• Title/Summary/Keyword: upstream direction

Search Result 172, Processing Time 0.026 seconds

Dynamic Characteristics of Truss-Type Lift Gate According to Installation Direction (트러스형 리프트 게이트의 설치방향에 따른 진동 특성)

  • Lee, Seong-Haeng;Kong, Bo-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.120-127
    • /
    • 2016
  • This study examined the dynamic characteristics of the gate to identify the optimal gate installation direction according to the installation direction. A 1:31 scale model was constructed for a 47.5m prototype gate using acrylic. The scaled weights were tuned by adding lead weights. The first step was to measure the natural frequencies of the model gates, and compare them with finite-element analysis of the prototypes as a calibration. The scaled model was tested in a 1.6 m wide concrete flume for two orientations to determine the effects of the gate orientation on structural vibrations. Vertical vibrations were measured under a range of operational conditions, including a range of bottom opening heights and different upstream and downstream water levels. For large bottom opening heights in the normal direction, relatively large vibrations were induced by vortices shed at the plate bottom that would strike the horizontal truss member. This phenomenon was avoided in the reverse direction. For small bottom opening heights in the normal direction, these vibrations were caused by a suction force that developed at the gate bottom. The gate model in the reverse direction was preferred because of its low overall vibrational response under general gate opening and flow level combinations.

Phenomena of Liquid Jet Breakup in High Speed Gas Stream (고속유동장내 액체분열현상)

  • Park, Y.K.;Seok, J.K.;Lee, C.W.
    • Journal of ILASS-Korea
    • /
    • v.1 no.2
    • /
    • pp.66-73
    • /
    • 1996
  • The present study investigates experimentally the characteristics of liquid jet, which is, the spray flow in the normal direction of the air stream under the flow conditions of air velocity $110\sim125m/s$. The present study adopts with the flow visualization technique using a short duration light bulb and the image processing analyse with CCD camera. Two types of injector were used: one is a flat plate type, and the other is backward facing step type, which height are 5, 8, 10mm. Dispersion of liquid jet can be represented by gray level of CCD camera. In the upstream of liquid jet, the backward facing step shows better liquid jet penetration. However, in the downstream. mean droplet size for backward facing step injector is smaller than that for flat plate injector

  • PDF

Three Dimensional Flow Structure under Rotating Stall in an Axial Flow Fan (주기적 선회실속이 발성하는 축류홴의 3차원 유동구조)

  • Kang, Chang Sik;Shin, You Hwan;Kim, Kwang Ho
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.105-110
    • /
    • 2002
  • Experimental study was conducted to reveal the instability such as leakage flow and rotating stall in an axial flow fan. For this study, unsteady total pressure probe and multi-hole pressure probe were specially designed for measuring the flow field upstream and downstream of rotor. The measured pressure signal was analyzed by Single and Double Phase Locked Averaging Technique. From the result of total pressure fields at inlet and outlet of the rotor, the useful information on the structure of the stall cell in radial direction was provided. Also, detailed flow measurements were carried out with a specially designed high frequency multi-hole pressure probe, providing some insight to the leakage flow and their interation.

  • PDF

Effects of Port Masking on Part Load Performance: Part I - Lean Misfire Limit (포트 마스킹이 엔진의 부분부하 성능에 미치는 영향: Part I - 희박연소 한계)

  • 이원근;엄인용
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.5
    • /
    • pp.17-22
    • /
    • 2001
  • This paper is the first of companion papers, which investigate port-masking effects on lean misfire limit. Port-masking was applied to commercial SOHC 3-valve and DOHC 4-valve engine by inserting masking plates between manifold and port. To induce various conditions of stratification, six types of masking plates were applied. The masking plates were placed in the upstream of injector to prevent wall wetting and two ports were not separated to permit both fuel and air entering through masked port. The results were compared with those by conventional port throttling. The results show that lean misfire limit mainly depends on masking direction, that is, high lean misfire limit is achieved when the port near the spark plug is masked. The mechanism of stratification by masking is different from axial stratification by port throttling. In this case, the rich mixture entering through masked port plays a very important role in the stratification process.

  • PDF

Air Flow Rate Measurement in Multi Point Injection Engine U sing Ultrasonic Sensors (초음파센서를 이용한 전자식 연료분사엔진의 흡기유량측정)

  • Park, K.S.;Kim, J.I.;Kauh, S.K.;Noh, S.T.;Lee, J.H.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.3 no.3
    • /
    • pp.58-65
    • /
    • 1995
  • In this study an air flow meter was developed for MPI engine using ultrasonic sensors. The major characteristcs of the ultrasonic flow meter are high speed response, flow direction recognition and linear output. The air flow rate measurements were conducted at upstream of the throttle and intake manifold. The characteristics of the ultrasonic flow meter are compared with those of the Bosch hot wire flow meter at both steady and unsteady engine conditions.

