• 제목/요약/키워드: urine collection

검색결과 132건 처리시간 0.021초

여성에서 소변채집방법에 따른 소변검체의 오염율 비교 (Comparison of the Bacterial Contamination Rates according to the Urine Collection Methods in Women)

  • 정인숙;양만길;오향순
    • 기본간호학회지
    • /
    • 제6권3호
    • /
    • pp.359-368
    • /
    • 1999
  • Background : The purpose of this study was to determine whether cleansing the perineum and urethral meatus and using midstream urine affect the rate of bacterial contamination of urine specimens, and to determine the optimum urine collection method. We studied 41 asymptomatic healthy nursing school students. Women who were menstruating were not excluded from this study. Method : The first and midstream urine samples were collected during consecutive urinationsby each woman. The first sample was not a clean-catch specimen, and the second one was a clean-catch specimen. Both specimens were studied by urinalysis and bacterial culture with standard methods. Results : 41 women met the study criteria and 39 successfully completed the study. None of the urine cultures were positive. 68.3% of the non clean-catch first urine cultures, 53.7% of the non clean-catch midstream cultures, 33.3% of the first clean-catch urine culteres and 30.8% of the midstream clean-catch urine were found to be contaminated. There was a significant difference in the bacterial contamination rates between the first and midstream urine, and the clean-catch and non clean-catch urine(p=0.035, p =0.001 respectively). On urinalysis, 7.3% of the non clean-catch first urine, 7.3% of the non clean-catch midstream urine, 2.6% of the clean-catch first urine and 2.6% of clean-catch midstream urine were found to be above grade 2. Conclusions : According to our results, the bacterial contamination rate was the lowest in midstream and clean catch urine specimens. Threrfore it is recommended that the midstream clean-catch technique is the standard practice for collecting urine specimens for bacterial culture in women.

  • PDF

Fasting Urine을 사용한 Microalbumin의 참고치에 관한 연구 (Reference Ranges of Microalbumin Using Fasting Urine)

  • 김지영;진광호;배애영;김예나;서상원;이나리;전하영;신숙희
    • 대한임상검사과학회지
    • /
    • 제38권3호
    • /
    • pp.208-211
    • /
    • 2006
  • Microalbuminuria is most frequently caused by kidney damage from diabetes. Moreover, many other conditions can lead to kidney damage, such as high blood pressure, heart failure, cirrhosis, or systemic lupus erythematosus (SLE). The measurement of the microalbumin in urine may be useful for the early diagnosis or as a predictor of nephropathy in diabetes. The most common method for getting a quantitative measurement of urinary protein relies on a 24-hour urine collection. The result of this method is accurate. But 24hr urine collection is difficult to obtain and variations in volume are frequent. Also the patients complain about urine collection. We tried to measure reference values for microalbumin using fasting urine and compare them with the albumin/creatinine ratio using 24hr urine. The concentrations of microalbumin in fasting urine and 24hr urine were $7.1{\pm}3.8mg/L$, $5.7{\pm}2.9mg/L$ (r=0.61, p=0.27), respectively. The albumin/creatinine ratios using fasting urine and 24hr urine were $8.7{\pm}4.2{\mu}g/mg$, $8.7{\pm}4.0{\mu}g/mg$ (r=0.76, p=0.88), respectively. This study indicated that the measurement of microalbumin in fasting urine was an easy and simple method for early diagnosis or to predict nephropathy in diabetes. Thus, setting up the reference value using fasting urine may be useful in the screening test for the diabetic nephropathy patients instead of using the 24hr albumin excretion rate (AER).

