• Title/Summary/Keyword: uniformity test

Search Result 365, Processing Time 0.038 seconds

Optimization and Improvements of Field Uniformity in a Reverberation Chamber with Schroeder Diffusers (Schroeder 확산기를 이용한 전자파 잔향실내의 필드 균일도 향상 및 최적화에 관한 연구)

  • Kim, Jung-Hoon;Rhee, Joong-Geun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.4 s.119
    • /
    • pp.372-378
    • /
    • 2007
  • This paper presents an improvement of field uniformity in a reverberation chamber with QRDs(Quadratic Residue Diffuser) and also shows the optimal dimension of the QRDs. The QRD is designed for $1{\sim}3\;GHz$ frequency band and the FDTD(finite-Difference Time-Domain) method is used to analyze the field characteristics. At 2 GHz, the standard deviation of test volume in the reverberation chamber is the smallest when the QRD has $30{\sim}60\;%$ coverage of one side of the reverberation chamber and the field uniformity is worsened when the coverage of the QRD is either below 20 % or above 70 % of the area of the side wall. Particularly, the standard deviation of test volume in the reverberation chamber with 30 % coverage of QRD is improved by 1.53 dB compared to that of the reference chamber with no QRDs.

Improved Field Uniformity Characteristics in a Reverberation Chamber with a CRD (CRD를 이용한 전자파 잔향실 내 전기장 균일도 향상)

  • Son, Yong-Ho;Rhee, Joong-Geun;Kim, Jung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.12
    • /
    • pp.79-84
    • /
    • 2007
  • This paper presents an improved field uniformity in a reverberation chamber, that can be alternatively used for the analysis and the measurement of electromagnetic interference and immunity, with a designed CRD(Cubical Residue Diffuser) that have various dimensions. The Schroeder type CRD is designed for $1\sim3$ GHz band and the FDTD(Finite Difference Time Domain) method is used to analyze the field characteristics. At 2 GHz, the standard deviation of test volume in the reverberation chamber is the smallest and has a good field distribution with a CRD of $40\sim80%$ dimension of one side of the reverberation chamber. The Electric field uniformity gets worse when the dimension of a CRD is either below 40 % or above 80 % of the side wall. The result shows that the standard deviation of the test volume in the reverberation chamber with a CRD of 44 % dimension is improved by 1 dB compared with that of the reverberation chamber with a CRD of 100 % dimension.

Performance Evaluation of a Pinhole Collimator According to the Aperture Diameter (핀홀 콜리메이터 초점의 직경 크기 별 성능비교 및 평가)

  • Lee, Kwang Hun;An, Byung Ho;Kim, Soo Young;Choi, Sung Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.104-109
    • /
    • 2014
  • Purpose: Conventional pinhole scintigraphy offers a high resolution and generally use for thyroid scan or bone scintigraphy. the aim of this study is to evaluate performance of each aperture according to the diameter size. Materials and Methods: In this study 2 mm, 4 mm, 6 mm, 8 mm diameter pinhole collimators were mounted on Siemens E.CAM systems. In order to evaluate performance evaluation of each aperture, we acquired projection image by using SPECT for evaluating FWHM, resolution test and static image for evaluating thyroid phantom test. Results: As a result of FWHM showed 2.2 mm FWHM, 3.2 mm FWHM, 5.4 mm FWHM, 7.5 mm FWHM per each aperture in the resolution test. SNR, uniformity, contrast were acquired result from thyroid phantom test comparing general image and delayed image. as a result of SNR showed 6.55, 8.47, 6.2, 5.23 in case of general image and 5.25, 5.01, 5.38, 5.82 in case of delayed image per each aperture. as a result of uniformity showed 0.152, 0.118, 0.161, 0.19 in case of general image and 0.19, 0.199, 0.185, 0.171 in case of delayed image per each aperture. as a result of contrast showed 1.31, 1.19, 1.15, 1.01 in case of general image and 1.09, 1.08, 1.04, 1 in case of delayed image per each aperture. Conclusion: Resolution and sensitivity were heavily influenced by aperture size. and also we found advantage of delayed image as a result of thyroid phantom test.

  • PDF

Characteristics of flow field of nose-only exposure chamber for inhalation toxicity evaluation (흡입독성평가를 위한 비부노출 챔버의 유동흐름 특성)

  • Noh, Hakjae;Bong, Choonkeun;Bong, Hakyung;Kim, Yonggu;Cho, Myunghaing;Kim, Sanghwa;Kim, Daesung
    • Particle and aerosol research
    • /
    • v.12 no.1
    • /
    • pp.1-9
    • /
    • 2016
  • In this work, we evaluated the characteristics of flow field and uniformity of the nose-only exposure chambers for the inhalation toxicity test. Computational fluid dynamics (CFD) modeling was carried out to demonstrate uniformity of the nose-only exposure chambers. Because it is very important in the inhalation toxicity experiments that test materials are distributed uniformly to each holder of the chamber. The test was done with these 3 types of chamber with different form to develop inhalation toxicity evaluation system, easy-to-operate system among exposure chamber used for evaluating inhalation toxicity of environmental chemical mixtures. Through CFD interpretation, nose-only exposure chamber was made with the selection of the optimal conditions. For its evaluation, one type of fragrance was selected and measured particle size distribution of each port. The gene becoming luminous to green fluorescence was combined with GPT-SPE, a type of tGFP vector, to be inhaled to the mouse. Based on this, luminous intensity was checked. As a result, total particle number concentration of each port had average value of $3.17{\times}10^6{\sharp}/cm^3$ and range of the highest and lowest concentration value was approximately ${\pm}4.8%$. Autopsy of lung tissues of mouse showed that it had clearly better delivery of gene compared to the control group.

