• Title/Summary/Keyword: vascular Compliance

Search Result 58, Processing Time 0.02 seconds

Effect of Complex-exercise on Diabetes Outbreak Prediction Rate, Body Composition and Vascular Compliance in Obese smokers (비만흡연자의 복합운동이 당뇨발생예측률 및 신체조성, 혈관탄성에 미치는 영향)

  • Kim, Seung-Suk
    • Journal of Digital Convergence
    • /
    • v.12 no.10
    • /
    • pp.587-595
    • /
    • 2014
  • This research aimed at analyzing the influence of complex-exercise on diabetes outbreak prediction rate, body composition and vascular compliance in obese smokers and suggesting effective exercise program for obese smokers' healthy life. The research object was composed of the 20 employees, obese smokers in their age of 40s, of T company, which is the subcontractor of H company in D Metropolitan City, who learned the purpose of this research enough and wrote the consent form of voluntary participation, who have no medical history and currently no special disease, as well as no experience in regular exercise. The researcher conducted an inspection on diabetes outbreak prediction rate and body composition, vascular compliance, also, implemented descriptive statistics to calculate the average and standard deviation before the test and after implementing 12 weeks' complex-exercise program, and verification on the difference between before after the test was analyzed by using Paired t-test. With statistical significance level p<.05, the research results are as follows. after participating in 12 weeks' complex-exercise program, diabetes outbreak prediction rate, weight, body fat percentage, skeletal muscle mass, abdominal fat rate and vascular compliance showed statistically meaningful level of change in upper extremities(right hand, left hand), nether extremities(right foot, left foot) p.<05.

Development of the Pulsatile Pump System for a Perfusion Bioreactor (관류형 바이오리액터를 위한 박동 펌프 시스템 개발)

  • Kim, Hak-Jun;Kim, Sun-Hong;Chung, Ho-Yun;Yun, Won-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.4
    • /
    • pp.526-533
    • /
    • 2011
  • This research is about the pulsatile pump system utilized in the perfusion bioreactor for the in vitro human tissue culture. A pulsatile pump system which can be applied to the culture of the vascular tissues including blood vessel is developed by using the idea of human heart's blood pumping into organs as followings: culture chamber, a pressurizing device which generates laminar pulsatile flow by controlling the x-sectional area of the culture media delivering tubing, a compliance chamber which supplies the pressuring device with a constant pressure, and a peristaltic pump which circulates the culture media in a circuit ranging from the culture chamber to the compliance chamber. The developed pulsatile pump system shows that a physiology of the human heart's blood pumping including pulsatile pressure waveform of systolic-diastolic pressure is well represented. Not only time domain but also frequency domain characteristics of pulsatile pump system which are necessary for the vascular tissue culture such as pulsatile pressure waveform's shape, the frequency, and the magnitude can be easily generated and manipulated by using the proposed system.

Study on Vascular Compliance using Photoelectric Plethysmography (광전 용적맥파를 이용한 혈관 탄성도에 관한 연구)

  • Kim, Hong-Yeop;Kim, Kyung-Ho
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2011.01a
    • /
    • pp.111-112
    • /
    • 2011
  • 본 연구에서는 광전 용적맥파(photoelectric plethysmography, PPG)를 기반으로 이를 이용하여 혈관 탄성도를 측정 할 수 있는 시스템에 관하여 연구하였다. 광전 용적맥파는 광을 이용한 비 침습적 맥파 측정 방식으로 손가락 끝 부분에서 측정하고 혈액 내에 헤모글로빈의 빛에 대한 광 흡수도의 차이로 인해 나타나게 된다. 얻어진 신호를 2차 미분 하게 되면 가속도 맥파 (acceleration photoplethymogram, APG)를 얻을 수 있고 이는 혈관 탄성도의 추정에 응용가능하다. 본 연구에서는 혈관 탄성도를 측정하기 위한 방법으로 광전 용적맥파를 적용하여 가속도 맥파 측정기기를 설계하고, 이를 바탕으로 혈관 탄성도 추정에 적용 가능 여부를 연구하였다.