  • PDF

요속검사시 배뇨상황에 무관한 신호대잡음비 개선 기법 (Enhancement of signal-to-noise ratio for uroflowmetric test regardless of urination situation)

  • 김경아;최성수;이상봉;김경옥;박경순;신은영;김원재;차은종
    • 센서학회지
    • /
    • 제18권6호
    • /
    • pp.423-431
    • /
    • 2009
  • Standard uroflowmetry measures the urine weight using single load cell to evaluate the urinary flow rate. Impact noise should be introduced due to gravity when the urine stream falls down into the container upon the load cell. The present study placed three load cells on the three vertices of a regular triangle and the three signals were ensemble averaged to enhance the signal-to-noise ratio(SNR) regardless of how the urination was made. Simulated urination experiment was performed with three different urine collection methods. In all three methods, SNR of the averaged signal was much higher than each load cell signals. With no urine collection device, the present signal averaging technique resulted in SNR values higher by 10~15 dB than when dual funnels or upper funnel were used to guide the urine stream. Therefore, it was demonstrated that the three point measurement followed by with ensemble averaging could enable accurate uroflowmetric test without any specially made urine collection devices.

유소아에서 일회용 기저귀를 이용한 소변 채취 방법 (Urine Collection from Disposable Diapers in Infants and Young Children)

  • 김미정;김지혜;임형은;강희;은백린;유기환;홍영숙;이주원;권정아
    • Childhood Kidney Diseases
    • /
    • 제9권2호
    • /
    • pp.128-136
    • /
    • 2005
  • 목 적 : 기저귀를 사용하는 어린 유소아들의 소변검체를 얻기 위해 멸균 비닐백을 이용하고 있으나 현실적인 불편함 때문에 보다 간단한 채뇨방법을 모색하게 되었다. 본 연구에서는 일차적인 선별검사를 위해 일회용 기저귀를 이용한 소변채취 방법이 기존의 멸균 비닐백을 이용한 방법을 대체할 수 있는지 알아보았다. 방 법 : 99명의 환자들을 대상으로 중간뇨(이하 신선뇨) 60 mL을 채취하여 절반은 고분자 흡수체가 포함되지 않은 일회용 기저귀에 흡수시킨 다음 압착하여 소변검체(이하 재수거뇨)를 얻고 나머지 신선뇨와 함께 일반 소변검사, 현미경적 요 세포검사 및 요 화학검사 등을 시험하였다. 결 과 : 신선뇨 99개와 재수거뇨 99개를 검사하였으며 요 비중, 요 산도, 요 당, 요 단백, 요 잠혈 등은 상관분석 결과 높은 상관관계(R>0.930, P<0.001)를 보였으며 요 백혈구(R=0.738, P<0.001)는 상대적으로 상관관계가 낮았지만 요 나트륨, 요 칼륨, 요 염소 및 요 크레아티닌 등은 두 방법간의 차이가 거의 없었다(R>0.995, P<0.001). 현미경적 요 세포검사에서는 적혈구(R=0.740, P<0.001)와 백혈구(R=0.602, P<0.001) 모두 상대적으로 상관관계가 낮았지만 통계적으로 유의한 수준이었다. 결 론 : 일회용 기저귀를 이용해 채취한 재수거뇨는 신선뇨보다 세포성분의 손실은 있지만 신선뇨의 일반 소변검사 및 요 화학검사 결과를 잘 반영하고 있어 일차적인 선별검사 목적의 채뇨방법으로 유용할 것이다.

  • PDF

삼점 신호 평균기법에 의한 요속신호의 잡음 축소 기법 (Noise Reduction Technique by Three-Points Ensemble Averaging in Uroflowmetry)

  • 최성수;이인광;이상봉;박준오;이수옥;차은종;김경아
    • 전기학회논문지
    • /
    • 제58권8호
    • /
    • pp.1638-1643
    • /
    • 2009
  • Uroflowmetry is a convenient clinical test to screen the benign prostatic hyperplasia(BPH) common in the aged men. A load cell is located beneath the urine container to measure the weight of urine. However, it is sensitive to the impact applied on the bottom of the container by the urine stream, which could be a noise source lowering the reliability of the system. With this aim, our study proposed a noise reduction technique by computing ensemble average of the weighted signals that were acquired from three-load cells forming a regular triangle beneath the urine container. Simulated urination experiment was performed with three different collection methods, all of which demonstrated significant noise reduction by ensemble averaging. Furthermore, the best results can be obtained without any special urine collection devices. Thus, our novel method can be usefully applied to uroflowmetry for enhancing measurement in terms of accuracy and reliability.

