• Title/Summary/Keyword: usefulness

Search Result 8,282, Processing Time 0.048 seconds

Medical Information Dynamic Access System in Smart Mobile Environments (스마트 모바일 환경에서 의료정보 동적접근 시스템)

  • Jeong, Chang Won;Kim, Woo Hong;Yoon, Kwon Ha;Joo, Su Chong
    • Journal of Internet Computing and Services
    • /
    • v.16 no.1
    • /
    • pp.47-55
    • /
    • 2015
  • Recently, the environment of a hospital information system is a trend to combine various SMART technologies. Accordingly, various smart devices, such as a smart phone, Tablet PC is utilized in the medical information system. Also, these environments consist of various applications executing on heterogeneous sensors, devices, systems and networks. In these hospital information system environment, applying a security service by traditional access control method cause a problems. Most of the existing security system uses the access control list structure. It is only permitted access defined by an access control matrix such as client name, service object method name. The major problem with the static approach cannot quickly adapt to changed situations. Hence, we needs to new security mechanisms which provides more flexible and can be easily adapted to various environments with very different security requirements. In addition, for addressing the changing of service medical treatment of the patient, the researching is needed. In this paper, we suggest a dynamic approach to medical information systems in smart mobile environments. We focus on how to access medical information systems according to dynamic access control methods based on the existence of the hospital's information system environments. The physical environments consist of a mobile x-ray imaging devices, dedicated mobile/general smart devices, PACS, EMR server and authorization server. The software environment was developed based on the .Net Framework for synchronization and monitoring services based on mobile X-ray imaging equipment Windows7 OS. And dedicated a smart device application, we implemented a dynamic access services through JSP and Java SDK is based on the Android OS. PACS and mobile X-ray image devices in hospital, medical information between the dedicated smart devices are based on the DICOM medical image standard information. In addition, EMR information is based on H7. In order to providing dynamic access control service, we classify the context of the patients according to conditions of bio-information such as oxygen saturation, heart rate, BP and body temperature etc. It shows event trace diagrams which divided into two parts like general situation, emergency situation. And, we designed the dynamic approach of the medical care information by authentication method. The authentication Information are contained ID/PWD, the roles, position and working hours, emergency certification codes for emergency patients. General situations of dynamic access control method may have access to medical information by the value of the authentication information. In the case of an emergency, was to have access to medical information by an emergency code, without the authentication information. And, we constructed the medical information integration database scheme that is consist medical information, patient, medical staff and medical image information according to medical information standards.y Finally, we show the usefulness of the dynamic access application service based on the smart devices for execution results of the proposed system according to patient contexts such as general and emergency situation. Especially, the proposed systems are providing effective medical information services with smart devices in emergency situation by dynamic access control methods. As results, we expect the proposed systems to be useful for u-hospital information systems and services.

Breathing Reserve Index at Anaerobic Threshold of Cardiopulmonary Exercise Test in Chronic Obstructive Pulmonary Disease (만성폐쇄성 폐질환의 운동부하 심폐기능검사에서 무산소역치 예비호흡지수의 의의)

  • Lee, Byoung-Hoon;Kang, Soon-Bock;Park, Sung-Jin;Jee, Hyun-Suk;Choi, Jae-Chol;Park, Yong-Bum;Ahn, Chang-Hyuk;Kim, Jae-Yeol;Park, In-Won;Choi, Byung-Whui;Hue, Sung-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.6
    • /
    • pp.795-802
    • /
    • 1999
  • Objective : Cardiopulmonary exercise test is a useful tool to evaluate the operative risk and to plan exercise treatment for the patients with chronic obstructive pulmonary disease(COPD). In cardiopulmonary exercise test, most of the measured parameters are recorded at the time of peak exercise, which are hard to attain in COPD patients. So we evaluated the usefulness of the parameter, breathing reserve index(BRI=minute ventilation [$V_E$]/maximal voluntary ventilation[MVV]) at the time of anaerobic threshold($BRI_{AT}$) for the differentiation of COPD patients with normal controls. Methods : Thirty-six COPD patients and forty-two healthy subjects underwent progressive, incremental exercise test with bicycle ergometer upto possible maximal exercise. All the parameters was measured by breath by breath method. Results : The maximal oxygen uptake in COPD patients (mean$\pm$SE) was $1061.2{\pm}65.6ml/min$ which was significantly lower than $2137.6{\pm}91.4ml/min$ of normal subjects(p<0.01). Percent predicted maximal oxygen uptake was 54.3% in COPD patients and 86.0% in normal subjects(p<0.01). Maximal exercise(respiratory quotient; $VCO_2/VO_2{\geq}1.09$) was accomplished in 7 of 36 COPD patients(19.4%) and in 18 of 42 normal subjects(42.9%). The $BRI_{AT}$ of COPD patients was higher($0.50{\pm}0.03$) than that of control subject($028{\pm}0.02$, p<0.01), reflecting early hyperventilation in COPD patient during exercise. The correlation between $BRI_{AT}$ and BRI at maximal exercise in COPD patients was good(r=0.9687, p<0.01). Conclusion : The $BRI_{AT}$ could be a useful parameter for the differentiation of COPD patients with normal controls in the submaximal cardiopulmonary exercise test.

