• Title/Summary/Keyword: urban residential performance

Search Result 70, Processing Time 0.021 seconds

Application of Buckling Restrained Braces in a 50-Storey Building

  • Sy, Jose A.;Anwar, Naveed;Aung, Thaung Htut;Rayamajhi, Deepak
    • International Journal of High-Rise Buildings
    • /
    • v.3 no.1
    • /
    • pp.81-87
    • /
    • 2014
  • The use of Buckling Restrained Braces (BRB) for enhancing the performance of the buildings is gaining wider acceptance. This paper presents the first application of these devices in a major high-rise building in the Philippines. A 50-storey residential reinforced concrete building tower, with ductile core wall, with BRB system is investigated. The detailed modeling and design procedure of buckling restrained brace system is presented for the optimal design against the two distinct levels of earthquake ground motions; serviceable behavior for frequent earthquakes and very low probability of collapse under extremely rare earthquakes. The stiffness and strength of the buckling restrained brace system are adjusted to optimize the performance of the structural system under different levels of earthquakes. Response spectrum analysis is conducted for Design Basis Earthquake level and Service level, while nonlinear time history analysis is performed for the most credible earthquake. The case study results show the effectiveness of buckling restrained braces.

A Study of Zero Energy Building Verification with Measuring and Model-based Simulation in Exhibition Building

  • Ha, Ju-wan;Park, Kyung-soon;Kim, Hwan-yong;Song, Young-hak
    • Architectural research
    • /
    • v.20 no.3
    • /
    • pp.93-102
    • /
    • 2018
  • With the change in Earth's ecosystems due to climate change, a number of studies on zero energy buildings have been conducted globally, due to the depletion of energy and resources. However, most studies have concentrated on residential and office buildings and the performance predictions were made only in the design phase. This study verifies the zero-energy performance in the operational phase by acquiring and analyzing data after the completion of an exhibition building. This building was a retention building, in which a renewable energy system using a passive house building envelope, solar photovoltaic power generation panels, as well as fuel cells were adopted to minimize the maintenance cost for future energy-zero operations. In addition, the energy performance of the building was predicted through prior simulations, and this was compared with actual measured values to evaluate the energy performance of the actual operational records quantitatively. The energy independence rate during the measurement period of the target building was 123% and the carbon reduction due to the energy production on the site was 408.07 tons. The carbon reduction exceeded the carbon emission (331.5 tons), which verified the carbon zero and zero-energy performances.

Distribution of Airborne Hexavalent Chromium Concentrations in Large Industrial Complexes in Korea

  • Kang, Byung-Wook;Lee, Hak-Sung;Kim, Jong-Ho;Hong, Ji-Hyung;Kim, Rok-Ho;Seo, Young-Kyo;Han, Jin-Seok;Baek, Kyung-Min;Kim, Min-Ji;Baek, Sung-Ok
    • Asian Journal of Atmospheric Environment
    • /
    • v.10 no.4
    • /
    • pp.208-216
    • /
    • 2016
  • This paper reports the results of a field evaluation which used sampling and analytical methods to determine the levels of airborne hexavalent chromium Cr(VI) in major industrial complexes in Korea over a seven year period (2007-2013). Cr(VI) concentrations were determined using cellulose filter sampling and ion chromatography analysis. In order to validate the analytical performance of these methods, studies were also carried out to investigate data quality control (QC) parameters, such as the method detection limit (MDL), repeatability, and recovery efficiencies. The average concentrations of Cr(VI) for the nine industrial complexes in Korea were in the range of 0.09 to $1.40ng/m^3$, which is similar to of the concentrations in other industrial areas around the world. The impacts of Cr(VI) emissions from industrial areas on Cr(VI) concentrations in neighboring-residential areas were considerably low, and the dispersion of Cr(VI) from industrial areas to residential areas was estimated to be 'not-significant'. Cr(VI) levels were not affected by seasonal variation, which suggests that chromium was emitted continuously from the industrial sources throughout the year. The concentration of Cr(VI) measured accounted for 0.7 to 9.4 percent of the total chromium level, which is a low percentage compared to those in other urban areas around the world. This is the first report in an international journal of a field study conducted in Korea to determine the concentration of Cr(VI) in the ambient air of industrial and residential areas.

