• Title/Summary/Keyword: urea method

Search Result 356, Processing Time 0.026 seconds

Isoconversional Cure Kinetics of Modified Urea-Formaldehyde Resins with Additives

  • Park, Byung-Dae
    • Current Research on Agriculture and Life Sciences
    • /
    • v.30 no.1
    • /
    • pp.41-50
    • /
    • 2012
  • As a part of abating formaldehyde emission of urea-formaldehyde resin, this study was conducted to investigate the rmalcure kinetics of both neat and modified urea-formaldehyde resins using differential scanning calorimetry. Neat urea-formaldehyde resins with three different formaldehyde/urea mol ratios (1.4, 1.2 and 1.0) were modified by adding three different additives (sodium bisulfite, sodium hydrosulfite and acrylamide) at two different levels (1 and 3wt%). An isoconversional method at four different heating rates was employed to characterize thermal cure kinetics of these urea-formaldehyde resins to obtain activation energy ($E{\alpha}$) dependent on the degree of conversion (${\alpha}$). The $E{\alpha}$ values of neat urea-formaldehyde resins (formaldehyde/urea = 1.4 and 1.2) consistently changed as the ${\alpha}$ increased. Neat and modified urea-formaldehyde resins of these two F/U mol ratios did show a decrease of the $E{\alpha}$ at the final stage of the conversion while the $E{\alpha}$ of neat urea-formaldehyde resin (formaldehyde/urea = 1.0) increased as the ${\alpha}$ increased, indicating the presence of incomplete cure. However, the change of the $E{\alpha}$ values of all urea-formaldehyde resins was consistent to that of the Ea values. The isoconversional method indicated that thermal cure kinetics of neat and modified urea-formaldehyde resins showed a strong dependence on the resin viscosity as well as diffusion control reaction at the final stage of the conversion.

  • PDF

Study of Vibration Fatigue Test for Urea Tank of Diesel Vehicle Considering Vibration Characteristics (디젤차량 요소수탱크의 진동 특성을 고려한 진동내구시험법 연구)

  • Yoon, Ji Soo
    • Journal of Applied Reliability
    • /
    • v.18 no.3
    • /
    • pp.213-219
    • /
    • 2018
  • Purpose: Satisfying the environmental regulations, the automobile manufacturer should install urea tank, which is a key component of the urea system. However, due to the limitations of existing layouts, it may be mounted which is disadvantageous to vibration and shock resulting in durability robust. analyze the factors affecting the durability life of urea tank and the vibration characteristics through RLDA. In this study, clarify the limit of the current practice test method of urea tank and analyze the possibility of the new vibration test method in the system unit reflecting the characteristics of actual use condition. Methods: Analyzing the factors affecting the durability life of urea tank and the vibration characteristics through PSD & FDS of RLDA that actual vehicle driving data on durability test road. Results: The limit of the uniform width/single frequency test method of urea tank is clarifed and the positive prospects of the new test method are discovered. Conclusion: The vibration durability test with PSD method in system unit effectively reflects the magnitude and frequency characteristics of field vibration.

Quantification of urea in serum by isotope dilution HPLC/MS (동위원소 희석 HPLC/MS에 의한 혈청 내 urea의 정량)

  • Lee, Hwashim;Park, Sangryoul
    • Analytical Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.271-277
    • /
    • 2005
  • Urea in blood has been measured as an effective marker for diagnosis of renal function. Urea which is e end-product of nitrogen containing metabolites such as proteins is filtered through glomeruli of kidneys and then excreted as urine. If the renal function is deteriorated, the urea concentration in blood will be increased, from which the healthiness of renal function is judged. In order to improve the confidence of diagnosis results, the results must keep traceability chain to certified reference materials, which was certified by primary reference method. In this study, we proposed isotope dilution-liquid chromatography/mass spectrometry (ID-LC/MS) as a candidate primary method, in which $15^N_2$-urea is used as an internal reference material. The developed method is highly accurate in principle and is convenient as it does not require cumbersome derivatization. 0.1 mmol/L ammonium chloride was selected as a mobile phase for HPLC because it provided low interference in MS analysis of relatively low molecular weighted urea. HPLC and MS were connected with an electrospray ionization (ESI) interface of positive mode, which provided high sensitivity and reproducibility. The developed method was validated with internationally recognized reference materials, and we have obtained satisfactory results in an international ring trial. The expanded uncertainty calculated according to ISO guide was 1.8% at 95% confidence interval. The developed method is being used as a primary reference measurement method such as for certification of serum certified reference materials (CRMs).

