• Title/Summary/Keyword: upper to zero

Search Result 160, Processing Time 0.026 seconds

Stable Walking for an Inverted Pendulum Type Biped Robot (도립 진자형 이족보행로봇을 위한 안정보행)

  • Kang, Chan-Su;Noh, Kyung-Kon;Kim, Jin-Geol
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.456-459
    • /
    • 2003
  • This paper deal with the biped walking stability by inverted pendulum type balancing joints. This model is hard to interpretation for the nonlinearity caused by upper direction movement then conventional model which have roll and prismatic joints. We can interpret this model by a linear approximation or interpolation method. This paper use a linear approximation method that can decide a movement of upper direction. Inverted pendulum type balancing joints have a advantage of less movement for keep stability and similar with human than conventional model and this model can be used for humanoid robot. We can see a stability of biped by ZMP(Zero Moment Point). Genetic algorithm is used for trajectory planning that is important for stable walking of biped.

  • PDF

A Study of Analytical Sensitivity on TDM Test Kit in Clinical Chemistry (약물검사 키트의 분석 민감도에 대한 연구)

  • Chang, Sang Wu;Kim, Nam Yong;Lee, Hee Gyung;Kim, Hyun Jung;Lee, Yun Jung;Jin, Ok Bae;Kim, Mi Gyung
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.36 no.2
    • /
    • pp.127-130
    • /
    • 2004
  • Analytical sensitivity on TDM test is the lowest concentration that can be distinguished from background noise. The aim of study was to evaluate analytical sensitivity that is also referred to as the lower limit of detection(LLD) about difference between zero calibrator and isotonic saline sample. We tested for 10 days with zero calibrators and 0.85% saline samples while running trilevel control samples under control. Raw data divided by two groups calculated mean and standard deviation from two sample populations and analytical sensitivity by ${\bar{X}}+2SD$. In comparison with isotonic saline samples and zero calibrators, there were significant differences in phenytoin, phenobarbital and vancomycin, etc. Especially analytical sensitivity on phenytoin is at the same level as the upper limit of analytical measurement range with $40{\mu}g/mL$. We think the cause of this is matrix interference. In conclusion, we were sure that standard protocol for analytical sensitivity as lower limit of analytical measurement range on TDM test must be measured with zero standard rather than an isotonic saline sample and type 1 reagent DW for reducing matrix effects within interactions between different materials in a mixture.

  • PDF

A Study of Stable Walking Analysis for Humanoid Robot (휴머노이드 로봇의 안정 보행 동작 해석에 관한 연구)

  • Sung, Yu-Kyoung;Kong, Jung-Shik;Lee, Bo-Hee;Kim, Jin-Geol;Huh, Uk-Youl
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.404-407
    • /
    • 2003
  • In this paper, we have designed the humanoid robot's leg parts with 12 D.O.F. This robot uses ankle's joints to confirm stability of walking performance. It is less movable to use ankle's joints than to do upper body's balancing joints like IWR-III, which needs three parts of via points, support leg, swing leg and balancing joints. Instead, the proposed humanoid robot needs support leg and swing leg via points. ZMP(Zero Moment Point) is utilized to guarantee the stability of robot's walking. The humanoid robot uses the ankle's joints to compensate for IWR-III's balancing joints movement. Actually we concern about a motor performance when making a real humanoid robot. So a simulator is employed to know each joint torque of humanoid robot. This simulator needs D-H(Denavit-Hartenberg) parameters, robot's mass property and two parts of via points. The simulation results are robot's walking trajectories and each motor torque. Using the walking trajectories, we can see the robot's walking scene with 3D simulator. Before we develop the humanoid robot, simulation of the humanoid robot's walking performance is very helpful. And the torque data will be used to make humanoid's joint module.

