• Title/Summary/Keyword: unit load

Search Result 1,511, Processing Time 0.026 seconds

The optimum specifications and design of distributive transformers (배전용 변압기의 합리적인 사양과 그 설계법)

  • 이승원
    • 전기의세계
    • /
    • v.14 no.4
    • /
    • pp.8-17
    • /
    • 1965
  • Firstly, this study has analyzed the following factors affecting the optimum specifications and design of distributive transformers: 1. Facilities installation cost per unit power output. 2. Facilities operating & maintenance cost per unit power output. 3. Production cost per unit power output. 4. Load factor. 5. Loss factor. Secondly, it has clarified the relations between the following factors and the specifications and design of distributive transformers; 1. No-load loss., 2. Load loss., 3. Voltage regulation., 4. Exciting current. Finally, it has determined the method of the most economic design for the transformers using the above factors and relations, and, for optimum the illustrative purpose, suggested their optimum specifications, way of evaluation, and merits by means of typical example.

  • PDF

Runoff of Pollutant Loads from Paddy Field Area in a Dry Year (갈수년 광역논에서의 오염부하의 유출 특성)

  • Oh, Seung-Young;Kim, Jin-Soo
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.385-388
    • /
    • 2002
  • We investigated net outflow load and unit load of pollutants from a paddy fields area in dry year 2001. Amount of irrigation water in 2001 was about 61-63% of that in previous years 1999 and 2000 due to drought. The net outflow load and unit load of pollutants in 2001 were negative, showing that paddy fields acts as sink of pollutants due to function of water quality purification. The relationship between unit load of pollutants and net surface outflow (= surface outflow - irrigation water) showed positive correlation. The results showed that abatement of surface outflow by appropriate water management contribute to reduce surface outflow load from paddy fields.

  • PDF

A Study on Wired LogiC for Type Unit for PLC Output Driving (PLC 출력 구동을 위한 Wired Logic for Type Unit에 관한 연구)

  • 위성동;김태성
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.36T no.1
    • /
    • pp.51-57
    • /
    • 1999
  • This thesis is written about the Wired Logic Type Unit in developing equipment that the load is driven, that the interface unit connect with 1 Scan time to PO30 of operated PLC output contact with that a sensing signal of Temperature Sensor RSD Pt $100\Omega$ let generate the relay output of temperature controller and input the PLC. The PLC Test Kit in country that the PLC to be programmed at the PLC education place is able to drive the load, is done to do a education of PLC on status that interface process between PLC and load are disregarded. As Developing Kit for supplement this point, when the relay output of temperature controller to use Pt 100 of temperature sensor as mentioned on the former among every kinds of sensor feed back to the input of the PLC, as the equipment to act with real time system that the output contact of PLC operated to insert the WLTIJ among PC, PLC and the load, it can understand and see very easy the main principle of PLC use. The structure of WLTU to be a interface unit of load separated as to the point of contact and noncontact, sensor, indicating lamp and A contact and B contact that is belong to driving part, and a motor is belong to loading part.

  • PDF

A Study on the Water Quality Changes of TMDL Unit Watershed in Guem River Basin Using a Nonparametric Trend Analysis (비모수 경향분석법 적용을 통한 금강수계 총량관리 단위유역의 수질변화 연구)

  • Kim, Eunjung;Kim, Yongseok;Rhew, Doughee;Ryu, Jichul;Park, Baekyung
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.2
    • /
    • pp.148-158
    • /
    • 2014
  • In order to assess the effect of TMDLs management and improve that in the future, it is necessary to analyze long-term changes in water quality during management period. Therefore, long term trend analysis of BOD was performed on thirty monitoring stations in Geum River TMDL unit watersheds. Nonparametric trend analysis method was used for analysis as the water quality data are generally not in normal distribution. The monthly median values of BOD during 2004~2010 were analyzed by Seasonal Mann-Kendall test and LOWESS(LOcally WEighted Scatter plot Smoother). And the effect of Total Maximum Daily Loads(TMDLs) management on water quality changes at each unit watershed was analyzed with the result of trend analysis. The Seasonal Mann-Kendall test results showed that BOD concentrations had the downward trend at 10 unit watersheds, upward trend at 4 unit watersheds and no significant trend at 16 unit watersheds. And the LOWESS analysis showed that BOD concentration began to decrease after mid-2009 at almost all of unit watersheds having no trend in implementation plan watershed. It was estimated that TMDLs improved water quality in Geum River water system and the improvement of water quality was made mainly in implementation plan unit watershed and tributaries.

Characterization on the Pollution Discharge Load at the Unit Watershed for the Management of Total Maximum Daily Loads - in Guem River Basin (수질오염총량관리 단위유역별 오염물질 배출부하량 특성분석 - 금강수계를 대상으로)

  • Park, Jun Dae;Choi, Ok Youn;Oh, Seung Young
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.6
    • /
    • pp.786-795
    • /
    • 2012
  • Water quality management should be focused on the pollution concentrated area so that the improvement of water quality can be achieved effectively for the management of Total Maximum Daily Loads (TMDLs). It is necessary to consider discharge characteristics in the TMDL plan. This study analysed discharge characteristics such as pollution generation and discharge load density, and reduction potential by each unit watershed, and categorized the unit watershed into four groups according to its discharge load characteristics. This analysis can be used as helpful information for the prioritization of pollution reduction area and selection of pollution reduction measures in the development of TMDL plans.

