• Title/Summary/Keyword: vapors

Search Result 170, Processing Time 0.022 seconds

Cholesteric Liquid Crystals as Multi-Purpose Sensor Materials

  • Lisetski, L.N.
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.1
    • /
    • pp.27-30
    • /
    • 2005
  • New possibilities are discussed for cholesteric liquid crystals (CLC) as sensor materials for detection of ionizing radiation, biologically active UV radiation, and the presence of hazardous vapors in atmosphere. A distinguishing property of CLC-based detectors is their 'bioequivalence', i.e., mechanisms of their response to external factors essentially imitate the corresponding mechanisms of biological tissues. Such detectors can ensure sufficiently high sensitivity to make feasible their use as alarm indicators or in biophysical studies. Specific examples ate given of sensor compositions and their response characteristics.

Observation of Penning ionization using the optogalvanic effect

  • Jeong, Kee-Ju;Lee, Jun-Hoi
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.7 no.1
    • /
    • pp.18-22
    • /
    • 2003
  • The optogalvanic effect is proposed and demonstrated as a technique for Penning ionization in a discharge of mixtures of metal vapors and rare gases. The gadolinium and argon mixture is used as a prototype. The lowest metastable of argon, 3P$_2$ (ls$\_$5/ in Paschen notation) at 93144 cm$\^$-1/, is within kT from the excited states of Gd ion. Thus Penning ionization occurs to an excited states of the ion. This process strongly alters the optogalvanic signal and has its own signatures.

  • PDF

Prediction of Service Life of a Respirator Cartridge by the Occupational Environment(II) (작업현장의 환경조건에 따른 방독마스크 정화통의 수명예측(II))

  • 김기환;김덕기;신창섭
    • Journal of the Korean Society of Safety
    • /
    • v.11 no.4
    • /
    • pp.72-78
    • /
    • 1996
  • The breakthrough curves of a sampling tube were studied to predict the service life of a respirator cartridge for organic vapors. The fixed bed adsorption model was applied to respirator cartridge and it's variables were calculated from tile experiment of sampling tube. By the experiment and simulation, it was possible to predict the service life of a respirator cartridge, however, not adequate at low $CCl_4$ concentration less than 700ppm and at high air humidify. The breakthrough curves of sampling tube were irregular compare to that of respirator cartridge due to .packing density.

  • PDF

PAHs Formation Characteristics and Fullerenes $(C_{60},\;C_{70})$ Synthesis in a Low-Pressure $C_6H_6/Ar/O_2$ Flame (저압 $C_6H_6/Ar/O_2$ 화염에서 PAHs 생성 특성 및 플러렌$(C_{60},\;C_{70})$ 합성에 대한 연구)

  • Lee, G.W.;Kim, Y.W.;Hwang, J.;Jrung, J.;Choi, M.
    • Journal of the Korean Society of Combustion
    • /
    • v.7 no.4
    • /
    • pp.36-44
    • /
    • 2002
  • Carbon molecules with closed-cage structures are called fullerenes $(C_{60},\;C_{70})$, whose applications include super-conductors, sensors, catalysts, optical and electronic device, polymer composites, and biological and medical materials. The synthesis of fullerenes has been recently studied with low-pressure benzene/argon/oxygen flames. The formation of fullerene is known as molecular weight growth processes of PAHs (polycyclic aromatic hydrocarbon). This study presents results of PAHs and fullerene measurements performed in a low-pressure benzene/argon/oxygen normal co-flow laminar diffusion flame. Through the central tube of the burner, benzene vapors carried by argon are injected. The benzene vapors are made in a temperature-controlled bubbler. The burner is located in a chamber, equipped with a sampling system for direct collection of condensable species from the flame, and exhausted to a vacuum pump. Samples of the condensable are analyzed by HPLC (High Performance Liquid Chromatography) to determine the yields of PAHs and fullerene. Also, we computed mole fraction of fullerene and PAHs in a nearly sooting low pressure premixed, one-dimensional benzene/argon/oxygen flame (equivalence ratio ${\Phi}=2.4$, pressure=5.33kPa). The object of computation was to investigate the formation mechanism of fullerenes and PAHs. The computations were performed with CHEMKIN/PREMIX. As a result of this study, fullerenes were synthesized in a low pressure (20torr) $C_6H_6/Ar/O_2$ flames and the highest concentration of fullerene was detected just above the visible surface of a flame.