  • PDF

Real-time malfunction detection of plasma etching process using EPD signal traces (EPD 신호궤적을 이용한 플라즈마 식각공정의 실시간 이상검출)

  • Cha, Sang-Yeob;Yi, Seok-Ju;Koh, Taek-Beom;Woo, Kwang-Bang
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.4 no.2
    • /
    • pp.246-255
    • /
    • 1998
  • This paper presents a novel method for real-time malfunction detection of plasma etching process using EPD signal traces. First, many reference EPD signal traces are collected using monochromator and data acquisition system in normal etching processes. Critical points are defined by applying differentiation and zero-crossing method to the collected reference signal traces. Critical parameters such as intensity, slope, time, peak, overshoot, etc., determined by critical points, and frame attributes transformed signal-to symbol of reference signal traces are saved. Also, UCL(Upper Control Limit) and LCL(Lower Control Limit) are obtained by mean and standard deviation of critical parameters. Then, test EPD signal traces are collected in the actual processes, and frame attributes and critical parameters are obtained using the above mentioned method. Process malfunctions are detected in real-time by applying SPC(Statistical Process Control) method to critical parameters. the Real-time malfunction detection method presented in this paper was applied to actual processes and the results indicated that it was proved to be able to supplement disadvantages of existing quality control check inspecting or testing random-selected devices and detect process malfunctions correctly in real-time.

  • PDF

Study on a Simulator for Generating Side Walking Path of the Biped Walking Robot (이족보행로봇의 횡보행 경로생성을 위한 시뮬레이터 연구)

  • Choi, Hyeung-Sik;Jeon, Chang-Hoon;Kang, Jin-Il
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.8
    • /
    • pp.1285-1295
    • /
    • 2008
  • A research on a simulator for a side walking path of a 16 degree-of-freedom (d.o.f) biped walking robot(BWR) which is composed of 4 d.o.f upper-part body and 12 d.o.f lower-part of the body is presented. For generation of stable side walking motion, the kinematics, dynamics and the zero moment of point(ZMP) of the BWR were analyzed analytically and included in the simulator. To operate the motion simulator for stable side walking of the BWR, a graphic user interface program was developed which needs inputs for the side distance between legs, base joint angle, walking type, and walking velocity. The simulator was developed to generate joint angle data of legs for side walking, and the data are transmitted to the BWR for stable side walking. In the simulator, a new path function for smooth walking motion was proposed and applied to the simulator and actual motion of a BWR. Also for actual side walking, an algorithm for estimating backlashes of the actuating joint motors was proposed and included in the simulator. To validate the performance of the proposed motion simulator, the simulator was operated and its side walking data of the simulator were generated for a period of side walking.

Microstructure and Mechanical Property in Thickness Direction of a Deoxidized Low-Phosphorous Copper Sheet Processed by Two-Pass Differential Speed Rolling (2-pass 이주속압연된 인탈산동판재의 두께방향으로의 미세조직 및 기계적 특성)

  • Lee, Seong-Hee;Jang, Jun-Hyuk;Utsunomiya, Hiroshi
    • Korean Journal of Materials Research
    • /
    • v.23 no.7
    • /
    • pp.392-398
    • /
    • 2013
  • A two-pass differential speed rolling(DSR) was applied to a deoxidized low-phosphorous copper alloy sheet in order to form a homogeneous microstructure. Copper alloy with a thickness of 3 mm was rolled to 75 % reduction by two-pass rolling at $150^{\circ}C$ without lubrication at a differential speed ratio of 2.0:1. In order to introduce uniform shear strain into the copper alloy sheet, the second rolling was performed after turning the sample by $180^{\circ}$ on the transverse direction axis. Conventional rolling(CR), in which the rotating speeds of the upper roll and lower roll are identical to each other, was also performed by two-pass rolling under a total rolling reduction of 75 %, for comparison. The shear strain introduced by the conventional rolling showed positive values at positions of the upper roll side and negative values at positions of the lower roll side. However, samples processed by the DSR showed zero or positive values at all positions. {100}//ND texture was primarily developed near the surface and center of thickness for the CR, while {110}//ND texture was primarily developed for the DSR. The difference in misorientation distribution of grain boundary between the upper roll side surface and center regions was very small in the CR, while it was large in the DSR. The grain size was smallest in the upper roll side region for both the CR and the DSR. The hardness showed homogeneous distribution in the thickness direction in both CR and DSR. The average hardness was larger in CR than in DSR.

