• Title/Summary/Keyword: vault

Search Result 218, Processing Time 0.021 seconds

A STUDY ON THE MAXILLARY DENIAL ARCH AND PALATAL VAULT WITH MALOCCULSIONS (부정교합자의 상악치열궁 및 구개에 관한 연구)

  • Kim, Choong Bae
    • The korean journal of orthodontics
    • /
    • v.10 no.1
    • /
    • pp.45-53
    • /
    • 1980
  • This study was based on the study models of 32 subjects with normal occlusion, 40 with Class I malocclusion, 32 with Class II, Division 1 malocclusion and 38 with Class III malocclusion, aged 12 to 20 years (mean age 16.4 years). The purpose of present study was to define the difference between normal and malocclusion groups in maxillary dental arch and palate. On the basis of findings of this study, the following results were obtained. 1. The intermolar widths and the intercanine widths in Class II, Div. 1 malocclusion group were smaller than in normal occlusion group significantly. 2. The arch lengths measured in both Class I and Class II, Div.1 malocclusion groups were larger than in normal occlusion group. 3. The palates in Class I and Class II, Div. 1 malocclusion groups were longer and narrower than in normal occlusion, but the palates in Class III malocclusion group were shorter than in normal occlusion group significantly. 4. The palatal depths measured at level 1 in Class III malocclusion group were significantly higher than in normal occlusion and in Class II, Div. 1 group they were significantly higher than in normal occlusion at level 2 and 3. 5. The measurements of palatal areas at various levels showed no significant difference between malocclusion and normal occlusion groups. 6. The palatal indies 1 (palatal length / palatal width) measured in both Class I and Class II, Div. 1 malocclusion groups were significantly greater than in normal occlusion and the palatal indice 2 (palatal depth at level 1/palatal width) measured in all malocclusion groups are greater than in normal occlusion. 7. It was determined from findings of this study that the measurements of maxillary dental arch and palate were influenced to a considerable extent by the molar relationship.

  • PDF

Craniosynostosis Occurring between Siblings (남매간에 발생한 두개골조기유합증)

  • Choi, Jeong-Hwan;Kim, Myung-Hoon;Kim, Min-Su;Jung, Gyu-Yong;Lee, Keun-Cheol;Kim, Seok-Kwun
    • Archives of Craniofacial Surgery
    • /
    • v.14 no.2
    • /
    • pp.115-118
    • /
    • 2013
  • Craniosynostosis is a congenital anomaly in which cranial sutures close prematurely and restrict skull growth. In this paper, the case of two siblings, a male and a female, who were both diagnosed as craniosynostosis is reported. They underwent corrective osteotomy for cranial vault remodeling. A 22-month-old female infant who was brought to the department of plastic and reconstructive surgery of the authors' hospital was diagnosed with plagiocephaly. At the same time, her 7-month-old brother was diagnosed with brachycephaly. In the case of the female infant, corrective coronal osteotomy and supraorbital bar advancement were performed. Her brother underwent frontal advancement osteotomy using Tessier's tongue in the groove procedure. After the correction of the craniosynostosis, the two patients recovered in several days later, and the results were good in both cases cosmetically and functionally. They showed normal head circumference increasing curves and no symptom of functional disorder in their last follow-up. Isolated or nonsyndromic craniosynostosis is sporadic but mostly autosomal dominant. This paper presents a case of craniosynostosis with a genetic tendency; and although it occurred between siblings, the affected lesions differed. Thus, appropriate diagnosis and management in patients are needed.

