venous pressures was similar to that of normal heart. 5. Turtle heart seemed to be relatively insensitive to acid-base disturbances. The mechanism of negative inotropic effect of hydrogen ion was discussed.

  • PDF

THE USE OF AUTOLOGOUS VENOUS BLOOD FOR MAXILLARY SINUS FLOOR AUGMENTATION IN CONJUNCTION WITH THE SINUS MEMBRANE ELEVATION : AN EXPERIMENTAL STUDY (상악동 점막 거상 술식에서 자가 정맥 혈액의 사용이 상악동 저 증강에 미치는 영향)

  • Kim, Ha-Rang;Mo, Dong-Yub;Lee, Chun-Ui;Yoo, Jae-Ha;Choi, Byung-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.5
    • /
    • pp.346-352
    • /
    • 2009
  • There have been reports of successful bone formation with sinus floor elevation by simply elevating the maxillary sinus membrane and filling the sinus cavity below the lifted sinus membrane with a blood clot. But, in a review of the current literature, we found no animal study that substantiated blood clot's ability in this respect. The aim of this study was to investigate the effect of the method of maxillary sinus floor augmentation using the patient's own venous blood in conjunction with a sinus membrane elevation procedure. An implant was placed bilaterally in the maxillary sinus of six adult mongrel dogs so that it protruded 8 mm into the maxillary sinus after sinus membrane elevation. On one side of the maxillary sinus, the resultant space between the membrane and the sinus floor was filled with autologous venous blood retrieved from the dog. On the opposite side, the maxillary sinus was left untreated as a control. The implants were left in place for six months. The mean height of the newly formed bone in the sinus was 3.7 mm on the side without venous blood and 3.5 mm on the side with venous blood (p>0.05). There was no difference between the two sides regarding new bone height in the sinus. Our results indicate that filling the space between the lifted sinus membrane and the sinus floor with venous blood has no effect on bone formation around implants placed in the maxillary sinus cavity.

Adaptation and Effects of the Evidence-based IPC Nursing Protocol on Prevention of Postoperative Venous Thromboembolism (외과적 수술 후 정맥혈전색전증 예방을 위한 근거기반 IPC(Intermittent Pneumatic Compression) 간호프로토콜의 수용개작 및 효과)

  • Kim, Nam Yong;Kim, Eun A;Sim, Jae Yeun;Jung, Soon Hee;Kim, Hye Young;Jang, Eun Hee;Shin, Jee Hye
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.23 no.1
    • /
    • pp.63-75
    • /
    • 2017
  • Purpose: This study was conducted to adapt the standardized evidence-based nursing protocol using the IPC (intermittent pneumatic compression) intervention to prevent venous thromboembolism in surgical patients. Further, an investigation was done to measure knowledge on prevention of venous thromboembolism, surrogate incidence of venous thromboembolism and to assess IPC compliance in the study patients compared with those in surgical patients who underwent IPC intervention due to previous clinical experience. Methods: An analysis was done of the nine modules suggested by National Evidence-based Healthcare Collaborating Agency (NECA) in the adaptation manual of the clinical practice guideline for protocol adaptation. A nonequivalent control group post test design as a quasi-experiment was used to verify the effect of the IPC protocol. Results: There was a significant difference in knowledge of prevention of venous thromboembolism, IPC application time after intervention and the number of IPC applications between the experimental group (n=50) using the IPC nursing protocol and the control group (n=49). However, the symptoms of deep vein thrombosis and pulmonary thromboembolism were not observed in either the experimental group or the control group after the intervention. Conclusion: Results confirm that the standardized IPC nursing protocol provides effective intervention to prevent venous thromboembolism in surgical patients.

Impact of Complex Hemodynamics to the Management of ArterioVenous(AV) Fistula (동정맥루의 복합성 혈류학 소견이 그 관리에 미치는 영향)

