• 제목/요약/키워드: vapors

검색결과 170건 처리시간 0.028초

중소규모 화학공장의 압력방출시스템에 대한 안전성 검토 (Review of Safety for Pressure-Relieving Systems of Small to Middle Scale Chemical Plants)

  • 임지표;진대영;마병철;강성주;정창복
    • 한국안전학회지
    • /
    • 제30권6호
    • /
    • pp.48-55
    • /
    • 2015
  • A variety of safety issues were investigated for chemical reactors using a toluene solvent in case of a fire at small to middle scale chemical plants. The issues covered the operation of pressure-relieving valves and the subsequent discharges of the toluene to the atmosphere either directly or through an absorber, which represent the current practice at most small chemical plants. It was shown that the safety valve on the reactor may not operate within about twenty minutes after an external fire breaks out, but, once relieved, the toluene vapor released directly to the atmosphere may form a large explosion range on the ground. It was also shown that if the discharge is routed to an existing absorber used for the scrubbing of volatile organic compounds or dusts, the column may not operate normally due to excessive pressure drops or flooding, resulting in the hazardous release of toluene vapors. This study proposed two ways of alleviating these risks. The first is to ruduce the discharge itself from the safety valve by using adequate insulation and protection covers on the reactor and then introduce it into the circulation water at the bottom of the absorber through a dip linet pipe equipped with a ring-shaped sparger. This will enhance the condensation of toluene vapors with the reduced effluent vapors treated in the packing layers above. The second is to install a separate quench drum to condense the routed toluene vapors more effectively than the existing absorber.

Chemical Sensors Based on Distributed Bragg Reflector Porous Silicon Smart Particles

  • Sohn, Honglae
    • 통합자연과학논문집
    • /
    • 제8권1호
    • /
    • pp.67-74
    • /
    • 2015
  • Sensing characteristics for porous smart particle based on DBR smart particles were reported. Optically encoded porous silicon smart particles were successfully fabricated from the free-standing porous silicon thin films using ultrasono-method. DBR PSi was prepared by an electrochemical etch of heavily doped $p^{++}$-type silicon wafer. DBR PSi was prepared by using a periodic pseudo-square wave current. The surface-modified DBR PSi was prepared by either thermal oxidation or thermal hydrosilylation. Free-standing DBR PSi films were generated by lift-off from the silicon wafer substrate using an electropolishing current. Free-standing DBR PSi films were ultrasonicated to create DBR-structured porous smart particles. Three different surface-modified DBR smart particles have been prepared and used for sensing volatile organic vapors. For different types of surface-modified DBR smart particles, the shift of reflectivity mainly depends on the vapor pressure of analyte even though the surfaces of DBR smart particles are different. However huge difference in the shift of reflectivity depending on the different types of surface-modified DBR smart particles was obtained when the vapor pressures are quite similar which demonstrate a possible sensing application to specify the volatile organic vapors.

근관치료(根管治療)에 사용(使用)되는 수종(數種) 약물(藥物)의 살균효과(殺菌效果)에 관(關한) 실험적(實驗的) 연구(硏究) (AN IN VITRO STUDY OF ANTIMICROBIAL EFFECT OF INTRACANAL DISINFECTANTS)

  • 정충모
    • Restorative Dentistry and Endodontics
    • /
    • 제1권1호
    • /
    • pp.43-49
    • /
    • 1975
  • This study was divided into two parts. In the first experiment, the in vitro antimicrobial effect was tested in order to evaluate the effect of vapors, and the effectiveness of the nonspecific endodontic medicaments (formocresol, camphorated parachlorophenol and eugenol). In the second experiment, the intracanal effect was tested in vitro under simulated clinical condition. The actual bactericidal effect of the nonspecific endodontic medicaments (formocresol, camphorated parachlorophenol and eugenol) was quantitated. The results were obtained as follows: 1. The zone of inhibition was appeared on the vapors of formocresol only, however there were no zone of inhibition appeared on the vapors of camphorated parachlorophenol and eugenol. 2. Formocresol produced the widest zone of inhibition and eugenol, the next and camphorated parachlorophenol, the narrowest. 3. All of the tested medicaments were vaporized in the root canal. They proved to be the effective antimicrobial activity in the root canal. 4. All of the tested medicaments were showed more bactericidal effect at 72 hours than 48 hours. 5. In comparing with the bactericidal effect of the tested medicaments in the root canal, formocresol was showed the most bactericidal medicament, camphorated parachlorophenol was showed the least. 6. Complete sterilization of the root canal was not achieved in any medicaments applied in this study.

