• 제목/요약/키워드: validation range

검색결과 723건 처리시간 0.026초

Validation of Radioanalytical Techniques for Nuclear Waste Characterisation

  • Warwick, Phillip E.
    • 방사성폐기물학회지
    • /
    • 제17권4호
    • /
    • pp.363-373
    • /
    • 2019
  • Waste characterisation associated with nuclear site decommissioning relies on radiochemical analysis of a diverse range of sample types, requiring extensive validation of analytical techniques using matrix-matched materials. The absence of relevant reference materials has hindered robust method development and validation. The paper discusses how method validation in support of nuclear waste characterisation can be achieved without using reference materials. The key stages in an analytical procedure are evaluated and a multi-stage approach is proposed with the ultimate aim of determining an operational envelope for an analytical procedure.

The Precision Validation of the Precise Baseline Determination for Satellite Formation

  • Choi, Jong-Yeoun;Lee, Sang-Jeong
    • Journal of Astronomy and Space Sciences
    • /
    • 제28권1호
    • /
    • pp.63-70
    • /
    • 2011
  • The needs for satellite formation flying are gradually increasing to perform the advanced space missions in remote sensing and observation of the space or Earth. Formation flying in low Earth orbit can perform the scientific missions that cannot be realized with a single spacecraft. One of the various techniques of satellite formation flying is the determination of the precise baselines between the satellites within the formation, which has to be in company with the precision validation. In this paper, the baseline of Gravity Recovery and Climate Experiment (GRACE) A and B was determined with the real global positioning system (GPS) measurements of GRACE satellites. And baseline precision was validated with the batch and sequential processing methods using K/Ka-band ranging system (KBR) biased range measurements. Because the proposed sequential method validate the baseline precision, removing the KBR bias with the epoch difference instead of its estimation, the validating data (KBR biased range) are independent of the data validated (GPS-baseline) and this method can be applied to the real-time precision validation. The result of sequential precision validation was 1.5~3.0 mm which is similar to the batch precision validation.

Quantitation and Validation of Atorvastatin using HPLC-UV

  • Heine, Daniel;Yong, Chul-Soon;Kim, Jung-Sun
    • Journal of Pharmaceutical Investigation
    • /
    • 제37권3호
    • /
    • pp.187-192
    • /
    • 2007
  • A reversed phase HPLC analysis of atorvastatin (AS) standard solution was performed using diclofenac (DF) as internal standard. Column oven temperature, flow rate and the composition of the mobile phase were varied in order to determine a practical system setup using a C18 column and UV detector. Two C18 columns of different length were compared regarding their influence on the AS peak shape. Based on these preliminary experiments a validation study was performed utilizing a C18 column at $62^{\circ}C$ with a mobile phase consisting of sodium phosphate buffer (0.05 M, pH 4.0), methanol and acetonitrile (40:50:10, v/v/v). The detection limit for AS was $0.1{\mu}g/ml$ and inter- and intra-day calibration curves were linear over a concentration range of $0.2-50{\mu}g/ml$. Accuracy and precision were satisfactory in the AS concentration range of $0.5-50{\mu}g/ml$.

The applicability study and validation of TULIP code for full energy range spectrum

  • Wenjie Chen;Xianan Du;Rong Wang;Youqi Zheng;Yongping Wang;Hongchun Wu
    • Nuclear Engineering and Technology
    • /
    • 제55권12호
    • /
    • pp.4518-4526
    • /
    • 2023
  • NECP-SARAX is a neutronics analysis code system for advanced reactor developed by Nuclear Engineering Computational Physics Laboratory of Xi'an Jiaotong University. In past few years, improvements have been implemented in TULIP code which is the cross-section generation module of NECP-SARAX, including the treatment of resonance interface, considering the self-shielding effect in non-resonance energy range, hyperfine group method and nuclear library with thermal scattering law. Previous studies show that NECP-SARAX has high performance in both fast and thermal spectrum system analysis. The accuracy of TULIP code in fast and thermal spectrum system analysis is demonstrated preliminarily. However, a systematic verification and validation is still necessary. In order to validate the applicability of TULIP code for full energy range, 147 fast spectrum critical experiment benchmarks and 170 thermal spectrum critical experiment benchmarks were selected from ICSBEP and used for analysis. The keff bias between TULIP code and reference value is less than 300 pcm for all fast spectrum benchmarks. And that bias keeps within 200 pcm for thermal spectrum benchmarks with neutron-moderating materials such as polyethylene, beryllium oxide, etc. The numerical results indicate that TULIP code has good performance for the analysis of fast and thermal spectrum system.