Preparation of Sodiumisocyanate and its Analyzing Method in the Presence of Impurities $Na_2CO_3$, Urea, and Biuret (Sodium Isocyanate의 제법 및 $Na_2CO_3$, Urea, Biuret 혼재시 그의 정량분석법에 관한 연구)

  • 국채호
    • YAKHAK HOEJI
    • /
    • v.7 no.2_3
    • /
    • pp.67-71
    • /
    • 1963
  • Studies the reaction mechanism and optimal reaction condition of the process of preparing sodium isocyanate, by means of heating of sodium carbonate and urea. Proposing, at the sametime, the quantitative analyzing method of sodium isocyanate in the presence of impurities of $Na_{2}CO_{3}$, urea and biuret. 1. Sodium isocyanate could be prepared by means of heating reaction of sodium carbonate and urea. 2. Adding urea into the heated sodium carbonate is reasonable. 3. Quantitative analysis of sodium isocyanate in the presence of impurities, $Na_{2}CO_{3}$, urea and biuret could be done by the following method:-adding nitrobarite solution into sample solution in order to remove $CO_{3}"$ and neutralize the solution, filtering off $BaCO_{3}$, and then precipitating isocyanate as a silver salt, filtering off AgNCO, and then, titrating remaining $AgNO_{3}$ with $NH_{4}SCN$, (indicator $FeNH_{4}(SO_{4})_{2})$/TEX>

  • PDF

Fertilizer Placement Effect on Agronomic Characteristics of Burley Tobacco(N. tabacum L.) (시비방법이 버어리종 잎담배의 농경적 특성에 미치는 영향)

  • 조천준;배성국;임해건;김요태
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.19 no.1
    • /
    • pp.33-39
    • /
    • 1997
  • Recently the method of basal compound fertilizer (N : P : K = 18.2 : 9.8 : 35.0) Placement has been changed from banding to broadcasting in tobacco cultivation. The effects of the compound fertilizer placement, level of fertilizer and additional urea application on the agronomic characteristics, two chemical compositions and physical Properties of burley tobacco(Nicotiana tabacum L. cv. KB 108) were investigated at Chonju Experiment Station, Korea Ginseng and Tobacco Research Institute in 1995-1996. Six treatments consisted of (1) band (method of fertilizer Placement) + In kg/10a(compound fertilizer) + 0(additional urea applied), (2) broadcast+140+0, (3) broadcast+140+25, (4) band+180+0, (5) broadcast+180+0, and (6) broadcast +180+25. The additional urea was applied at hilling. No significant differences were detected between banding and broadcasting method of compound fertilizer Placement in field 9rowth, wield, organoleptic qualify(price Per kilogram), chemical composition and Physical properties of cured leaf, The increased compound fertilizer by 30%(40k/10a) or the additional urea application by 25kg per 10a produced slightly higher yield than the recommended amount of basal compound fertilizer without additional urea application did. It also increased the total alkaloid content of cured leaf. It is recommended that no more basal fertilizer above the recommended amount and no additional urea application are needed in burley tobacco fertilization, even though the method of basal fertilizer placement being chanced from banding to broadcasting. Key words : Nicotiana tabacum, fertilizer placement, additional urea.

  • PDF

Development of Voltammetric Urea Sensors Based Poly(3-methylthiophene) film (Poly(3-methylthiophene)막 위에 urease를 고착시킨 Voltammetric Urea Sensor의 개발)

  • 박성호;진준형;홍석인;민남기
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.314-316
    • /
    • 2000
  • Urea is detected as an indicator of renal disease in the human body. For these reasons, many biosensors for urea have been developed based on the enzymatic reaction of urea hydrolysis catalyzed by urease. Potentiometric method is applied reversible reaction system. But urea hydrolysis reaction may not has a reversible reaction mechanism in electrode surface. Therefore we applied to voltammtricmethod to obtain a sensitivity curve. The sensitivity of sensors was 34 ${\mu}$A/decade.

  • PDF

ON FARM DEMONSTRATION OF VARIOUS STORAGE METHODS FOR UREA TREATED WHEAT STRAW

  • Khan, A.G.;Ullah, W.;Azim, A.;Ali, A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.9 no.3
    • /
    • pp.281-285
    • /
    • 1996
  • On farm demonstration of urea treatment (5 kg urea dissolved in 60 litre water/100kg) of straw was performed at 6 different sites and treated straw was stored by three different methods i.e., plastic covered, mud plastered and existing farmers technique (mud plastered on the top and open from sides) to determine the best storage method in field. Untreated and treated samples were taken after 5 week storage period and subjected to crude protein, crude fibre and cell wall constituents analysis. In situ dry matter digestibility of straw was measured by nylon bag technique in buffalo bulls. Crude protein content increased by 100 to 153 percent in treated straw stored by different methods. Maximum increase in crude protein of treated straw was noticed in mud plastered method. Urea treatment of straw resulted in significant decrease in crude fibre contents in all the storage methods. Treatment of straw enhanced the in situ digestibility by 25-49 percent and maximum digestibility (53%) was found in mud plastered storage method. It was concluded that the mud plastered storage method for urea treated straw was found to be the best at farm level.