  • Lee Byung-Boons
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.9-10
    • /
    • 2002
  • Human circulatory system between heart and tissue is not directly connected in normal condition but mandatory to go through the capillary system in order to fulfill its physiologic aim to deliver oxygen and nutrients, etc. to the tissue and retrieve used blood together with waste products from the tissue properly. When abnormal connection between arterial and venous system (AV fistula), these two circulatory systems respond differently to the hemodynamic impact of this abnormal connection between high pressure (artery) and low pressure (vein) system. Depending upon the location and/or degree (e.g. size and flow) of fistulous condition, each circulatory system exerts different compensatory hemodynamic response to this newly developed abnormal inter-relationship between two systems in order to minimize its hemodynamic impact to own system of different hemodynamic characteristics. Pump action of the heart can assist the failing arterial system directly to maintain arterial circulation against newly established low peripheral resistance by the AV fistula during the compensation period, while it affects venous system in negative way with increased venous loading. However, the negative impact of increased heart action to the venous system is partly compensated by the lymphatic system which is the third circulatory system to assist venous system independently with different hemodynamics. The lymphatic system with own unique Iymphodynamics based on peristaltic circulation from low resistance to high resistance condition, also increases its circulation to assist the compensation of overloaded venous system. Once these compensation mechanisms should fail to fight to newly established hemodynamic condition due to this abnormal AV connection, each system start to show different physiologic ${\underline{de}compensation}$ including heart and lymphatic system. The vicious cycle of decompensation between arterial and vein, two circulatory system affecting each other by mutually negative way steadily progresses to show series of hemodynamic change throughout entire circulation system altogether including heart. Clinical outcome of AV fistula from the compensated status to decompensated status is closely affected by various biological and mechanical factors to make the hemodynmic status more complicated. Proper understanding of these crucial biomechanical factors iii particular on hemodyanmic point of view is mandatory for the advanced assessment of biomechanical impact of AV fistula, since this new advanced concept of AY fistula based on blomechanical information will be able to improve clinical control of the complicated AV fistula, either congenital or acquired.

  • PDF

Reconstruction of the Soft Tissue Defect of the Lower Leg by Distally Based Superficial Sural Artery Fasciocutaneous Island Flap Using Supercharged Vein (원위기저 도서형 천비복동맥 근막피판으로 하지 재건 시 과급정맥문합의 이용)

  • Ha, Young In;Choi, Hwan Jun;Choi, Chang Yong;Kim, Yong Bae
    • Archives of Plastic Surgery
    • /
    • v.35 no.2
    • /
    • pp.208-213
    • /
    • 2008
  • Purpose: Distally based superficial sural artery island flap has some disadvantages such as postoperative flap edema, congestion, and partial necrosis of the flap margin. Venous congestion is an area of considerable concern in distally based superficial sural artery fasciocutaneous flap and is one of the main reasons for failure, particularly when a large flap is needed. However, we could decrease these disadvantages by means of venous superdrainage. Methods: From June of 2006 to June of 2007, a total of two patients with soft tissue defects of lower one third of the leg underwent venous supercharging distally based superficial sural artery island flap transfer. The distal pivot point of this flap was designed at septocutaneous perforator from the peroneal artery of the posterolateral septum, which was 5 cm above the tip of the lateral malleolus. Briefly, this technique is performed by anastomosing the proximal end of the lesser saphenous vein and collateral vein to any vein in the area of the recipient defect site. Results: No venous congestion was noted in any of the two cases. No other recipient or donor-site complications were observed, except for minor wound dehiscence in one case. In 3 to 6 months follow-up, patients had minor complaints about lack of sensation in the lateral dorsal foot. Conclusion: The peroneal artery perforator is predictable and reliable for the design of a distally based superficial sural artery island flap. Elevation of the venous supercharging flap is safe, easy, and less time consuming. In conclusion, the venous supercharging distally based superficial sural artery island flap offers an alterative to free tissue transfer for reconstruction of the lower extremity.

Reconstruction of the Soft Tissue Defect of the Finger Using Digital Island Flap with Supercharged Vein (손가락섬피판으로 손가락 연조직 재건시 과급정맥문합)

  • Choi, Hwan Jun;Kim, Nam Joong;Choi, Chang Yong
    • Archives of Plastic Surgery
    • /
    • v.36 no.2
    • /
    • pp.153-160
    • /
    • 2009
  • Purpose: The heterodigital or homodigital artery island flap is a popular method of reconstruction for finger defects. Sometimes, digital artery island flap has some disadvantages such as postoperative flap edema, congestion, and partial necrosis of the flap margin. However, we could decrease these disadvantages by means of venous superdrainage. The aim of this study is to report usefulness and postoperative results of venous supercharging digital artery island flaps for finger reconstruction. Methods: From March of 2005 to March of 2008, a total of eight patients with soft tissue defects of the finger underwent venous supercharging digital island flap transfer. Briefly, the flap is harvested along with dorsal vein that is then anastomosed to a recipient vein in an end - to - end fashion, after flap transfer and insetting. Using this technique, eight patients were operated on, ranging in age 23 to 52 years. Results: All the flaps survived with a success rate of 100 percent, thus fully satisfying the reconstructive requirements. No postoperative flap congestion was recognized, obviating the need to take any measures for venous engorgement, such as suture removal. Among 8 cases, it was possible to make an long - term and follow - up observation more than 6 months. In these cases, the fact that light touches and temperature sensations can be detected in all the flaps. Cold intolerance and hyperesthesia were not seen in our series. Conclusion: Providing good harmony with conventional methods and microsurgery, inclusion of a vein with the heterodigital and homodigital artery island flap allows a more reliable and safer reconstructive choice for finger defects. The venous supercharged island flap is a reliable flap with a consistent arterial structure, and with its augmented venous drainage, it is more reliable, providing single - stage reconstruction of adjacent finger defects, including the fingertip.