  • PDF

확산 포집기로 공기중 혼합유기용제 포집시 온도와 상대습도가 포집효율에 미치는 영향 (Effects of temperature and relative humidity on the sampling efficiencies of mixed organic vapors measured by diffusion monitors)

  • 한진구;노영만;김현욱
    • 한국산업보건학회지
    • /
    • 제5권2호
    • /
    • pp.200-211
    • /
    • 1995
  • This study was designed to evaluate the effects of temperature and humidity on the sampling efficiency of mixed organic vapors of l,2-DCE, benzene, and MIBK by 3 different types of diffusion monitors. Independent variables used for the study were temperatures ($25^{\circ}C$, $35^{\circ}C$), humidities (30%, 80%), and vapor concentrations (low, medium, and high). In addition, vapor concentrations measured by the traditional charcoal tube method were used as reference values and were compared with those of by diffusion monitors. The results were as follows: 1. The desorption efficiencies(DE) of 1,2-DCE and benzene from charcoal tubes and from diffusion monitors ranged from 98% to 105%. In contrast, the DEs of MIBK from charcoal tubes and diffusion monitors except DM1 ranged from 71% to 85%. The DE of MIBK from DM1 was 98%. 2. No statistically significant differences of 1,2-DCE concentrations and the sampling efficiencies regardless of temperatures and humidities studied between charcoal tube and 3 diffusion monitors were found. 3. At 80% humidity, increasing frequencies of 1,2-DCE breakthrough at higher temperature and higher vapor concentration measured by charcoal tubes were observed. 4. No statistically significant difference of benzene concentrations were found between charcoal tube and diffusion monitors except DM3. The sampling efficiencies of DM3 were statistically significantly lower at all experimental conditions except the $35^{\circ}C$ and 30% humidity condition. 5. No statistically significant difference of MIBK concentrations were found between charcoal tube and diffusion monitors except DM3. The sampling efficiencies of DM3 were statistically significantly higher at higher humidity conditions regardless of temperature. Although statistically not significant, sampling efficiency of MIBK showed positive correlation with humidity while negative correlation with concentration was observed. 6. For sampling 1,2-DCE and benzene, no significant variations of concentrations among three diffusion monitors regardless of temperature and humidity conditions were found. For MIBK sampling, however, wide variations with increasing humidity among diffusion monitors were obtained. In conclusion, this study suggests that diffusion monitors will be a reasonables substitute for the traditional charcoal tubes for sampling non-polar organic vapors at temperature and humidity conditions studied. For polar organic vapors, use of an alternative desorption solution other than CS2 is recommended because of its low desorption efficiency. In addition, since variable among diffusion monitors for polar organic vapors particularly at higher humidity conditions were observed, further study is recommended of the effects of humidity on the performance of diffusion monitors.

  • PDF

공기중 유기용제 농도 측정에 있어서 국산 확산포집기와 활성탄관의 비교연구 (Field Comparison of Korean Diffusive Sampler and Charcoal Tube Methods for Determination of Organic Vapors)

  • 조숙자;백남원
    • 한국산업보건학회지
    • /
    • 제7권1호
    • /
    • pp.33-48
    • /
    • 1997
  • Korean diffusive sampler (KDS) and charcoal tube (CT) were used for sampling n-hexane, trichloroethylene and toluene in air KDS was made by Department of Environmental Health, SNU-SPH in 1995. Surveys were conducted at ten industrial plants with organic solvents. The relationship between two sampling methods was examined by linear regression analysis, and concentrations by two sampling methods were compared using paired t-test. The results are as follows: 1. The geometric means by CT and KDS methods were 3.26ppm and 3.32ppm for n-hexane, 5.07ppm and 6.34ppm for toluene, and 7.18ppm and 7.90ppm for toluene, respectively. There was no significant difference between results by CT and KDS methods in three organic vapors (p>0.05). When linear regression analysis was performed, two sampling methods were highly related ; correlation coefficients were 0.98, 0.90 and 0.96 for n-hexane, toluene and trichloroethylene, respectively. 2. Airborne concentrations of n-hexane (n=21) were below 0.5 TLV level. The GM by two methods were almost same (3.09 ppm). And there was no significant difference between results by two methods (p>0.05). 3. Since toluene and trichloroethylene concentrations showed several levels, appropriate sampling rates were applied for each level. The GM of toluene concentrations by two methods at 0.5 TLV level were 3.75ppm and 5.48ppm. The KDS method overestimated the toluene concentrations at 0.5 TLV level (p<0.05). The GM values of toluene concentrations at 1 TLV level were 31.80ppm and 25.38ppm and at 2 TLV level were 64.13 ppm and 51.37 ppm. The KDS method underestimated concentration at both level (p<0.05). For trichloroethylene, the GM at 0.5 TLV level were 4.97 ppm and 7.11ppm. The KDS method overestimated the concentration of trichloroethylene (p<0.05). In conclusion, concentrations of three organic vapors measured by CT and KDS were not significantly different and results by two methods were highly related. But at contain concentrations, the levels by method were significantly different. Therefore, it is suggested that sampling rate of KDS should be studied simultaneously using CT method for organic vapors.

