• Title/Summary/Keyword: variable frequency control

Search Result 531, Processing Time 0.025 seconds

The Drive and Control Circuit Design of Cold Cathode Fluorescent Lamp for LCD Back Lighting (LCD 조광용 냉음극 형광램프의 구동 및 제어)

  • Kim Cherl-Jin;Hong Dae-Shik;Hwang Yo-Han;Yoon Shin-Yong
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1211-1213
    • /
    • 2004
  • CCFL(cold cathode fluorescent lamp) are used to backlight of LCD(liquid crystal display). CCFL dimming methods are used to pulse frequency modulation(PFM) or pulse width modulation(PWM). In this paper, design of CCFL driving and control circuit by half-bridge type series and parallel resonant inverter that variable frequency modulation method to control the output voltage current. Inverter switching frequency is higher than resonant frequency for stable operating, and it is possible dimming control. On the basis of equivalent circuit, the validity of this study is confirmed by the comparison of simulation and experimental result.

  • PDF

Harmonic Suppression of the Input Current in Microwave Oven Using LLC Resonant Inverter (전자레인지용 LLC 공진형 인버터의 입력전류 고조파 억제)

  • Kang, Kyelyong;Kim, Heung-Geun;Cha, Honnyong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.3
    • /
    • pp.225-230
    • /
    • 2018
  • This paper proposes a parametric design of an LLC resonant inverter used for a microwave oven. To improve the harmonic performance of the microwave oven, a current controller with a variable PI gain is proposed. Due to the recent strengthening of harmonics regulations, inverter control technology for microwave ovens is now required to satisfy harmonic performance. In an LLC resonant inverter, the voltage gain varies remarkably depending on the magnetron voltage, output power, and input voltage. To satisfy harmonic performance, a controller that can maintain operation in the zero-voltage switching (ZVS) region and control changes in voltage gain is required. The modified design of the LLC resonant inverter ensures ZVS operation even when the magnetron is heated. Application of the variable current controller improves harmonic control according to the instantaneous gain curve change. The validity of the proposed power control with a variable current controller is verified by experiments with a 1200 W microwave oven.

A Position Control of BLDC Motor in a Rail Guided System for the Un-maned Facility Security (무인 설비 감시용 레일 가이드 구동장치에서 BLDC 전동기의 위치 제어)

  • Bae, Jong-Nam;Lee, Dong-Hee
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.3
    • /
    • pp.223-230
    • /
    • 2017
  • A low-cost BLDC motor with hall sensor is used to drive the position control of a facility security monitoring system in this paper. Low measurable frequency of the hall sensor signal in low-speed regions results in difficulty in obtaining accurate speed detection and position control. To improve system control performance, we propose a variable gain of position controller and stop mode control scheme according to the motor speed and error position with pre-set deceleration time. The proposed stop mode control scheme is activated around the stop position to forcibly move the BLDC motor to the stop position in low speed. In the proposed stop mode, the motor current is controlled by the actual speed with the reference rotating angle. The control performance of the proposed position control is verified through experiments at the actual rail guided facility security monitoring system.

Control Design of the Brushless Doubly-Fed Machines for Stand-Alone VSCF Ship Shaft Generator Systems

  • Liu, Yi;Ai, Wu;Chen, Bing;Chen, Ke
    • Journal of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.259-267
    • /
    • 2016
  • This paper presents a stand-alone variable speed constant frequency (VSCF) ship shaft generator system based on a brushless doubly-fed machine (BDFM). In this system, the output voltage amplitude and frequency of the BDFM are kept constant under a variable rotor speed and load by utilizing a well-designed current vector controller to regulate the control winding (CW) current. The control scheme is proposed, and the hardware design for the control system is developed. The proposed generator system is tested on a 325 TEU container vessel, and the test results show the good dynamic performance of the CW current vector controller and the whole control system. A harmonic analysis of the output voltage and a fuel consumption analysis of the generator system are also implemented. Finally, the total efficiency of the generator system is presented under different rotor speeds and load conditions.

A Study on the Particular Harmonics Elimination in VSI-FED Induction Motor (전압형 인버터로 구동되는 유도전동기의 특정고조파제거에 관한 연구)

  • 전희종;김국진
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.2 no.2
    • /
    • pp.64-70
    • /
    • 1988
  • In many applications of inverter system, it is desirable to obtain an AC output voltage with variable frequency and amplitude. For the variable-speed AC motor drive, the system is one major area of application for the variable-frequency inverter. V ariable~voltage variable-frequency sinusoidal output in three-phase inverter is possible by employing the techniques developed. In this paper, the technique of particular harmonics elimination(PHE) in three-phase PWM inverter-output waveforms is introduced. The required switching patterns are determind on personal computer. Results are stored in look-up table in EPROM and used to control the switching of the inverter devices. The experimental results indicate that the loss in an induction motor is minimized to a degree by using this algorithm. The proposed PWM pattern is effective not only to the induction motor but also to the other electromagnetic machine such as Voltage Regulator, UPS.