유효한 XML 문서에 대한 경계 로킹에 기반한 시퀀스 그룹 검증 기법 (Sequence Group Validation based on Boundary Locking for Valid XML Documents)

  • 최윤상;박석
    • 한국정보과학회논문지:데이타베이스
    • /
    • 제32권6호
    • /
    • pp.628-640
    • /
    • 2005
  • 많은 웹 응용 영역에 XML이 적용되면서 트랜잭션의 변경과 접근에 대한 고립성을 만족시키는 XML 문서에 대한 병행수행은 중요한 이슈가 되고 있다. DTD(혹은 XML 스키마)의 규칙을 잘 지키는 문서를 유효한 XML 문서라 하는데, 유효한 XML 문서에 대한 갱신 연산은 연산 후의 XML 문서가 원래 DTD의 규칙을 그대로 유지해야하는 유효성 문제를 앉고 있다. 일반적인 유효성 검증 방법은 갱신 후의 XML 문서 전체에 대해 유효성을 검증하는 방법이다. 그러나, 위에서 언급한 유효성 검증 방법은 낮은 병행수행의 결과를 낳는다. 따라서, XML 문서의 유효성 검증 범위를 최소화하면서 높은 병행수행 정도를 보이는 새로운 유형성 검증 방법과 로킹 방법이 요구된다. 본 논문은 유효성 검증의 검증 범위를 최소화 시켜 유효성 검증이 효율적으로 수행될 수 있는 시퀀스 그룹 검증 기법을 제안한다. 또한 이 검증 기법의 정확성을 보장하면서 로킹되는 데이타 아이템의 수를 최소화 할 수 있는 경계 로킹 기법을 제안한다. 마지막으로 제안된 유효성 검증 기법과 경계 로킹 기법이 기존의 방법에 비해 트랜잭션의 병행수행 성능을 향상시키고 있음을 실험을 통해 보인다.

딥러닝을 이용한 당뇨성황반부종 등급 분류의 정확도 개선을 위한 검증 데이터 증강 기법 (Validation Data Augmentation for Improving the Grading Accuracy of Diabetic Macular Edema using Deep Learning)

  • 이태수
    • 대한의용생체공학회:의공학회지
    • /
    • 제40권2호
    • /
    • pp.48-54
    • /
    • 2019
  • This paper proposed a method of validation data augmentation for improving the grading accuracy of diabetic macular edema (DME) using deep learning. The data augmentation technique is basically applied in order to secure diversity of data by transforming one image to several images through random translation, rotation, scaling and reflection in preparation of input data of the deep neural network (DNN). In this paper, we apply this technique in the validation process of the trained DNN, and improve the grading accuracy by combining the classification results of the augmented images. To verify the effectiveness, 1,200 retinal images of Messidor dataset was divided into training and validation data at the ratio 7:3. By applying random augmentation to 359 validation data, $1.61{\pm}0.55%$ accuracy improvement was achieved in the case of six times augmentation (N=6). This simple method has shown that the accuracy can be improved in the N range from 2 to 6 with the correlation coefficient of 0.5667. Therefore, it is expected to help improve the diagnostic accuracy of DME with the grading information provided by the proposed DNN.

Unsupervised learning algorithm for signal validation in emergency situations at nuclear power plants

  • Choi, Younhee;Yoon, Gyeongmin;Kim, Jonghyun
    • Nuclear Engineering and Technology
    • /
    • 제54권4호
    • /
    • pp.1230-1244
    • /
    • 2022
  • This paper proposes an algorithm for signal validation using unsupervised methods in emergency situations at nuclear power plants (NPPs) when signals are rapidly changing. The algorithm aims to determine the stuck failures of signals in real time based on a variational auto-encoder (VAE), which employs unsupervised learning, and long short-term memory (LSTM). The application of unsupervised learning enables the algorithm to detect a wide range of stuck failures, even those that are not trained. First, this paper discusses the potential failure modes of signals in NPPs and reviews previous studies conducted on signal validation. Then, an algorithm for detecting signal failures is proposed by applying LSTM and VAE. To overcome the typical problems of unsupervised learning processes, such as trainability and performance issues, several optimizations are carried out to select the inputs, determine the hyper-parameters of the network, and establish the thresholds to identify signal failures. Finally, the proposed algorithm is validated and demonstrated using a compact nuclear simulator.