2세 미만의 열성 환아에서 소변 주머니를 이용한 소변 배양 검사의 오염률에 영향을 미치는 인자 (Factors affecting the contamination of bag urine culture in febrile children under two years)

  • 최욱현;임인석
    • Clinical and Experimental Pediatrics
    • /
    • 제52권3호
    • /
    • pp.346-350
    • /
    • 2009
  • 목 적 : 요로 감염이 의심되는 2세 미만의 소아는 소변을 가릴 수 없기 때문에, 일반적으로 소변 주머니를 이용하여 소변 검사를 시행한다. 이 검사 방법은 비칩습적인 검사이지만 오염률이 높은 단점이 있다. 이에 저자들은 소변 주머니를 이용한 소변 배양 검사의 오염률에 영향을 미칠 수 있는 인자들에 대하여 알아보았다. 방 법 : 2007년 1월부터 2007년 12월까지 중앙대학교병원 소아청소년과에 내원한 환아들 중 소변 주머니를 이용한 소변 배양 검사에서 단일균이 10만개 이상 자란 환아들을 대상으로 하였다. 소변 주머니를 재부착하였던 환아들을 제외하고, 요로 감염인 환아와 오염인 환아로 분류하여, 환아의 성별, 소변 주머니를 붙인 뒤 채취에 걸린 시간, 설사 증상의 동반 유무가 오염률에 어떤 영향을 미치는지 조사하였다. 결 과 : 872명 중에서717명의 환아가 연구에 포함되었고 환아이들 중 중 남아는 412명, 여아는 305명이었다. 37.9%의 오염률을 보였고, 성별과 오염률은 통계학적으로 유의한 차이가 없었다 (P>0.05). 소변 주머니를 붙인 뒤 소변 채취에 걸린 시간이 길어질수록 오염률이 증가하였고, 2시간 이내, 4시간 이내, 4시간 이상 10시간 이내로 세 군으로 나누어 오염률을 확인하였을 때 각각 30.0%, 42.2%, 43.7%로 통계학적으로 유의하게 증가하는 것으로 나타났다(P=0.001). 내원 당시 설사 증상의 동반 여부는 배양 검사의 오염률에 영향을 미치지 않았다(P>0.05). 결 론 : 성별 및 설사 증상 유무는 소변 주머니를 이용한 소변 배양 검사의 결과에 영향을 주지 않으며, 요로 감염이 의심되는 2세 미만의 환아에게서 2시간 이내에 소변 채취시에는 정확도를 높일 수 있다. 따라서 소변 주머니를 붙인 뒤 2시간 이상 경과된 환아에게서 독성 증상이 없다면 재소독 후 재부착을 실시하는 것이 오염률을 줄이는데 도움이 될 것으로 보인다.

Validity of bag urine culture for predicting urinary tract infections in febrile infants: a paired comparison of urine collection methods

  • Kim, Geun-A;Koo, Ja-Wook
    • Clinical and Experimental Pediatrics
    • /
    • 제58권5호
    • /
    • pp.183-189
    • /
    • 2015
  • Purpose: Catheter urine (CATH-U) and suprapubic aspiration (SPA) are reliable urine collection methods for confirming urinary tract infections (UTI) in infants. However, noninvasive and easily accessible collecting bag urine (CBU) is widely used, despite its high contamination rate. This study investigated the validity of CBU cultures for diagnosing UTIs, using CATH-U culture results as the gold standard. Methods: We retrospectively analyzed 210 infants, 2- to 24-month-old, who presented to a tertiary care hospital's pediatrics department between September 2008 and August 2013. We reviewed the results of CBU and CATH-U cultures from the same infants. Results: CBU results, relative to CATH-U culture results (${\geq}10^4$ colony-forming units [CFU]/mL) were widely variable, ranging from no growth to ${\geq}10^5CFU/mL$. A CBU cutoff value of ${\geq}10^5CFU/mL$ resulted in false-positive and false-negative rates of 18% and 24%, respectively. The probability of a UTI increased when the CBU bacterial count was ${\geq}10^5/mL$ for all infants, both uncircumcised male infants and female infants (likelihood ratios [LRs], 4.16, 4.11, and 4.11, respectively). UTIs could not be excluded for female infants with a CBU bacterial density of $10^4-10^5$ (LR, 1.40). The LRs for predicting UTIs based on a positive dipstick test and a positive urinalysis were 4.19 and 3.11, respectively. Conclusion: The validity of obtaining urine sample from a sterile bag remains questionable. Inconclusive culture results from CBU should be confirmed with a more reliable method.