MULTIDISCIPLINARY CARE OF FREEMAN SHELDON SYNDROME (Freeman-Sheldon Syndrome의 치료에 대한 고찰)

  • Kim, Ji-Hun;Lee, Jeong-Sub;Chang, Cherry
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.4
    • /
    • pp.545-550
    • /
    • 2010
  • Freeman-Sheldon Syndrome (FSS, also known as "Whistling Face Syndrome") is a rare genetic condition which characteristically includes a small "whistling" mouth, a flat mask-like face, club feet, joint contractures usually involving the fingers and hands, and under-development of the cartilage of the nose. Intelligence is usually normal. Most of the features of this syndrome are due to muscle weakness. The patient, 11 years old boy was consulted from pediatrics to pediatric dentistry due to dental management. After clinical & radiographic examinations, severe multiple problems were found. Dental problems were microsomia(whistling mouth) & micrognathia, perioral muscle contracture, restricted mouth opening, poor oral hygiene & care, generalized dental caries, high palatal vault, severe malocclusion & crowding. And Orthopedic problems, ophthalmic & respiratory, anesthetic problems were found. Then He also had psychiatric problem, hospital(dental) phobia due to previous medical history(frequent hospitalization). And he had genital problem, cryptochidism, too. Due to these intricate problems, he suffered with feeding, swallowing difficulties and showed growth retardation. For enhancing patient's oral health, pediatric dentist, orthodontist, oral surgeon, pediatrician, psychiatrist, orthopedist, they all agree with early, cautious intervention and treatment. So, he has been treated by multidisciplinary care, now he is recovering general health maintenance.

Neural Network Model for Partial Discharge Pattern Analysis of XLPE/EPR Interface (XLPE/EPR 계면의 부분방전 패턴 분석을 위한 신경망 모형)

  • Cho Kyung-Soon
    • Journal of the Korea Computer Industry Society
    • /
    • v.6 no.2
    • /
    • pp.279-286
    • /
    • 2005
  • The prefabricated type used generally in Korea to join cable runs on new installations or to repair broken Cable runs on existing installations, because installation is very simple and save time. This type is a permanent, shielded and submersible cable joint for direct burial or vault application. It confirms to the requirements of IEEE std. 404-1993 by factory testing, but many problems of insulated cable systems are caused by internal defects of the joint part which have to be mounted ensile. Faults arise from impurities or voids. A suitable solution for a monitoring of cable joints during the after-laying test and service is partial discharge detection. <중략> $\Phi-q-n$ properties were measured using detection impedance, high pass filter and computerized data acquisition system. Statistic Value like maximum charge, repetition rate, average charge, etc. are calculated. It is possible to quantitative analysis of $\Phi-q-n$ properties from this statistic value and pattern analysis.

  • PDF

Analysis of Cleft Lip Nose Deformities Correction in Adults: Detailed Techniques and Comprehensive Review (성인에서의 구순비변형 교정술에 사용된 상세술기의 분석)

  • Choi, Chi-Won;Kang, Kyung-Dong;Kim, Kyoung-Hoon;Bae, Yong-Chan
    • Archives of Plastic Surgery
    • /
    • v.38 no.6
    • /
    • pp.755-760
    • /
    • 2011
  • Purpose: Correction of cleft lip nose deformity (CLND) in adulthood is different from one in childhood. Usually correction of CLND is final surgery for adult patient who has cleft lip, so many things have to be considered for correction. Of course, it is different from common rhinoplasty, either. The adult patients can be corrected by complete rhinoplasty with various techniques. To recognize how rhinoplasty techniques was used for correction of CLND, authors analyzed detailed techniques which were selected in the adult patients for 10 years and reviewed comprehensive operation. Methods: A retrospective review was conducted involving 64 patients with CLND who underwent surgery and aged after 14 years at operation between 2001 and 2010. Detailed techniques were investigated by medical record review and classified according to incision, septoplasty, osteotomies, correction of vault, tip plasty and etc. Results: Except one, all patients were performed open rhinoplasty. 49 patients were performed septoplasty. 33 patients were performed complete rhinoplasty with osteotomies. Hump nose correction was performed for 10 patients. Dorsal augmentation was performed for 8 patients. And all patients were performed tip plasty. Tip plasty using suture technique was performed for 58 patients and graft was performed for 48 patients. Conclusion: Correction of CLND in adult is one of the most challenging and varied operation of plastic surgery. In this study, the majority of patients were performed complicated and delicated procedures. It seems to be because patient's demand level has been elevated and rhinoplasty procedures have been advanced. This study may help to planning of CLND correction.

