• Title/Summary/Keyword: vapor liquid equilibrium

Search Result 107, Processing Time 0.028 seconds

A Study on the Boundary Layer Thickness at a Liquid-Vapor Interface (기액계면의 경계층 두께에 관한 연구)

  • Choi, Soon-Ho;Song, Chi-Sung;Choi, Hyun-Kyu;Lee, Jung-Hye;Kim, Kyung-Kun
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1086-1091
    • /
    • 2004
  • The boundary layer is a very important characteristic of a liquid-vapor interface since it governs the heat and mass transfer phenomena across an interface. However, the thickness of a boundary layer is generally micro- or nano-sized, which requires highly accurate measurement devices and, consequently, costs the related experiments very high and time-consuming. Due to these size dependent limitations, the experiments related with a nano-scaled size have suffered from the errors and the reliability of the obtained data. This study is performed to grasp the characteristics of a liquid-vapor interface, by using a molecular dynamics method. The simulation results were compared with other studies if possible. Although other studies reported that there existed a temperature discontinuity over an interface when the system was reduced to micro- or nano-sized, we confirmed that there was no such a temperature discontinuity.

  • PDF

Sensitivity of EOS in Analyzing the High-Pressure Vaporization Characteristics (고압 상태의 증발 특성 해석결과에 미치는 상태방정식의 영향)

  • You, Y.W.;Kim, Y.M.
    • Journal of ILASS-Korea
    • /
    • v.2 no.3
    • /
    • pp.32-43
    • /
    • 1997
  • A comparison of predicted molar volume, vapor - liquid equilibrium, enthalpy of vaporization, droplet size history. and vaporization rates with several forms of equation of state has been made. The equation of state (EOS) investigated in this study includes the EOS given by Redlich - Kwong, the Soave - Redlich - Kwong, and the Peng - Robinson. Numerical results indicate that the Peng - Robinson EOS yields more accurate predictions of vapor - liquid equilibrium under a broader range of temperature and pressure conditions, especially at high pressures and near the critical point.

  • PDF

Study on the Equilibrium Point of Heat and Mass Transfer between Liquid Desiccant and Humid Air with in the Solar Air Conditioning System

  • Sukmaji, I.C.;Rahmanto, H.;Agung, B.;Choi, K.H.;Kim, J.R.
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.161-167
    • /
    • 2009
  • The liquid solar air conditioning system is introduced as an alternative solution to control air condition and to save electrical energy consumption. The heat and mass transfer performances of dehumidifier/regenerator in liquid solar air conditioning system are influenced by air and desiccant condition. The application of this system, the thermal energy from the sun and inlet air are unable to control, but operation parameter of other components such as pump, fan and sensible cooling unit are able to control. The equilibrium point of heat and mass transfer are the liquid desiccant and inlet air conditions, where, the heat and mass are not transferred between the liquid desiccant and vapor air. By knowing equilibrium point of heat and mass transfer, the suitable optimal desiccant conditions for certain air condition are funded. This present experiment study is investigated the equilibrium point heat and mass transfer in various air and desiccant temperature. The benefit of equilibrium point heat and mass transfer will be helpful in choose and design proper component to optimize electrical energy consumption.

  • PDF

Simulation of a Leakage Process of Refrigerant Mixtures (혼합냉매의 누출과정에 관한 시뮬레이션)

  • Kim, M.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.3
    • /
    • pp.217-225
    • /
    • 1993
  • Nonflammable mixtures of flammable and nonflammable refrigerants are possible as substitute refrigerants for use in domestic heat pumps and refrigerators. Refrigerant leakage from such a system is of paramount concern since it is possible that the resulting mixture composition remaining in system will reside in the flammable range. This paper presents a simulation of a leakage process of refrigerant mixtures. Idealized cases of isothermal leakage process are considered in this study representing a slow leak. Simulation is performed for selected composition of binary and ternary refrigerant mixture; R-32/134a and R-32/125/134a. Mixture compositions with respect to percentage leak of original charge are presented. In isothermal leakage process, both vapor and liquid compositions of more volatile refrigerant decrease during vapor and liquid leak, but the total composition of this component decreases during vapor leak and increases during liquid leak. Vapor and liquid compositions are determined depending on the vapor-liquid equilibrium relation of the refrigerant mixture. The refrigerant mixture left in the system can go to a nonflammable direction relying on which component in the mixture is flammable.

  • PDF

Measurements and Correlations of Isobaric Vapor-Liquid Equilibrium for Glycerol-Water Systems (Glycerol-물 계에 대한 등압 기액평형의 측정과 상관관계)

  • Rho, Seon-Gyun;Kang, Choon-Hyoung
    • Applied Chemistry for Engineering
    • /
    • v.8 no.6
    • /
    • pp.893-900
    • /
    • 1997
  • In this study, vapor-liquid equilibria of a binary system, which consists of glycerol and water, are measured using a vaporrecirculating modified Othmer still at various subatmospheric pressures. The constituent components of the binary system considered in this study exhibit a large difference in the boiling temperatures. Since it is generally observed that the properties of a mixture greatly differ from those of the pure components, the phase equilibrium characteristics of a mixture can not be predicted from the properties of the pure components. Furthermore, an abrupt increase in the boiling temperature occurs as the concentration of the higher boiling component exceeds a certain value. Therefore, it is essential to acquire realistic phase equilibrium data of the mixture for industrial applications. Using the UNIQUAC model, the experimental vapor-liquid equilibrium data are correlated with good accuracy. The thermodynamic consistency test is also performed to ensure soundness of the data.