Study of Energy Cost for Performing Flush-out in Newly Constructed Multi-residential Buildings during Winter Season (겨울철 신축 공동주택의 플러쉬아웃 시행 시 난방비용에 관한 연구)

  • Lee, Ki Yong;Kim, Kee Han;Park, Jun-Seok
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.3
    • /
    • pp.110-114
    • /
    • 2016
  • Newly constructed multi-residential buildings with more than 500 households should be flushed out indoor contaminants using a mechanical ventilation system or large fans after the completion of construction and prior to occupancy by the Heath-friendly Housing Construction Standards since 2014. In addition, the standard recommends to maintain indoor temperature over $16^{\circ}C$ and relative humidity below 60% while performing the flush-out. However, it is difficult to maintain these recommended indoor conditions, especially during winter season because additional energy cost is needed for space heating. Therefore, in this study, additional energy cost including heating and ventilation energy cost in multi-residential household for flush-out during winter season was estimated using building energy simulation program called EnergyPlus. Additional energy cost according to various conditions for performing flush-out (such as performance period, ventilation rate, and heating set-point temperature) was analyzed. Based on the results of the energy simulation, the energy cost was estimated to be ranged from 14,625 to 29,452\/household in Incheon city and from 3,521 to 26,268\/household in Gwangju City. There was no significant change in energy cost according to the performing terms of flush-out between Incheon and Gwangju City.

A Study on the Effective Installation to the Apartment Through Solar Collector Performance Test (태양열 집열기 성능실험을 통한 공동주택 효율적 설치방안 연구)

  • Kim, Mi-Yeon;Choi, Byung-Do;Kim, Hyung-Geun;Park, Jin-Chul
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.480-487
    • /
    • 2012
  • The application of solar energy in residential building is general and natural in today. And application methods of solar thermal energy is divided in two kind of form, single evacuated tube and flat-plate form. Then in this study, the efficiency of single evacuated tube and flat-plate system is compared by total and effective area considering the time receiving the solar radiation between 24 hours and the specific time(10:00~15:00). As a result of the experiment, single evacuated tube and flat-plate collector's efficiency is varied by the quantity of solar radiation. And especially, the flat-plate system is more affected by outdoor temperature. Therefore the application of solar thermal system should be considered the solar radiation and outdoor temperature.

  • PDF

A Study on Resurvey of Cadastre Business Efficiency Measurement Methods Residential Areas (지적재조사사업 주택밀집 지역 측량 방법의 효율성에 관한 연구)

  • Choe, Cho-Won;Shin, Soon-Ho
    • Journal of Cadastre & Land InformatiX
    • /
    • v.45 no.1
    • /
    • pp.181-191
    • /
    • 2015
  • In the present study, the 2013 survey Uiwang pointed out how the Resurvey of Cadastre ed projects reviewed relation to the business carried GPS-RTK (Network, Single) and total station surveying (T/S) to analyze and to compare the performance of Time Measurement Accuracy urban areas Resurvey of Cadastre was to present an effective survey methods in the business district. In this study, Uiwang review survey results indicated a comprehensive evaluation of the results, which are concentrated in urban areas, the building of intelligent review of GPS-RTK surveying methods is avoided by the measurement method to establish the first principles method based on total station surveying the GPS-RTK survey to draw conclusions appropriated to take advantage of the assistance and inspection methods.

Evaluation of Ventilation Performances for Various Combinations of Inlets and Outlets in a Residential Unit through CO2 Tracer-Gas Concentration Decay Method (CO2 추적가스 농도감소법을 이용한 공동주택의 급·배기구 조합에 따른 환기 성능 분석)

  • Sang Yoon Lee;Soo Man Lee;Jong Yeob Kim;Gil Tae Kim;Byung Chang Kwag
    • Land and Housing Review
    • /
    • v.14 no.4
    • /
    • pp.111-120
    • /
    • 2023
  • Indoor air quality has become increasingly important with the increase in time spent in residential environments, impact of external fine dust, yellow dust, and the post-COVID 19 pandemic. Residential mechanical ventilation plays a key role in addressing indoor air quality. The legal standard for residential air changes per hour in Korea is 0.5 ACH. However, there are no standards for the location of supply and return vents. This study atempts to analyze the impact of ventilation performance based on the location of supply and return vents. An experiment was conducted using the CO2 tracer gas concentration decay method in a mock-up house set inside a large chamber to minimize external influences. The experimental results indicated that the commonly used combination of 2 supply and 2 return vents in living room spaces had a lower mean age of air than the combination of 1 supply and 2 return vents. Using multiple supply and return vents had lower mean age of air than using just 1 supply and 1 return vent.