Development of objective indicators for quantitative analysis of sodium intake: the sodium to potassium ratio of second-void urine is correlated with 24-hour urinary sodium excretion

  • Kim, Jung Gon;Han, Sang-Woong;Yi, Joo Hark;Park, Hyeong Cheon;Han, Sang Youb
    • Nutrition Research and Practice
    • /
    • 제14권1호
    • /
    • pp.25-31
    • /
    • 2020
  • BACKGROUND/OBJECTIVES: To date, sodium intake has been evaluated based on spot urine instead of 24-hour (hr) urine collection. Nevertheless, the optimal method for assessing daily sodium intake remains unclear. SUBJECTS/METHODS: Fifteen male (age 32.7 ± 6.5 years) participants were offered 3 meals with a total of 9-10 g salt over 24 hours, and 24-hr urine was collected from the second-void urine of the first day to the first-void urine of the second day. Twenty-four-hr urinary sodium (24UNa) was estimated using Tanaka's equation and the Korean formula, and spot urine Na, potassium (K), chloride (Cl), urea nitrogen (UN), creatinine (Cr), specific gravity (SG) and osmolality (Osm) were measured. The ratios of urinary Na to other parameters were calculated, and correlations with total measured 24UNa were identified. RESULTS: Average 24-hr urine volume was 1,403 ± 475 mL, and measured 24UNa was 143.9 ± 42.1 mEq (range, 87.1-239.4 mEq). Measured 24UNa was significantly correlated with urinary Na/UN (r = 0.560, P < 0.01), urinary Na/Osm (r = 0.510, P < 0.01), urinary Na/Cr (r = 0.392, P < 0.01), urinary Na/K (r = 0.290, P < 0.01), 24UNa estimated using Tanaka's equation (r = 0.452, P < 0.01) and the Korean formula (r = 0.414, P < 0.01), age (r = 0.548, P < 0.01), weight (r = 0.497, P < 0.01), and height (r = 0.393, P < 0.01) in all spot urine samples. Estimated 24UNa based on the second-void spot urine of the first day tended to be more closely correlated with measured 24UNa than were estimates from the other spot urine samples. The significant parameters correlated with the second-void urine of the first day were urinary Na/K (r = 0.647, P < 0.01), urinary Na/Cr (r = 0.558, P < 0.05), and estimated 24UNa using Tanaka's equation (r = 0.616, P < 0.05) and the Korean formula (r = 0.588, P < 0.05). CONCLUSIONS: Second-void urine is more reliable than first-void urine for estimating 24UNa. Urinary Na/K in the second-void urine on the first day is significantly correlated with 24UNa. Further studies are needed to establish the most reliable index and the optimal time of urine sampling for predicting 24UNa.