Survey of Radiation Shielding Design Goals and Workload Based on Radiation Safety Report: Tomotherapy Vault

  • Cho, Kwang Hwan;Jung, Jae Hong;Min, Chul Kee;Bae, Sun Hyun;Moon, Seong Kwon;Kim, Eun Seog;Cho, Sam Ju;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.29 no.1
    • /
    • pp.42-46
    • /
    • 2018
  • The purpose of this study was to perform a survey of the radiation shielding design goals (P) and workload (W) based on the radiation safety reports concerned with structural shielding design for the IMRT treatment technique in Tomotherapy vaults. The values of the P and W factors as well as of a verified concrete thickness of the ceiling, bottom, sidewalls (sidewall-1 and sidewall-2), and door have been obtained from radiation safety reports for a total of 16 out of 20 vaults. The recommended and most widely used report for P values was the NCRP No. 151 report, which stated that the P factor in controlled and uncontrolled areas was 0.1 and 0.02 mSv/week, respectively. The range of the W factor was 600~14,720 Gy/week. The absorbed dose delivered per patient was 2~3 Gy. The maximum number of patients treated per day was 10~70. The quality assurance (QA) dose was 100~1,000 Gy/week. Fifteen values of the IMRT factor (F) were mostly used but a maximum of 20 values was also used. The concrete thickness for primary structures including the ceiling, bottom, sidewalls, and door was sufficient for radiation shielding. The P and W factors affect the calculation of the structural shielding design, and several parameters, such as the absorbed dose, patients, QA dose, days and F factor can be varied according to the type of shielding structure. To ensure the safety of the radiation shielding, it is necessary to use the NCRP No. 151 report for the standard recommendation values.

The Kinetic Analysis K-study of Roche Technique in Horse Vaulting (도마 Roche 기술의 운동역학적 사례분석)

  • Yeo, Hong-Chul;Ryu, Jae-Kyun
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.4
    • /
    • pp.201-207
    • /
    • 2008
  • The purpose of this study was to examine the Roche technique performed by three male subjects in 2003 Taegu World Students Game. Conclusions are as followed. If the angular momentum was increased to counter-clockwise on voulting, the momentum acted like an interrupting factor of body spinning force. The biggest body angle was at VTD phase and the smallest was at BTO phase. At the phase of contacting on vaulting board and taking off from the vaulting board, the biggest personal angle difference between VTD and BTO was found. As the Roche technique was needed not only to fly high but also to increase body spinning rate, the projection angles of Roche technique were showed smaller than those of Cuervo technique. The angular velocity was peak during 2 times forward turn phase. The angular momentum was influenced by angular velocity from BTO and VTD phase.

A Study on the Spatial Characteristics from the "The Holy Trinity" Fresco Painted by Masaccio (마사치오의 "삼위일체" 벽화에서 나타난 공간적인 특성에 관한 연구)

  • Kim, Seok-Man
    • Journal of architectural history
    • /
    • v.22 no.6
    • /
    • pp.7-22
    • /
    • 2013
  • The purpose of this paper is to study on the spatial characteristics from the "The Holy Trinity" fresco painted by Masaccio in the early Renaissance paintings. The results of this study are as follows. 1. The elevation composition of the "The Holy Trinity" fresco is divided into the upper and lower structure through horizontal axis on horizontal line around vanishing point. The upper structure is composed of vertical axis formed through the disposition of the "Trinity" elements and horizontal axis on horizontal line. The lower structure is composed of the sarcophagus and skeleton in such inside and the altar supported through circular columns of left and right. 2. The section composition of the "The Holy Trinity" fresco is composed of the ceiling structure of cylindrical-shaped vault on upper part around basic square floor plan that is interior space and upper structure. The exterior space and lower structure is placed with sarcophagus in inner part that altar and step is projected as same height and width in the outside direction. 3. The basic floor composition of the "The Holy Trinity" fresco is planned by square shape around structural columns that is placed at corners as symmetry through transverse, longitudinal and diagonal axis. The whole floor composition planned through the altar and step that is in exterior space at front, the apse of round form at rear part and the structure of the middle story concept at interior. 4. The visual aspect of the "The Holy Trinity" fresco is composed of the stable balance in relation with distance and height because the interior and exterior space as well as the upper structure and lower structure is formed by regular proportion system. The elevation angle of visual range was planned to view in detail generally or partially the architectural composition system and element, characters through proper visual distance, center and position.