  • PDF

Flow Analysis of Cryogenic Check Valve for LNG (냉열발전을 위한 극저온 체크밸브의 유동해석)

  • Moon, Jung-Hyun
    • Journal of Power System Engineering
    • /
    • v.20 no.1
    • /
    • pp.5-10
    • /
    • 2016
  • Swing check valve is opened when the flow direction is forward, when the flow is reversed, the valve is automatically closed by back pressure. In this study, the internal flow field analysis of the valve was conducted by Fluent. The working fluid used in the study, using liquefied methane $-165^{\circ}C$ (CH4) and velocity field, pressure field, pressure drop coefficient were simulated by varying separately the opening divergence into four intervals from 0 to 100%. The approximate research result are as follow : When the opening divergence is smaller, it appears high pressure on the upstream side, this value is relaxed when the opening divergence is large. Flow rate coefficient of the valve shows a larger value as the degree of opening becomes larger, confirming that the check valve used in the study is in the effective flow rate counting range.

APPLICATION OF DEMs OF LIDAR DATA IN HYDROLOGY MODELING

  • Son Min-Ho;Lee Woo-Kyun;Kwak Doo-Ahn
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.519-521
    • /
    • 2005
  • In recent years, LiDAR(Light Detection and Ranging) data has been widely used to prepare digital elevation models(DEMs) with the high spatial resolution of centi-meters. This paper investigated possible applications of LiDAR-derived DEMs in surface hydrology modeling, such as characterizing flow direction, identifying sub-basins in a watershed, and calculating variables like upstream contribution area. The results were compared to the results of the DEMs from conventional topographic maps.

  • PDF

Geometrical dimensions effects on the seismic response of concrete gravity dams

  • Sevim, Baris
    • Advances in concrete construction
    • /
    • v.6 no.3
    • /
    • pp.269-283
    • /
    • 2018
  • This study presents the effects of geometrical dimensions of concrete gravity dams on the seismic response considering different base width/dam height (L/H) ratios. In the study, a concrete gravity dam with the height of 200 m is selected and finite element models of the dam are constituted including five different L/H ratios such as 0.25, 0.5, 0.75, 1.00, 1.25. All dams are modeled in ANSYS software considering dam-reservoir-foundation interaction. 1989 Loma Prieta earthquake records are applied to models in upstream-downstream direction and linear time history analyses are performed. Dynamic equilibrium equations of motions obtained from the finite element models of the coupled systems are solved by using Newmark time integration algorithm. The seismic response of the models is evaluated from analyses presenting natural frequencies, mode shapes, displacements and principal stresses. The results show that the L/H ratios considerably affect the seismic response of gravity dams. Also, the model where L/H ratio is 1.00 has more desirable results and most appropriate representation of the seismic response of gravity dams.

Analysis of a Putative DNA Polymerase I gene in Brevibacterium ammoniagenes. (Brevibacterium ammoniagenes의 DNA Polymerase I 유사 유전자의 분석)

  • 오영필;윤기홍
    • Microbiology and Biotechnology Letters
    • /
    • v.30 no.2
    • /
    • pp.105-110
    • /
    • 2002
  • The sequence of 3,221 nucleotides immediately adjacent to rpsA gene encoding 30S ribosomal protein S1 of Brevibacterium ammoniagenes was determined. A putative open reading frame (ORF) of 2,670 nucleotides for a polypeptide of 889 amino acid residues and a TAG stop codon was found, which is located at a distance of 723 nucleotides upstream from rpsA gene with same translational direction. The deduced amino acid sequence of the ORF was found to be highly homologous to the DNA polymerase I of Streptomyces griseus (75.48%), Rhodococcus sp. ATCC 15963 (56.69%), Mycobacterium tuberculosis (55.46%) and Mycobacterium leprae (53.99%). It was suggested that the predicted product of the ORF is a DNA polymerase I with three functional domains. Two domains of 5 → 3 exonuclease and DNA polymerase are highly conserved with other DNA polymerase I, but 3 → 5 exonuclease domain is less conserved.

On the artificially-upstream flux splitting method

  • Sun M.;Takayama K.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.156-157
    • /
    • 2003
  • A simple method is proposed to split the flux vector of the Euler equations by introducing two artificial wave speeds. The direction of wave propagation can be adjusted by these two wave speeds. This idea greatly simplifies the upwinding, and leads to a new family of upwind schemes. Numerical flux function for multi-dimensional Euler equations is formulated for any grid system, structured or unstructured. A remarkable simplicity of the scheme is that it successfully achieves one-sided approximation for all waves without recourse to any matrix operation. Moreover, its accuracy is comparable with the exact Riemann solver. For 1-D Euler equations, the scheme actually surpasses the exact solver in avoiding expansion shocks without any additional entropy fix. The scheme can exactly resolve stationary contact discontinuities, and it is also freed of the carbuncle problem in multi­dimensional computations.

  • PDF