• 제목/요약/키워드: variable speed wind turbine

검색결과 139건 처리시간 0.027초

Maximum Power Point Tracking in PMSG Using Fuzzy Logic Algorithm

  • ;이홍희
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2009년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.135-138
    • /
    • 2009
  • In this paper, a novel maximum power point tracking (MPPT) for a PMSG-based variable speed wind power system is proposed using the fuzzy logic algorithm. The control algorithm is developed based on the normal hill climb searching (HCS) method, commonly used in wind energy conversion systems (WECS). The inputs of fuzzy-based controller are the derivations of DC output power and the step size of DC/DC converter duty cycles. The main advantages of the proposed MPPT method are no need to measure the wind velocity and the generator rotational speed. As such, the control algorithm is independent of turbine characteristics, achieving the fast dynamic responses with non-linear fuzzy systems. The effectiveness of the proposed MPPT strategy has been verified through the simulated results.

  • PDF

풍력발전용 DFIG의 역률 해석 (A Analysis of Power Factor in DFIG for Wind Power Generating System)

  • 이우석;서영택;오철수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 A
    • /
    • pp.322-325
    • /
    • 1997
  • Concerns for wind energy as alternative energy have been highly increased. In this paper, the mechanism between mechanical wind turbine and power generating system is presented to specify the relationship of the energy transfer. Grid-connected DFIG could achieve unity leading power factor, in addition to variable speed operation at the wide sub-synchronous and super-synchronous shaft speed range and also its independent control of torque and reactive power is possible.

  • PDF

Design and Experimental Validation of a Digital Predictive Controller for Variable-Speed Wind Turbine Systems

  • Babes, Badreddine;Rahmani, Lazhar;Chaoui, Abdelmadjid;Hamouda, Noureddine
    • Journal of Power Electronics
    • /
    • 제17권1호
    • /
    • pp.232-241
    • /
    • 2017
  • Advanced control algorithms must be used to make wind power generation truly cost effective and reliable. In this study, we develop a new and simple control scheme that employs model predictive control (MPC), which is used in permanent magnet synchronous generators and grid-connected inverters. The proposed control law is based on two points, namely, MPC-based torque-current control loop is used for the generator-side converter to reach the maximum power point of the wind turbine, and MPC-based direct power control loop is used for the grid-side converter to satisfy the grid code and help improve system stability. Moreover, a simple prediction scheme is developed for the direct-drive wind energy conversion system (WECS) to reduce the computation burden for real-time applications. A small-scale WECS laboratory prototype is built and evaluated to verify the validity of the developed control methods. Acceptable results are obtained from the real-time implementation of the proposed MPC methods for WECS.

A Self-Excited Induction Generator with Simple Voltage Regulation Suitable for Wind Energy

  • Ahmed Tarek;Nishida Katsumi;Nakaoka Mutsuo
    • Journal of Power Electronics
    • /
    • 제4권4호
    • /
    • pp.205-216
    • /
    • 2004
  • In this paper, a three-phase induction machine-based wind power generation scheme is proposed. This scheme uses a low-cost diode bridge rectifier circuit connected to an induction machine via an ac load voltage regulator (AC-LVR) to regulate dc power transfer. The AC-LVR is used to regulate the DC load voltage of the diode bridge rectifier circuit which is connected to the three-phase self-excited induction generator (SEIG). The excitation of the three-phase SEIG is supplied by the static VAR compensator (SVC). This simple method for obtaining a full variable-speed wind turbine system by applying a back-to-back power converter to a wound rotor induction generator is useful for wind power generation at widely varying speeds. The dynamic performance responses and the experimental results of connecting a 5kW 220V three-phase SEIG directly to a diode bridge rectifier are presented for various loads. Moreover, the steady-state simulated and experimental results of the PI closed-loop feedback voltage regulation scheme prove the practical effectiveness of these simple methods for use with a wind turbine system.

공중 풍력발전 기술개발 현황 및 시장전망 (Technical Development Status and Market Prospects for High Altitude Wind Power Generation System)

  • 강승원;길두송;박동수;정원섭;김의환
    • 신재생에너지
    • /
    • 제7권2호
    • /
    • pp.36-42
    • /
    • 2011
  • The wind speed at the altitude around 300 m is much higher and less variable than at the altitude around 80 m which is the same height of the MW class tower turbine's hub height. The wind power density is increased 0.37 W/$m^2$ per meter at the altitude around 6 to 7 km and 0.25 W/$m^2$ per meter at the altitude around 80 to 500 m. There are two types of power generation systems using lifting bodies. The one is that The generator is installed in the ground station and stretched into the lifting body through the tether. The other is that the generator is installed in the lifting body and stretched into the ground station through the tether. Many kinds of lifting bodies are also researched in the world, called kites, wings, single or twin aerostat, and so on. This article introduced the technical development status and the market prospects of the high altitude wind power generation system all over the world in detail.

