• Title/Summary/Keyword: unit work

Search Result 1,504, Processing Time 0.025 seconds

Pneumatic circuit design and Performance test of Air balancer (에어밸런서 공압 회로의 설계 및 성능 실험)

  • Kim, D.S.;Bae, S.K.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.3 no.3
    • /
    • pp.20-24
    • /
    • 2006
  • Air balancer is a conveyance cargo-handling machine, used in assembly and process lines of car and machining industries. This can lift up an object, the weight of which is from 5 to 200 kg, and moves it to a position. As industrial technologies evolve, it is required to move an object and fit it into a specified position with greater accuracy, rather than performing simple tasks such as lifting objects up and down as conventional ones do. There is also a demand to handle an object with one hand, rather than with two hands,. Through designs of manifold unit for an air balancer function, pilot regulator unit to keep pressure constant, hand unit for an accurate load perception function, and air balancer circuit, this study enables everybody to work it with ease and convenience. Experiments and comparisons were conducted for the performance evaluation of the circuit.

  • PDF

A Validation Study of Nursing Diagnosis in Emergency Care Unit (응급간호단위에 적용되는 간호진단의 타당도 연구)

  • Choi Kyung-Won;Oh Hae-Gyeong
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.10 no.2
    • /
    • pp.145-153
    • /
    • 2003
  • Purpose: Related factors for 24 nursing diagnoses frequently used in the emergency care unit were validated in this study. Method: A convenience sample of 65 registered nurses who had worked for 2 years or more in emergency care units and received instruction on nursing diagnosis was used for the study. The classification of nursing diagnoses was based on NANDA (1996) and validation, on Fehring (1987)'s DCV model. Result: Differences were found between emergency and general care units for related factors for nursing diagnosis. Newly reported related factors were not found for emergency care units. Conclusion: It is helpful for nurses who work in emergency care to be able to apply the nursing diagnosis validated in this study. These findings can be used as the database to provide a nursing diagnosis system appropriate to improving the emergency nursing practice.

  • PDF

An Experimental Study on the Characteristics of Compressive Strength of Antiwashout Underwater Concrete with Curing Water (양생수에 따른 수중불분리콘크리트의 압축강도특성에 관한 실험적 연구)

  • 윤재범;고창섭;김명식;장희석
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.135-138
    • /
    • 1999
  • The objective of this study is to investigate the compressive strength property of antiwashout underwater concrete with curing water through experimental researches. Type of casting and curing water(fresh water, sea water) are used as main experimental parameter, additionally a few variables affecting compressive strength property are used ; water-cement ratio (45%, 48%, 50%, 52%, 55%), and unit weight of admixtures (antiwashout underwater agent ; 0.6%, 0.8%, 1.0%, 1.2%, 1.4% of unit weight of water, superplasticizer ; 0.5%, 1.0%, 1.5%, 2.0%, 2.5% of unit weight of cement)) Compressive strength level of antiwashout underwater concrete which was cast and cured in fresh water is higher than other one. Consequently, incremental modulus has to increase when the antiwashout underwater concrete is made use of underwater work from ocean.

  • PDF

Development of Monitoring and Diagnosis System for Linear Motion Unit (직선 운동 유닛의 감시 및 진단 시스템 개발)

  • Huang, Jian;Kim, Hwa-Young;Ahn, Jung-Hwan
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.635-636
    • /
    • 2012
  • In the present work, investigations by high frequency resonance technique for diagnosis of defect frequencies of linear motion unit are reported. Raw vibration signature of the moving parts at different speeds of operation has been demodulated. Envelope detected spectrum is analyzed to evaluate various defect frequencies and their energy levels. Experimentally evaluated frequencies are compared with theoretically determined defect frequencies. These frequency values and their energy levels are used to monitor intrinsic condition of linear motion unit as well as to establish severity of existing/developed defects on the LM guide and inside the LM block. Relative comparisons of linear motion units of the same type are made at various operating speeds under identical conditions of operation on the basis of identified defect frequencies and severity of defects.

  • PDF

Applying Problem-Based Language Learning in an Online Class: Designing a PBLL Unit

  • Abdullah, Mardziah Hayati;Chong, Larry Dwan
    • English Language & Literature Teaching
    • /
    • v.9 no.spc
    • /
    • pp.1-17
    • /
    • 2003
  • This paper aims to propose that Problem-Based Learning (PBL) is a method that can help meet the conditions in language learning and instruction. PBL was first used in medical education, where learners engaged in problem-solving activities that reflect the demands of real-life professional practice, thus promoting critical thinking in the content domain. The paper proposes that by applying PBL in language learning and creating situations in which learners work collaboratively on problems, the learners benefit in two respects: (i) they have the opportunity to practise the kind of thinking skills and problem-solving strategies needed in real life, and (ii) they engage in purposeful language activity with others through discussion and negotiation. The paper first provides a theoretical rationale far the use of PBL in language learning and suggests attendant changes in the role of a language instructor in a PBL context. The paper then presents an outline of the stages and components needed in designing an online PBL Unit far use in an undergraduate language class.

