This paper presents an efficient approach to the determination of the buckling loads of down-aisle, spliced, unbraced, pallet rack structures subjected to vertical and horizontal loads. A pallet rack structures is analysed by considering the stability equations of an equivalent free-sway column. The effects of semi-rigid beam-to-upright, splice-to-upright and base-plate-to-upright connections are fully incorporated into the analysis. Each section of upright between successive beam levels in the pallet rack is considered to be a single column element with two rotational degrees of freedom. A computer algebra package was used to determine modified stability equations for column elements containing splices. The influence of the position of splices in a pallet rack is clearly demonstrated.
Zhao, Xianzhong;Huang, Zhaoqi;Wang, Yue;Sivakumaran, Ken S.
Steel and Composite Structures
/
v.33
no.3
/
pp.357-373
/
2019
Steel storage racks are slender structures whose overall behavior and the capacity depend largely on the flexural behavior of the base-plate to upright connections and on the behavior of beam-to-column connections. The base-plate upright connection assembly details, anchor bolt position in particular, associated with the high-rise steel storage racks differ from those of normal height steel storage racks. Since flexural behavior of high-rise rack base connection is hitherto unavailable, this investigation experimentally establishes the flexural behavior of base-plate upright connections of high-rise steel storage racks. This investigation used an enhanced test setup and considered nine groups of three identical tests to investigate the influence of factors such as axial load, base plate thickness, anchor bolt size, bracket length, and upright thickness. The test observations show that the base-plate assembly may significantly influence the overall behavior of such connections. A rigid plate analytical model and an elastic plate analytical model for the overall rotations stiffness of base-plate upright connections with concentric anchor bolts were constructed, and were found to give better predictions of the initial stiffness of such connections. Analytical model based parametric studies highlight and quantify the interplay of components and provide a means for efficient maximization of overall rotational stiffness of concentrically anchor bolted high-rise rack base-plate upright connections.
Due to the industrial development some scholars insist that homo sapiens has become a new race--homo sedens. Since this great degree of behavioral change often cause problems in the spinal column, the appropriate sitting became critical. The nineteenth-century idea of sitting upright position is not considered as a proper sitting any longer. Recent studies by such psychological scientists as A. C. Mandal, Ernest McCormick, and Karl Kroemer show that the spinal column in s-curve with forward bends should be efficiently supported in that manner. Designing a chair sometimes focuses on aesthetic points rather than true ergonomic considerations. Therefore, these result in deleterious effects on human bodies such as lordosis and kyphosis. In fact, it has been overlooked due to the lack of technical and scientific supports. Also, in a mass production, it is hard to meet everyone's need. However, the well adapted ergonomic considerations should meet the needs for wide ranges of people. Indeed, in this study we will examine designing chairs in ergonomic perspectives and suggest additional controversial points and alternatives.
The estimation of moment and rotation in steel rack connections could be significantly helpful parameters for designers and constructors in the initial designing and construction phases. Accordingly, Extreme Learning Machine (ELM) has been optimized to estimate the moment and rotation in steel rack connection based on variable input characteristics as beam depth, column thickness, connector depth, moment and loading. The prediction and estimating of ELM has been juxtaposed with genetic programming (GP) and artificial neural networks (ANNs) methods. Test outcomes have indicated a surpass in accuracy predicting and the capability of generalization in ELM approach than GP or ANN. Therefore, the application of ELM has been basically promised as an alternative way to estimate the moment and rotation of steel rack connection. Further particulars are presented in details in results and discussion.
The cold-formed steel storage racks are extensively employed in various industries applications such as storing products in reliable places and storehouses before distribution to the market. Racking systems lose their stability under lateral loads, such as seismic actions due to the slenderness of elements and low ductility. This justifies a need for more investigation on methods to improve their behavior and increase their capacity to survive medium to severe loads. A standardized connection could be obtained through investigation on the moment resistance, value of original rotational stiffness, ductility, and failure mode of the connection. A total of six monotonic tests were carried out to determine the behavior of the connection of straight 2.0 mm, and 2.6 mm thickness connects to 5 lug end connectors. Then, the obtained results are benched mark as the original data. Furthermore, an extreme learning machine (ELM) technique has been employed to verify and predict both moment and rotation results. Out of 4 connections, increase the ultimate moment resistance of connection by 13% and 18% for 2.0 mm and 2.6 mm upright connection, respectively.