제주 북동부 지역의 지형과 대기변수에 따른 AEP계산의 정확성에 대한 연구 (An Accuracy Estimation of AEP Based on Geographic Characteristics and Atmospheric Variations in Northern East Region of Jeju Island)

  • 고정우;이병걸
    • 한국측량학회지
    • /
    • 제30권3호
    • /
    • pp.295-303
    • /
    • 2012
  • 풍력발전 단지의 수익성 평가를 위해 연간 에너지 생산량(AEP ; Annual Energy Production)의 계산이 중요하다. AEP를 계산하기 위해서는 바람의 확률밀도함수(PDF ; Probability Density Function)와 풍력발전기의 발전곡선(PC; Power Curve)이 필요하며, AEP 예측의 정확성을 향상시키기 위해서는 허브 높이에서의 PDF예측과 그 높이의 공기밀도에 따른 풍력발전기 PC의 결정이 중요하다. 본 연구에서는 제주도 한동, 평대의 실관측 풍황탑(met mast) 자료를 이용하였으며 풍속의 PDF를 Weibull 분포 함수로 가정 하였고 Weibull 함수의 파라미터의 값이 높이에 따라 변화하는 양상을 확인하였다. Weibul 함수의 계산은 모멘트법과 LN-least법을 사용하였으며, 모멘트법과 LN-least법에 의한 형상계수의 경우 높이의 증가에 따라 변화를 보이지 않았고 평균값에서 ${\pm}0.1$의 변화 패턴을 보였다. 척도계수의 경우 높이가 증가함에 따라 선형적으로 증가하였으며 지형별 분류에 따른 높이별 척도계수의 기울기는 확연한 차이를 보이고 있었다. 60m 높이에서 관측된 바람의 상대도수와 관측 값의 높이 보정에 의한 공기밀도와 일반식에 의한 공기밀도를 각각 계산하여 그 결과에 대응하는PC를 선택하여 AEP차이를 계산하였다.

이중여자 유도형 풍력 발전기의 PSCAD 시뮬레이션 모델 개발 (Development of PSCAD Simulation Model for Doubly-fed Induction-type Wind Power Generation System)

  • 정병창;김희중;정용호;전영수;곽노홍;송승호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.261-264
    • /
    • 2006
  • In this paper, doubly-fed induction-type wind power generation system simulation model for grid connection is developed. The simulation model is based on PSCAD/EMTDC and consists of rotor-blade, blade controller, generator power converter and generator controller Blade controller controls the blade pitch angle for starting, peak power limiting and emergency condition. Generator controller controls the generator output power to maximize the system efficiency. Simulation results are shown for the variable wind speed conditions. The simulation model can be utilized for study of actual interaction between wind turbine and grid for reliable operation and protection of power system.

  • PDF

AC and DC Applications of Induction Generator Excited by Static VAR Compensator

  • Ahmed, Tarek;Nishida, Katsumi;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • 제4권3호
    • /
    • pp.169-179
    • /
    • 2004
  • This paper presents the steady-state analysis of the three-phase self-excited induction generator (SEIG). The three-phase SEIG with a squirrel cage rotor is driven by a variable-speed prime mover (VSPM) or a constant-speed prime mover (CSPM) such as a wind turbine or a micro gas turbine. Furthermore, a PI closed-loop feedback voltage regulation scheme of the three-phase SEIG driven by a VSPM on the basis of the static VAR compensator (SVC) is designed and evaluated for the stand-alone AC and DC power applications. The simulation and experimental results prove the practical effectiveness of the additional SVC with the PI controller-based feedback loop in terms of its fast responses and high performances

가변속 풍력발전 시스템의 계통연계 인버터 출력전류 리플 개선에 관한 연구 (Improvement of Output Current Ripple In Grid Connected PWM Inverter for Variable Speed Wind Turbine System)

  • 강신일;송승호;김동용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.369-372
    • /
    • 2003
  • 풍력발전 시스템은 계통에 전력을 공급하는 분산형 전원형태가 대부분이어서 어느 분산형 전원보다 계통 연계시 선로에 미치는 영향이 큰 발전설비이다. 특히 가변속 시스템인 경우 풍속이 낮은 영역에서도 운전이 가능하다는 장점이 있지만 저풍속 영역에서 풍속 변동시 터빈 회전자 출력의 리플이 직류단 전압을 변동하게 만든다. 기존의 직류단 전압 일정제어기를 사용하는 경우 인버터 출력전류는 정현파가 아닌 고조파 리플을 포함하는 문제가 발생한다. 본 논문에서는 이러한 문제점을 해결하고자 직류단 전압에 저역통과 필터를 사용하여 인버터 출력전류의 리플 개선을 하였다.

  • PDF

PSCAD/EMTDC를 사용한 이중여자 유도형 풍력발전 시스템의 시뮬레이션 모델 개발 (Development of PSCAD/EMTDC Simulation Model for Doubly-Fed Induction-type Wind Power Generation System)

  • 정병창;송승호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.253-256
    • /
    • 2005
  • In this paper, doubly-fed induction-type wind power generation system simulation model for grid connection is developed. The simulation model is based on PSCAD/EMTDC and consists of rotor-blade, generator, power converter and controller. Simulation results are shown for the variable wind speed conditions. The simulation model can be utilized for study of actual interaction between wind turbine and grid for reliable operation and protection of power system.

  • PDF