  • PDF

Non-Intrusive Healthcare System for Estimation of Vascular Condition in IP-Enabled Wireless Network (IP 기반 무선네트워크에서의 혈관상태 평가를 위한 무구속 헬스케어 시스템)

  • Jung, Sang-Joong;Kwon, Tae-Ha;Chung, Wan-Young
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.1
    • /
    • pp.76-83
    • /
    • 2013
  • A real-time wireless monitoring and analysis methods using the wearable PPG sensor to estimate cardiovascular condition is studied for ubiquitous healthcare service. A small size and low-power consuming wearable photoplethysmogram (PPG) sensor is designed as a wrist type device and connected with the IP node assigned its own IPv6 address. The measured PPG waveform in the IP node is collected and transferred to a central server PC through the IP-enabled wireless network for storage and analysis purposes. A monitoring and analysis program is designed to process the accelerated plethysmogram (APG) waveform by applying the second order derivatives to analyze systolic waves as well as heart rate variability analysis from the measured PPG waveform. From our results, the features of cardiovascular condition from individual's PPG waveform and estimation of vascular compliance by the comparison of APG-aging index (AI) and ratio of LF/HF are demonstrated.

Flow Dynamics Near End-To-End Anastomoses - Part I. In Vitro Compliance Measurement -

  • Kim, Y.H
    • Journal of Biomedical Engineering Research
    • /
    • v.13 no.2
    • /
    • pp.165-174
    • /
    • 1992
  • Compliance mismatch across an end-to-end anastomosis was measured In the In vitro experimental setup. A 35mm camera was used and Image process was done in Gould/ DeAnza Image processor. The results showed that compliances of Penrose tubing and synthetic PTFE grafts were In good agreement with the previously reported In vivo data. PTFE grafts exhibited a nonlinear behavior with compliance decreasing with Increasing transmural pressure, whereas the compliance of the Penrose tubing remained relatively constant within the range of the pressures in which data were obtained. The lumen cross sections at the anastomosis were affected by the suture and the mismatch In compliance between the Penrose tubing and vascular grafts. The varla~lons In the lumen dtameter at the anastomosis was more pronounced with increasing transmural pressures. From the present study, it was clearly demonstrated that the compliance of prosthetic grafts Is much lower than that of the arteries. In addition to the hemodynamlc consequences, compliance mismatch across the anastomosis has been known to lead to Increased anastomotlc and suture stresses with resultant suture line dehlscence and false aneurysm formation. Thus, there are good hemodynamic reasons to suppose that Introduction of a less compliant arterial graft Into the arterial circulation wlll be damaging and that grafts should be made to match the elastic behavior of their host arteries as closely possible.

  • PDF

Estimation of the Variation of Quantity in PWV in Accordance with the Changes of Position in Human (자세변화에 따른 PWV 변화량의 평가)

  • Jun, Suk-Hwan;Jeong, In-Cheol;Jung, Sang-O;Yoon, Hyung-Ro
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.2
    • /
    • pp.129-134
    • /
    • 2009
  • The ideal method which measures a blood vessel of senility and degree of arteriosclerosis is to measure compliance of arterial and condition of blood circulation at the periphery. In these days vascular stiffness have been assessed by analyzing PTT (pulse transit time) from ECG and PPG. PTT is that between toe and finger each subject estimated through ECG and PPG signals. Two parameters, which are related to PWV, were tested with the time delay between the finger and toe. PWV is a variation of quantity which is associated with vascular stiffness. These researches which use PTT and PWV don't consider the blood vessel characteristic of an individual. In this current research, we have used with the blood vessel characteristic of an individual. That is an assessment of vascular stiffness using the variation of quantity in PWV with the changes of position in the subject. PWV variation increased as functions of the subject's age. The increase of the PWV variation parameters with age is attributed to the direct decrease of the blood vessel compliance with different position. The quantity of variation estimated by experimental results is that old age's (75.78${\pm}$7.75) case is 113.68% and young age's (26.47${\pm}$2.04) case is 85.69%. We proved and presented about estimation of vascular stiffness of possibility by this result.