Reconstruction of the Defects of the Hands with Arterialized Venous Free Flap (유리 동맥화 정맥 피판을 이용한 수부 결손의 재건)

  • Kim, Joo-Sung;Kim, Jin-Ho
    • Archives of Reconstructive Microsurgery
    • /
    • v.8 no.2
    • /
    • pp.139-148
    • /
    • 1999
  • Since Nakayama's first report about venous flap, many experimental and clinical studies were done about this new type of flap. And due to its various benefits, its applications as arterialized venous free flap type have increased recently. In this study we have attempted to reconstruct composite of defects of the hand with new modification of arterialized venous free flap and simultaneous reconstruction of skin, nerve, tendon were performed successfully. From 1994 to 1999, the defects of the hands in 35 patients were reconstructed with various modifications of arterialized venous free flaps. The range of age was from 19 to 55 years and size of flap ranged from $1{\times}2cm\;to\;14{\times}9cm$. Among them, 12 cases of flap over 20cm in size were included. Indications of flaps were as follows: resurfacing of the defects of the skin (9 cases), simultaneous reconstruction of extensor, skin and digital nerve(2 cases), reconstruction of the skin with extensor(5 cases), as a flap-through type vascular reconstruction(6 cases), for digital nerve reconstruction(2 cases), contracture release(3 cases), and finger tip reconstruction(9 cases). All of the cases except one survived with marginal skin necrosis less than 10%. And relatively large flaps over 20cm in size successfully survived without any delay procedures. Composite reconstructions including tendon and nerve were successful with new modifications of this flap. Arterialized venous free flap is one of the useful procedure in reconstruction of the hand because it has many advantages such as non-bulky and good quality of flap, variable length of pedicle, preservation of major vascular pedicle, less operation time, single operative field and in addition possibility of various modifications.

  • PDF

Levoatriocardinal Vein Combined with Pulmonary Venous Varix Mimicking Arteriovenous Malformations: A Case Report (동정맥기형으로 오인되었던 폐정맥정맥류를 동반한 Levoatriocardinal 정맥: 증례 보고)

  • Joo Hee Jeun;Eun-Ju Kang;Jeong-Hyun Jo;Ki-Nam Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.2
    • /
    • pp.440-446
    • /
    • 2021
  • The levoatriocardinal vein is an uncommon pulmonary venous abnormality that connects the left atrium or pulmonary vein with the systemic vein. It is distinct from partial anomalous pulmonary venous return in that the former forms a connection with the left atrium through the normal pulmonary vein whereas the latter involves pulmonary venous drainage to the systemic vein. Herein, we describe a case of the levoatriocardinal vein initially misdiagnosed as a pulmonary arteriovenous malformation using chest radiography and chest CT. The levoatriocardinal vein combined with pulmonary venous varix was confirmed using pulmonary angiography. To the best of our knowledge, this unusual coexistence of the levoatriocardinal vein and pulmonary venous varix has not been reported in English literature.

Gastric salvage after venous congestion during major pancreatic resections: A series of three cases

  • Ravi Chandra Reddy;Vikram Chaudhari;Amit Chopde;Abhishek Mitra;Dushyant Jaiswal;Shailesh V. Shrikhande;Manish S. Bhandare
    • Annals of Hepato-Biliary-Pancreatic Surgery
    • /
    • v.28 no.1
    • /
    • pp.99-103
    • /
    • 2024
  • Pancreatic resections, depending on the location of the tumor, usually require division of the vasculature of either the distal or proximal part of the stomach. In certain situations, such as total pancreatectomy and/or with splenic vein occlusion, viability of the stomach may be threatened due to inadequate venous drainage. We discuss three cases of complex pancreatic surgeries performed for carcinoma of the pancreas at a tertiary care center in India, wherein the stomach was salvaged by reimplanting the veins in two patients and preserving the only draining collateral in one case after the gastric venous drainage was compromised. The perioperative and postoperative course in these patients and the complications were analyzed. None of these 3 patients developed any complication related to gastric venous congestion, and additional gastrectomy was avoided in all these patients. Re-establishment of the Gastric venous outflow after extensive pancreatic resections helps to avoid additional gastric resection secondary to venous congestive changes.