• Title/Summary/Keyword: varying location

Search Result 276, Processing Time 0.024 seconds

Modified RHKF Filter for Improved DR/GPS Navigation against Uncertain Model Dynamics

  • Cho, Seong-Yun;Lee, Hyung-Keun
    • ETRI Journal
    • /
    • v.34 no.3
    • /
    • pp.379-387
    • /
    • 2012
  • In this paper, an error compensation technique for a dead reckoning (DR) system using a magnetic compass module is proposed. The magnetic compass-based azimuth may include a bias that varies with location due to the surrounding magnetic sources. In this paper, the DR system is integrated with a Global Positioning System (GPS) receiver using a finite impulse response (FIR) filter to reduce errors. This filter can estimate the varying bias more effectively than the conventional Kalman filter, which has an infinite impulse response structure. Moreover, the conventional receding horizon Kalman FIR (RHKF) filter is modified for application in nonlinear systems and to compensate the drawbacks of the RHKF filter. The modified RHKF filter is a novel RHKF filter scheme for nonlinear dynamics. The inverse covariance form of the linearized Kalman filter is combined with a receding horizon FIR strategy. This filter is then combined with an extended Kalman filter to enhance the convergence characteristics of the FIR filter. Also, the receding interval is extended to reduce the computational burden. The performance of the proposed DR/GPS integrated system using the modified RHKF filter is evaluated through simulation.

Effects of the irrigation Rate on Wetted Patterns in Sandy Loam Soil Under Trickle irrigation Condition (점적관개에서 관개율이 Sandy Loam토양의 습윤양상에 미치는 영향)

  • 김철수;이근후
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.31 no.2
    • /
    • pp.104-115
    • /
    • 1989
  • In an effort to clarify the wetted patterns of sandy loam soil under trickle irrigation conditions, the distance of wetted zone, infiltration capacity and soil wetted patterns, etc. were measured by gypsum block as soil moisture sensor located every 5 cm vertically and horizontaly in the soil bin under the such conditions as a). irrigation rates set to 2, 4, 6, 8 liters per hour b). total amount of water applied fixed to 14.62 liters per soil bin c) the hearing force of soil measured by plate penetrometer ranging from 1.04 to 1.22kg/cm$_2$ The results can be summarized as follows ; 1. The wetted distance in horizontal direction(H), the wetted distance in vertical direction(D), the horizontal infiltration capacity (iH) and the vertical infiltration capacity(in)could by explained as a function of time t. 2. The horizontal wetted distance (H) is explained by an exponetial function H= a$.$ t where b was found ranging from 021 to 026 under surface trickle irrigation, which was considered a lotlower than the classical value of 0.5 and these measurements were indifferent to the increasing irrigation rates. 3. As for the surface trickle irrigation where horizontal infiltration capacity(iH) is explained as iH = A $.$ t h, the coefficient A increases with respect to irrigation rates within the limits of 0.89~1.34. 4. In terms of surface trickle irrigation of the ratio of Dm Which is maximum vertical wetted distance to Hm, which is maximum horizontal wetted distance, found to be within range of 1.0 to 1.21. It was also noted that the value of Dm decreses when irrigation rates increases while the value of Hm changes the opposite direction. 5. The optimum location of sensors from emitter for surface trickle irrigation should he inside of hemisphere whose lateral radius is 28~30cm long and vertical radius is 10~12cm long. The distance between emitters should be within 60cm long. 6. In the study of vertical wetted distance( D) where D= a $.$ tb, the exponential coefficient b ranged from 0.61 to 0.75 in surface trickle irrigation, and from 0A9 to 0.68 for subsurface trickle irrigation. These measurements showed an increasing tendency to with respect to irrigation rates. 7. In case of vertical infiltration capacity( in), where iD= A $.$ t 1-h, the coefficient A for surface trickle irrigation found to be within range of 0.16 to 0.19 and did not show any relationships with varying degree of irrigation rates. However, the coefficient was varying from 0.09 to 0.22 and showed a tendency to increase vis-a-vis irrigation rates for subsurface trickle irrigation, in contrast. 8. In the observation of subsurface trickle irrigation, it was found that Dm/Hm ratio was within 1.52 to 1.91 and showed a decreasing tendency with respect to increasing rates of irrigation. 9. The location of sensors for subsurface trickle irrigation follows same pattern as above, with vertical distance from emitter being 10~17cm long and horizontal 22~25cm long. The location of emitter should be 50 cm. 10.The relationship between VS which is the volume of wetted soil and Q which is the total amount of water when soil is reached field capacity could be explained as VS= 2.914Q0.91and the irrigation rates showed no impacts on the above relationship.