Safety Assessment for LILW Near-Surface Disposal Facility Using the IAEA Reference Model and MASCOT Program (IAEA의 기준모델과 MASCOT 프로그램을 이용한 중저준위방사성폐기물 천층처분시설 안전성평가)

  • Kim, Hyun-Joo;Park, Joo-Wan;Kim, Chang-Lak
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.2
    • /
    • pp.111-120
    • /
    • 2002
  • A reference scenario of vault safety case prepared by the IAEA for the near-surface disposal facility of low-and informed]ate-level radioactive wastes is assessed with the MASCOT program. The appropriate conceptual models for the MASCOT implementation is developed. An assessment of groundwater pathway through a drinking well as a geosphere-biosphere interface is performed first. then biosphere pathway is analysed to estimate the radiological consequences of the disposed radionuclides based on compartment modeling approach. The validity of conceptual modeling for the reference scenario is investigated where possible comparing to the results generated by the other assessment. The result of this study shows that the typical conceptual model for groundwater pathway represented by the compartment model ran be satisfactorily used for safety assessment of the entire disposal system in a cons]stent way. It is also shown that safety assessment of a disposal facility considering complex and various pathways would be possible by the MASCOT program.

A Research on the Classified Structural System in Long-Span Structures (대공간 구조형식 분류체계에 관한 연구)

  • Yang, Jae-Hyuk
    • Journal of Korean Association for Spatial Structures
    • /
    • v.2 no.3 s.5
    • /
    • pp.81-92
    • /
    • 2002
  • The objective of this paper is to help to make decision of the appropriate structural types in long span structured building due to range of span. For the intention, based on 7 forces of structural element, it is analized the relationships among 6 configurations of structural element(d/1), 25 structural types, 4 materials, and span-length known with 186 sample from 1850 to 1996. 1) bending forces: $club(1/100{\sim}1/10),\;plate(1/100{\sim}1/10),\;rahmen(steel,\;10{\sim}24m)\;simple\;beam(PC,\;10{\sim}35m)$ 2) shearing forces: $shell(1/100{\sim}1/1000)\;hyperbolic\;paraboloids(RC,25{\sim}97m)$ 3) shearing+bending forces: plate, folded $plate(RC21{\sim}59m)$ 4) compression axial forces: club, $arch(RC,\;32{\sim}65m)$ 5) compression+tension forces: shell, braced dome $shell(RC,\;40{\sim}201m),\;vault\;shell(RC,\;16{\sim}103m)$ 6) compression+tension axial forces: $rod(1/1000{\sim}1/100)$, cable(below 1/1000)+rod, coble+rod+membrane(below 1/1000), planar $truss(steel,\;31{\sim}134m),\;arch\;truss(31{\sim}135m),\;horizontal\;spaceframe(29{\sim}10\;8m),\;portal\;frame(39{\sim}55m),\;domical\;space\;truss(44{\sim}222m),\;framed\;\;membrane(45{\sim}110m),\;hybrid\;\;membrane\;(42{\sim}256m)$ 7) tension forces: cable, membrane, $suspension(60{\sim}150m),\;cable\;\;beam(40{\sim}130m),\;tensile\;membrane(42{\sim}136m),\;cable\;-slayed(25{\sim}90m),\;suspension\;membrane(24{\sim}97m),\;single\;layer\;pneumatic\;structure(45{\sim}231m),\;double\;layer\;pneumatic\;structures(30{\sim}44m)$

  • PDF