The Journal of Korean Academy of Orthopedic Manual Physical Therapy
/
v.9
no.1
/
pp.29-38
/
2003
The purpose of this study was to investigate relationship of lumbar extensor muscle power & spinal column curve for old female patients with LDK(Lumbar degenerative kyphosis). Subjects were composed of 37 old female with LDK. The subjects were tested in their spinal segment movement and spinal column curve with Spinal-$Mouse^{\leq}$ in $1^{st}$ loaded test and $2^{nd}$ loaded test and then tested lumbar extensor muscle power with $Medx^{\leq}$ lumbar extension machine. The results of this study, were as follow; There were statistically significant difference $1^{st}$ loaded test and $2^{nd}$ loaded test in upright position increase spinal column forwardly(p<0.01) and decrease lumbar lordosis angle(p<0.01), but no statistically significant difference $1^{st}$ loaded test and $2^{nd}$ loaded test thoracic and hip & sacrum curve angle. Their lumbar extensor muscle poser is very weakness, 61.4% of normal people.
Alignment of the hip joint and pelvis affects it's weight-bearing capabilities as well as the motion available at the joints. The normal hip joint is well designed to withstand the forces that act through and around it, assisted by the trabecular systems, cartilagious, muscles, and ligaments. Alterations in the direction or magnitude of forces action around the injury and degenerative changes. The integration of motion of the pelvis with motion of the vertebral column not only increases the ROM available to the total column but also reduces the amount of flexibility required of the lumbar lesion. In any instance in which there is normal or abnormal pelvic motion during weight hearing and the head must remain upright, compensatory motions of the lumber spine will occur if available. The motions that occur at the hip, pelvis, and lumbar spine during forward trunk bending with the motions that occur during anterior and posterior tilting of the pelvis in the erect standing postion.
Steel pallet racking industry has globally used from the industrial revolution and has deeply evolved from hot-rolled profile into cold-formed profile to raise the optimization in engineering field. Nowadays, some studies regarding cold-formed steel profile have been performed, but fewer studies in terms of cold-formed pallet racking specifically in connection due to the semi-rigid behavior by lug-hooked into the upright have been conducted. The objective of this study is to review the related literature on steel storage racking connection behavior.
Journal of the Korean Society for Precision Engineering
/
v.28
no.1
/
pp.115-122
/
2011
Recently, we have proposed a hypothesis that spinal structures have a stress sensor driving feedback mechanism, In the human spine, spinal structure could react to modify muscular action in such a way so as to equalize stress at the disc, therefore reduce the risk of injury, In this analysis, abdominal muscle and abdominal pressure, which were not included in the previous study, were added to identify those effects in spine stability during upright stance posture for the case where the intervertebral disc plays the role of mechanoreceptor, The musculoskeletal FE model was consisted with detailed whole lumbar spine, pelvis, sacrum, coccyx and simplified trunk model. Muscle architecture with 46 local muscles containing paraspinal muscle and 6 rectus abdominal muscles were assigned according to the acting directions. The magnitude of 4kPa was considered for abdominal pressure. Minimization of the nucleus pressure deviation and annulus fiber average tension stress deviation was chosen for cost function. Developed model provide nice coincidence with in-vivo measurement (nucleus pressure). Analysis was conducted according to existence of co-activation of abdominal muscle and abdominal pressure. Antagonistic activity of abdominal muscle produced stability of spinal column with relatively small amount of total muscle force. In contrast to the abdominal muscle, effect of abdominal pressure was not clear that was partly depending on the assumption of constant abdominal pressure.
Journal of the Korean Society for Precision Engineering
/
v.27
no.2
/
pp.130-136
/
2010
For stability analysis of the lumbar spine, the hypothesis presented is that the disc has stress sensors driving feedback mechanism, which could react to the imposed loads by adjusting the contraction of the muscles. Fusion in the motion segment of the lumbar spinal column is believed to alter the stability of the spinal column. To identify this effect finite element (FE) models combined with optimization technique was applied and quantify the role of each muscle and reaction forces in the spinal column with respect to the fusion level. The musculoskeletal FE model was consisted with detailed whole lumbar spine, pelvis, sacrum, coccyx and simplified trunk model. Vertebral body and pelvis were modeled as a rigid body and the rib cage was constructed with rigid truss element for the computational efficiency. Spinal fusion model was applied to L3-L4, L4-L5, L5-S1 (single level) and L3-L5 (two levels) segments. Muscle architecture with 46 local muscles was used as acting directions. Minimization of the nucleus pressure deviation and annulus fiber average axial stress deviation was selected for cost function. As a result, spinal fusion produced reaction changes at each motion segment as well as contribution of each muscle. Longissimus thoracis and psoas major muscle showed dramatic changes for the cases of L5-S1 and L3-L5 level fusion. Muscle force change at each muscle also generated relatively high nucleus pressure not only at the adjacent level but at another level, which can explain disc degeneration pattern observed in clinical study.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.