A Study on Driving Motor Performance Comparison for Load Efficiency Improvement of a Bicycle Locker System (자전거 거치대 잠금장치의 부하시 효율개선을 위한 구동모터성능비교에 관한 연구)

  • Han, Ki-Soo;Won, Sung-Hong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.4
    • /
    • pp.175-180
    • /
    • 2013
  • This paper presents the design and implementation of a Bicycle Locker System. Generally DC motor has been used to control a Bicycle Locker System, but DC motor system requires frequent maintenances and its power efficiency is comparatively poor especially under heavy load conditions. In order to improve this difficulties, this paper adopts BLDC motor for a Bicycle Locker System and its motor controller is developed. The performances of locker units are compared between DC motor unit and BLDC motor unit. The motor power consumptions between two motors are discussed. Test results verify that power efficiency of the suggested BLDC drive unit is considerably improved compared to the DC drive unit with load condition.

A Situations and Improvements on the Rail Freight System (철도화물수송체계의 현황과 개선방안)

  • 이용상
    • Journal of the Korean Society for Railway
    • /
    • v.7 no.1
    • /
    • pp.37-48
    • /
    • 2004
  • In this paper, I explain the situations and problems which are focused on the rail freight system. We have a many problems, which have been showed the long freight logistics time, and inadequate fare system. And rail freight system does not have a efficient marketing system, and unit load system. Therefore rail freight has been decreased modal share, which is estimated from 9.65% in 1995 to 6.25% in 2001(ton base). Recently, EU nations and America rail freight system reveals a good outcome, which keeps the balance in the black. The main factors which go into the black, is the enlargement the investment in rail freight and efficient management focusing on the unit load system, fare system, and personnel management. I suggest the several improvement ways, which will be helpful to advance the rail freight system. Fistly, I suggest the speed up the freight rail and efficient fare system. Secondly, I propose the unit load system and the regulation the truck focusing on curtailment of the social cost. Lastly, I make an overture of establishment the comprehensive logistics system.

Stochastic Analysis of the Uncertain Hourly Load Demand Applying to Unit Commitment Problem (발전기 기동정지 계획에 적용되는 불확실한 부하곡선에 대한 통계적 분석)

  • Jung, Choon-Sik;Park, Jeong-Do;Kook, Hyun-Jong;Moon, Young-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.337-340
    • /
    • 2000
  • In this paper, the effects of the uncertain hourly load demand are stochastically analyzed especially by the consideration of the average over generation of the Unit Commitment(UC) results. In order to minimize the effects of the actual load profile change, a new UC algorithm is proposed. The proposed algorithm calculates the UC results with the lower load level than the one generated by the conventional load forecast. In case of the worse load forecast, the deviation of the conventional UC solution can be overcome with the lower load level and the more hourly reserve requirements. The proposed method is tested with sample systems, which shows that the proposed method can be used as the basic guideline for selecting the potimal load forecast applying to UC problem.

  • PDF

A study on the estimation of unit load generation and discharge from livestock resources of piggery (돼지 축분자원화물의 발생 및 배출부하 원단위 산정에 관한 연구)

  • Han, Gee-Bong;Kang, Young-Hee;Yoon, Ji-Hyun;Rim, Jay-Myoung;Won, Chul-Hee;Choi, Seung-Chul
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.14 no.3
    • /
    • pp.91-100
    • /
    • 2006
  • In this study, the characterization of unit load generation and discharge from various type stall of piggery was conducted by investigation and analysis of contaminants loading from piggery urine, manure and wastewater. The results are summarized as follows: The unit load generation of filth increases as piggery grow older, but there was not large enough difference among those values of unit load evaluated for various stall types if mean values of each type of stall are considered. The generation amounts of manure and urine were total 4.57kg/head/d of 1.49kg manure/head/d and 3.08kg urine/head/d with consideration of 3 seasons and live weight. The finalized mean unit load generation of filth were estimated at BOD 199.5g/head/d, $COD_{cr}\;413.5g/head/d$, T-N 27.8g/head/d, T-P 5.3g/head/d with consideration of seasons and the type of stalls. The wastewater unit loads discharged from cement type stall were estimated at BOD 31.3g/head/d, $COD_{cr}\;95.6g/head/d$, T-N 8.9g/head/d, T-P가 3.1g/head/d. The sum of manure unit load generation considered with manure collection ratio(80%, 90%) and wastewater unit load was almost similar when compared to the unit load discharged from slurry type stall even though more or less difference were appeared according to each contaminants and parameters.

  • PDF

Application of Margin of Safety Considering Regional Characteristics for the Management of Total Maximum Daily Loads (지역특성을 고려한 수질오염총량관리 안전부하량 적용)

  • Park, Jun Dae;Oh, Seung Young;Kim, Yong Seok
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.3
    • /
    • pp.351-360
    • /
    • 2014
  • The allocation of margin of safety (MOS) at a uniform rate to all areas of the unit watershed makes it very difficult to keep the load allotment stable in the area for lack of reduction measures like forest land. This study developed an equation to calculate margin of safety differentially according to the regional characteristics. The equation was formulated on the basis of the regional characteristic factors such as a load contribution factor for land use type and a site conversion factor for the unit watershed. The load contribution factor represents a contribution of loads from a particular land use. The site conversion factor was derived from the site conversion ratio of a unit watershed. Margin of safety for the non-point pollution load in the land use sector decreased by 20~25% in three river basins. The margin of safety in the unit watersheds with low site occupation ratios decreased in high rate, while in the unit watersheds with large urban area decreased in low rate. With the application of the differential margin of safety considering regional characteristics, not only the reduction of pollution loads can become lighter but also it can be easier to develop plans for Total Maximum Daily Loads (TMDLs) even where the reduction measures are not available.