Effect of storage time and temperature on levels of phthalate metabolites and bisphenol A in urine

  • Guo, Ying;Wang, Lei;Kannan, Kurunthachalam
    • Advances in environmental research
    • /
    • 제2권1호
    • /
    • pp.9-17
    • /
    • 2013
  • Urine is a widely used matrix in biomonitoring studies on the assessment of human exposure to environmental chemicals such as phthalate esters and bisphenol A (BPA). In addition to the need to apply valid analytical techniques, assurance of specimen integrity during collection and storage is an important prerequisite for the presentation of accurate and precise analytical data. One of the common issues encountered in the analysis of non-persistent contaminants is whether shipping and storage temperature and time since collection have an effect on sample integrity. In this study, we investigated the stability of phthalate metabolites and BPA in spiked and unspiked urine samples stored at room temperature ($20^{\circ}C$) or at $-80^{\circ}C$ for up to 8 weeks. Concentrations of phthalate metabolites declined, on average, by 3% to 15%, depending on the compounds, and BPA declined by ~30% after 4 weeks of storage of spiked urine samples at $20^{\circ}C$. In a test of 30 unspiked urine samples stored at $20^{\circ}C$ and at $-80^{\circ}C$ for 8 weeks, the concentrations of phthalate metabolites and BPA decreased by up to 15% to 44%, depending on the compound and on the samples. It was found that the small reduction in phthalate concentrations observed in urine, varied depending on the samples. In a few urine samples, concentrations of phthalate metabolites and BPA did not decline even after storage at $20^{\circ}C$ for 8 weeks. We found a significant relationship between concentrations of target analytes in urine stored at $20^{\circ}C$ and at $-80^{\circ}C$ for 8 weeks. We estimated the half-lives of phthalate metabolites and BPA in urine stored at $20^{\circ}C$. The estimated half-life of monoethyl phthalate (mEP) and mono (2-ethyl-5-carboxyphentyl) phthalate (mECPP) in urine stored at $20^{\circ}C$ was over two years, of mono (2-ethyl-5-oxohexyl) phthalate (mEOHP) and monobenzyl phthalate (mBzP) was approximately one year, and of other phthalate metabolites was approximately 6 months. The estimated half-life of BPA in urine stored at $20^{\circ}C$ was approximately 3 months, which is much longer than that reported for aquatic ecosystems.

Demonstration of constant nitrogen and energy amounts in pig urine under acidic conditions at room temperature and determination of the minimum amount of hydrochloric acid required for nitrogen preservation in pig urine

  • Jongkeon Kim;Bokyung Hong;Myung Ja Lee;Beob Gyun Kim
    • Animal Bioscience
    • /
    • 제36권3호
    • /
    • pp.492-497
    • /
    • 2023
  • Objective: The objectives were to demonstrate that the nitrogen and energy in pig urine supplemented with hydrochloric acid (HCl) are not volatilized and to determine the minimum amount of HCl required for nitrogen preservation from pig urine. Methods: In Exp. 1, urine samples of 3.0 L each with 5 different nitrogen concentrations were divided into 2 groups: 1.5 L of urine added with i) 100 mL of distilled water or ii) 100 mL of 6 N HCl. The urine in open plastic containers was placed on a laboratory table at room temperature for 10 d. The weight, nitrogen concentration, and gross energy concentration of the urine samples were determined every 2 d. In Exp. 2, three urine samples with different nitrogen concentrations were added with different amounts of 6 N HCl to obtain varying pH values. All urine samples were placed on a laboratory table for 5 d followed by nitrogen analysis. Results: Nitrogen amounts in urine supplemented with distilled water decreased linearly with time, whereas those supplemented with 6 N HCl remained constant. Based on the linear broken-line analysis, nitrogen was not volatilized at a pH below 5.12 (standard error = 0.71 and p<0.01). In Exp. 3, an equation for determining the amount of 6 N HCl to preserve nitrogen in pig urine was developed: additional 6 N HCl (mL) to 100 mL of urine = 3.83×nitrogen in urine (g/100 mL)+0.71 with R2 = 0.96 and p<0.01. If 62.7 g/d of nitrogen is excreted, at least 240 mL of 6 N HCl should be added to the urine collection container. Conclusion: Nitrogen in pig urine is not volatilized at a pH below 5.12 at room temperature and the amount of 6 N HCl required for nitrogen preservation may be up to 240 mL per day for a 110-kg pig depending on urinary nitrogen excretion.