  • PDF

USABILITY EVALUATION OF PLANNING MRI ACQUISITION WHEN CT/MRI FUSION OF COMPUTERIZED TREATMENT PLAN (전산화 치료계획의 CT/MRI 영상 융합 시 PLANNING MRI영상 획득의 유용성 평가)

  • Park, Do-Geun;Choe, Byeong-Gi;Kim, Jin-Man;Lee, Dong-Hun;Song, Gi-Won;Park, Yeong-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.127-135
    • /
    • 2014
  • Purpose : By taking advantage of each imaging modality, the use of fused CT/MRI image has increased in prostate cancer radiation therapy. However, fusion uncertainty may cause partial target miss or normal organ overdose. In order to complement such limitation, our hospital acquired MRI image (Planning MRI) by setting up patients with the same fixing tool and posture as CT simulation. This study aims to evaluate the usefulness of the Planning MRI through comparing and analyzing the diagnostic MRI image and Planning MRI image. Materials and Methods : This study targeted 10 patients who had been diagnosed with prostate cancer and prescribed nonhormone and definitive RT 70 Gy/28 fx from August 2011 to July 2013. Each patient had both CT and MRI simulations. The MRI images were acquired within one half hour after the CT simulation. The acquired CT/MRI images were fused primarily based on bony structure matching. This study measured the volume of prostate in the images of Planning MRI and diagnostic MRI. The diameters at the craniocaudal, anteroposterior and left-to-right directions from the center of prostate were measured in order to compare changes in the shape of prostate. Results : As a result of comparing the volume of prostate in the images of Planning MRI and diagnostic MRI, they were found to be $25.01cm^3$(range $15.84-34.75cm^3$) and $25.05cm^3$(range $15.28-35.88cm^3$) on average respectively. The diagnostic MRI had an increase of 0.12 % as compared with the Planning MRI. On the planning MRI, there was an increase in the volume by $7.46cm^3$(29 %) at the transition zone directions, and there was a decrease in the volume by $8.52cm^3$(34 %) in the peripheral zone direction. As a result of measuring the diameters at the craniocaudal, anteroposterior and left-to-right directions in the prostate, the Planning MRI was found to have on average 3.82cm, 2.38cm and 4.59cm respectively and the diagnostic MRI was found to have on average 3.37cm, 2.76cm and 4.51cm respectively. All three prostate diameters changed and the change was significant in the Planning MRI. On average, the anteroposterior prostate diameter decrease by 0.38cm(13 %). The mean right-to-left and craniocaudal diameter increased by 0.08cm(1.6 %) and 0.45cm(13 %), respectively. Conclusion : Based on the results of this study, it was found that the total volumes of prostate in the Planning MRI and the diagnostic MRI were not significantly different. However, there was a change in the shape and partial volume of prostate due to the insertion of prostate balloon tube to the rectum. Thus, if the Planning MRI images were used when conducting the fusion of CT/MRI images, it would be possible to include the target in the CTV without a loss as much as the increased volume in the transition zone. Also, it would be possible to reduce the radiation dose delivered to the rectum through separating more clearly the reduction of peripheral zone volume. Therefore, the author of this study believes that acquisition of Planning MRI image should be made to ensure target delineation and localization accuracy.