  • PDF

Measurements and Analysis of Fingerprinting Structures for WLAN Localization Systems

  • Al KhanbashI, Nuha;Al Sindi, Nayef;Ali, Nazar;Al-Araji, Saleh
    • ETRI Journal
    • /
    • v.38 no.4
    • /
    • pp.634-644
    • /
    • 2016
  • Channel-based radio-frequency fingerprinting such as a channel impulse response (CIR), channel transfer function (CTF), and frequency coherence function (FCF) have been recently proposed to improve the accuracy at the physical layer; however, their empirical performance, advantages, and limitations have not been well reported. This paper provides a comprehensive empirical performance evaluation of RF location fingerprinting, focusing on a comparison of received-signal strength, CIR-, CTF-, and FCF-based fingerprinting using the weighted k-nearest neighbor pattern recognition technique. Frequency domain channel measurements in the IEEE 802.11 band taken on a university campus were used to evaluate the accuracy of the fingerprinting types and their robustness to human-induced motion perturbations of the channel. The localization performance was analyzed, and the results are described using the spatial and temporal radio propagation characteristics. In particular, we introduce the coherence region to explain the spatial properties and investigate the impact of the Doppler spread in time-varying channels on the time coherence of RF fingerprint structures.

Optimal Location and Sizing of Shunt Capacitors in Distribution Systems by Considering Different Load Scenarios

  • Dideban, Mohammadhosein;Ghadimi, Noradin;Ahmadi, Mohammad Bagher;Karimi, Mohammmad
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.5
    • /
    • pp.1012-1020
    • /
    • 2013
  • In this work, Self-adaptive Differential Evolutionary (SaDE) algorithm is proposed to solve Optimal Location and Size of Capacitor (OLSC) problem in radial distribution networks. To obtain the SaDE algorithm, two improvements have been applied on control parameters of mutation and crossover operators. To expand the study, three load conditions have been considered, i.e., constant, varying and effective loads. Objective function is introduced for the load conditions. The annual cost is fitness of problem, in addition to this cost, CPU time, voltage profile, active power loss and total installed capacitor banks and their related costs have been used for comparisons. To confirm the ability of each improvements of SaDE, the improvements are studied both in separate and simultaneous conditions. To verify the effectiveness of the proposed algorithm, it is tested on IEEE 10-bus and 34-bus radial distribution networks and compared with other approaches.

Prediction of Curvature Effects on the Electromagnetic Flowmeter Characteristics with Numerical Simulation (Laminar flow) (곡관의 곡률에 따른 전자기유량계 설치효과의 수치모사에 의한 특성 예측(충류))

  • Lim, Ki Won;Choi, Sang Kyu;Chung, Myung Kyoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.11
    • /
    • pp.1453-1463
    • /
    • 1999
  • An electromagnetic flowmeter, based on a magnetic induction principle; provides an obstructionless flowmeter that essentially averages the velocity distribution over the pipe cross-sectional area. To predict the installation effects, the flowmeter installed near $90^{\circ}$ elbow is simulated by using a commercial code FLUENT(ver. 4.48) for the laminar flow field and a code developed through this study for magnetic field. The installation effects of the flowmeter are estimated by varying a number of the dependent parameters such as the radius of the elbow(Rc=1D, 1.5D, 2D, 3D), the location, Reynolds number and the direction of electrodes plane(${\varphi}$). It was found that all these factors affect the performance of the electromagnetic flowmeter significantly. The longer installation distance from the elbow is not always optimal to minimize the error, and also there exists an optimal location to install the EMF for a minimum error. Especially the flow signal with the electrodes plane direction of ${\varphi}=45^{\circ}$ is shown to yield smallest measurement error regardless of the Reynolds number and the curvature of elbow.

Bubble size characteristics in the wake of ventilated hydrofoils with two aeration configurations

  • Karn, Ashish;Ellis, Christopher R;Milliren, Christopher;Hong, Jiarong;Scott, David;Arndt, Roger EA;Gulliver, John S
    • International Journal of Fluid Machinery and Systems
    • /
    • v.8 no.2
    • /
    • pp.73-84
    • /
    • 2015
  • Aerating hydroturbines have recently been proposed as an effective way to mitigate the problem of low dissolved oxygen in the discharge of hydroelectric power plants. The design of such a hydroturbine requires a precise understanding of the dependence of the generated bubble size distribution upon the operating conditions (viz. liquid velocity, air ventilation rate, hydrofoil configuration, etc.) and the consequent rise in dissolved oxygen in the downstream water. The purpose of the current research is to investigate the effect of location of air injection on the resulting bubble size distribution, thus leading to a quantitative analysis of aeration statistics and capabilities for two turbine blade hydrofoil designs. The two blade designs differed in their location of air injection. Extensive sets of experiments were conducted by varying the liquid velocity, aeration rate and the hydrofoil angle of attack, to characterize the resulting bubble size distribution. Using a shadow imaging technique to capture the bubble images in the wake and an in-house developed image analysis algorithm, it was found that the hydrofoil with leading edge ventilation produced smaller size bubbles as compared to the hydrofoil being ventilated at the trailing edge.