Performance Assessment of Elementary 'School Children's Measuring Skills (초등학생들의 측정 수행 능력 평가)

  • Jung, Gui-Hyang;Kim, Beom-Ki
    • Journal of The Korean Association For Science Education
    • /
    • v.17 no.2
    • /
    • pp.127-137
    • /
    • 1997
  • The purpose of this study was to assess elementary student's ability of measuring length, area, and volume and reading metric scales. The findings of this study were as follows. All students were successful in measuring without scale, regardless of grades. But they were less successful in measuring the task using standard and nonstandard scales. Especially, in measuring area, lower grade students were not able to perform the task using nonstandard instruments, but higher grade students were able to perform the task. Measuring area using grade paper was least successful for sixth graders. In measuring volume, students under fifth grade read the upper scale when using graduated cylinder. In measuring by direct comparison, students were more successful in measuring length than in measuring area and volume using given material. The use of given nonstandard material was successful for 4th, 5th, and 6th grade students. In measuring using metric scale, lower grade students did not pay attention to the zero of the scale, but just read the end point. Higher grade students considered both zero and end points.

  • PDF

Fabrication of YBCO/STO/YBCO Multilayer (YBCO/STO/YBCO 다층박막 제작)

  • Ha, Dong-Han;Hwang, Tae-Jong;Lim, Hae-Yong;Kim, Jin-Cheol;Kim, Dong-Ho;Park, Jong-Cheol;Park, Yong-Ki
    • 한국초전도학회:학술대회논문집
    • /
    • v.9
    • /
    • pp.34-37
    • /
    • 1999
  • We have fabricated YBCO/STO/YBCO multilayer by the pulsed laser deposition method varing the deposition condition of insulating STO layer. Superconducting properties of both YBCO layers are sensitively affected by the deposition condition of STO layer. We obtained the upper YBCO layer of T$_{c(zero)}\;{\sim}\;$90 K with a good reproducibility, however, T$_{c(zero)}$ of lower YBCO layer was decreased to about 80 K maybe due to the oxygen loss during the deposition of STO layer. Superconducting properties of both YBCO layers at every fabrication step were measured in order to study the reason for the deterioration of superconducting properties.

  • PDF

A Truncated Booth Multiplier Architecture for Low Power Design (저전력 설계를 위한 전달된 Booth 곱셈기 구조)

  • Lee, Kwang-Hyun;Park, Chong-Suck
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.9
    • /
    • pp.55-65
    • /
    • 2000
  • In this paper, we propose a hardware reduced multiplier for DSP applications. In many DSP applications, all of multiplier products were not used, but only upper bits of product were used. Kidambi proposed truncated unsigned multiplier for this idea. in this paper, we adopt this scheme to Booth multiplier which can be used real DSP systems. Also, zero input guarantees zero output that was not provided in previous paper. In addition, we propose bit extension scheme to reduce truncation error more and more. And, we adopted this multiplier to FIR filters for more efficient design.

  • PDF

Design of Bandpass Filter with a Single Dual-Mode Resonator (하나의 이중 모드 공진기를 이용한 대역 통과 필터 설계)

  • An, Jae-Min;Lim, Yeong-Seog
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.12
    • /
    • pp.1432-1437
    • /
    • 2010
  • This paper proposes a new design method of bandpass filter with single dual-mode resonator. In the proposed method, a coupling coefficient between two resonators was obtained by considering a dual-mode resonator as two single resonators. Based on the obtained coupling coefficient, two resonant frequencies of dual-mode resonator were calculated and then arranged according to a transmission zero's location of required filter. To verify the proposed theory, two WLAN bandpass filters which have a transmission zero to a lower and an upper stopband repectively were designed and implemented.