• 제목/요약/키워드: used nuclear fuel storage

검색결과 88건 처리시간 0.024초

PLUTONIUM MANAGEMENT OPTIONS: LIABILITY OR RESOURCE

  • Bairiot, Hubert
    • Nuclear Engineering and Technology
    • /
    • 제40권1호
    • /
    • pp.9-20
    • /
    • 2008
  • Since plutonium accounts for 40-50% of the power produced by uranium fuels, spent fuel contains only residual plutonium. Management of this plutonium is one of the aspects influencing the choice of a fuel cycle back-end option: reprocessing, direct disposal or wait-and-see. Different grades and qualities of plutonium exist depending from their specific generation conditions; all are valuable fissile material. Safeguard authorities watch the inventories of civil plutonium, but access to those data is restricted. Independent evaluations have led to an estimated current inventory of 220t plutonium in total (spent fuel, separated civil plutonium and military plutonium). If used as MOX fuel, it would be sufficient to feed all the PWRs and BWRs worldwide during 7 years or to deploy a FBR park corresponding to 150% of today' s installed nuclear capacity worldwide, which could then be exploited for centuries with the current stockpile of depleted and spent uranium. The energy potential of plutonium deteriorates with storage time of spent fuel and of separated plutonium, due to the decay of $^{241}Pu$, the best fissile isotope, into americium, a neutron absorber. The loss of fissile value of plutonium is more pronounced for usage in LWRs than in FBR. However, keeping the current plutonium inventory for an expected future deployment of FBRs is counterproductive. Recycling plutonium reduce the required volume for final disposal in an underground repository and the cost of final disposal. However, the benefits of utilizing an energy resource and of reducing final disposal liabilities are not the only aspects that determine the choice of a back-end policy.

국내 경수로 사용후핵연료의 금속 겸용용기 장전을 위한 최소 냉각기간 평가 (The Evaluation of Minimum Cooling Period for Loading of PWR Spent Nuclear Fuel of a Dual Purpose Metal Cask)

  • 도호석;김태만;조천형
    • 방사성폐기물학회지
    • /
    • 제14권4호
    • /
    • pp.411-422
    • /
    • 2016
  • 최근 국내 원전의 경수로 사용후핵연료 습식 저장시설의 포화시점이 다가옴에 따라 운반 및 저장용기를 이용한 건식저장시스템 개발이 활발하게 수행되고 있다. 일반적으로 사용후핵연료 운반 및 저장용기 설계를 위한 차폐해석 시 장전 가능 연료 중 가장 보수적인 연료를 설계기준연료로 선정하여 해석을 수행한다. 그러나 실제 금속 운반용기에 장전되는 사용후핵연료는 해석평가에 적용된 설계기준연료에 한정되지 않고 다양하기 때문에 초기농축도, 연소도, 최소냉각기간의 특성을 고려한 차폐평가를 통하여 장전가능 여부가 결정된다. 이에 본 연구에서는 금속 겸용용기에 장전 가능한 연료를 대상으로 국내 운반기준을 만족하는 최소냉각기간의 결정을 위한 차폐해석 방법을 기술하였다. 특히 발생량이 많은 초기농축도 3.0~4.5wt%의 사용후핵연료는 차폐해석 구간을 세분화하여 평가하여 연구결과의 활용에 효율성을 높이고자 하였다. 차폐평가를 통해 2008년까지 국내 원전에서 발생한 장전대상연료 중 약 81%의 사용후 핵연료를 금속겸용용기로 운반할 수 있는것으로 평가되었다. 본 연구결과를 통해 금속 겸용용기의 운반조건에 장전 가능한 연료의 특성을 제시함으로써 운반 시 운영절차의 개발을 위한 기술적 근거 수립에 도움이 되고자 한다.

Experimental simulation of activity release from leaking fuel rods

  • Somfai, Barbara;Hozer, Zoltan;Nagy, Imre
    • Nuclear Engineering and Technology
    • /
    • 제50권7호
    • /
    • pp.1148-1153
    • /
    • 2018
  • The Leaking Fuel Experiment test facility was designed to simulate the activity release from spent leaking fuel rods under steady state and transient conditions in the spent fuel pool. The experimental rig included an electrically heated fuel rod with different defects and a cooling system. The fission product transport was simulated by potassium-chloride. The conductivity changes of the water in the cooling system were measured to provide information about the amount of released solution. Defects of different sizes and positions were applied, together with a wide range of rod powers to simulate decay heat. The produced data can be used for predicting the activity release from leaking fuel under storage conditions and for the interpretation of fuel examination procedures.