Field Distribution of the Reverberation Chamber with Flat Diffusers Composed of Multiple Dielectric Materials (다중 유전체로 구성된 평탄형 Diffuser가 부착된 잔향실 내의 전자기장 분포에 관한 연구)

  • Kim, Young-Ryoul;Kim, Hye-Kwang;Rhee, Joong-Geun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.5 s.120
    • /
    • pp.471-477
    • /
    • 2007
  • This paper presents the characteristics of electromagnetic field uniformity in a reverberation chamber with flat diffusers composed of multiple dielectric materials that can be used as an alternative facility for the analysis, test and evaluation of electromagnetic interference and immunity. The field characteristics and the size of the test volume inside the reverberation chamber with the new diffuser of multiple dielectric materials are simulated and analyzed at $2.5{\sim}3$ GHz band. The FDTD method is used to analyze the field characteristics. The field uniformity, polarization characteristics and tolerance are improved by the new diffuser with smaller physical size. The reverberation chamber with flat diffusers composed of multiple dielectric materials shows better electromagnetic performance and larger test volume than normal chamber.

Long Duration Current Impulse Withstand Characteristics and Uniformity of ZnO Blocks for High Voltage Surge Arresters (초고압 피뢰기용 ZnO 소자의 장시간 방전내량과 균일성)

  • Cho, Han-Goo;Yoo, Dae-Hoon;Lee, You-Jong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.486-487
    • /
    • 2007
  • This paper describes the evaluation of long duration current impulse withstand characteristics of ZnO blocks for high voltage surge arresters. Four ZnO varistors were manufactured with the general ceramic production method and three abroad varistors were also prepared to be compared. All varistors exhibited high density, which was in the range of $5.42{\sim}5.49g/cm^3$. In the electrical properties, the reference voltage of all samples was in the range of 5.11~5.72kV and the residual voltage was in the range of 8.314~9.305kV. In the long duration current impulse withstand test, sample 2 and 3 failed at the 2nd and 4th shot of series impulse currents, respectively, but the rest survived 18 shots during the test. Before and after this test, the variation ratio of the residual voltage of samples survived were below 1.7%, which were in the acceptance range of 5%.

  • PDF

A Study on the Optimized Measurements of Field Uniformity for Electromagnetic Radiated Immunity Test System (전자파 방사 내성 시험을 위한 최적화된 균일장 측정 방법에 관한 연구)

  • Cho Jin-Young;Mun Jun-Chul;Jung Chang-Kyoo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.6 s.97
    • /
    • pp.622-631
    • /
    • 2005
  • In this paper, we reduce 'over and under deviation' and 'over and under testing' which have a cause of uncertainty in electromagnetic radiated immunity test. We analyze continued measurement method of field uniformity and propose new estimate method having the minimum uncertainty condition. We test comparison in 4 anechoic chambers and analyze FDI(Field Deviation Index) which is the minimum deviation excess 6 dB on fields. We obtain that the proposed test method improve 1.193 dB than domestic standard(KN 61000-4-3) and 0.017 dB than international standard (IEC61000-4-3) in every frequency. In the test result 'over and under testing point' have 926 point at every field area and have 118 point at center uniform area. These result know that proposed measurement method have 10 point less at every field area and 9 point less at center uniform area than continued measurement method. The proposed test method have few point more than continued measurement method. Therefore, we confirmed that the proposed test method have the minimum uncertainty in electromagnetic radiated immunity test.

Reliability Tests on SpatiaLight's LCOS Microdisplays

  • Shin, Dong-Soo;Sun, Raymond;Jin, Michael
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.951-954
    • /
    • 2004
  • We report the recent reliability test results of SpatiaLight's liquid crystal on Silicon (LCOS) microdisplays. Two different types of reliability tests have been performed: 1) thermal and 2) thermal with high intensity UV light. Various important device parameters were regularly monitored including the contrast ratio, color uniformity, and switching time. The test data shows that there are no degradations that fail the pass criteria. Lifetime estimations are given from the test data.

  • PDF

Clinical Applications of Gastrointestinal Manometry in Children

  • Hong, Jeana
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.17 no.1
    • /
    • pp.23-30
    • /
    • 2014
  • Manometry is a noninvasive diagnostic tool for identifying motility dysfunction of the gastrointestinal tract. Despite the great technical advances in monitoring motility, performance of the study in pediatric patients has several limitations that should be considered during the procedure and interpretation of the test results. This article reviews the clinical applications of conventional esophageal and anorectal manometries in children by describing a technique for performing the test. This review will develop the uniformity required for the methods of performance, the parameters for measurement, and interpretation of test results that could be applied in pediatric clinical practice.

Evaluation on the radio influence voltage of ${7^1/2}$ pin type domestic insulators (국산 핀애자의 라디오 방해 전압(RIV) 평가)

  • 양배덕
    • 전기의세계
    • /
    • v.25 no.6
    • /
    • pp.65-68
    • /
    • 1976
  • For the RIV characteristics test of power apparatus, an indoor measuring system of radio influence voltage was set up and by means of this measuring unit SIV characteristics on the 7$^{1}$2/" pin-type domestic insulators were examined. According to the test data, RIV values of all the test pieces exceeded the maximum permissible level at 10kV applied voltage. The electrical resistivity of domestic semi-conductive glaze as good as importedone but un-uniformity of coating is turned out to be a main cause of failure.lure.

  • PDF