  • PDF

향끽미종 잎담배 성분조성에 관한 연구 II. 헤드스페이스 휘발성 유기성분의 특성 조사 (Composition Studies on the Aromatic Tobacco Varieties (Nicotiana tabacum L. ) : II. Characteristics of Headspace Vapors)

  • 김경례;이운철
    • 한국연초학회지
    • /
    • 제3권1호
    • /
    • pp.1-10
    • /
    • 1981
  • 5가지 향끽미종 잎담배의 헤드스페이스 휘발성 성분들을 중합체 흡착방법 및 고성능 유리 캐피러리 가스 크로마토그라피로 분석하였다. 얻어진 가스 크로마토그라피의 프로파일을 비교한 결과 각 담배 시료는 독특한 방향성분의 조성을 보여주며 주요성분의 정량적인 차이가 현저함이 확인되었다.

  • PDF

Corrosion of Alumina-Chromia Refractory by Alkali Vapors: 1. Thermodynamic Approach

  • Lee, Kyoung-Ho;Jesse J. Brown Jr
    • The Korean Journal of Ceramics
    • /
    • 제1권1호
    • /
    • pp.29-34
    • /
    • 1995
  • Theoretical predictions were made for thermodynamically stable phases which formed when alkali(sodium and Potassium) vapors reacted with the 90% $Al_2O_3$-10% $Cr_2O_3$ refractory under coal gasifying atmosphere using the computer program of SOLGASMIX-PV. The calculation results showed that the stable compounds that formed were $X_2O$.$Al_2O_3$ and $X_2O$.$llAl_2O_3$(X=$Na^+$ or $K^+$), depending upon the alkali concentration. The presence of sulfur in gasifying atmospheres did not appear to affect the species of alkali reaction products. Alkali attack at high temperatures is likely to cause serious degradation at the hot face of the refractory, indicating that the alkali concentration is an important factor to affect the degradation of the refroctory.

  • PDF

서울 동부지역내 작업장 공기질에 관한 조사 연구 (A Study of Workplace Air Quality in the Eastern Seoul)

  • 임창훈;황인조;김동술;김윤신
    • 한국대기환경학회지
    • /
    • 제15권3호
    • /
    • pp.235-247
    • /
    • 1999
  • This study was performed to investigate what was the most serious occupational factors in small scale industries. Twenty-three occupatonally hazardous substances were measured at the five workplaces in the Eastern Seoul during 1995∼1996. Total of 2,020 samples were analyzed by either GC/FID for organic vapors or AAS for heavy metals. From the results of this study noise was the most serious factor at the selected workplaces. Noise level in the metal processing, the printing, and the auto repairing industries exceeded the 8 hr PEL by 19.7%, 13.6%, and 11.6%, respectively. Mean concentrations of toluene in the shoe making and the printing industries exceeded the assessment crieterion by 6.0% and 3.8%, respectively. Further study of risk assessment of occupational exposure may be required to protect workers from hazardous working conditons.

  • PDF

Simulated Study on Typical Sources of Volatile Organic Compounds (VOCs) in Indoor Air

  • Dai, Shugui;Bai, Zhipeng;Zhu, Tan;Zhang, Lin
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.745-751
    • /
    • 1995
  • In this paper, several simulated devices were constructed for determining components of organic vapors emitting from decorative materials, daily use chemicals and from common behavior of human beings, such as smoking and cooking. The VOCs were preconcentrated on activated carbon and then desorbed by carbon disulphide. The results were obtained by GC/MS analysis and computer searching. It can be concluded that the categories of the sources and the components of organic vapors in indoor air are very complicated, and different sources of VOCs in indoor air have their own emission characteristics.

  • PDF

Selection of a carrying agent for obtaining radioactive methyliodide vapors under dynamic conditions

  • Obruchikov, Alexander V.;Merkushkin, Aleksei O.;Magomedbekov, Eldar P.;Anurova, Olga M.;Vanina, Elena A.
    • Nuclear Engineering and Technology
    • /
    • 제53권8호
    • /
    • pp.2761-2766
    • /
    • 2021
  • A method for preparing "reagent" for radioactive methyliodide vapors production using an isotopic exchange reaction has been developed. Based on the obtained data of the isotopic exchange efficiency and hydraulic resistance, white fused alumina (700-840 ㎛) was selected as the carrying agent material for "reagent" production. The radioiodine isotopic exchange dependences on such parameters as temperature, gas flow velocity, and the methyliodide concentration in it were determined. Optimal conditions have been selected to achieve 85% of the isotopic exchange rate in 1 h of the experiment. The obtained data allowed to develop an approach to the test of iodine filters for nuclear power plants and to determine their efficiency.