Three-Dimensional Seismic Analysis for Spent Fuel Storage Rack

  • Lee, Gyu-Mahn;Kim, Kang-Soo;Park, Keun-Bae;Park, Jong-Kyun
    • Nuclear Engineering and Technology
    • /
    • 제30권2호
    • /
    • pp.91-98
    • /
    • 1998
  • Time history analysis is usually performed to characterize the nonlinear seismic behavior of a spent fuel storage rack(SFSR). In the past, the seismic analyses of the SFSR were performed with two-dimensional planar models, which could not account for torsional response and simultaneous multi-directional seismic input In this study, three-dimensional seismic analysis methodology is developed for the single SFSR using the ANSYS code. The 3D- Model can be used to determine the nonlinear behavior of the rack, i.e., sliding, uplifting, and impact evaluation between the fuel assembly and rack, and rack and the pool wall, This paper also reviews the 3-D modeling of the SFSR and the adequacy of the ANSYS for the seismic analysis. AS a result of the adquacy study, the method of ANSYS transient analysis with acceleration time history is suitable for the seismic analysis of highly nonlinear structure such as an SFSR but it isn't appropriate to use displacement time history of seismic input.

  • PDF

Design Improvement for the Cooling System of the Interim Spent Fuel Storage Facility Using a PSA Method

  • Ko, Won-Il;Park, Jong-Won;Park, Seong-Won;Lee, Jae-Sol;Park, Hyun-Soo
    • Nuclear Engineering and Technology
    • /
    • 제28권5호
    • /
    • pp.440-451
    • /
    • 1996
  • With emphasis on safety, this study addresses for better design condition for the cooling system in a wet-type interim spent fuel storage facility, using a probabilistic safety assessment method. To incorporate the design renovation into the design phase, a simple approach is proposed. By taking the cooling system of a reference design, a fault tree analysis was performed to identify the weak point of the considered system, and then basic factors for design renovation were defined. A total of 21 design alternatives were selected through the combination of the basic factors. Finally, the optimum design alternative for the cooling system is derived by means of the cost and effect analysis based on the estimated cost, system reliability and assumed probabilistic safety criteria. With the assumption that the failure frequency of at-reactor spent fuel cooling system compiles with probabilistic safety criteria for the interim spent fuel cooling system, it was shown that the optimum alternative should have l00% cooling loop redundancy with one pump per cooling loop and a cleanup system installed separately from the main loop. Furthermore, it also should be classified into safety system. The result of this study can be used as a useful basis to identify factors of safety concern and to establish design requirements in the future. The method also can be applied for other nuclear facilities.

  • PDF

사용후핵연료 건식저장을 위한 기체강제순환 건조장치 예비설계 (Preliminary Design of the Forced Gas Drying System for Spent Nuclear Fuel Dry Storage)

  • 채경선;신경욱;박병목;한재현;이건희;박재석
    • 방사성폐기물학회지
    • /
    • 제15권4호
    • /
    • pp.403-409
    • /
    • 2017
  • 원자력발전소내 습식저장중인 사용후핵연료의 건식저장을 위해서는 캐니스터 내부에 사용후핵연료를 옮겨 담은 이후, 건식저장 캐니스터 내장품이나 사용후핵연료 다발의 부식방지 및 피복관의 열화방지를 위해 모든 수분은 제거해야 한다. 캐니스터 내부의 수분을 제거하는데 사용할 수 있는 기체강제순환 건조시스템 개발을 위한 연구개발이 진행중이다. 본 연구에서는 기체강제순환 건조시스템 설계, 제작을 위한 예비설계를 수행하였다. 예비설계에는 캐니스터 내부 잔존수분 제거를 위한 건조사례조사, 건조관련 규격이나 표준, 건조합격기준, 건조장치구성, 현장요구분석, 습식저장중인 사용후핵연료 특성을 포함하였다. 예비설계를 통하여 기체강제순환 건조시스템의 설계 개념도와 P&ID를 도출하였고, 이를 활용하여 건조시스템 제작을 위한 상세설계를 수행할 것이다.

원전부지내 사용후핵연료 건식저장기술 분석 (Technology for AR Dry Storage of Spent Fuel)