Usefulness of Gated RapidArc Radiation Therapy Patient evaluation and applied with the Amplitude mode (호흡 동조 체적 세기조절 회전 방사선치료의 유용성 평가와 진폭모드를 이용한 환자적용)

  • Kim, Sung Ki;Lim, Hhyun Sil;Kim, Wan Sun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.29-35
    • /
    • 2014
  • Purpose : This study has already started commercial Gated RapidArc automation equipment which was not previously in the Gated radiation therapy can be performed simultaneously with the VMAT Gated RapidArc radiation therapy to the accuracy of the analysis to evaluate the usability, Amplitude mode applied to the patient. Materials and Methods : The analysis of the distribution of radiation dose equivalent quality solid water phantom and GafChromic film was used Film QA film analysis program using the Gamma factor (3%, 3 mm). Three-dimensional dose distribution in order to check the accuracy of Matrixx dosimetry equipment and Compass was used for dose analysis program. Periodic breathing synchronized with solid phantom signals Phantom 4D Phantom and Varian RPM was created by breathing synchronized system, free breathing and breath holding at each of the dose distribution was analyzed. In order to apply to four patients from February 2013 to August 2013 with liver cancer targets enough to get a picture of 4DCT respiratory cycle and then patients are pratice to meet patient's breathing cycle phase mode using the patient eye goggles to see the pattern of the respiratory cycle to be able to follow exactly in a while 4DCT images were acquired. Gated RapidArc treatment Amplitude mode in order to create the breathing cycle breathing performed three times, and then at intervals of 40% to 60% 5-6 seconds and breathing exercises that can not stand (Fig. 5), 40% While they are treated 60% in the interval Beam On hold your breath when you press the button in a way that was treated with semi-automatic. Results : Non-respiratory and respiratory rotational intensity modulated radiation therapy technique absolute calculation dose of using computerized treatment plan were shown a difference of less than 1%, the difference between treatment technique was also less than 1%. Gamma (3%, 3 mm) and showed 99% agreement, each organ-specific dose difference were generally greater than 95% agreement. The rotational intensity modulated radiation therapy, respiratory synchronized to the respiratory cycle created Amplitude mode and the actual patient's breathing cycle could be seen that a good agreement. Conclusion : When you are treated Non-respiratory and respiratory method between volumetric intensity modulated radiation therapy rotation of the absolute dose and dose distribution showed a very good agreement. This breathing technique tuning volumetric intensity modulated radiation therapy using a rotary moving along the thoracic or abdominal breathing can be applied to the treatment of tumors is considered. The actual treatment of patients through the goggles of the respiratory cycle to create Amplitude mode Gated RapidArc treatment equipment that does not automatically apply to the results about 5-6 seconds stopped breathing in breathing synchronized rotary volumetric intensity modulated radiation therapy facilitate could see complement.

Lung Clearance of Inhaled $^{99m}Tc$-DTPA by Urine Excretion Ratio (소변내 방사능배설량비를 이용한 $^{99m}Tc$-DTPA 폐청소율에 관한 연구)

  • Suh, G.Y.;Park, K.Y.;Jung, M.P.;Yoo, C.G.;Lee, D.S.;Kim, Y.W.;Han, S.K.;Jung, J.K.;Lee, M.C.;Shim, Y.S.;Kim, K.Y.;Han, Y.C.
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.4
    • /
    • pp.357-366
    • /
    • 1993
  • Background: Lung clearance of inhaled $^{99m}Tc$-DTPA reflects alveolar epithelial permeability and it had been reported as more sensitive than conventional pulmonary function tests in detecting lung epithelial damage. However, measuring lung clearance of inhaled $^{99m}Tc$-DTPA by gamma camera may not always reflect alveolar epithelial permeability exactly because it is influenced by mucociliary clearance depending on the site of particle deposition. Moreover, this method takes much time and patient's effort because he has to sit or lie still in front of the camera for a prolonged period. Most of the absorbed DTPA is excreted in urine within 24 hours and the amount of excreted DTPA in urine during the first few hours after inhalation is influenced by absorption rate which is correlated with the alveolar-epithelial permeability suggesting that the urinary excretion, especially in first few hours, may be an alternate index for lung clearance. The purpose of this study was to evaluate the usefulness of ratio of excreted $^{99m}Tc$-DTPA in 2 hour and 24 hour urine as an index of alveolar-epithelial damage. Methods: Pulmonary function tests including diffusing capacity and lung clearance of $^{99m}Tc$-DTPA measured by gama camera ($T_{1/2}$) and 2hr/24hr urine excretion ratio (Ratio) of inhaled $^{99m}Tc$-DTPA in 8 normal subjects and 14 patients with diffuse interstitial lung disease were compared. Results: 1) In the normal control, there was significant negative correlation between the $T_{1/2}$ and the Ratio (r=-0.77, p<0.05). In patients with diffuse interstitial lung disease, there also was significant negative correlation between $T_{1/2}$ and Ratio(r=-0.63, p<0.05). 2) In diffuse interstitial lung disease patients, the $T_{1/2}$ was $38.65{\pm}11.63$ min which was significantly lower than that of normal control, $55.53{\pm}11.15$ min and the Ratio was $52.15{\pm}10.07%$ also signifantly higher than that of the normal control, $40.43{\pm}5.53%$ (p<0.05). 3) There was no significant correlations between $T_{1/2}$ or Ratio and diffusing capactiy of lung in both patients and controls (p>0.05). Conclusion: These results suggests that 2hr/24hr urine excretion ratio of inhaled $^{99m}Tc$-DTPA is a useful simple bedside test in assessing alveolar epithelial permeability and that it may be used as an additive follow-up test in patients with diffuse interstitial lung disease complementing conventional pulmonary function tests.