Influence of the Aqua Exercise on Blood Component and Vascular Compliance of Mental Retardation Men (수중운동 참여가 정신지체장애인의 혈액성분 및 혈관탄성에 미치는 영향)

  • Kim, Won-Hyun;Kim, Seung-Suk;Park, Young-Woo
    • Journal of Digital Convergence
    • /
    • v.11 no.6
    • /
    • pp.235-244
    • /
    • 2013
  • This research was performed to investigate the effects of participation in aqua exercise on blood composition and vascular compliance of mentally retarded persons. The targets of this research consisted of a control group of 12 people and an aqua exercise group of 12 people after selecting 24 mentally retarded males and aqua exercise group carried out an exercise program for 60 minutes per day and five days a week for 9 weeks. Weight, body fat percentage, blood composition and vascular compliance were measured in a preliminary inspection and the same items were measured in a post-inspection. The results of this measurement were as follows. Firstly, aqua exercise group showed a significant decrease in weight and body fat percentage (p<.05). Secondly, for blood composition, aqua exercise group showed a notable decrease in Total-Cholesterol, Triglyceride, and LDL-Cholesterol (p<.05) and a significant increase in HDL-Cholesterol (p<.05). Thirdly, aqua exercise group showed a notable increase in blood composition for both upper limbs and lower limbs (p<.05). Taken these results together, it was considered that a participation of mentally retarded persons in aqua exercise would prevent adult diseases and would have an affirmative influence on improvement of the quality of life.

Measurement of Leg Arterial Compliance of Normal and Diabetics (정상인과 당뇨병 환자의 다리 동맥의 Compliance 측정)

  • 김덕원;김상수
    • Journal of Biomedical Engineering Research
    • /
    • v.13 no.3
    • /
    • pp.189-194
    • /
    • 1992
  • As people's income and intake of animal fat rapidly increase, so does choresterol concentration in blood. Thus diseases such as non-insulin-dependent diabetes mellitus(NIDDM)myocardial infraction, high blood pressure, cerebral stroke resulting from atherosclerosis rapidly increase recently. It is very difficult to diagnose atherosclerosis early since its progress is so slow and there is no sypmtoms in the beginning of the disease. In this study a mechanical characteristic, compliance, of the lower leg arteries was measured noninvasively. Changes of blood volume and pressure were measured using impedance plethysmgraphy and mercury sphygmomanometer, respectively. The compliance was calculated by dividing the change of blood volume by the change of pulse pressure ( systolic-diastolic pressure ) . Subjects were 24 asymptomatic persons ranging (rom 30 Ic 58yeras and 14 diabetics from 41 to 59years. The compliances, mean, and systolic pressures were statistically analyzed using a t-test be- tween the healthy and diabetic groups. The average compliance of the healthy and diabetic group was measured 2.79 and 1.82U1/mmHg/cm, respectively and these were significantly different(p<0.01). It was also found that the compliance is a better parameter in differentiating the vascular disease than mean or systolic blood pressure.

  • PDF

Analysis of Spironolactone Use in Chronic Heart Failure

  • Park, Kyu-Won;Lee, Suk-Hyang
    • Proceedings of the PSK Conference
    • /
    • 2003.10b
    • /
    • pp.250.1-250.1
    • /
    • 2003
  • Background Aldosterone has an important role in the pathophysiology of heart failure. Aldosterone promotes the retention of sodium, the loss of magnesium and potassium, sympathetic activation, parasympathetic inhibition, myocardial and vascular fibrosis, baroreceptor dysfunction, and vascular damage and impairs arterial compliance. Objectives We investigated the effects of additional spironolactone to angiotensin-converting enzyme inhibitor (ACEI) / angiotensin-II receptor blocker (ARB) in patients with heart failure. (omitted)

  • PDF

Hemodynamic Effects on Artery-Graft Anastomotic Intimal Hyperplasia (혈류의 유동이 혈관-인조혈관 접속부 혈관 내막 세포증식에 미치는 영향)

  • 이계한
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.2
    • /
    • pp.143-150
    • /
    • 1994
  • Wall shear rate or stress is believed to be a major hemodynamic variable influencing atherosclerosis and artery-graft anastomic intimal hyperplasia. The purpose of this study is to verify the effects of radial wall motion, artery-graft compliance and diameter mismatch, and impedance phase angle on the wall shear rate distribution near an end-to-end artery-graft anastomosis model. The results show that radial wall motion of the elastic artery model lowers the mean wall shear rates under pulsatile flow condition by 15 to 20 % comparing to those under steady flow condition at the same mean flow rate. Impedance phase angle seems to have small effects on the mean and amplitude of the wall shear rate distribution. In order to study the effects of compliance and diameter mismatch on the wall shear rates, two models are studied-Model I has 6% and Model I has 6% and Model II has 11% smaller graft diameter. Divergent geometry caused by diameter mismatch near the distal sites reduces the mean wall shear rates significantly, and this low shear region is believed to be prone to intimal hyperplasia.

  • PDF