  • PDF

Comparison of Sampling Methods for Determining Airborne Mixture of Organic Solvents (공기중 유기용제 혼합물 측정방법의 비교연구)

  • Chun, Mee Hye;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.1 no.1
    • /
    • pp.16-28
    • /
    • 1991
  • A study on comparison of standard charcoal tube method, infrared gas analyzer, and detector tube method were conducted. Measurements were performed simultaneously at same sampling points in an air chamber containing benzene, toluene and xylene vapors. Charcoal tube samles were collected at sampling flowrates of 0.05, 0.2, 0.5, and 1.0 1pm. Results are as follows : 1. Coefficients of variation of results with charcoal tube method for bezene, toluene and xylene mixture vapor were 14.34 % in benzene(0.28-11.12 ppm), 9.20 % in toluene (2.68-135.09 ppm) and 10.21 % in xylene (2.56-82.64 ppm), respectively. 2. Results of infrared gas analyzer in mixture air were non-specific on benzene and toluene. Ratio of results of infrared gas analyzer to those of charcoal tube on benzene, toluene and xylene were 696.4 %, 30.3 % and 36.6 %, respectively. 3. Ratio of responses of detector tubes to those of charcoal tube were 49.4 % in benzene, 22.1 % in toluene and 223.9 % in xylene. Xylene detector tube were interfered by toluene greately. 4. Collection efficiencies of charcoal tubes at low concentraton(benzene : 1 ppm, toluene : 10 ppm, xylene : 10 ppm) were stable on various flowrate from 0.05 to 1.0 1pm, but at high concentrations the efficiency decreased at high flowrate above 0.5 1pm. 5. Within the saturation capacity of charcoal, collection effiency decreased at 0.5-1.0 1pm. Smpling feowrates of 0.05-0.20 1pm were appropriate for sampling organic vapors.

  • PDF

ZnO thin films with Cu, Ga and Ag dopants prepared by ZnS oxidation in different ambient

  • Herrera, Roberto Benjamin Cortes;Kryshtab, Tetyana;Andraca Adame, Jose Alberto;Kryvko, Andriy
    • Advances in nano research
    • /
    • v.5 no.3
    • /
    • pp.193-201
    • /
    • 2017
  • ZnO, ZnO: Cu, Ga, and ZnO: Cu, Ga, Ag thin films were obtained by oxidization of ZnS and ZnS: Cu, Ga films deposited onto glass substrates by electron-beam evaporation from ZnS and ZnS: Cu, Ga targets and from ZnS: Cu, Ga film additionally doped with Ag by the closed space sublimation technique at atmospheric pressure. The film thickness was about $1{\mu}m$. The oxidation was carried out at $600-650^{\circ}C$ in air or in an atmosphere containing water vapor. Structural characteristics were investigated by X-ray diffraction (XRD) and atomic force microscopy (AFM). Photoluminescence (PL) spectra of the films were measured at 30-300 K using the excitation wavelengths of 337, 405 and 457.9 nm. As-deposited ZnS and ZnS: Cu, Ga films had cubic structure. The oxidation of the doped films in air or in water vapors led to complete ZnO phase transition. XRD and AFM studies showed that the grain sizes of oxidized films at wet annealing were larger than of the films after dry annealing. As-deposited doped and undoped ZnS thin films did not emit PL. Shape and intensity of the PL emission depended on doping and oxidation conditions. Emission intensity of the films annealed in water vapors was higher than of the films annealed in the air. PL of ZnO: Cu, Ga films excited by 337 nm wavelength exhibits UV (380 nm) and green emission (500 nm). PL spectra at 300 and 30 K excited by 457.9 and 405 nm wavelengths consisted of two bands - the green band at 500 nm and the red band at 650 nm. Location and intensities ratio depended on the preparation conditions.

Sampling efficiencies of the activated carbon fiber and 3M diffusive samplers for organic vapors (공기중 유기용제 측정을 위한 활성탄섬유 확산포집기와 3M 확산포집기의 시료포집효율에 대한 연구)

  • Byeon, Sang-Hoon;Oh, Se-Min;Lee, Chang-Ha
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.7 no.1
    • /
    • pp.21-31
    • /
    • 1997
  • Toluene, n-hexane, and methyl ethyl ketone(MEK) were exposed to the activated carbon fiber(ACF) and 3M(Model 3500) diffusive samplers under low and high humidity levels. In order to evaluate these two samplers, the sampling capacity, sampling rate, reverse diffusion, and storage stability were obtained. At low humidity level($8{\pm}3%RH$), the adsorption amount of all three organic vapors to the ACF diffusive sampler showed a positive linear relationship up to 8 hours. However, at high humidity level($90{\pm}5%RH$), n-hexane and MEK maintained a positive linear relationship up to 1.5 hrs, but decreased in their adsorption amounts afterwards. On the other hand, the adsorption amount of n-hexane, MEK, and toluene to 3M diffusive sampler showed almost a positive linear relationship up to 8 hours at both humidity levels. At low humidity level, there was almost no reverse diffusion for both 3M and ACF diffusive samplers. However, when the ACF diffusive sampler was used at high humidity level, there was about 52.63% of MEK sample loss and about 92.59% of n-hexane sample loss. The storage stabilities of the ACF and 3M diffusive samplers were both relative stable except for MEK. In the case of MEK, the difference between the analysis of the organic vapor right after the sampling and that of 3 weeks later at room temperature was 45% for the ACF diffusive sampler and 18% for the 3M diffusive sampler. Since the storage stability of the samples stored in a refrigerator was relatively stable, they need to be refrigerated until the analysis is done.