  • PDF

Application of Support Vector Regression for Improving the Performance of the Emotion Prediction Model (감정예측모형의 성과개선을 위한 Support Vector Regression 응용)

  • Kim, Seongjin;Ryoo, Eunchung;Jung, Min Kyu;Kim, Jae Kyeong;Ahn, Hyunchul
    • Journal of Intelligence and Information Systems
    • /
    • v.18 no.3
    • /
    • pp.185-202
    • /
    • 2012
  • .Since the value of information has been realized in the information society, the usage and collection of information has become important. A facial expression that contains thousands of information as an artistic painting can be described in thousands of words. Followed by the idea, there has recently been a number of attempts to provide customers and companies with an intelligent service, which enables the perception of human emotions through one's facial expressions. For example, MIT Media Lab, the leading organization in this research area, has developed the human emotion prediction model, and has applied their studies to the commercial business. In the academic area, a number of the conventional methods such as Multiple Regression Analysis (MRA) or Artificial Neural Networks (ANN) have been applied to predict human emotion in prior studies. However, MRA is generally criticized because of its low prediction accuracy. This is inevitable since MRA can only explain the linear relationship between the dependent variables and the independent variable. To mitigate the limitations of MRA, some studies like Jung and Kim (2012) have used ANN as the alternative, and they reported that ANN generated more accurate prediction than the statistical methods like MRA. However, it has also been criticized due to over fitting and the difficulty of the network design (e.g. setting the number of the layers and the number of the nodes in the hidden layers). Under this background, we propose a novel model using Support Vector Regression (SVR) in order to increase the prediction accuracy. SVR is an extensive version of Support Vector Machine (SVM) designated to solve the regression problems. The model produced by SVR only depends on a subset of the training data, because the cost function for building the model ignores any training data that is close (within a threshold ${\varepsilon}$) to the model prediction. Using SVR, we tried to build a model that can measure the level of arousal and valence from the facial features. To validate the usefulness of the proposed model, we collected the data of facial reactions when providing appropriate visual stimulating contents, and extracted the features from the data. Next, the steps of the preprocessing were taken to choose statistically significant variables. In total, 297 cases were used for the experiment. As the comparative models, we also applied MRA and ANN to the same data set. For SVR, we adopted '${\varepsilon}$-insensitive loss function', and 'grid search' technique to find the optimal values of the parameters like C, d, ${\sigma}^2$, and ${\varepsilon}$. In the case of ANN, we adopted a standard three-layer backpropagation network, which has a single hidden layer. The learning rate and momentum rate of ANN were set to 10%, and we used sigmoid function as the transfer function of hidden and output nodes. We performed the experiments repeatedly by varying the number of nodes in the hidden layer to n/2, n, 3n/2, and 2n, where n is the number of the input variables. The stopping condition for ANN was set to 50,000 learning events. And, we used MAE (Mean Absolute Error) as the measure for performance comparison. From the experiment, we found that SVR achieved the highest prediction accuracy for the hold-out data set compared to MRA and ANN. Regardless of the target variables (the level of arousal, or the level of positive / negative valence), SVR showed the best performance for the hold-out data set. ANN also outperformed MRA, however, it showed the considerably lower prediction accuracy than SVR for both target variables. The findings of our research are expected to be useful to the researchers or practitioners who are willing to build the models for recognizing human emotions.