RAPID PREDICTION OF ENERGY CONTENT IN CEREAL FOOD PRODUCTS WITH NIRS.

  • Kays, Sandra E.;Barton, Franklin E.
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1511-1511
    • /
    • 2001
  • Energy content, expressed as calories per gram, is an important part of the evaluation and marketing of foods in developed countries. Currently accepted methods of measurement of energy by U.S. food labeling legislation include measurement of gross calories by bomb calorimetry with an adjustment for undigested protein and by calculation using specific factors for the energy values of protein, carbohydrate less the amount of insoluble dietary fiber, and total fat. The ability of NIRS to predict the energy value of diverse, processed and unprocessed cereal food products was investigated. NIR spectra of cereal products were obtained with an NIR Systems monochromator and the wavelength range used for analysis was 1104-2494 nm. Gross energy of the foods was measured by oxygen bomb calorimetry (Parr Manual No. 120) and expressed as calories per gram (CPGI, range 4.05-5.49 cal/g). Energy value was adjusted for undigested protein (CPG2, range 3.99-5.38 cal/g) and undigested protein and insoluble dietary fiber (CPG3, range 2.42-5.35 cal/g). Using a multivariate analysis software package (ISI International, Inc.) partial least squares models were developed for the prediction of energy content. The standard error of cross validation and multiple coefficient of determination for CPGI using modified partial least squares regression (n=127) was 0.060 cal/g and 0.95, respectively, and the standard error of performance, coefficient of determination, bias and slope using an independent validation set (n=59) were 0.057 cal/g, 0.98, -0.027 cal/g and 1.05 respectively. The PLS loading for factor 1 (Pearson correlation coefficient 0.92) had significant absorption peaks correlated to C-H stretch groups in lipid at 1722/1764 nm and 2304/2346 nm and O-H groups in carbohydrate at 1434 and 2076 nm. Thus the model appeared to be predominantly influenced by lipid and carbohydrate. Models for CPG2 and CPG3 showed similar trends with standard errors of performance, using the independent validation set, of 0.058 and 0.088 cal/g, respectively, and coefficients of determination of 0.96. Thus NIRS provides a rapid and efficient method of predicting energy content of diverse cereal foods.

  • PDF

장거리 대기 확산모델 검증 (Validation of the Long-Range Atmospheric Dispersion Model)

  • 서경석;김은한;황원태;정효준;한문희
    • Journal of Radiation Protection and Research
    • /
    • 제31권1호
    • /
    • pp.9-15
    • /
    • 2006
  • 대기 중으로 방출된 방사성 물질의 이동 확산 현상을 이해하기 위하여 장거리 대기 확산 모델 LADAS가 개발되었다 개발된 수치모델의 검증을 위하여 ETEX 장거리 확산실험 결과와 비교하였다. 비교결과 LADAS모델 내 혼합층 높이를 일정하게 준 경우보다 Richardson number를 이용하여 혼합층 높이를 계산한 결과가 관측 값에 가장 근접함을 알 수 있었다. 또한 일부 포집 지점에서 관측된 농도의 시계열 자료와 비교한 바 계산 값은 어느 정도 일치하고 있었다.

LC-MS/MS를 이용한 반려동물 사료에서 곰팡이독소 동시분석법 유효성 확인 (Validation of simultaneous mycotoxin analysis method in pet food using LC-MS/MS)

  • 최윤화;안우석;김지은;김두환
    • 한국동물위생학회지
    • /
    • 제45권3호
    • /
    • pp.237-242
    • /
    • 2022
  • The simultaneous analysis of mycotoxins using LC-MS/MS, a food official analysis method, was applied with compound feed for pets with high consumer preferences. In this study, the linearity of all calibration curves showed good linearity of 0.99 or more. and both the accuracy (recovery rate) and precision (repeatability) criteria of the concentration range for each mycotoxin in the National Agricultural Products Quality Management Service's Validation and Verification Guidelines were met. And as a result of analyzing FAPAS QCM in the same way, it was assesed that the z-scores of Aflatoxin B1, Ochratoxin A, Zearalenone, and Fumonisin B1, were within ±2 range. This study showed that the application of the food official analysis method to compound feed for pets is suitable.