  • PDF

The Effects of Deposition Temperature of Pt Top Electrodes on the Electrical Properties of PZT Thin Films (Pt 상부 전극 증착온도가 PZR 박막의 전지적 특성에 미치는 영향)

  • Lee, Kang-Woon;Lee, Won-Jong
    • Korean Journal of Materials Research
    • /
    • v.8 no.11
    • /
    • pp.1048-1054
    • /
    • 1998
  • The effects of deposition temperature of Pt top electrodes on the electrical properties of Pb(Zr,Ti))$O_3$, (PZT) thin film were investigated. When the Pt top electrodes were deposited at substrate temperatures of $200^{\circ}C$ or above,the ferroelectric properties of the PZT thin film under the Pt electrode were severely degraded. Whereas those of the PZT film where the Pt electrodes were not deposited were not degraded. Water vapors which remained in the vacuum chamber were dissociated into hydrogen atoms by the catalysis of Pt top electrode, and those hydrogen atoms diffused into the PZT film and produced oxygen vacancies at high substrate temperature, resulting in the degradation of the ferroelectric properties of the PZT film located under the Pt electrode. Since the water vapors could not be dissociated into hydrogen atoms without the catalysis of Pt. the degradation of the PZT film did not take place where the Pt electrode were not deposited. The degraded feroelectric properties could be recovered by rapid thermal annealing (RTA) treatment. On the other hand. leakage current characteristics were improved with increasing the deposition temperature of Pt top electrodes.

  • PDF

Development of a Fission Product Transport Module Predicting the Behavior of Radiological Materials during Severe Accidents in a Nuclear Power Plant

  • Kang, Hyung Seok;Rhee, Bo Wook;Kim, Dong Ha
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.3
    • /
    • pp.237-244
    • /
    • 2016
  • Background: Korea Atomic Energy Research Institute is developing a fission product transport module for predicting the behavior of radioactive materials in the primary cooling system of a nuclear power plant as a separate module, which will be connected to a severe accident analysis code, Core Meltdown Progression Accident Simulation Software (COMPASS). Materials and Methods: This fission product transport (COMPASS-FP) module consists of a fission product release model, an aerosol generation model, and an aerosol transport model. In the fission product release model there are three submodels based on empirical correlations, and they are used to simulate the fission product gases release from the reactor core. In the aerosol generation model, the mass conservation law and Raoult's law are applied to the mixture of vapors and droplets of the fission products in a specified control volume to find the generation of the aerosol droplet. In the aerosol transport model, empirical correlations available from the open literature are used to simulate the aerosol removal processes owing to the gravitational settling, inertia impaction, diffusiophoresis, and thermophoresis. Results and Discussion: The COMPASS-FP module was validated against Aerosol Behavior Code Validation and Evaluation (ABCOVE-5) test performed by Hanford Engineering Development Laboratory for comparing the prediction and test data. The comparison results assuming a non-spherical aerosol shape for the suspended aerosol mass concentration showed a good agreement with an error range of about ${\pm}6%$. Conclusion: It was found that the COMPASS-FP module produced the reasonable results of the fission product gases release, the aerosol generation, and the gravitational settling in the aerosol removal processes for ABCOVE-5. However, more validation for other aerosol removal models needs to be performed.

Adsorption Characteristics of Multi-component VOCs Including Poorly Adsorbable Chemicals on Activated Carbonaceous Adsorbents (비흡착성 화합물을 포함하는 다성분 VOCs의 탄소흡착제 흡착특성)

  • Woo, Kwang Jae;Kim, Sang Do;Lee, Si Hyun
    • Korean Chemical Engineering Research
    • /
    • v.45 no.3
    • /
    • pp.277-285
    • /
    • 2007
  • The adsorption characteristics of multi-component solvent vapors including poorly-adsorbable chemicals such as toluene-xylene-MEK and toluene-MEK-IPA on the activated carbonaceous adsorbents were investigated in a stainless steel fixed bed of 10.2 cm ID and 50 cm in height in order to identify those carbons for eliminating and recovering solvent vapors from industrial emission sources. The used activated carbonaceous adsorbents were pelletized commercial activated carbons and activated carbon fiber. Breakthrough curves and adsorption capacity at atmospheric pressures were obtained. It has been found that non-polar and larger molecules have been adsorbed better than polar and smaller molecules. In special, alcohols and ketones were poorly adsorbed caused by competitive adsorbability in multi-component mixture system. However, it could be overcome by profitable employment of organization of cooperative system which was composed of different porosity activated carbonaceous adsorbents appropriately.