A Study on the Differences of Information Diffusion Based on the Type of Media and Information (매체와 정보유형에 따른 정보확산 차이에 대한 연구)

  • Lee, Sang-Gun;Kim, Jin-Hwa;Baek, Heon;Lee, Eui-Bang
    • Journal of Intelligence and Information Systems
    • /
    • v.19 no.4
    • /
    • pp.133-146
    • /
    • 2013
  • While the use of internet is routine nowadays, users receive and share information through a variety of media. Through the use of internet, information delivery media is diversifying from traditional media of one-way communication, such as newspaper, TV, and radio, into media of two-way communication. In contrast of traditional media, blogs enable individuals to directly upload and share news, which can be considered to have a differential speed of information diffusion than news media that convey information unilaterally. Therefore this Study focused on the difference between online news and social media blogs. Moreover, there are variations in the speed of information diffusion because that information closely related to one person boosts communications between individuals. We believe that users' standard of evaluation would change based on the types of information. As well, the speed of information diffusion would change based on the level of proximity. Therefore, the purpose of this study is to examine the differences in information diffusion based on the types of media. And then information is segmentalized and an examination is done to see how information diffusion differentiates based on the types of information. This study used the Bass diffusion model, which has been frequently used because this model has higher explanatory power than other models by explaining diffusion of market through innovation effect and imitation effect. Also this model has been applied a lot in other information diffusion related studies. The Bass diffusion model includes an innovation effect and an imitation effect. Innovation effect measures the early-stage impact, while the imitation effect measures the impact of word of mouth at the later stage. According to Mahajan et al. (2000), Innovation effect is emphasized by usefulness and ease-of-use, as well Imitation effect is emphasized by subjective norm and word-of-mouth. Also, according to Lee et al. (2011), Innovation effect is emphasized by mass communication. According to Moore and Benbasat (1996), Innovation effect is emphasized by relative advantage. Because Imitation effect is adopted by within-group influences and Innovation effects is adopted by product's or service's innovation. Therefore, ours study compared online news and social media blogs to examine the differences between media. We also choose different types of information including entertainment related information "Psy Gentelman", Current affair news "Earthquake in Sichuan, China", and product related information "Galaxy S4" in order to examine the variations on information diffusion. We considered that users' information proximity alters based on the types of information. Hence, we chose the three types of information mentioned above, which have different level of proximity from users' standpoint, in order to examine the flow of information diffusion. The first conclusion of this study is that different media has similar effect on information diffusion, even the types of media of information provider are different. Information diffusion has only been distinguished by a disparity between proximity of information. Second, information diffusions differ based on types of information. From the standpoint of users, product and entertainment related information has high imitation effect because of word of mouth. On the other hand, imitation effect dominates innovation effect on Current affair news. From the results of this study, the flow changes of information diffusion is examined and be applied to practical use. This study has some limitations, and those limitations would be able to provide opportunities and suggestions for future research. Presenting the difference of Information diffusion according to media and proximity has difficulties for generalization of theory due to small sample size. Therefore, if further studies adopt to a request for an increase of sample size and media diversity, difference of the information diffusion according to media type and information proximity could be understood more detailed.

The Usefulness of Pressure-regulated Volume Control(PRVC) Mode in Mechanically Ventilated Patients with Unstable Respiratory Mechanics (기계 호흡 중 불안정한 호흡역학을 보인 환자에서 압력조절용적조정양식(Pressure-regulated Volume Control Mode)의 효용)