  • PDF

Hybrid Artificial Immune System Approach for Profit Based Unit Commitment Problem

  • Lakshmi, K.;Vasantharathna, S.
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.5
    • /
    • pp.959-968
    • /
    • 2013
  • This paper presents a new approach with artificial immune system algorithm to solve the profit based unit commitment problem. The objective of this work is to find the optimal generation scheduling and to maximize the profit of generation companies (Gencos) when subjected to various constraints such as power balance, spinning reserve, minimum up/down time and ramp rate limits. The proposed hybrid method is developed through adaptive search which is inspired from artificial immune system and genetic algorithm to carry out profit maximization of generation companies. The effectiveness of the proposed approach has been tested for different Gencos consists of 3, 10 and 36 generating units and the results are compared with the existing methods.

Validity of nursing diagnosis : Fluid volume deficit (체액량 부족(Fluid volume deficit) ; 간호진단의 타당도 조사 연구)

  • Byun Young-Soon;Kim Sook-Young
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.1 no.2
    • /
    • pp.207-218
    • /
    • 1994
  • A validation of the nursing diagnosis 'fluid volume deficit' was completed by using the diagnostic content validity method. Articles pertaining to fluid volume depletion were reviewed to identify the signs and symptoms used to describe the nursing diagnosis. The topics addressed in the articles included hypovolemic shock, hemorrhage, trauma, fluid balance, hydration, burn injury, thirst, dehydration. A validation instruments was constructed of 52 signs and symptoms. A validation tool was examined by expert nurses group who work on intensive care unit, kidney transplantation unit, internal medicine and general surgery unit. The study sample rated the signs and symptoms on a scale from one to five, evaluating their relevance to this diagnosis. Of the 52 signs and symptoms on the validation tool, 10 were categorized as critical indicators and 34 were categorized as defining characteristics.

  • PDF

The Simulation of Cutting force Estimate Model at Micro-Stage for Ultra Precision Cutting Machine of Nano Part (나노부품 초정밀가공기용 마이크로스테이지의 절삭력 예측모델 시뮬레이션)

  • 김재열;심재기;곽이구;안재신;한재호;노기웅
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.04a
    • /
    • pp.173-178
    • /
    • 2003
  • Recently, according to the development of mechatronics industry that was composed of NT, ST, IT, RT and etc, the 1 necessity of nano-parts was increased. Because of the necessity, this research was started for improving work precision of the parts as fixing UPCU( Ultra Precision Cutting Unit)on lathe. So, in this research we executed the modeling of UPCU (Ultra Precision Cutting Unit) by the application of PZT, the relationship between the displacement of tool in UPCU and the cutting force of it has been in take a triangular position in the case of plane cutting. The modeling of system that is containing the fine displacement was performed. Also, we found like to find the optimal cutting condition through the simulation of relationship between the displacement and the cutting force.

  • PDF

Experience of Workplace Violence among Intensive Care Unit Nurses (중환자실 간호사의 폭력경험)

  • Hwang, Yoon Young;Park, Youngrye;Park, Sunghee
    • Korean Journal of Adult Nursing
    • /
    • v.27 no.5
    • /
    • pp.548-558
    • /
    • 2015
  • Purpose: The purpose of this study was to explore the experience of workplace violence among intensive care unit nurses. Methods: The participants of this research were twelve registered nurses who work in the intensive care units (ICU) at the hospitals in Seoul and Gyunggido. Data were collected by individual in-depth interviews and analyzed using the phenomenological methodology by Colaizzi. Results: From significant statements, five theme clusters emerged as follow; 1) vulnerable young women to violence, 2) my own reflection was bruised and exhausted, 3) a hopeless everyday, 4) seeking a solution in relation, 5) establishing one's status as a professional nurse. Conclusion: This study provides a profound understanding on the experiences of workplace violence among ICU nurses. The hospitals are suggested to provide a safe environment by developing programs and policies to prevent and cope with hospital workplace violence for ICU nurses.

A Study on the Structure of Time Unit and SIMO of MODAPTS and Development of High Task MODAPTS(HITMAT) (MODAPTS의 시간단위 및 동시동작의 구조와 High Task MODAPTS(HITMAP)의 개발에 관한 연구)

  • Park, Seong-Hak
    • Journal of Korean Society for Quality Management
    • /
    • v.20 no.2
    • /
    • pp.137-142
    • /
    • 1992
  • MODAPTS has been widely used for establishing the standard time of manual works because of easy application of the system. However this system was developed based on MTM, winch was one of the low task standard. Also in this system, it usually becomes a cause of error in accuracy that all the simultaneous motions(SIMO) should be analyzed in the sequent motions of two hands. In order to improve the weak points of MODAPTS, the structure of time unit and SIMO of MODAPTS was researched, and HITMAP was developed on the basis of Work Factor System which was one of the high task standard. HITMAP is composed of 26 standard elements and it's time unit is MD(1MD=0.1 second) and MGSRMPS is the motion pattern of HITMAP. In this study HITMAP shows more than 95% of accuracy to WF. Therefor, it is expected that HITMAP can be used for the improvement of productivity and incentive systems.

  • PDF