  • 이흥영;윤석중;이익환;서기석
    • Journal of Radiation Protection and Research
    • /
    • 제21권4호
    • /
    • pp.313-327
    • /
    • 1996
  • 원전부지내(AR) 사용후핵연료 건식저장방식으로 횡형콘크리트 모듈방식, 금속 저장용기 방식, 콘크리트 저장용기 방식, 수송저장 겸용용기 방식 및 다목적용기 방식 등이 있다. 이중다목적용기 방식을 제외한 다른 방식들은 각각 운영인허가를 받아 이미 세계 각 국에서 사용후핵연료 AR 건식저장에 사용되고 있으며 다목적용기 방식도 최근 개발을 활발히 진행하고 있는 상태이다. AR 건식저장 시설을 운영하고 있거나 추진중인 나라는 미국, 일본, 독일, 캐나다, 스페인, 체코, 스위스 등으로 AR 건식저장을 거쳐 중간저장이나 재처리시설로 수송하는 방식을 채택하고 있다. 우리나라의 경우 월성에서 콘크리트 Silo 건식저장을 이미 사용하고 있으며 일부 다른 원자로도 사용후핵연료 저장능력이 한계에 도달하고 있는 현실을 감안할 때 AR 임시 저장은 불가피한 것으로 여겨진다. 본 보고서에서는 고리를 비롯한 국내원전에 적용 가능한 외국의 AR 저장 시스템 각각에 대하여 설계특성, 설계요건, 기술기준 및 현황 등을 논의하였다. 대부분의 경우 저장용기 인허가 기간은 20년으로 제한하고 있으며 전 수명기간동안 재질의 건전성, 밀봉유지 등이 중요하게 요구되고 있다.

  • PDF

Application of Logistic Simulation for Transport of SFs From Kori Site to an Assumed Interim Storage Facility

  • Kim, Young-Min;Kim, Chang-Lak
    • 방사성폐기물학회지
    • /
    • 제19권1호
    • /
    • pp.61-74
    • /
    • 2021
  • A paradigm shift in the government's energy policy was reflected in its declaration of early closure of old nuclear plants as well as cancellation of plans for the construction of new plants. To this end, unit 1 of Kori Nuclear Power Plant was permanently shut down and is set for decommission. Based on these changes, the off-site transport of spent fuels from nuclear power plants has become a critical issue. The purpose of this study is to develop an optimized method for transportation of spent fuels from Kori Nuclear Power Plant's units 1, 2, 3, and 4 to an assumed interim storage facility by simulating the scenarios using the Flexsim software, which is widely used in logistics and manufacturing applications. The results of the simulation suggest that the optimized transport methods may contribute to the development of delivery schedule of spent fuels in the near future. Furthermore, these methods can be applied to decommissioning plan of nuclear power plants.

연소도이득효과(BUC) 적용 사용후핵연료 운반용기의 임계 불확실도 평가 (Criticality Uncertainty Analysis of Spent Fuel Transport Cask applying Burnup Credit)

  • 이강욱;박제호;김도형;김태만;윤정현
    • 방사성폐기물학회지
    • /
    • 제9권3호
    • /
    • pp.191-198
    • /
    • 2011
  • 국내 외 수많은 수송 건식저장 시스템의 임계해석은 사용후핵연료내에 초우라늄물질(transuranic) 및 핵분열생성물(fission products) 계산의 불확실성을 이유로, 신연료로 가정된 가상연료를 적용하여 평가해왔다. 그러나 과도한 임계 여유도에 따른 경제적 손실이 크기 때문에 최근 들어 연소도이득(Burnup Credit, BUC)이 반영된 수송 건식저장 시스템의 설계 및 상용화가 추진되고 있다. 이러한 BUC 기술은 기존 임계해석 시요구되는 상수화된 불확실도와 달리 초기 농축도와 연소도 구간에 따라 상이한 불확실도를 갖게 된다. 이에 본 연구에서는 '국내 원전의 제한사항이 반영된 26다발 SNF 장전 BUC 적용 용기'(이하 BK 26 Cask)를 대상으로 관련 기술표준 및 설계요건에서 요구되는 불확실도를 평가하여 농축도 및 연소도의 함수로 계산하였다. 본 연구결과는 추후 BK 26 Cask 국내 사용후핵연료의 장전 수용률 분석의 기반자료로 활용된다.

정상운반조건 해석을 위한 사용후핵연료집합체 유한요소모델 최적화 (Optimization of Spent Nuclear Fuel Assembly Finite Element Model for Normal Transportation Condition Analysis)

  • 김민식;박민정;장윤석
    • 한국압력기기공학회 논문집
    • /
    • 제19권2호
    • /
    • pp.163-170
    • /
    • 2023
  • Since spent nuclear fuel assemblies (SFA) are transported to interim storage or final disposal facility after cooling the decay heat, finite element analysis (FEA) with simplification is widely used to show their integrity against cladding failure to cause dispersal of radioactive material. However, there is a lack of research addressing the comprehensive impact of shape and element simplification on analysis results. In this study, for the optimization of a typical pressurized water reactor SFA, different types of finite element models were generated by changing number of fuel rods, fuel rod element type and assembly length. A series of FEA in use of these different models were conducted under a shock load data obtained from surrogate fuel assembly transportation test. Effects of number of fuel rods, element type and length of assembly were also analyzed, which shows that the element type of fuel rod mainly affected on cladding strain. Finally, an optimal finite element model was determined for other practical application in the future.