  • Sohn, Jang-Won;Koh, Youn-Suck;Lim, Chae-Man;Shim, Tae-Sun;Lee, Jong-Deog;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.6
    • /
    • pp.1318-1325
    • /
    • 1997
  • Background : Since the late 1960s, mechanical ventilation has been accomplished primarily using volume controlled ventilation(VCV). While VCV allows a set tidal volume to be guaranteed, VCV could bring about excessive airway pressures that may be lead to barotrauma in the patients with acute lung injury. With the increment of knowledge related to ventilator-induced lung injury, pressure controlled ventilation(PCV) has been frequently applied to these patients. But, PCV has a disadvantage of variable tidal volume delivery as pulmonary impedance changes. Since the concept of combining the positive attributes of VCV and PCV(dual control ventilation, DCV) was described firstly in 1992, a few DCV modes were introduced. Pressure-regulated volume control(PRVC) mode, a kind of DCV, is pressure-limited, time-cycled ventilation that uses tidal volume as a feedback control for continuously adjusting the pressure limit However, no clinical studies were published on the efficacy of PRVC until now. 'This investigation studied the efficacy of PRVC in the patients with unstable respiratory mechanics. Methods : The subjects were 8 mechanically ventilated patients(M : F=6 : 2, $56{\pm}26$ years) who showed unstable respiratory mechanics, which was defined by the coefficients of variation of peak inspiratory pressure for 15 minutes greater than 10% under VCV, or the coefficients of variation of tidal volume greater than 10% under PCV. The study was consisited of 3 modes application with VCV, PCV and PRVC for 15 minutes by random order. To obtain same tidal volume, inspiratory pressure setting was adjusted in PCV. Respiratory parameters were measured by pulmonary monitor(CP-100 pulmonary monitor, Bicore, Irvine, CA, USA). Results : 1) Mean tidal volumes($V_T$) in each mode were not different(VCV, $431{\pm}102ml$ ; PCV, $417{\pm}99ml$ ; PRVC, $414{\pm}97ml$) 2) The coefficient of variation(CV) of $V_T$ were $5.2{\pm}3.9%$ in VCV, $15.2{\pm}7.5%$ in PCV and $19.3{\pm}10.0%$ in PRVC. The CV of $V_T$ in PCV and PRVC were significantly greater than that in VCV(p<0.01). 3) Mean peak inspiratory pressure(PIP) in VCV($31.0{\pm}6.9cm$ $H_2O$) was higher than PIP in PCV($26.0{\pm}6.5cm$ $H_2O$) or PRVC($27.0{\pm}6.4cm$ $H_2O$)(p<0.05). 4) The CV of PIP were $13.9{\pm}3.7%$ in VCV, $4.9{\pm}2.6%$ in PVC and $12.2{\pm}7.0%$ in PRVC. The CV of PIP in VCV and PRVC were greater than that in PCV(p<0.01). Conclusions : Because of wide fluctuations of VT and PIP, PRVC mode did not seem to have advantages compared to VCV or PCV in the patients with unstable respiratory mechanics.

  • PDF

Analysis of Specificity for Tumor Marker CYFRA 21-1 in Patients with Pulmonary Tuberculosis (폐결핵 환자에서 종양표지자 CYFRA 21-1의 특이도 분석)

  • Ha, Hyun-Cheol;Lee, Jae-Sung;Song, Sun-Dae;Kim, Cheol-Min;Lee, Min-Gi;Kim, In-Joo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.2
    • /
    • pp.290-300
    • /
    • 1998
  • Background: CYFRA 21-1 is a tumor marker which measures a fragment of cytokeratin 19 expressed by epithelial cells in bronchus. It is known that cytokeratin 19 is abundant in squamous epithelial cell cancer of the lung. However, if the incidence of elevated serum CYFRA 21-1 level in patients with benign lung diseases or pulmonary tuberculosis with severe parenchymal damage is high the specificity of CYFRA 21-1 could be decreased. The purpose of this study is to investigate the changes of serum CYFRA 21-1 according to the degree of parenchymal damage and the usefulness of CYFRA 21-1 for diagnosing possibly combined lung cancer in patients with pulmonary tuberculosis. Method: We studied the changes of serum CYFRA 21-1 according to the sputum AFB stain, radiologic manifestation and history of treatment in 81 patients with pulmonary tuberculosis, and 20 healthy persons, 25 patients with lung cancer, as a control group. CYFRA 21-1 concentration in serum was quantified by the immunoradiometry assay(Centocor$^{(R)}$). Result: The results were as follow; Serum CYFRA 21-1 level was significantly lower in patients with pulmonary tuberculosis($1.54{\pm}1.19ng/mL$, p<0.01) as compared to patients with lung cancer($12.25{\pm}15.97ng/mL$), and was slightly higher than the level in heathy persons($0.90{\pm}0.49ng/mL$) but there was no significant difference. Serum CYFRA 21-1 level was below the cut-off value of 3.3ng/mL in 95 percent of patients with pulmonary tuberculosis but it was above the cut-off value in 64 percent of patients with lung cancer. Serum CYFRA 21-1 level was significantly higher in the initial treatment group($1.91{\pm}1.55ng/mL$, p<0.05) as compared to the treatment. failure group ($0.92{\pm}0.30ng/mL$). According to the sputum AFB smear, serum CYFRA 21-1 level in patients with negative result was slightly higher than the level in patients with positive result but there was no significant difference. According to the radiologic manifestation, serum CYFRA 21-1 level was significantly higher in patients with infiltrative lesion ($2.15{\pm}1.63ng/mL$, p<0.01) as compared to patients with destructive lesion ($l.04{\pm}0.54ng/mL$). As the size of cavity or destructive lesion was larger, the level was significantly lower(p<0.05). Conclusion: As serum CYFRA 21-1 level was significantly higher in the initial treatment group and patients with infiltrative lesion, it suppose to be closely related with the degree of parenchymal damage of the lung of the pulmonary tuberculosis. However CYFRA 21-1 could be useful method for diagnosing lung cancer even in patients with pulmonary tuberculosis combined with lung cancer because of the fact that it was below the cutoff value of 3.3ng/mL in 95 percent of patients with pulmonary tuberculosis.