  • PDF

Vaporization of Hydrocarbon Fuel Droplet in High Pressure Environments (고압 환경하에서 탄화수소 연료 액적의 기화특성 연구)

  • Kim, Sung-Yup;Yoon, Woong-Sup
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.127-132
    • /
    • 2003
  • A study of high-pressure n-heptane droplet vaporization is conducted with emphasis placed on equilibrium at vapor-liquid interface. General frame of previous rigorous model[1] is retained but tailored for flash equilibrium calculation of vapor-liquid interfacial thermodynamics. The model is based on complete time-dependent conservation equations with a full account of variable properties and vapor-liquid interfacial thermodynamics. The influences of high-pressure phenomena, including ambient gas solubility, thermodynamic non-ideality, and property variation on the droplet evaporation are investigated. The governing equations and associated moving interfacial boundary conditions are solved numerically using a implicit scheme with the preconditioning method and the dual time integration technique. And a parametric study of entire droplet vaporization history as a function of ambient pressure, temperature has been conducted. Some computational results are compared with Sato's experimental data for the validation of calculations. For low ambient temperatures, the droplet lifetime first increases with pressures, then decreases for high pressures. For higher ambient temperatures, the droplet lifetime increase with less amplitude than that of low ambient temperatures, which then decreases with more amplitude than that of low temperatures. The solubility of nitrogen can not be neglected in the high pressure and it becomes higher as the pressure goes up.

  • PDF

A study for an association of acetic acid with n-heptane based on the chemical theory (초산과 n-heptane 이성분계의 회합성에 대한 화학적 이론을 이용한 연구)

  • Hong Sungho;Lee Jinyub;Lee Taejong
    • Journal of the Korean Institute of Gas
    • /
    • v.3 no.3 s.8
    • /
    • pp.34-38
    • /
    • 1999
  • To propose a model equation, an acetic acid and n-heptane binary vapor liquid equilibrium system were investigated at 298.15K and 318.15K. Pressure was theoretically estimated using an association model based on the chemical theory, in conjunction with Margules, Wilson, NRTL models. Results were compared with those of calculated values without considering association. The theoretically calculated results of association model equations show a good agreement with the experimentally observed values.

  • PDF

Residual Liquid Behavior Calculation for Vacuum Distillation of Multi-component Chloride System (다성분 염화물계 진공 증류의 잔류 액체 거동 계산)

  • Park, Byung Heung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.12 no.3
    • /
    • pp.179-189
    • /
    • 2014
  • Pyroprocessing has been developed for the purpose of resolving the current spent nuclear fuel management issue and enhancing the recycle of valuable resources. An electrolytic reduction of the pyroprocessing is a process to reduce oxides into metals using LiCl as an electrolyte and requires a post-treatment process due to the inclusion of residual salt in porous metal products. A vacuum distillation has been adopted for various molten salt systems and could be applied to the post-treatment process of the electrolytic reduction. The residual salt in the metal products includes LiCl, alkali chlorides, and alkaline earth chlorides. In this paper, vapor pressures of chlorides have been estimated and the composition changes on the residual liquid during the vacuum distillation process have been calculated. A model combining a material balance and vapor-liquid equilibrium relations has been proposed under a constant vapor discharging flow rate and liquid composition changes have been calculated using the vapor pressures with respect to a dimensionless time. The behaviors have been compared with temperature and molten salt composition changes to simulate the process condition variation. The distillation of the residual salt has been dominated by LiCl which is the main component of the salt and CsCl of which vapor pressure is higher than that of LiCl would be readily removed. RbCl exhibits similar vapor pressure with LiCl and maintains its composition. However, $SrCl_2$ and $BaCl_2$ of which vapor pressures are much lower than that of LiCl are concentrated with time and expected to be possibly precipitated during the distillation when the initial compositions are increased.

Estimation of Thermodynamic Properties of Refrigerant Mixtures Using a Modified Carnaha-Starling Equation of State (수정된 Carnahan-Starling 상태방정식을 이용한 혼합냉매의 물성계산)

  • 김민수;김동섭;노승탁
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.6
    • /
    • pp.2189-2205
    • /
    • 1991
  • Thermodynamic properties of binary nonazeotropic refrigerant mixtures are estimated by using a modified Carnhan-Starling equation of state. In this study, pure component refrigerants such as R14, R23, R13, R13 B1, R22, R12, R134a, R152a, R142b, RC318, R114, R11, R123 and R113 are chosen and the thermodynamic properties of enthalpy and entropy are calculated in terms of relevant variables. The modified Carnahan-Starling equation of state is compared with the carnahan-Staring-De Santis equation of sate. Results show that the relative errors become slightly smaller with the equation of state proposed in this study. Correlations are obtained for the mixtures of which the vapor liquid equilibruim data are available to us in the literature. Those mixtures are R14/R23, R23/R12, R13/R12, R13/R11, R13B1/R22, R13B1/RC318, R12/RC138, R12/R114 and R12/R11. The binary interaction coefficients are found under the condition of minimizing the pressure deviations at the vapor liquid equiblibrium state and the estimation of the vapor liquid equilibrium for the refrigerant mixtures is done. Pressure-enthalpy and temperature-entropy diagrams are plotted for the refrigerant mixtures of specific composition.