Wave force Acting on the Artificial Rock installed on a Submerged Breakwater in a Regular Wave field (잠제상에 설치된 표식암(의암)에 작용하는 규칙파파력의 실험적 연구)

  • 배기성;허동수
    • Journal of Ocean Engineering and Technology
    • /
    • v.16 no.6
    • /
    • pp.7-17
    • /
    • 2002
  • Recently, artificial rocks, instead of buoys, have been placed on the submerged breakwater to indicate its location. The accurate estimation of wave forces on these rocks is deemed necessary for their stability design. Characteristics of the wave force, however, are expected . to be very complicated because of the occurrence of breaking or post-breaking waves. In this regard, wave forces exerted on an artificial rock have been investigated in this paper. The maximum wave force has been found to strongly dependent on the location and shape of the artificial rock that is placed on the submerged breakwater. The plunging breaker occurs near the loading cram edge of a submerged breakwater, which cause impulsive breaking wave force on the rock. Using the Morison equation, with the velocity and acceleration at the front face of the artificial rock and varying water surface level, it is possible to estimate wave forces, even impulsive breaking wave forces, that are acting on the rock installed on a submerged breakwater. The vertical wave force is also found to depend, significantly, on the buoyant force.

Numerical Analysis of Flow Phenomena in Cylindrical Shell with Baffle according to the Position of Inlet and Outlet (출.입구 위치에 따른 배플을 갖는 원통내 유동특성에 대한 수치해석)

  • Shin, Y.H.;Sayeed, S.M.;Jean, Y.C.;Chung, H.S.;Jeong, H.M.
    • Journal of Power System Engineering
    • /
    • v.15 no.6
    • /
    • pp.22-26
    • /
    • 2011
  • A numerical simulation on the flow field was carried out on the cylindrical shell with baffles. The steady incompressible 3-D Navier-Stokes solution is obtained with the actual operational condition and geometry of the heat exchanger. The effect of the location of inlet and outlet on the cylindrical shell with baffle is investigated by varying flow rate. The angle between the location of In/Outlet and baffle cutting part is $0^{\circ}$, $30^{\circ}$, $60^{\circ}$, $90^{\circ}$, $120^{\circ}$, $150^{\circ}$ and $180^{\circ}$. The present results show that the pressure drop is dependent on Reynolds number in the inlet area and position of inlet and outlet; i.e., the pressure drop increases with increasing Reynolds number and the pressure drop decreases with increasing angle between baffle cutting part and position of inlet and outlet.

Verification of Two Least-Squares Methods for Estimating Center of Rotation Using Optical Marker Trajectory

  • Lee, Jung Keun
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.371-378
    • /
    • 2017
  • An accurate and robust estimation of center of rotation (CoR) using optical marker trajectory is crucial in human biomechanics. In this regard, the performances of the two prevailing least-squares methods, the Gamage and Lasenby (GL) method, and the Chang and Pollard (CP) method, are verified in this paper. While both methods are sphere-fitting approaches in closed form and require no tuning parameters, they have not been thoroughly verified by comparison of their estimation accuracies. Furthermore, while for both methods, results for stationary CoR locations are presented, cases for perturbed CoR locations have not been investigated for any of them. In this paper, the estimation performances of the GL method and CP method are investigated by varying the range of motion (RoM) and noise amount, for both stationary and perturbed CoR locations. The difference in the estimation performance according to the variation in the amount of noise and RoM was clearly shown for both methods. However, the CP method outperformed the GL method, as seen in results from both the simulated and the experimental data. Particularly, when the RoM is small, the GL method failed to estimate the appropriate CoR while the CP method reasonably maintained the accuracy. In addition, the CP method showed a considerably better predictability in CoR estimation for the perturbed CoR location data than the GL method. Accordingly, it may be concluded that the CP method is more suitable than the GL method for CoR estimation when RoM is limited and CoR location is perturbed.

Heat and Flow Analysis Inside a Parallel-Flow Heat Exchanger (평행류 열교환기 내부의 열유동 해석)

  • Oh, Seok-Jin;Chung, Kil-Yoan;Lee, Kwan-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.6
    • /
    • pp.781-788
    • /
    • 2003
  • In the present study, the heat and flow characteristics of a parallel-flow heat exchanger are numerically analyzed by using three-dimensional turbulent modeling. Heat transfer rate and pressure drop are evaluated using the concept of the efficiency index by varying the locations, the shapes and angles of inlet/outlet, and the protrusion height of flat tube. It is found that negative angle of the inlet improves the heat transfer rate and pressure drop. Results show that the locations of the inlet and outlet should be toward the right side and the left side to the reference model, respectively, in order to enhance the heat transfer rate and pressure drop. Increasing the height of the lower header causes pressure drop to decrease and yields the good flow characteristics. The lower protrusion height of flat tube shows the improvement of the heat transfer rate and pressure drop. The heat transfer rate is greatly affected by the parameters of outlet side such as the location and angle of the outlet. However, the pressure drop is influenced by the parameters of inlet side such as the location and angle of inlet and the height of the header.