A Study on the Performance Analysis of Environmental Improvement Fund for the Structural Advancement Project of the Old Industrial Complex (노후산업단지 구조고도화사업을 위한 환경개선펀드 성과분석에 관한 연구)

  • Kim, Jongha;Chung, Jaeho
    • Land and Housing Review
    • /
    • v.11 no.3
    • /
    • pp.21-31
    • /
    • 2020
  • This paper quantitatively analyzes the investment performance of the environmental improvement fund focusing on the sales effect and the housing benefit effect. The analysis of this study focused on the effects of sales and housing benefits for completed business sites among the business sites supported by the Environmental Improvement Fund. The analysis results are as follows. First, it appears that the sales effect of the completed workplace is effective compared to the amount of investment, so it seems that the purpose of industrial integration of the environment improvement fund is being achieved. Second, it was found that there are variations by workplace and region in housing benefits. This seems to be due to the fact that profitability can be neglected by reflecting the characteristics of residential facilities built by private businesses. The Environmental Improvement Fund is a policy fund that pursues both profitability and publicity. Therefore, it is necessary to transform the structure of the fund to expand support for industrial infrastructure with high publicity. To this end, it is necessary to establish a long-term management plan that equitably considers the profitability and publicity of the environmental improvement fund.

Strength Demand Calculation for Retrofitting Unreinforced Masonry Buildings Based on the Displacement Coefficient Method and the Preliminary Seismic Evaluation Procedure (변위계수법 및 약산식 내진성능평가에 기초한 비보강 조적조 건물의 내진보강 요구강도 산정)

  • Seol, Yun Jeong;Park, Ji-Hun;Kwak, Byeong Hun;Kim, Dae Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.26 no.1
    • /
    • pp.31-38
    • /
    • 2022
  • Based on the nonlinear static analysis and the approximate seismic evaluation method adopted in "Guidelines for seismic performance evaluation for existing buildings, two methods to calculate strength demand for retrofitting individual structural walls in unreinforced masonry buildings are proposed." The displacement coefficient method to determine displacement demand from nonlinear static analysis results is used for the inverse calculation of overall strength demand required to reduce the displacement demand to a target value meeting the performance objective of the unreinforced masonry building to retrofit. A preliminary seismic evaluation method to screen out vulnerable buildings, of which detailed evaluation is necessary, is utilized to calculate overall strength demand without structural analysis based on the difference between the seismic demand and capacity. A system modification factor is introduced to the preliminary seismic evaluation method to reduce the strength demand considering inelastic deformation. The overall strength demand is distributed to the structural walls to retrofit based on the wall stiffness, including the remaining walls or otherwise. Four detached residential houses are modeled and analyzed using the nonlinear static and preliminary evaluation procedures to examine the proposed method.

The Set of Performance Evaluation Index of Remodeling in Rural Housing for Residential Environments Improvement (주거환경개선을 위한 농촌주택 리모델링 성능평가지표 설정에 관한 연구)

  • Kim, Hye-Lan;Lim, Chang-Su;Kim, Eun-Ja;Hong, Kwang-Woo;Moon, Ho-Gyeong
    • Journal of Korean Society of Rural Planning
    • /
    • v.20 no.1
    • /
    • pp.1-12
    • /
    • 2014
  • Living environments in rural area have become deteriorated rapidly. Increase of aging population, decline in agricultural income, polarization of wealth in rural community due to rural returners have caused severe decline and imbalance of living environments in rural area. Responding to this circumstances, governments currently develop projects for improving living environments focusing on individual housing which were excluded from governmental supports because those had been regarded as private property. Nevertheless, there are still some gaps and problems in evaluating the quality of living environment and suggesting effective solutions. It would be because standards and guidelines of the projects have been based on urban housing system. In order to support the implementation of the projects, this research has developed an index for evaluating and monitoring the quality of living environments in rural area. By applying Delphi method, the index has been created in four categories of 'security', 'convenience', 'comfortability', and 'durability' 'Security' consists of structural safety, crime, disaster, accident prevention. 'Convenience' includes three divisions of living, traffic, farm working. 'Comfortability' is divided into sanitation, indoor environments, and aesthetic appreciation. Lastly, 'durability' has four divisions of energy conservation, environmental friendliness, efficiency, and economics. Each sub-division also has different items from three to twelves. In the case of an index for performance evaluation, items have been derived from energy conservation(6-items), and environmental friendliness(7-items). Items developed as an index for evaluating rural living environments in this research might be good background information for remodeling project in rural housing development.