  • PDF

Extending Switching Frequency for Torque Ripple Reduction Utilizing a Constant Frequency Torque Controller in DTC of Induction Motors

  • Jidin, Auzani;Idris, Nik Rumzi Nik;Yatim, Abdul Halim Mohd;Sutikno, Tole;Elbuluk, Malik E.
    • Journal of Power Electronics
    • /
    • v.11 no.2
    • /
    • pp.148-155
    • /
    • 2011
  • Direct torque control(DTC) of induction machines is known to offer fast instantaneous torque and flux control with a simple control structure. However, this scheme has two major disadvantageous, namely, a variable inverter switching frequency and a high torque ripple. These problems occur due to the use of hysteresis comparators in conventional DTC schemes, particularly in controlling the output torque. This paper reviews the utilization of constant frequency torque controllers (CFTC) in DTC to solve these problems while retaining the simple control structure of DTC. Some extensions of the work in utilizing a CFTC will be carried out in this paper which can further reduce the torque ripple. This is particularly useful for a system which has a limited/low sampling frequency. The feasibility of a CFTC with an extended carrier frequency in minimizing the torque ripple is verified through experimental results.

A Study on the Control of Solenoid Valve for Heating by using Power Line Communication (PLC) (전력선 통신을 이용한 난방용 솔레노이드밸브 제어에 관한 연구)

  • 신관우;김용태;이윤섭
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.8
    • /
    • pp.647-650
    • /
    • 2003
  • PLC (Power Line Communication) is the communication method using the existing power line installed in houses and offices to convert and transmit high frequency communication signal from tens of KHz to tens of MHz, and receive the filtered signal using high frequency filter The advantage of PLC is that PLC uses the existing power line installed in houses and offices so it does not require separate power line. Easy and convenient access using electric outlets is another advantage of PLC. However, PLC has some disadvantages such as limited transmission power, high load interference and noise, variable signal attenuation, characteristic of impedance, and selective possibility of frequency property. We designed the boiler temperature control system unit by using the PLC modem. We can avoid unnecessary heating of separate temperature control unit, and save the cost accordingly control stability of the proposed system is proven through the experiment.

A New Approach for Constant DC Link Voltage in a Direct Drive Variable Speed Wind Energy Conversion System

  • Jeevajothi, R.;Devaraj, D.
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.529-538
    • /
    • 2015
  • Due to the high efficiency and compact mechanical structure, direct drive variable speed generators are used for power conversion in wind turbines. The wind energy conversion system (WECS) considered in this paper consists of a permanent magnet synchronous generator (PMSG), uncontrolled rectifier, dc-dc boost converter controlled with maximum power point tracking (MPPT) and adaptive hysteresis controlled voltage source inverter (VSI). For high utilization of the converter's power capability and stabilizing voltage and power flow, constant DC-link voltage is essential. Step and search MPPT algorithm which senses the rectified voltage ($V_{DC}$) alone and controls the same is used to effectively maximize the output power. The adaptive hysteresis band current control is characterized by fast dynamic response and constant switching frequency. With MPPT and adaptive hysteresis band current control in VSI, the DC link voltage is maintained constant under variable wind speeds and transient grid currents respectively.

Implementation and Control of AC-DC-AC Power Converter in a Grid-Connected Variable Speed Wind Turbine System with Synchronous Generator (동기기를 사용한 계통연계형 가변속 풍력발전 시스템의 AC-DC-AC 컨버터 구현 및 제어)

  • Song Seung-Ho;Kim Sung-Ju;Hahm Nyon-Kun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.12
    • /
    • pp.609-615
    • /
    • 2005
  • A 30kW electrical power conversion system is developed for a variable speed wind turbine. In the wind energy conversion system(WECS) a synchronous generator with field current excitation converts the mechanical energy into electrical energy. As the voltage and the frequency of the generator output vary according to the wind speed, a 6-bridge diode rectifier and a PWM boost chopper is utilized as an ac-dc converter maintaining the constant dc-link voltage with only single switch control. An input current control algorithm for maximum power generation during the variable speed operation is proposed without any usage of speed sensor. Grid connection type PWM inverter converts dc input power to ac output currents into the grid. The active power to the grid is controlled by q-axis current and the reactive power is controlled by d-axis current with appropriate decoupling. The phase angle of utility voltage is detected using software PLL(Phased Locked Loop) in d-q synchronous reference frame. Experimental results from the test of 30kW prototype wind turbine system show that the generator power can be controlled effectively during the variable speed operation without any speed sensor.

A Study on Energy Saving of the Motor Cooling System with an Inverter (INVERTER를 응용한 MOTOR 냉각 제어시스템의 전력절감에 관한 연구)

  • Kim, Ki-Hong;Jung, Jee-Hoon;Kwon, Bong-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.611-613
    • /
    • 2004
  • This paper is concerned with the simulation and determination of the input voltage and frequency for the optimal efficiency operation of induction motors. In general, induction motors have a specific character that operation efficiency is dropped sharply at the light roads condition. Consequently, if the induction motor is controlled by high efficiency using the VVVF(variable voltage variable frequency) control methods at optimal values, the entire system can obtain the substantial energy savings from the efficiency improvement in induction motors. In this paper, optimal slip is derived from the modeling of an induction motor and the optimal hybrid-control method is suggested by the simulation of the proposed algorithm for a 3-phase induction motor.

  • PDF