  • PDF

Usefulness of Troponin-I, Lactate, C-reactive protein as a Prognostic Markers in Critically Ill Non-cardiac Patients (비 순환기계 중환자의 예후 인자로서의 Troponin-I, Lactate, C-reactive protein의 유용성)

  • Cho, Yu Ji;Ham, Hyeon Seok;Kim, Hwi Jong;Kim, Ho Cheol;Lee, Jong Deok;Hwang, Young Sil
    • Tuberculosis and Respiratory Diseases
    • /
    • v.58 no.6
    • /
    • pp.562-569
    • /
    • 2005
  • Background : The severity scoring system is useful for predicting the outcome of critically ill patients. However, the system is quite complicated and cost-ineffective. Simple serologic markers have been proposed to predict the outcome, which include troponin-I, lactate and C-reactive protein(CRP). The aim of this study was to evaluate the prognostic values of troponin-I, lactate and CRP in critically ill non-cardiac patients. Methods : From September 2003 to June 2004, 139 patients(Age: $63.3{\pm}14.7$, M:F = 88:51), who were admitted to the MICU with non-cardiac critical illness at Gyeongsang National University Hospital, were enrolled in this study. This study evaluated the severity of the illness and the multi-organ failure score (Acute Physiologic and Chronic Health EvaluationII, Simplified Acute Physiologic ScoreII and Sequential Organ Failure Assessment) and measured the troponin-I, lactate and CRP within 24 hours after admission in the MICU. Each value in the survivors and non-survivors was compared at the 10th and 30th day after ICU admission. The mortality rate was compared at 10th and 30th day in normal and abnormal group. In addition, the correlations between each value and the severity score were assessed. Results : There were significantly higher troponin-I and CRP levels, not lactate, in the non-survivors than in the survivors at 10th day($1.018{\pm}2.58ng/ml$, $98.48{\pm}69.24mg/L$ vs. $4.208{\pm}10.23ng/ml$, $137.69{\pm}70.18mg/L$) (p<0.05). There were significantly higher troponin-I, lactate and CRP levels in the non-survivors than in the survivors on the 30th day ($0.99{\pm}2.66ng/ml$, $8.02{\pm}9.54ng/dl$, $96.87{\pm}68.83mg/L$ vs. $3.36{\pm}8.74ng/ml$, $15.42{\pm}20.57ng/dl$, $131.28{\pm}71.23mg/L$) (p<0.05). The mortality rate was significantly higher in the abnormal group of troponin-I, lactate and CRP than in the normal group of troponin-I, lactate and CRP at 10th day(28.1%, 31.6%, 18.9% vs. 11.0%, 15.8 %, 0%) and 30th day(38.6%, 47.4%, 25.8% vs. 15.9%, 21.7%, 14.3%) (p<0.05). Troponin-I and lactate were significantly correlated with the SAPS II score($r^2=0.254$, 0.365, p<0.05). Conclusion : Measuring the troponin-I, lactate and CRP levels upon admission may be useful for predicting the outcome of critically ill non-cardiac patients.