Effects of Mixing Ratio of Urea and Mlelamine on Formaldehyde Emission and Bonding Properties of Plywoods Manufactured with Urea-Melamine Formaldehyde Adhesives (요소-멜라민 공축합 수지의 요소와 멜라민 혼합비율이 합판의 포름알데히드 방출과 접착성에 미치는 영향)

  • Park, Heon;Kang, Eun-Chang;Min, Kyeong-Heui
    • Journal of the Korea Furniture Society
    • /
    • v.11 no.1
    • /
    • pp.53-59
    • /
    • 2000
  • This study was to measure formaldehyde emission and bonding strength of plywoods manufactured with urea-melamine formaldehyde adhesives, which were made from three different mixing ratios of urea and melamine, and with four different formaldehyde/urea-melamine molar ratios of 1.0,1.1,1.2 and 1.4. The results were as follows 1. Amount of formaldehyde emission was the lowest at the first method of molar ratio(F/(M+U)) 1.0. Amounts of formaldehyde emission of experimental manufactured adhesives were lower than that of commercial adhesive. 2. Bonding strength of dry specimen was the highest at the first method of molar ratio(F/(M+U)) 1.4. Dry bonding strength of molar ratio(F/(M+U)) 1.4 was similar to commercial adhesive. 3. Bonding strength of wet specimen was the highest at the second method of molar ratio(F/(M+U)) 1.4. Bonding strength of wet specimen used by the third method of molar ratio(F/(M+U)) 1.4 was almost equal to commercial adhesive.

  • PDF

Studies on the growth of organic single crystals of urea and THAMP (Urea와 THAMP 유기 단결정의 육성에 관한 연구)

  • 임창성;황완인;김판채
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.5 no.3
    • /
    • pp.223-232
    • /
    • 1995
  • Abstract Urea($(NH_2)_2CO$) and THAMP (Tris(hydroxymethyl) aminomethane phosphate) are new organic nonlinear optical materials (NLO) for the device application such as the frequency conversion of laser radiation. The single crystals of urea and THAMP have been grown by the falling temperature method and the temperature difference method. The crystal growth parameters were presented associated with the molphology of the grown crystals. Based on the solubility measurements, methanol was a suitable solvent for the growth of urea. The solubilities of urea have a positive temperature coefficient and the heat of solution of urea was estimated to be -2.58 kcal/mol. The grown crystals of urea have the preferential growth habit in the z-axis. Additives such as $NH_4_H_2PO_4$, KCL, $H_3PO_4$, $CaCl_2{\cdot}2H_2O$, $C_2H_5OH$ were used for the favourable growth in the x - and y-axis and the preventive growth in the z-axis. The moleratio of THAM and H3P04 for the solution of THAMP was 1 : 1. The solubilities of THAMP have a positive temperature coefficient. The heat of solution was estimated to be - 1.70 kcal/ mol.

  • PDF

Development of an Urea Sensor using Electric Conductivity Method (전기전도도법을 이용한 우레아 농도 센서 개발)

  • Choi, B.C.;Kim, K.Y.;Yang, J.Y.;Kim, H.N.
    • Journal of Power System Engineering
    • /
    • v.15 no.2
    • /
    • pp.55-60
    • /
    • 2011
  • The popularity of diesel engines is derived primarily from their higher thermal efficiency resulting from higher compression ratio. NOx removal from the diesel emissions is very important to meet stringent emission regulations. NOx emission from diesel engines is removed by an urea-SCR or an LNT system. The urea-SCR system needs the urea-solution supply system with concentration and level sensor. This study was carried out to develop a sensor for the measurement of urea-solution concentration by an electric conductivity method. Considering experimental parameters were the material of electrode, two kinds of electric power(AC or DC), the distance between two electrodes, and the length of electrode. It was found that the AC electric power was more useful to measure the urea-solution concentration compared to DC, because it prevented an ionization of the urea-solution. The silver rod coated with Pt is the most useful electrode, tendency of which is similar to Pt rod, and the cost is more economic. We could also find out the optimum distance between two electrodes and the length of electrode was 10mm and 3mm, respectively.